In general, Cerenkov light is produced by a charged particle that passes through a medium with a velocity greater than that of visible light. Although the wavelength of Cerenkov light is very broad, the peak is in the almost visible range from 400 to 480 nm. Therefore, it always causes a problem to detect a real light signal that is generated in the scintillator on the fiber-optic sensor tip for dose measurements of high-energy electron beam. The objectives of this study are to measure, characterize and remove Cerenkov light generated in a fiber-optic radiation sensor tip to detect a real light signal from the scintillator. In this study, the intensity of Cerenkov light is measured and characterized as a function of incident angle of electron beam from a LINAC, and as a function of the energy of electron beam. As a measuring device, a photodiode-amplifier system is used, and a subtraction method using a background optical fiber is investigated to remove Cerenkov light.
양성자 빔의 조사선량에 따라 정상섬유모세포인 MRC-5와 신경모세포종세포인 SK-N-SH의 DNA 손상도를 확인하고 시간 흐름에 따른 회복률을 비교 분석하였다. 두 가지의 세포에 2Gy, 5Gy, 8Gy의 양성자 빔을 각각 조사한 후 Alkaline comet assay를 실시하였다. Tail moment를 측정하여 DNA의 손상도를 비교하였고 일정시간이 지난 후 재 측정을 하여 두 가지 세포의 회복가능성을 비교하였다. 세가지 선량으로 양성자 빔을 조사하였을 때 전체적으로 SK-N-SH에 비해 MRC-5의 DNA 손상도는 낮았지만 8Gy 조사하였을 때 MRC-5의 Tail moment값은 $50.3202{\pm}23.17155$로 위험수준의 손상이 발생함을 알 수 있었다. 또한 2Gy와 5Gy 조사하였을 때 두 세포 모두 25시간 안에 거의 회복되는 반면 8Gy 조사시 두 세포 모두 회복률이 낮아졌으며 MRC-5의 경우 25시간 후 측정시 Tail moment값은 $18.1536{\pm}4.42849$로 선량 증가에 크게 반응하여 회복률이 낮아짐을 확인하였다. 양성자 빔의 SOBP 중 다른 지점에 비해 distal declining edge에서 LET가 더 높으며 선량을 높이면 그 차이는 월등히 커진다. 이러한 특징과 더불어 본 연구에서 확인한 고선량 조사시 정상섬유모세포의 회복률이 낮아져 지속적인 손상으로 이어진다는 점은 양성자 치료시 주의하여야 한다. 종양조직에 해당하는 SOBP 중심부에 조사되는 조건 뿐 아니라 더 높은 RBE의 주변 정상조직에 적용되는 조사조건을 확인하여야 부작용을 막을 수 있다.
목 적 : 두경부암의 양성자 치료 시 BoS frame ($Q-fix^{TM}$)을 사용하면 후사방향의 빔 조사 시 couch 와 snout 사이 충돌을 피하면서 Airgap 을 최소화할 수 있다. 이는 couch 에서 BoS frame 을 얼마나 많이 extended 시켰는지가 각 치료 빔 방향의 Airgap (환자와 빔 사출구 거리)을 결정하기 때문이다. 이에 본원에서는 BoS frame의 제한점을 개선하기 위하여 고정장치를 자체 제작하였고, 제작한 고정장치의 유용성을 본 연구를 통해 선량학적으로 평가하고자 한다. 대상 및 방법 : 본원에서 양성자치료를 받은 Brain Cancer환자 3명의 빔 각도 중 후사방향의 빔 6개를 선택하였다. 현재 치료계획 되어 있는 환자를 기존 방식대로 BoS frame만 사용했을 때 각 환자마다 왼쪽후사방향, 오른쪽 후사방향의 빔에서 충돌을 피할 수 있는 snout 위치를 측정하고 이 위치에 따른 Airgap과 Lateral penumbra 영역을 계산하고 DVH값을 분석하였다. 같은 환자의 동일한 빔에서 자체 제작한 BoS frame 고정장치를 사용하여 제조회사에서 권고한 set-up 사항보다 BoS frame을 21 cm superior방향으로 set-up을 진행하였고, 그 후 충돌을 피할 수 있는 snout위치를 측정하고 이 위치에서 Airgap과 Lateral penumbra영역을 계산하고 DVH값을 분석하였다. 결 과 : 자체 제작 BoS frame 고정장치를 사용함에 따라 사용하지 않았을 때 보다 snout 위치 즉 Airgap을 각각 각도별로 5.4 cm ~ 15.4 cm 줄일 수 있었다. Lateral penumbra는 BoS frame 고정장치를 사용하면서 Airgap을 감소시킴에 따라 각도별로 선량분포곡선에서 왼쪽, 오른쪽 부분을 0.1 cm ~ 0.4 cm 감소시킬 수 있었다. 자체 제작한 BoS frame 고정장치 사용함으로써 감소한 Lateral penumbra에 의해 정상조직에 들어가는 선량을 비교해보면 Lt.eyeball, Lt.lens, Lt.hippocampus, Lt.cochlea, Rt.eyeball, Rt.lens, Rt.cochlea, Rt. hippocampus, stem에 들어가는 선량이 0 CGE ~ 4.4 CGE 감소한 것을 알 수 있었다. 결 론 : 두경부암의 양성자 치료 시 자체제작 BoS frame 고정장치를 사용함에 따라 사용하지 않았을 때보다 후사방향의 빔에서 snout 위치를 감소시킬 수 있었고, Airgap을 줄여 결과적으로 Lateral penumbra를 감소시켜 정상조직에 불필요한 선량을 최소화 할 수 있었다. 이에 본 연구를 통해 자체제작 BoS frame 고정장치의 유용성을 선량학적으로 평가한 결과, 후사방향의 빔을 사용하는 두경부암 환자의 양성자 치료 시 유용하게 사용 될 것으로 기대된다. 마지막으로 두경부암 뿐만 아니라 다른 부위 양성자 치료에서도 Airgap을 최소한 할 수 있는 방법을 고안하여 Lateral penumbra를 줄일 수 있는 지속적인 연구가 필요할 것이라고 사료된다.
한국 원자력 연구소 부설 원자력병원에 설치된 AVF 싸이클로트론을 이용하여 요즈음 핵의학에 널리 사용되는 PET 용 싸이클로트론의 에너지를 검정 할 수 있고 양성자 과잉 핵종인 싸이클로트론 동위원소의 생산 수율에 중요한 변수인 양성자에너지를 탄소에 입사시켜 입사빔의 Range와 에너지를 측정하는 방법을 제시하였다. 본 실험에서 사용된 양성자 빔의 양성자 에너지는 35 MeV와 50 MeV 사이였으며, 탄소 막은 두께 6.3mm, 밀도 $1.712 g/cm^3$를 사용하였다. 탄소 표적물을 $0.9^{\circ}$씩 스텝 모터를 사용하여 회전시킴으로 두께를 변화 시켜 공칭 에너지에 대한 Range를 측정함으로써 입사된 양성자의 에너지를 구하였고 이를 인출반경과 RF주파수를 바탕으로 상대론 적으로 계산된 에너지와 비교하였다.
Yinan Zhu;Zuokang Lin;Haiyan Yu;Xiaohan Yu;Zhimin Dai
Nuclear Engineering and Technology
/
제56권5호
/
pp.1813-1821
/
2024
Beam shaping assembly (BSA) is a vital component in Boron Neutron Capture Therapy (BNCT) for obtaining epithermal neutron beams. Several feasible designs of BSA for accelerator-based BNCT (AB-BNCT) neutron source are carried out based on neutrons by bombarding a natural lithium target with 10 mA, 2.8 MeV proton beams. The calculation results demonstrate that a thickness of 45 cm is appropriate for general moderators referring to the therapeutic parameter of Advanced Depth (AD). A series of optimizations are performed and two results are confirmed: One is that employing the configuration of MgF2 and FLUENTAL combined by 1:1 could improve the therapeutic rate (TR) of tumors at a depth of middle region, and the other one is that the TR of superficial tumors can be increased by adding a 5 cm thick boron-11 secondary moderator at the end of general moderators. As a result, an innovative conception of an adjustable moderator is recommended to BNCT. Compared to the MgF2 moderator with a fixed thickness of 45 cm, the TR value can be improved by a maximum of 47.7 % by using the adjustable moderator. Furthermore, the configuration of adjustable moderator has been designed with regulation method for treating tumors of different depths.
We studied the H/D exchange kinetics of pure and acid dopped water-ice film by using the techniques of reactive ions scattering (RIS) and low energy sputtering (LES) with low kinetic energy cesium ion beam (<35 eV). From RIS, neutral water isotopomers were detected in the form of cesium-molecule ion clusters, $CsX^+$ (X= $H_2O$, HDO, $D_2O$). Ionic species, like $H_3O^+$, $DH_2O^+$, $D_2HO^+$, $D_3O^+$, adsorbed on the surface were ejected via LES process. Those techniques allowed us to trace the isotopomeric populations of water-ice film. To show the catalytic effect of excess proton in the H/D exchange reaction, our study was conducted with two types of water-ice films. In film 1, about 0.5 BL of $H_2O$ was adsorbed on HCl (0.1 ML) dopped $D_2O$ (8 BL) film. In film 2, similar amount of $H_2O$ used in film 1 was adsorbed on pure $D_2O$ film. Kinetic data were obtained from each film type for 90-110 K (film 1) and 110-130 K (film 2) and fitted with numerically integrated lines. Through the Arrhenius plot of kinetic coefficient deduced from fitting of the H/D exchange reaction, the activation energy of film 1 and 2 were estimated to be $10{\pm}3kJmol^{-1}$ and $17{\pm}4kJmol^{-1}$. This activation barrier difference could be understood from detailed pictures of H/D exchange. In film 2, both the formation of ion pair, $H_3O^+$ and OH. and proton transfer were needed for the H/D exchange. However, in film 1, only proton transfer was necessary but ion pair formation was not, so this might reduce the activation energy.
Sagisaka, Akito;Daido, Hiroyuki;Pirozhkov, Alexander S.;Yogo, Akifumi;Ogura, Koichi;Orimo, Satoshi;Ma, Jinglong;Mori, Michiaki;Nishiuchi, Mamiko;Bulanov, Sergei V.;Esirkepov, Timur Zh.;Oishi, Yuji;Nayuki, Takuya;Fujii, Takashi;Nemoto, Koshichi;Nagatomo, Hideo
Journal of the Optical Society of Korea
/
제13권1호
/
pp.37-41
/
2009
We observe the proton signals produced by laser interaction with thin-foil targets of polyimide and of copper. We change the thickness of the polyimide target to $7.5{\mu}m$, $12.5{\mu}m$, and $50{\mu}m$. High-energy protons with the maximum energy of ${\sim}2.3\;MeV$ from $7.5{\mu}m$ thick polyimide are observed. This proton beam with the maximum energy of multi-MeV has various applications such as a proton shadowgraphy.
방사선 치료 시 방사선이 조사되는 동안 환자의 움직임을 모니터링하는 것은 치료의 성공을 결정 하는 중요한 요인이다. 따라서 방사선이 조사되는 동안 환자의 움직임을 실시간으로 감시하고 움직인 치료위치를 자동으로 보정 할 수 있는 시스템을 개발 하였다. 원점을 중심으로 직교하게 위치한 2개의 CCD 카메라를 이용하여 3차원적 환자의 위치를 확인 하고, 틀 맞춘 상호교차 비교법(normalized cross-correlation method)을 이용한 영상 본 맞춤(image pattern matching) 방법을 이용한 환자위치 모니터링 시스템을 개발하였다. CCD카메라로부터 촬영된 영상을 컴퓨터로 전달하여 위치 변화를 정량적으로 분석 하여 빔 켜고 끔(beam on and off)를 위한 방아쇠신호(trigger signal)를 발생시키고, 이동치료대(moving couch)의 모터를 제어할 수 있는 시스템을 개발하였다. 이 시스템은 0.5 mm 이하의 분해능으로 환자의 위치를 자동으로 보정할 수 있었다.
The aluminum nitride(AlN) layer on Al7075 substrate has been formed through nitrogen ion implantation process. The implantation process was performed under the conditions : 100 keV energy, total ion dose up to $2{\times}10^{18}\;ions/cm^2$. XRD analysis showed that aluminum nitride layers were formed by nitrogen implantation. The formation of Aluminum nitride enhanced surface hardness up to 265HK(0.02 N) from 150HK(0.02 N) for the unimplanted specimen. Micro-Knoop hardness test showed that wear resistance was improved about 2 times for nitrogen implanted specimens above $5\;{\times}\;10^{17}\;ions/cm^2$. The friction coefficient was measured by Ball-on-disc type wear tester and was decreased to 1/3 with increasing total nitrogen ion dose up to $1\;{\times}\;10^{18}ions/cm^2$. The enhancement of mechanical properties was observed to be closely associated with AlN formation. AES analysis showed that the maximum concentration of nitrogen increased as ion dose increased until $5\;{\times}\;10^{17}\;ions/cm^2$.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.