• Title/Summary/Keyword: proton beam

Search Result 266, Processing Time 0.038 seconds

Measurements and characterizations of cerenkov light in fiber-optic radiation sensor irradiated by high energy electron beam (고에너지 전자선 측정을 위한 광섬유 방사선 센서에서의 체렌코프 빛 측정 및 분석)

  • Jang, Kyoung-Won;Cho, Dong-Hyun;Jeong, Sun-Cheol;Jun, Jae-Hun;Lee, Bong-Soo;Kim, Sin;Cho, Hyo-Sung;Park, Sung-Yong;Shin, Dong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.186-191
    • /
    • 2006
  • In general, Cerenkov light is produced by a charged particle that passes through a medium with a velocity greater than that of visible light. Although the wavelength of Cerenkov light is very broad, the peak is in the almost visible range from 400 to 480 nm. Therefore, it always causes a problem to detect a real light signal that is generated in the scintillator on the fiber-optic sensor tip for dose measurements of high-energy electron beam. The objectives of this study are to measure, characterize and remove Cerenkov light generated in a fiber-optic radiation sensor tip to detect a real light signal from the scintillator. In this study, the intensity of Cerenkov light is measured and characterized as a function of incident angle of electron beam from a LINAC, and as a function of the energy of electron beam. As a measuring device, a photodiode-amplifier system is used, and a subtraction method using a background optical fiber is investigated to remove Cerenkov light.

DNA Repair Characteristics of MRC-5 and SK-N-SH Irradiated with Proton Beam (양성자빔 조사에 따른 MRC-5와 SK-N-SH의 DNA 손상 후 회복 특성)

  • Choi, Eun-Ae;Lee, Bong-Soo;Cho, Young-Ho
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.333-339
    • /
    • 2011
  • The purpose of this study is to compare DNA repair characteristics of normal fibroblast cell (MRC-5) and neuroblastoma cell (SK-N-SH) induced by proton beam. Cells were irradiated with 2Gy, 5Gy and 8Gy proton beam. The rate of DNA rejoining was measured by alkaline version of the comet assay. After a repair time, tail moment was measured again. The tail moment of MRC-5 was lower than SK-N-SH. However, after 8Gy of exposure, the tail moment of MRC-5 was measured as 50.320223.17155 which represents dangerous level of DNA damage. The cells were repaired practically within 25 hours after 2 and 5Gy of exposure while they were not fully recovered after 8Gy of exposure. Especially, tail moment of MRC-5 after 25 hours was 18.15364.42849. In the distal declining edge of SOBP, the RBE value is increased by high LET. The RBE differences of SOBP in high-dose were greater than low-dose. After the high-dose exposure, MRC-5 of normal fibroblast cell could lead to lasting DNA damage as shown in this study. In conclusion, we has to pay special attention when the region of the treatment volume is close to sensitive tissues.

Dosimetric evaluation of using in-house BoS Frame Fixation Tool for the Head and Neck Cancer Patient (두경부암 환자의 양성자 치료 시 사용하는 자체 제작한 BoS Frame 고정장치의 선량학적 유용성 평가)

  • Kim, kwang suk;Jo, kwang hyun;Choi, byeon ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.35-46
    • /
    • 2016
  • Purpose : BoS(Base of Skull) Frame, the fixation tool which is used for the proton of brain cancer increases the lateral penumbra by increasing the airgap (the distance between patient and beam jet), due to the collision of the beam of the posterior oblique direction. Thus, we manufactured the fixation tool per se for improving the limits of BoS frame, and we'd like to evaluate the utility of the manufactured fixation tool throughout this study. Materials and Methods : We've selected the 3 patients of brain cancer who have received the proton therapy from our hospital, and also selected the 6 beam angles; for this, we've selected the beam angle of the posterior oblique direction. We' ve measured the planned BoS frame and the distance of Snout for each beam which are planned for the treatment of the patient using the BoS frame. After this, we've proceeded with the set-up that is above the location which was recommended by the manufacturer of the BoS frame, at the same beam angle of the same patient, by using our in-house Bos frame fixation tool. The set-up was above 21 cm toward the superior direction, compared to the situation when the BoS frame was only used with the basic couch. After that, we've stacked the snout to the BoS frame as much as possible, and measured the distance of snout. We've also measured the airgap, based on the gap of that snout distance; and we've proceeded the normalization based on each dose (100% of each dose), after that, we've conducted the comparative analysis of lateral penumbra. Moreover, we've established the treatment plan according to the changed airgap which has been transformed to the Raystation 5.0 proton therapy planning system, and we've conducted the comparative analysis of DVH(Dose Volume Histogram). Results : When comparing the result before using the in-house Bos frame fixation tool which was manufactured for each beam angle with the result after using the fixation tool, we could figure out that airgap than when not used in accordance with the use of the in-house Bos frame fixation tool was reduced by 5.4 cm ~ 15.4 cm, respectively angle. The reduced snout distance means the airgap. Lateral Penumbra could reduce left, right, 0.1 cm ~ 0.4 cm by an angle in accordance with decreasing the airgap while using each beam angle in-house Bos frame fixation tool. Due to the reduced lateral penumbra, Lt.eyeball, Lt.lens, Lt. hippocampus, Lt. cochlea, Rt. eyeball, Rt. lens, Rt. cochlea, Rt. hippocampus, stem that can be seen that the dose is decreased by 0 CGE ~ 4.4 CGE. Conclusion : It was possible to reduced the airgap by using our in-house Bos frame fixation tool for the proton therapy; as a result, it was possible to figure out that the lateral penumbra reduced. Moreover, it was also possible to check through the comparative analysis of the treatment plan that when we reduce the lateral penumbra, the reduction of the unnecessary irradiation for the normal tissues. Therefore, Using the posterior oblique the Brain cancer proton therapy should be preceded by decreasing the airgap, by using our in-house Bos frame fixation tool; also, the continuous efforts for reducing the airgap as much as possible for the proton therapy of other area will be necessary as well.

  • PDF

A Measurement of Proton Beam Energy using Carbon Target for Medical Cyclotron (탄소 표적물을 사용한 의료용 싸이클로트론의 양성자 에너지 측정)

  • Chai, Jong-Seo;Ha, Jang-Ho;Kim, Yu-Seok;Lee, Dong-Hun;Lee, Min-Yong;Hong, Seong-Seok
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.3
    • /
    • pp.350-354
    • /
    • 1995
  • 한국 원자력 연구소 부설 원자력병원에 설치된 AVF 싸이클로트론을 이용하여 요즈음 핵의학에 널리 사용되는 PET 용 싸이클로트론의 에너지를 검정 할 수 있고 양성자 과잉 핵종인 싸이클로트론 동위원소의 생산 수율에 중요한 변수인 양성자에너지를 탄소에 입사시켜 입사빔의 Range와 에너지를 측정하는 방법을 제시하였다. 본 실험에서 사용된 양성자 빔의 양성자 에너지는 35 MeV와 50 MeV 사이였으며, 탄소 막은 두께 6.3mm, 밀도 $1.712 g/cm^3$를 사용하였다. 탄소 표적물을 $0.9^{\circ}$씩 스텝 모터를 사용하여 회전시킴으로 두께를 변화 시켜 공칭 에너지에 대한 Range를 측정함으로써 입사된 양성자의 에너지를 구하였고 이를 인출반경과 RF주파수를 바탕으로 상대론 적으로 계산된 에너지와 비교하였다.

  • PDF

Excess proton catalyzed H/D exchange reaction at the ice surface

  • Moon, Eui-Seong;Kang, Heon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.333-333
    • /
    • 2011
  • We studied the H/D exchange kinetics of pure and acid dopped water-ice film by using the techniques of reactive ions scattering (RIS) and low energy sputtering (LES) with low kinetic energy cesium ion beam (<35 eV). From RIS, neutral water isotopomers were detected in the form of cesium-molecule ion clusters, $CsX^+$ (X= $H_2O$, HDO, $D_2O$). Ionic species, like $H_3O^+$, $DH_2O^+$, $D_2HO^+$, $D_3O^+$, adsorbed on the surface were ejected via LES process. Those techniques allowed us to trace the isotopomeric populations of water-ice film. To show the catalytic effect of excess proton in the H/D exchange reaction, our study was conducted with two types of water-ice films. In film 1, about 0.5 BL of $H_2O$ was adsorbed on HCl (0.1 ML) dopped $D_2O$ (8 BL) film. In film 2, similar amount of $H_2O$ used in film 1 was adsorbed on pure $D_2O$ film. Kinetic data were obtained from each film type for 90-110 K (film 1) and 110-130 K (film 2) and fitted with numerically integrated lines. Through the Arrhenius plot of kinetic coefficient deduced from fitting of the H/D exchange reaction, the activation energy of film 1 and 2 were estimated to be $10{\pm}3kJmol^{-1}$ and $17{\pm}4kJmol^{-1}$. This activation barrier difference could be understood from detailed pictures of H/D exchange. In film 2, both the formation of ion pair, $H_3O^+$ and OH. and proton transfer were needed for the H/D exchange. However, in film 1, only proton transfer was necessary but ion pair formation was not, so this might reduce the activation energy.

  • PDF

Development of Laser-driven Proton Source Toward Its Applications

  • Sagisaka, Akito;Daido, Hiroyuki;Pirozhkov, Alexander S.;Yogo, Akifumi;Ogura, Koichi;Orimo, Satoshi;Ma, Jinglong;Mori, Michiaki;Nishiuchi, Mamiko;Bulanov, Sergei V.;Esirkepov, Timur Zh.;Oishi, Yuji;Nayuki, Takuya;Fujii, Takashi;Nemoto, Koshichi;Nagatomo, Hideo
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.37-41
    • /
    • 2009
  • We observe the proton signals produced by laser interaction with thin-foil targets of polyimide and of copper. We change the thickness of the polyimide target to $7.5{\mu}m$, $12.5{\mu}m$, and $50{\mu}m$. High-energy protons with the maximum energy of ${\sim}2.3\;MeV$ from $7.5{\mu}m$ thick polyimide are observed. This proton beam with the maximum energy of multi-MeV has various applications such as a proton shadowgraphy.

The Development of Real Time Automatic Patient Position Correction System during the Radiation Therapy Based on CCD: A Feasibility Study (CCD기반의 방사선치료 중 실시간 자동 환자 위치보정 시스템 개발: 타당성 연구)

  • Shin, Dongho;Chung, Kwangzoo;Kim, Meyoung;Son, Jaeman;Yoon, Myonggeun;Lim, Young Kyung;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.191-197
    • /
    • 2013
  • Upon radiation treatment, it is the important factor to monitor the patient's motion during radiation irradiated, since it can determine whether the treatment is successful. Thus, we have developed the system in which the patient's motion is monitored in real time and moving treatment position can be automatically corrected during radiation irradiation. We have developed the patient's position monitoring system in which the patient's position is three dimensionally identified by using two CCD cameras which are orthogonal located around the isocenter. This system uses the image pattern matching technique using a normalized cross-correlation method. We have developed the system in which trigger signal for beam on and off is generated by quantitatively analyzing the changes in a treatment position through delivery of the images taken from CCD cameras to the computer and the motor of moving couch can be controlled. This system was able to automatically correct a patient's position with the resolution of 0.5 mm or less.

The Formation of Nitride and Enhancement of Mechanical Properties of Al Alloy by Nitrogen Implantation (Al합금에서 질소이온주입에 의한 질화물 형성과 기계적 특성 향상)

  • Jeong, Jae-Pil;Lee, Jae-Sang;Kim, Kye-Ryung;Choi, Byung-Ho
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.5
    • /
    • pp.235-239
    • /
    • 2006
  • The aluminum nitride(AlN) layer on Al7075 substrate has been formed through nitrogen ion implantation process. The implantation process was performed under the conditions : 100 keV energy, total ion dose up to $2{\times}10^{18}\;ions/cm^2$. XRD analysis showed that aluminum nitride layers were formed by nitrogen implantation. The formation of Aluminum nitride enhanced surface hardness up to 265HK(0.02 N) from 150HK(0.02 N) for the unimplanted specimen. Micro-Knoop hardness test showed that wear resistance was improved about 2 times for nitrogen implanted specimens above $5\;{\times}\;10^{17}\;ions/cm^2$. The friction coefficient was measured by Ball-on-disc type wear tester and was decreased to 1/3 with increasing total nitrogen ion dose up to $1\;{\times}\;10^{18}ions/cm^2$. The enhancement of mechanical properties was observed to be closely associated with AlN formation. AES analysis showed that the maximum concentration of nitrogen increased as ion dose increased until $5\;{\times}\;10^{17}\;ions/cm^2$.

Strategies to improve the range verification of stochastic origin ensembles for low-count prompt gamma imaging

  • Hsuan-Ming Huang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3700-3708
    • /
    • 2023
  • The stochastic origin ensembles method with resolution recovery (SOE-RR) has been proposed to reconstruct proton-induced prompt gammas (PGs), and the reconstructed PG image was used for range verification. However, due to low detection efficiency, the number of valid events is low. Such a low-count condition can degrade the accuracy of the SOE-RR method for proton range verification. In this study, we proposed two strategies to improve the reconstruction of the SOE-RR algorithm for low-count PG imaging. We also studied the number of iterations and repetitions required to achieve reliable range verification. We simulated a proton beam (108 protons) irradiated on a water phantom and used a two-layer Compton camera to detect 4.44-MeV PGs. Our simulated results show that combining the SOE-RR algorithm with restricted volume (SOE-RR-RV) can reduce the error of the estimation of the Bragg peak position from 5.0 mm to 2.5 mm. We also found that the SOE-RR-RV algorithm initialized using a back-projection image could improve the convergence rate while maintaining accurate range verification. Finally, we observed that the improved SOE-RR algorithm set for 60,000 iterations and 25 repetitions could provide reliable PG images. Based on the proposed reconstruction strategies, the SOE-RR algorithm has the potential to achieve a positioning error of 2.5 mm for low-count PG imaging.

Surface treatment of bipolar plates for PEMFC (Proton Exchange Membrane Fuel Cell) application (PEMFC (Proton Exchange Membrane Fuel Cell)용 바이폴라 플레이트 표면개질)

  • Jeon, Gwang-Yeon;Yun, Young-Hoon;Cha, In-Su
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.643-645
    • /
    • 2008
  • Stainless steel 304 and 316 plates were deposited with the multi-layered coatings of titanium film (0.1um) and gold film (1-2um) by an electron beam evaporation method. The XRD patterns of the stainless steel plates modified with the multi-layered coatings showed the crystalline phases of the external gold film and the stainless steel substrate. Surface microstructural morphologies of the stainless steel bipolar plates modified with multi-layered coatings were observed by AFM and FE-SEM images. The external gold films formed on the stainless steel plates showed microstructure of grains of about 100nm diameter. The grain size of the external surface of the stainless steel plates increased with the gold film thickness. The electrical resistance and water contact angle of the stainless steel bipolar plates covered with multi-layered coatings were examined with the thickness of the external gold film.

  • PDF