• Title/Summary/Keyword: proton beam

Search Result 266, Processing Time 0.029 seconds

Comparison of Beam Delivery Modes in Prostate Cancer Proton Therapy: A Treatment Planning Comparison Study (전립선암 환자 양성자치료 시 빔 전달방식에 따른 치료계획 비교)

  • Kim, Youn Young;Youm, Doo Seok;Jang, Yo Jong;Kang, Dong Yun;Park, Jeong Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.153-158
    • /
    • 2013
  • Purpose: After making two plans, the Double Scattering (DS) Mode and The Pencil Beam Scanning (PBS) Mode, of patients on early prostate cancer, we not only compare the dose conformity and the dose homogeneity by analyzing each DVH, CN and HI, but also evaluate normal structures's sparing effect on each mode. Materials and Methods: Planes about nine patients, who did proton therapy, on prostate cancer was setted using the Eclipse proton external beam planning system. The prescription dose, every $2.5 Gy{\times}28$ fractions=70 Gy, was delivered to the PTV. The CN and the HI were getted by anlazing each DVHs for the DS Plan and the PBS Plan. Also, normal structures' %volumes according to dose of the PBS are campared with those of the DS. Results: The average CN of the PTV is increase 16.63% from DS $0.68{\pm}0.07$ to PBS $0.79{\pm}0.01$, and the average IN of the PTV is decrease -22.66 % from DS $0.12{\pm}0.03$ to PBS $0.09{\pm}0.01$. The PBS has litter %Volumes of normal structures than the DS about every patient except Rectum. The average %Volume of Left Femoral Head receiving ${\geq}30$ Gy shows most high decreasing rate, -79.93%, from DS to PBS and the average %Volume of Rectum receiving ${\geq}70$ Gy shows most low decreasing rate, -3.03%, from DS to PBS. Conclusion: Therefore, the PBS is more effective achieving the dose conformity and the dose Homogeneity than DS, and better to reduce unnecessary dose arriving normal structures, especially the femoral heads.

  • PDF

A Research on Superparamagnetic Iron Oxide Nanoparticles' Toxicity to U373MG Cell and its Effect on the Radiation Survival Curve (산화철 나노입자의 U373MG 세포 독성평가 및 방사선 세포생존 곡선에 미치는 영향에 대한 연구)

  • Kang, Seonghee;Kim, Jeonghwan;Kim, Dokyung;Kang, Bosun
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.507-513
    • /
    • 2012
  • This research was performed to evaluate the superparamagnetic iron oxide nanoparticles'(SPIONs) cell toxicity and to measure the radiation cell survival curve changes of SPIONs-uptake glioblastoma multiforme cells. The results could be practically used as the fundamental data to ameliorate proton beam cancer therapy, for example, providing necessary GBM treatment dose in the proton beam therapy when the therapy takes advantage of SPIONs. The assessment of the toxicological evaluation of synthesized SPIONs was accomplished by MTT assay as an in vitro experiment. The results showed no meaningful differences in the cell survival rate at the $1-100{\mu}g/ml$ SPIONs concentrations, but the cell toxicity was shown as the cell survival rate decreased up to 74.2% at the $200{\mu}g/ml$ SPIONs concentration. Then, we measured each radiation cell survival curve for U373MG cells and SPIONs-uptake U373MG cells with 0~5 Gy of proton beam irradiations. It is learned from the analysis of the experimental results that the SPION-uptake cells' radiation survival rate was more rapidly decreased as the irradiation dose increased. In conclusion we confirmed that SPIONs-uptake in U373MG cells induces cell death at the much less dose than the lethal dose of SPION-non-uptake cell. This research shows that the therapeutic efficacy of glioblastoma multiforme treatment in proton beam therapy can be improved by SPIONs targeting to the GBM cells.

A Study of Radiation Exposure in Proton Therapy Facility (양성자치료기 가속기 시설에서의 작업종사자의 방사선 피폭 연구)

  • Lee, Sang-Hoon;Shin, Dong-Ho;Yoon, Myong-Geun;Shin, Jung-Wook;Rah, Jeong-Eun;Kwak, Jung-Won;Park, Sung-Yong;Shin, Kyung-Hwan;Lee, Doo-Hyun;Ahn, Sung-Hwan;Kim, Dae-Yong;Cho, Kwan-Ho;Lee, Se-Byeong
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.37-42
    • /
    • 2009
  • Proton therapy facility, which is recently installed at National Cancer Center in Korea, generally produces a large amount of radiation near cyclotron due to the secondary particles and radioisotopes caused by collision between proton and nearby materials during the acceleration. Although the level of radiation by radioisotope decreases in length of time, radiation exposure problem still exists since workers are easily exposed by a low level of radiation for a long time due to their job assignment for maintenance or repair of the proton facility. In this paper, the working environment near cyclotron, where the highest radiation exposure is expected, was studied by measuring the degree of radiation and its duration for an appropriate level of protective action guide. To do this, we measured the radiation change in the graphite based energy degrader, the efficiency of transmitted beam and relative activation degree of the transmission beam line. The results showed that while the level of radiation exposure around cyclotron and beam line during the operation is much higher than the other radiation therapy facilities, the radiation exposure rate per year is under the limit recommended by the law showing 1~3 mSv/year.

  • PDF

Dosimetric Influence of Implanted Gold Markers in Proton Therapy for Prostate Cancer (전립선암에 대한 양성자치료에서 금마커에 의한 방사선 선량분포의 영향)

  • Kwak, Jung-Won;Shin, Jung-Wook;Kim, Jin-Sung;Park, Sung-Yong;Shin, Dong-Ho;Yoon, Myong-Geun;Park, So-Ah;Kim, Dong-Wook;Lim, Young-Gyeung;Lee, Se-Byeong
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.291-297
    • /
    • 2010
  • This study examined the dosimetric influence of implanted gold markers in proton therapy and the effects of their positions in the spread-out Bragg peak (SOBP) proton beam. The implanted cylindrical gold markers were 3 mm long and 1.2 mm in diameter. The dosimetric influence of the gold markers was determined with markers at various locations in a proton-beam field. Spatial dose distributions were measured using a three-dimensional moving water phantom and a stereotactic diode detector with an effective diameter of 0.5 mm. Also, a film dosimetry was performed using Gafchromic External Beam Treatment (EBT) film. The GEANT4 simulation toolkit was used for Monte-Carlo simulations to confirm the measurements and to construct the dose-volume histogram with implanting markers. Motion data were obtained from the portal images of 10 patients to investigate the effect of organ motions on the dosimetric influence of markers in the presence of a rectal balloon. The underdosed volume due to a single gold marker, in which the dose was less than 95% of a prescribed amount, was 0.15 cc. The underdosed volume due to the presence of a gold marker is much smaller than the target volume. However, the underdosed volume is inside the gross tumor volume and is not smeared out due to translational prostate motions. The positions of gold markers and the conditions of the proton-beam field give different impacts on the dose distribution of a target with implanted gold markers, and should be considered in all clinical proton-based therapies.

Comparison of Beam Transfer Methods between Tomo Therapy and Proton Therapy for Prostate Cancer Radiation Therapy (전립선암 방사선 치료 시 토모치료와 양성자치료 빔 전달방식 비교)

  • Park, Jung Min;Ko, Eun Seo;Lee, Jin Hee;Kim, Jin Won;Yang, Jin Ho;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.75-81
    • /
    • 2019
  • Purpose: Tomo therapy and Proton therapy treatment plans for the treatment of prostate cancer patients were established, and the characteristics of dose distribution according to beam delivery method using Tomo therapy IMRT method and Proton therapy PBS method to compare and analyze the treatment effect were sought. Materials and Methods: Tomo IMRT treatment plan and Proton PBS treatment plan were established using the Hi.art planning station 5.1.1.6 of Tomo therapy and Eclipse 13.7 of VARIAN for three prostate cancer patients who were treated with radiotherapy only for radical purposes without surgery. For the evaluation of two treatment plans, the average dose (Dmean) and maximum dose (Dmax) of PGTV were calculated from dose volume histogram (DVH) to confirm the coverage and calculate CI and HI. In OAR evaluation, the dose received from the rectal volume 25% and the dose received from the bladder were evaluated to compare the normal long-term protection effect. Results: The mean maximum doses of the three patients were 71.4Gy, 75.3Gy and the mean doses were 70.4Gy and 72.8Gy in the DVH of the Tomo IMRT and Proton PBS. The CI was 1.16 and 1.31, and the HI was 0.04 and 0.12 respectively, and the Tomo IMRT was superior to the Proton PBS in dose suitability. Conclusion: The mean dose of PGTV in prostate cancer patients was 3.4% higher in Proton PBS than in Tomo IMRT. This is because the Dose suitability of Tomo IMRT was better, but it is considered to be a small difference to be seen as a significant result. However, the results of the two methods were 51.2% in D 25% and 55.7% less in the average dose of bladder, which could reduce the side effects of patients in proton PBS.

Preliminary Test of 3D Printed Plastic Scintillators for Proton Beam (3D 프린팅 플라스틱 섬광체의 양성자 빔에 대한 적용)

  • Sung-Hwan, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.681-686
    • /
    • 2022
  • In this study, a scintillation resin for 3D printing was fabricated with 1.0 wt% of PPO organic scintillator, 5.0 wt% of MMA, and commercial acrylic resin. Using the scintillation resin, 3D-shaped plastic scintillator radiation sensors were successfully fabricated quickly and inexpensively with a commercial 3D DLP printer. The 3D printed plastic scintillator has a good dose-output linearity of R-square 0.998 was obtained in the range of 1 to 10 nA of beam current of the 45 MeV proton beam. The developed 3D plastic scintillator has low light output, so there is a limit to its use in low-dose-rate gamma-ray or X-ray dosimetry. However, it was confirmed that the tissue equivalent material could be usefully used for measuring high energy or high dose rates radiation, such as proton beams and ultra-high dose rate beams.

Study on Optimization of Detection System of Prompt Gamma Distribution for Proton Dose Verification (양성자 선량 분포 검증을 위한 즉발감마선 분포측정 장치 최적화 연구)

  • Lee, Han Rim;Min, Chul Hee;Park, Jong Hoon;Kim, Seong Hoon;Kim, Chan Hyeong
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.162-168
    • /
    • 2012
  • In proton therapy, in vivo dose verification is one of the most important parts to fully utilize characteristics of proton dose distribution concentrating high dose with steep gradient and guarantee the patient safety. Currently, in order to image the proton dose distribution, a prompt gamma distribution detection system, which consists of an array of multiple CsI(Tl) scintillation detectors in the vertical direction, a collimator, and a multi-channel DAQ system is under development. In the present study, the optimal design of prompt gamma distribution detection system was studied by Monte Carlo simulations using the MCNPX code. For effective measurement of high-energy prompt gammas with enough imaging resolution, the dimensions of the CsI(Tl) scintillator was determined to be $6{\times}6{\times}50mm^3$. In order to maximize the detection efficiency for prompt gammas while minimizing the contribution of background gammas generated by neutron captures, the hole size and the length of the collimator were optimized as $6{\times}6mm^2$ and 150 mm, respectively. Finally, the performance of the detection system optimized in the present study was predicted by Monte Carlo simulations for a 150 MeV proton beam. Our result shows that the detection system in the optimal dimensions can effectively measure the 2D prompt gamma distribution and determine the beam range within 1 mm errors for 150 MeV proton beam.

Comparison of Doses of Single Scan PBS and Layered Rescanning PBS Using Moving Phantom in Proton Therapy (양성자 치료에서 Moving Phantom을 이용한 Single Scan PBS와 Layered Rescanning PBS의 선량비교)

  • Kim, Kyeong Tae;Kim, Seon Yeong;Kim, Dae Woong;Kim, Jae Won;Park, Ji Yeon;Jeon, Sang Min
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.43-49
    • /
    • 2019
  • Purpose : We apply the Layered Rescanning PBS designed to complement the Pencil Beam Scanning(PBS), which is vulnerable to moving organs with the Moving Phantom, and compare the homogeneity with the single scan PBS. Methods and materials: Matrix X (IBA, Belgium) and Moving Phantom (standard imaging, USA) were used. A dose of 200 cGy was measured in the AP direction on a hypothetical tumor $10{\times}10{\times}5cm$. The plan type was planned as 4 kinds of sinlge scan PBS, rescan number 4, 8, 12 times. Were measured three times for each types. During the measurement, the respiratory cycle of the Moving Phantom was generally set to 4 seconds per cycle, and the movement radius in the S-I direction was set to 2 cm. In addition, beam on time was measured. Results : The mean values of $D_{max}$ in the PTV were $246.47{\pm}18.8cGy$, $223.43{\pm}8.92cGy$, and $222.47{\pm}7.7cGy$, $213.9{\pm}6.11cGy$ and the mean values of $D_{min}$ were $165.53{\pm}4.32cGy$, $173.13{\pm}11.94cGy$, $184.13{\pm}8.04cGy$, $182.67{\pm}4.38cGy$ and the mean values of $D_{mean}$ $192.77{\pm}6.98cGy$, $196.7{\pm}4.01cGy$, $198.17{\pm}4.96cGy$, $195.77{\pm}3.15cGy$ respectively. As the number of rescanning increased, the Homogeneity Index converged to 1. The beam on time was measured as 2:15, 3:15, 4:30, 5:37 on average. In the measurement process, in the low dose layer of the MU, the problem was found that it was not rescanned as many times as the set number of rescan. Conclusions : In the treatment of tumors with long-term movements, the application of layered rescanning PBS showed a more uniform dose distribution than single scan PBS. And as the number of rescan increase, the distribution of homogeneity is uniform. Compared with single scan plan and 12 rescan plan, HI value was improved by 0.32. Further studies are expected to be applicable to patients who can not be treated with respiratory synchronous radiation therapy.

Proton Beam Sensitivity of Radical Scavenging Activity from Plant Resources (식물자원의 양성자 빔 조사에 대한 라디칼 소거능활성의 민감도)

  • Moon, Byung-Sik;Lee, Kap-Duk
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.35 no.3
    • /
    • pp.229-233
    • /
    • 2009
  • 20 species of plants were extracted with Methanol and were investigated for DPPH radical scavenging activity and ABTs free radical scavenging activity to quest anti-oxidation ability depending on the proton beam irradiation quantity. In the proton beam irradiation, 15 species's activities increased but among them, Pharbities nil Choisy decreased at 10 KGray and 4 species' activity didn't change at all. In hydrogen ion radical elimination activity, Ulmus macrocarpa (84 %) showed the highest and Pharbitis nil Choisy showed 6 % decreasing at more than 1 KGray. By comparison with untreated $IC_{50}$ value, the beam-treated $IC_{50}$ value increased 6.3 times for Dioscorea batatas Decne. at 1 KGray, 2.1 times for Trichosanthes kirilowii Max., and 2.8 times for Dioscorea batatas Decne. at 5 KGray. In ABTs free radical elimination activity, the activity increased 60 % for Terminalia chebula Retzius compared with untreated one. Besides, the beam-treated $IC_{50}$ value increased 2 times for Gray Ephedra sinica Stapf, 2.5 times for Terminalia chebula Retz. and 2.4 times for Arctium lappa Linne at 1 KGray.