• Title/Summary/Keyword: protocol conversion

Search Result 131, Processing Time 0.032 seconds

Implementation of an Internet Telephony Service that Overcomes the Firewall Problem (방화벽 문제를 극복한 인터넷 전화 서비스의 구현)

  • 손주영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.65-75
    • /
    • 2003
  • The internet telephony service is one of the successful internet application services. VoIP is the key technology for the service to come true. VoIP uses H.323 or SIP as the standard protocol for the distributed multimedia services over the internet environment, in which QoS is not guaranteed. VoIP carries the packetized voice by using the RTP/UDP/IP protocol stack. The UDP-based internet services cause the data transmission problem to the users behind the internet firewall. So does the internet telephony service. The users are not able to listen the voices of the counter-parts on the public internet or PSTN. It makes the problem more difficult that the internet telephony service addressed in this paper uses only one UDP port number to send the voice data of all sessions from gateway to terminal node. In this paper, two schemes including the usage of dummy UDP datagrams, and the protocol conversion are suggested. The implementation of one of the schemes, the protocol conversion, and the performance evaluation are described in detail.

A Study on the Protocol Conversion Method using Semantic Relation between Messages (메시지 의미관계를 이용한 프로토콜 변환 방법에 관한 연구)

  • 권운철;심영섭;이동호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.6
    • /
    • pp.1107-1114
    • /
    • 1994
  • This paper presents a method of constructing the protocol converter where the semantic relation between messages is added to the protocol conversion method satisfying with conformity property. This method comes from a formal method with top-down approach and then derives efficient maximal converter to overcome protocol mismatch between computer networks implemented with different protocols. When a converter is made with this method, the most useless portions of the maximal converter are removed easily.

  • PDF

The Development of Protocol for Construction of Smart Factory (스마트 팩토리 구축을 위한 프로토콜 개발)

  • Lee, Yong-Min;Lee, Won-Bog;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1096-1099
    • /
    • 2019
  • In this paper, we propose the protocol for construction of smart factory. The proposed protocol for construction of smart factory consists of an OPC UA Server/Client, a technology of TSN realtime communication, a NTP & PTP time synchronization protocol, a FieldBus protocol and conversion module, a technology of saving data for data transmit latency and synchronization protocol. OPC UA server/client is a system integration protocol which makes interface industrial hardware device and supports standardization which allows in all around area and also in not independent from any platform. A technology of TSN realtime communication provides an high sensitive time management and control technology in a way of sharing specific time between devices in the field of high speed network. NTP & PTP time synchronization protocol supports IEEE1588 standardization. A fieldbus protocol and conversion module provide an extendable connectivity by converting industrial protocol to OPC. A technology of saving data for data transmit latency and synchronization protocol provide a resolution function for a loss and latency of data. Results from testing agencies to assess the performance of proposed protocol for construction of smart factory, response time was 0.1367ms, synchronization time was 0.404ms, quantity of concurrent access was 100ea, quantity of interacting protocol was 5ea, data saving and synchronization was 1,000 nodes. It produced the same result as the world's highest level.

Integration Mechanism of SDL and CORBA System using Method/Signal Mapping Rules (메소드/시그널 매핑을 이용한 SDL과 CORBA 시스템의 통합 방법)

  • Paik, Eui-Hyun;Huh, Jae-Doo;Lee, Hyeong-Ho
    • The KIPS Transactions:PartA
    • /
    • v.9A no.4
    • /
    • pp.479-484
    • /
    • 2002
  • This paper presents the model that integrates an SDL system and a CORBA system using mapping rules between method and signal for developing embedded systems connected with internet. In order to support communication between the two different systems (SDL and CORBA), it is essential to secure the conversion interface between SDL communication protocol and CORBA communication protocol. In this paper, IDL is adopted for the communication interface and the conversion of the communication protocol between the two systems, and the IDL compiler automatically generates the interface for protocol interoperability. The proposed model adopts middleware on the subpart of the SDL based legacy system, and hence, supports the service on the distributed system, regardless of the environment and location of the server system.

A Design of Gateway for Industrial Communication (산업용 통신 게이트웨이 설계)

  • Eum, Sang-hee;Lee, Byong-hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.281-283
    • /
    • 2016
  • Recently, many industrial instruments face the problem of protocol compatibility with the external monitoring and control system. This paper is prepared in the main control board to support the industrial communication protocol conversion, control, and monitoring. The industrial communication gateway module is also designed to ensure that the protocol conversion of CAN bus and Ethernet. The main board processor is used the Atmega2560, and placed 4ea RS485 serial slots for sub-board. One of them is used for communication CAN bus and Ethernet. It provides analog and digital I / O through each of the slots is used for control and monitoring.

  • PDF

Development of User Protocol Converter about Modbus and NMEA0183 (Modbus와 NMEA0183에 대한 사용자 프로토콜 컨버터 개발)

  • Eum, Sang-hee;Hong, Sung-ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.11
    • /
    • pp.2584-2589
    • /
    • 2015
  • In this paper, we want to able to reduce the time effectively about the analysis of protocol and development of protocol converter in industrial network. For this purpose, we developed the user protocol converter that can be to analysing the communication protocol in the industrial network. and also that is able to converting to user protocol and transmitting to another network. The developed user protocol converter was consist of S/W and H/W, and is supporting the Modbus, the NMEA0183 and the ethernet. The hardware main processor was used the AVR128, and placed the serial communication part and the ethernet part in converter board. The experiment results, we acquired very high transmission rate and conversion rate.

The Crucial Role of the Establishment of Computed Tomography Density Conversion Tables for Treating Brain or Head/Neck Tumors

  • Yang, Shu-Chin;Lo, Su-Hua;Shie, Li-Tsuen;Lee, Sung-Wei;Ho, Sheng-Yow
    • Progress in Medical Physics
    • /
    • v.32 no.3
    • /
    • pp.59-69
    • /
    • 2021
  • Purpose: The relationship between computed tomography (CT) number and electron density (ED) has been investigated in previous studies. However, the role of these measures for guiding cancer treatment remains unclear. Methods: The CT number was plotted against ED for different imaging protocols. The CT number was imported into ED tables for the Pinnacle treatment planning system (TPS) and was used to determine the effect on dose calculations. Conversion tables for radiation dose calculations were generated and subsequently monitored using a dosimeter to determine the effect of different CT scanning protocols and treatment sites. These tables were used to retrospectively recalculate the radiation therapy plans for 41 patients after an incorrect scanning protocol was inadvertently used. The gamma index was further used to assess the dose distribution, percentage dose difference (DD), and distance-to-agreement (DTA). Results: For densities <1.1 g/cm3, the standard deviation of the CT number was ±0.6% and the greatest variation was noted for brain protocol conditions. For densities >1.1 g/cm3, the standard deviation of the CT number was ±21.2% and the greatest variation occurred for the tube voltage and head and neck (H&N) protocol conditions. These findings suggest that the factors most affecting the CT number are the tube voltage and treatment site (brain and H&N). Gamma index analyses for the 41 retrospective clinical cases, as well as brain metastases and H&N tumors, showed gamma passing rates >90% and <90% for the passing criterion of 2%/2 and 1%/1 mm, respectively. Conclusions: The CT protocol should be carefully decided for TPS. The correct protocol should be used for the corresponding TPS based on the treatment site because this especially affects the dose distribution for brain metastases and H&N tumor recognition. Such steps could help reduce systematic errors.

Design and Implementation of a Generic Interface Adaptor for Network Management based on TINA (TINA 체계의 망관리를 위한 Generic Interface Adaptor의 설계 및 구현)

  • 이계환;김영탁
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.10A
    • /
    • pp.1717-1726
    • /
    • 2001
  • 본 논문에서는 CORBA(Common Object Request Architecture)기반의 TINA(Telecommunications Information Networking Architecture) 분산체계에서 통신망 하부 장비들이 SNMP(Simple Network Management Protocol) 혹은 TMN(Telecommunications Management Network) 체계로 혼재되어 관리되는 네트워크의 NE(Network Element)들을 효율적으로 통합 관리할 수 있는 Generic Interface Adaptor(GIA)를 제안하고 이를 설계 및 구현하였다. GIA는 message mapping, protocol conversion 및 DBMS를 이용한 Object Abstract Translation(OAT)을 통해서 각 관리체계에 맞도록 관리정보를 변환시키며, 이를 통해 TINA EML(Element Management Layer) component와 SNMP NE agent 간의 상호연동을 가능하게 한다.

  • PDF

DATA LINKS BETWEEN EMS AND SCADA SYSTEMS (EMS - SCADA 자료연계)

  • Lee, Kyung-Jae;Yu, Sung-Chul;Kim, Yeong-Han;Lee, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.109-113
    • /
    • 1987
  • This paper briefly introduces a strategy of data links between EMS and SCADA systems for the KEPCO's EMS project. For the data links, front end/communication processors are adopted that provide for protocol conversion and communication processing in parallel with EMS/SCADA processing. The data link configuration for a communication channel is point to point links. The EMS - hardware and software - has capability of handling links utilizing both bisync protocol and X.25 (Level 1 and 2)protocol for the data link protocol.

  • PDF

A New Data Link Protocol for Railway Signaling Systems

  • Hwang, Jong-Gyu;Lee, Jae-Ho;Park, Yong-Jin;Park, Gwi-Tae
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.4
    • /
    • pp.195-201
    • /
    • 2003
  • In accordance with the computerization of railway signaling systems, the interface link between signaling equipment has been replaced by a digital communication channel and the importance of this communication link has become increasingly significant. However, there are some problems with the present state of railway signaling. First, different communication protocol is applied to interfaces between signaling although they have the same functions. Next, the communication protocols currently used in the railway fields contain various illogical components such as structure, byte formation, error correction scheme and so on. To solve these matters, a new data link protocol for railway signaling systems is designed. In this paper, the structure of protocol and the results of performance analyses are presented. It will be expected to increase the safety, reliability and efficiency of maintenance of signaling systems by using the designed communication protocol for railway signaling in Korea.