• Title/Summary/Keyword: protocol conversion

Search Result 131, Processing Time 0.028 seconds

Design of Communication Protocol Conversion using EPN (EPN을 이용한 통신프로토콜 변환방식 설계)

  • 이상호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.4
    • /
    • pp.509-518
    • /
    • 1993
  • Protocol conversion is to resolve the imcompatibility between networks so that users on different protocols can communicate with each other. This paper designs a formal model, EPN , to increase its modeling power and analyze conversion protocol and proposes a conversion algorithm using it. The conversion algorithm has two capabilities : synchronization and automatic error recovery function. Therefore burden of protocol converter design will be reduced, automatic protocol converter design can be possible and implementation for half-gateway will be easy.

  • PDF

A Protocol Conversion Algorithm for Industrial Monitoring (산업용 모니터링을 위한 프로토콜 변환 알고리즘)

  • Eum, Sang-hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.236-237
    • /
    • 2017
  • Recently, many industrial instruments face the problem of protocol compatibility with the external monitoring and control system. This paper implemented a protocol conversion algorithm for industrial monitoring about communication Data. This algorithm is supported programmable method by user. we experimented the protocol conversion by communication gateway module using implemented algorithm, and obtained good results.

  • PDF

A Protocol Conversion Algorithm for Monitoring of Industrial Communication Data (산업용 통신 데이터의 모니터링을 위한 프로그램 가능한 프로토콜 변환 알고리즘)

  • Eum, Sang-hee;Lee, Byong-hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.283-284
    • /
    • 2016
  • Recently, many industrial instruments face the problem of protocol compatibility with the external monitoring and control system. This paper implemented a protocol conversion algorithm for monitoring of industrial communication Data. This algorithm is supported programmable method by user. we experimented the protocol conversion by communication gateway module using implemented algorithm, and obtained good results.

  • PDF

Data Conversion and Transmission Method for heterogeneous industrial device communication (이기종 산업기기 통신을 위한 데이터 변환 및 전송 방법)

  • Eum, Sang-hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.277-278
    • /
    • 2017
  • Recently, many industrial instruments face the problem of protocol compatibility with the external monitoring and control system. This paper implemented a protocol conversion algorithm for industrial monitoring about communication Data. This algorithm is supported programmable method by user. we experimented the protocol conversion by communication gateway module using implemented algorithm, and obtained good results.

  • PDF

Effect of dark incubation in germination of indirect date palm somatic embryos and conversion into plantlets

  • Mansour Abohatem;Yousra Al-Qubati;Hanan Abohatem
    • Journal of Plant Biotechnology
    • /
    • v.50
    • /
    • pp.267-274
    • /
    • 2023
  • All studies on date palm somatic embryogenesis have focused on germination in the presence of light while neglecting germination in darkness, which mimics the germination process of zygotic embryos within seeds. To improve the date palm micropropagation protocol, we investigated the effects of light and darkness incubation on the germination of indirect date palm somatic embryos and their subsequent conversion into plantlets. Darkness incubation emerged as a pivotal factor in the germination of indirect date palm somatic embryos and their successful conversion into plantlets. Darkness incubation significantly decreased the time required for the conversion of indirect somatic embryos into plantlets, halving the duration from 24 weeks to only 12 weeks. The micropropagation protocol was modified, consolidating the previous two distinct stages of germination and elongation under light incubation into a single stage under darkness incubation. These findings modified the protocol and significantly reduced the overall duration of the date palm micropropagation protocol.

A Study on Development of Conversion Software for Controller Without OPC Stack to Communicate With OPC DA Client (OPC 스택이 없는 제어기와 OPC DA 클라이언트를 통신시키는 변환 소프트웨어 개발에 관한 연구)

  • Lee, Yong-Min;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.19 no.3
    • /
    • pp.319-326
    • /
    • 2015
  • This paper proposes method about development of conversion software for controller without OPC stack to communicate with OPC DA client. The proposed method is composed of development of OPC server based on OPC DA standard protocol, development of GUI application can be checked the OPC tag and point informations, development of conversion module to convert from OPC protocol to open standard protocol. In the stage of development of OPC server based on OPC DA standard protocol, we develope server in the pc to transmit and receive datum through OPC DA protocol with OPC DA client. In the stage of evelopment of GUI application can be checked the OPC tag and point informations, run the OPC DA server and register to window system registry and check OPC tags, points, transmitting and receiving of data from serial communication. In the stage of development of conversion module to convert from OPC protocol to open standard protocol, convert from OPC tag data which has received from OPC DA client to protocol can be communicated with industrial controller using open standard protocol so that support to transmit and receive data. To evaluate the efficiency of the proposed software, we connected OPC DA server software and OPC client, and 5 sample industrial controller which use open standard protocol, as a result we got 96.98% average communication succeeding rate among entire transmitting and receiving packets. We also confirmed that successfully communicated between industrial building controller which uses modbus protocol and industrial OPC DA client using OPC DA conversion software proposed by this dissertation.

A Programmable Protocol Data Conversion Algorithm for Industrial Machine Monitoring (산업용 장비 모니터링을 위한 프로그램 가능한 프로토콜 데이터 변환 알고리즘)

  • Eum, Sang-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.11
    • /
    • pp.2139-2144
    • /
    • 2017
  • In case of communication method and protocol applied to the industrial field, various kinds and methods are applied to the field according to the environment and hardware configuration specifications. In order to develop and construct an industrial monitoring system, the development of the equipment is carried out through hardware system analysis and communication protocol analysis each time, so that a lot of development costs and time are being entered. In this paper, we proposed a programmable protocol conversion algorithm to support the integrated monitoring of industrial equipment using various protocols. This method can extract the necessary data from the data transmitted by serial communication, NMEA, CAN, Modbus communication method and transmit it to Ethernet. We implemented a communication gateway module that supports various communication methods, and experimented with data conversion and transmission.

Research on Protocol Conversion Gateway based on IEEE1815.1 (IEEE 1815.1 기반 이기종 프로토콜 변환 게이트웨이 기술 연구)

  • Lee, Seokjun;Kwon, Sungmoon;Shon, Taeshik;Park, Sungwan
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.5
    • /
    • pp.1201-1209
    • /
    • 2016
  • While the legacy electric grid evolving into the smart grid, various communication standards have been used for interoperability between many components. In this situation, the needs emerged for protocol conversion and mapping method for connecting the outside components to the operation center. In this paper, according to the surge of IEC 61850-based substation automation, we studied the protocol conversion gateway for linking legacy DNP3-based control center and IEC 61850-based substation automation. This paper is based on the IEEE 1815.1 standard for the protocol mapping. We suggested the direction of development the gateway and developed prototype for evaluate the proposed gateway. Also, we bring up a security problem and give a solution.

An Industrial monitoring board design with support for multiple communications (다양한 통신을 지원하는 산업용 모니터링 보드 설계)

  • Eum, Sang-hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.197-199
    • /
    • 2018
  • Recently, many industrial instruments face the problem of protocol compatibility with the external monitoring and control system. This paper is prepared in the main control board to support the industrial communication protocol conversion, control, and monitoring. The industrial communication gateway module is also designed to ensure that the protocol conversion of CAN bus and Ethernet. The main board processor is used the Atmega2560, and placed 4ea RS485 serial slots for sub-board. One of them is used for communication CAN bus and Ethernet. It provides analog and digital I / O through each of the slots is used for control and monitoring.

  • PDF

SDL-OPNET Model Conversion Technique for the Development of Communication Protocols with an Integrated Model Design Approach (통합 모델 설계 방식 기반 통신 프로토콜 개발을 위한 SDL-OPNET 모델 변환 기법)

  • Kim, Jae-Woo;Kim, Tae-Hyong
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.5 no.2
    • /
    • pp.67-76
    • /
    • 2010
  • Although both functional verification and performance evaluation are necessary for the development of effective and reliable communication systems, they have been often performed independently; by functional modeling with formal language tools and by performance modeling with professional network performance evaluation tools, respectively. Separate and repeated modeling of one system, however, would often result in cost increase and inconsistency between the models. This paper proposes an integrated model design approach in order to overcome this problem that evaluates the performance of a communication protocol designed in SDL with SDL-OPNET model conversion. The proposed technique generates OPNET skeleton code from Tau-generated C code of the SDL model by analyzing the relations between SDL and OPNET models. IEEE 802.2 LLC protocol was used as an example of model conversion to show the applicability and effectiveness of the proposed technique.