• Title/Summary/Keyword: protector

Search Result 324, Processing Time 0.041 seconds

154KV 전력계통 직접접지시통신선 유도장애에 관한 실험적 연구 3

  • 장상현;김봉업;김용배
    • 전기의세계
    • /
    • v.16 no.5
    • /
    • pp.51-62
    • /
    • 1967
  • Relay Protector의 자체특성시험을 한 다음 대전-이리, 대구-상주, 대구-진영 간의 154KV 송전선과 이를 인접역행하는 통신선에 Relay Protector를 취부하고 이 구간의 154KV 송전선을 직접접지한 후에 실제로 인공고장을 이르켜 Relay Protector의 성능실험을 하였다.

  • PDF

Investigation of Reducing Characteristics for the Spreading of Dredging Soil and the Diffusion of Contaminant by Silt Protector Curtain through Three Dimensional Numerical Model Experiment (3차원 수치모형실험을 통한 오탁방지막의 오염물질 및 준설토 확산 저감특성 조사)

  • Hong, Nam-Seeg
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.78-85
    • /
    • 2010
  • This study investigates reducing characteristics for the spreading of dredged soil and the diffusion of contaminant by silt protector curtain through three dimensional numerical experiment. The numerical medel is modified by combining the sediment transport characteristics for cohesive sediment into the previously developed model. Several numerical experiments have been given in order to investigate the reducing effect of silt protector using two dimensional numerical channel model under various parameters such as upstream flow velocity, depth of silt curtain and the position of dumped materials. Through the evaluation of several simulation results, we knew that the careful design has to be given in the determination of depth and position of silt protector.

A study on contaminant reduction performance of the adsorption protector for construction surface (흡착보양재의 오염물질방출 저감성능에 관한 연구)

  • Heo, Jung-Yong;Choi, Chang-Ho;Lee, Yun-Gyu
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.714-719
    • /
    • 2008
  • In a domestic construction field, after floor is constructed, protector for construction surface is set up to prevent the surface of the floor being scratched and polluted. However, the problem is that contaminants discharged with the removal of the protector for construction surface exert a bad influence for the indoor air quality. In the research, it tested to the contaminant reduction performance of the adsorption protector for construction surface using powder of charcoal by the alternative proposal of such protectors for construction surface

  • PDF

Relationship between the Impact Value of Electronic Body Protector and the Impact Force of Force Platform in the Taekwondo (태권도의 전자호구 충격값과 포스플랫폼 충격력과의 관련성)

  • Bae, Young-Sang
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.2
    • /
    • pp.125-130
    • /
    • 2013
  • Although the electronic body protector has been officially adopted by the World Taekwondo Federation(WTF) in 2006, no scientific information is available about the reliability of its performance. The purpose of this study, therefore, was to investigate the relationship between the impact value of electronic body protector and the impact force of force platform. Male collegiate Taekwondo athletes([MCTA], n=21) and male collegiate Taekwondo students([MCTS], n=20) volunteered to participate in the study. Each subject performed the apchagi, dollyeochagi and dwichagi on the force platform and the electronic body protector. At the apchagi, it showed that MCTS(about 4,700 N) generated more maximum kick force than MCTA(about 3,900 N), but it expressed that MCTA(about 5,300 N) generated more maximum kicking force than MCTS(about 4,400 N) at the dwichagi. At the apchagi and the dwichagi, it indicated the high coefficient of correlation(over r=.8) which supports higher explanation force the relationship between the impact value of electronic body protector and the impact force of force platform, but there was no statistically significant difference at the dollyeochagi.

Wearing Characteristic Evaluation of Hip Protector for Hip Fracture Prevention (고관절 골절 예방을 위한 힙프로텍터 착용특성 평가)

  • Jeon, Eun-Jin;Park, Sei-Kwon;You, Hee-Cheon;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.16 no.6
    • /
    • pp.1001-1007
    • /
    • 2014
  • We surveyed the wearing characteristics of hip protectors. The problems of existing hip protectors were identified and the directions for improvement were presented. The evaluation of wearing characteristics was conducted on the 100 elderly women (60 to 85 years) with 5 types of hip protector. The questionnaire was composed of history and characteristics on falling, hip protector acceptance, preference, use characteristics and improvement requirements. The result of wearing characteristic evaluation indicated that 52% of the subject experienced falling in winter. Incidents resulting from falling occurred: outdoors (74.5%), bathroom (10.9%), and kitchen (5.5%). Body parts to be protected were in several areas: 35.6% for lumbar, 26.9% for hip joint, and 15% for hip bone. Participants prefer a belt B type design at a rate of 56.9% because it provided a sense of stability by clinging to the body and upholding the waist. Belt B type was the most appropriate in terms of fit, allowance, mobility, and design except pad thickness. To reduce the risk of hip fracture, hip protector needs to be designed in consideration of user's type of fall and body shape. The pattern and size of a hip protector has to be improved in regards to the amount of discomfort. An objective evaluation is needed for the ergonomic design of a hip protector based on and analysis of 3D body image of the elderly and the shock-absorbing quality of pad.

Tongue-Lip Adhesion Using an Alveolar Protector Appliance for Management of Pierre Robin Sequence (피에르 로빈 연속증의 치료로써 치조 보호 장치를 이용한 혀-하순 유착술)

  • Lee, Jang-Won;Park, Beyoung-Yun
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.547-551
    • /
    • 2011
  • Purpose: Pierre Robin sequence is a congenital malformation in which micrognathia causes glossoptosis and airway obstruction. If conservative treatment fails, surgical procedures such as tongue-lip adhesion can be performed. However, this procedure remains a subject of debate, with favorable results being countered by reports of complications. To overcome the above limitations, we revised the traditional method of tongue-lip adhesion using an alveolar protector. Methods: Between 1992 and 2011, a total of eight patients were identified with Pierre Robin sequence and were treated with tongue-lip adhesion. Two of these eight tongue-lip adhesion procedures were performed with an alveolar protector. The operative technique for tongue-lip adhesion was similar to that described in other published reports. The alveolar protector was inserted between the ventral surface of the tip of the tongue and the lower labial sulcus. Results: Tongue-lip adhesion failed in two patients because of wound dehiscence. The primary surgical success rate was 66.7%. In the two tongue-lip adhesion procedures performed with the alveolar protector, we observed no postoperative complications. Conclusion: Resistance to traction of the tongue can be encountered with nonunionized symphysis menti, causing loosening of the traction suture through the symphysis menti. This can lead to backward positioning of tongue, resulting in dehiscence of tongue lip adhesion. The alveolar protector is a good adjunct to tongue-lip adhesion because this method avoids postoperative loosening of the traction suture and wound dehiscence. It is a simple and effective auxiliary method that yields functional improvement.

Analysis of Protection Capability of a Conical Shaped Protector (유한요소해석을 이용한 원뿔형 대응체 방호 효과 분석)

  • Kim, Heecheol;Kim, Jongbong;Jeong, JinHwan;Yoo, Yo-Han
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.563-571
    • /
    • 2018
  • In order to effectively protect a penetrator, the conically shaped protector was proposed and the protection capability was investigated. The collision and penetration of the penetrator with the protector were analyzed using dynamic finite element analysis. The post impact behaviors of the penetrator, i.e., flying velocity and the change of attitude angle, were monitored to investigate the protection capability. The flying velocity and the attitude angle are used to investigate the deviation and the penetration power respectively. The effect of rotation speed of the protector and the collision position on the protection capability is investigated in the viewpoint of deviation and attitude angle when penetrator colliding with our tank.

An Experimental Analysis of the Impact of Green Water on Offshore Platforms with Green Water Protectors of Various Shapes

  • Lee, DongHyun;Jeon, MyungJun;Nguyen, Van Minh;Yoon, Hyeon Kyu
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.2 no.3
    • /
    • pp.136-149
    • /
    • 2016
  • Green water impact occurs frequently on offshore platform due to waves with a height greater relative to the freeboard of the structure. This phenomenon exerts a large impact load on the deck. In this paper, offshore platform models with green water protectors of various shapes were fixed to the center of a 3D wave tank to measure the impact pressure acting on the various points on deck and protectors. The impact pressure distribution differed depending on the protector shape, and various patterns of wave creeping up the protector were observed. The protector shape that exerted the lowest pressure impact on the deck will be useful in the deck design of offshore platform, and the model test results will be expected to be used for designers to select the best protector form.