• Title/Summary/Keyword: protective performance

Search Result 510, Processing Time 0.021 seconds

Performance Improvement of Protective Relaying for Large Transformer by Using Voltage-Current Trend and Flux-Differential Current Slope Characteristic (전압-전류 추이와 자속-차전류 기울기 특성을 이용한 변압기 보호계전기법의 성능 개선)

  • Park, Chul-Won;Park, Jae-Sae;Jung, Yun-Man;Ha, Kyung-Jae;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.2
    • /
    • pp.43-50
    • /
    • 2004
  • Percentage differential characteristic relaying(PDR) has been recognized as the principal basis for power transformer protection. Second harmonic restraint PDR has been widely used for magnetizing inrush in practice. Nowadays, relaying signals can contain 2nd harmonic component to a large extent even in a normal state, and 2nd harmonic ratio indicates a tendency of relative reduction because of the advancement of material. Further, as the power system voltage becomes higher and more underground cables are used, larger 2nd harmonic component in the differential current under internal fault is observed. And then, conventional 2nd harmonic restraint PDR exposes some doubt in reliability. It is, therefore, necessary to develop a new algorithm for performance improvement of conventional protective relaying. This paper proposes an advanced protective relaying algorithm by using voltage-current trend and flux-differential current slope characteristic. To evaluate the performance of the proposed algorithm, we have made comparative studies of PDR, fuzzy relaying and DWT relaying. The paper is constructed power system model including power transformer, utilizing the WatATP, and data collection is made through simulation of various internal faults and inrush. As the results of test, the new proposed algorithm was proven to be faster and more reliable.

Development and/or Characteristics Evaluation of High Performance SPD(Surge Protective Device) (고성능 서지보호 시스템 개발 및 성능 평가)

  • Kim, Jae-Hoon;Kim, Ju-Han;Han, Sang-Ok;Kim, Sun-Ho;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.328-333
    • /
    • 2009
  • In this paper, we have developed high performance SPD(surge protective device) and evaluated the characteristics in comparison with typical SPD used in the inside and outside of the country. The new SPD was composed of MOV(metal oxide varistor), GDT(gas discharge tube) and impedance such as resistors, capacitors or varistors. To estimate operating the characteristic of the SPD which was developed, it was measured surge voltage caused by fault current or surge according to IEC 61000-4-5. As a result it was found that the power supply was cut off by high performance SPD when caused a short-circuit. In addition we could know that it could prevent ELB(earth leakage breaker)'s malfunction caused by surge.

Dispersant Effect on Thermal Performance of SG (증기발생기 열성능에 미치는 분산제 첨가효과)

  • Lee, Jae-Keun;Moon, Jeon-Soo;Yoon, Seok-Won;Maeng, Wan-Young
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.4
    • /
    • pp.546-551
    • /
    • 2011
  • The corrosion on steam generator tubes of the secondary side of pressurized water reactor inhibits heat transfer. One of the most efficient techniques improving the heat transfer performance of a nuclear electric generation is a corrosion control. The environmental parameters mostly affecting corrosion are materials and chemical additives. It seems that no further corrosion occurs in steels with Polyacrylic acid polymer dispersant treatment. Polyacrylic acid forms a protective coating with uniform thickness on metal surface. Polyacrylic treatment appears to be the most convenient way to enhance the thermal performance by the thermal conductivity improvement in steam generators.

Protective Devices Allocation Optimization for Electrical Distribution System

  • Bupasiri, Rosawan;Wattanapongsakorn, Naruemon;Hokierti, Jamnarn
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.433-436
    • /
    • 2002
  • Most of electric distribution utilities have their reliability performance measured by reliability indices such as SAIFI and SAIDI to evaluate customer satisfaction. Adding protective devices in electrical distribution system can increase the system reliability by protecting public customers from local faults. In large-scale distribution system, it is difficult to determine the positions of these protective devices, which can efficiently protect customers within utilities' investment. In this paper, we propose an optimization technique to identify types and positions of protective devices to minimize SAIFI and SAIDI indices according to system requirement constraints.

  • PDF

The Study of Fast Frequency Measurement Technique for Protection Relay (계전기를 위한 고속의 주교수 계측 알고리즘)

  • Kim, Beung-Jin;Lee, Chang-Ho;Park, Jong-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.211-213
    • /
    • 2005
  • In this paper, the frequency compensator for digital protective relay is introduced. Due to sudden appearance of generation-load or fault in power system, the frequency can deviate from its nominal value. The Orthogonal filter adopted to digital protective relay is exposed to the problem. Therefore, the frequency variation makes a difficult to protective function and power measurement in digital protective relay. The essential property of the proposed algorithm presented is its outstanding immunity to both signal orthogonal component magnitudes and DFT filter gain variations which ensures below 0.05Hz accuracy of estimation. Additionally, the proposed method has excellent characteristics with low signal sampling rate. Based on the frequency estimation, author design under frequency protection relay for generator and verifies its performance with several experimental tests.

  • PDF

Mechanical Performance Study of Piggy Back Clamp for Submarine Cables (해저케이블용 피기백 클램프의 기계적 성능 연구)

  • Yun Jae Kim;Kyeong Soo Ahn;Jin-wook Choe;Jinseok Lim;Sung Woong Choi
    • Composites Research
    • /
    • v.37 no.2
    • /
    • pp.108-114
    • /
    • 2024
  • Due to the continuously increasing global demand for electricity, the demand for high-voltage submarine cables is also increasing. One of the issues that need to be addressed for submarine cables is the high production cost and expensive laying costs. Submarine cables exposed to the marine environment encounter external forces such as wave and current, leading to issues such as cable damage due to external factors or high maintenance costs in the event of an accident. Therefore, we are preparing for the uncertainty of the submarine environment through many protective materials and protective equipment. In this study, we examined the bending performance of piggyback clamps (PBC) and strap, which are representative protective equipment, in response to the submarine environment through analytical methods. To examine the structural performance of PBC, the bending performance were assessed under the maximum bending moment criterion of 15 kN·m for the flexible protection tube. As a result, it was confirmed that the structural performance regarding the bending moment of both PBC and straps was ensured.

Nursing Students' Awareness and Performance on Standard Precautions of Infection Control in the Hospital (간호대학생의 병원감염관리 표준주의에 대한 인지도와 수행도)

  • Hong, Sun-Yung;Kwon, Young-Sook;Park, Hee-Ok
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.18 no.2
    • /
    • pp.293-302
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate nursing students' awareness and performance on standard precautions and to provide meaningful information for nursing students' education regarding hospital infection control. Method: Four hundred forty seven nursing students at 6 universities in D-city participated in this study. Data collection was conducted from March to April 2011. Students' awareness and performance on standard precautions of infection control in hospitals were measured using the modified 2007 CDC standard precautions guidelines. Data analysis was performed using the SPSS WIN 18.0 program, descriptive statistics, t-test, and ANOVA. Results: The level of students' awareness in the standard precautions was higher than performance. The higher levels of students' awareness and performance on standard precautions included patient care equipment, safe injection practices, and worker safety. The lower levels of students' awareness and performance on standard precautions included hand hygiene and personal protective equipment. There was no difference in the students' awareness and performance of standard precautions according to their characteristics. Conclusions: Based on the findings of this study, hand hygiene and personal protective equipment need to be stressed more within the program to improve nursing students' infection control techniques.

Paramedic students' awareness and performance of infection control on ambulance attendant training (응급구조학과 학생들의 구급차 동승실습 중 감염관리에 대한 인지도 및 수행도)

  • Lee, Hyun-Ju;Lee, Kyoung-Youl
    • The Korean Journal of Emergency Medical Services
    • /
    • v.20 no.2
    • /
    • pp.21-35
    • /
    • 2016
  • Purpose: This study aims to investigate awareness and performance of infection control during ambulance attendant training, and to provide basic data for infection control. Methods: The subjects were 235 paramedic students who completed ambulance attendant training. There were 51 questions. The infection control dimension was divided into hand washing, personal protective equipment use, and environmental management, for each sub-dimension, awareness and performance were measured by a 4-point scale. The collected data were analyzed using SPSS statistics ver. 22.0. Results: A total of 95.3%, of the subjects completed an orientation for ambulance attendant training and 71.7% received education on infection. In all three sub-dimensions, hand- washing (p<.001), personal protective equipment use (p<.001), and environmental management (p<.001), awareness scored higher than performance. The awareness of infection control showed a significantly positive correlation (r=.394) with performance. Conclusion: In order to improve performance of infection control, education to improve awareness should be provided, and paramedics with higher performance levels in hand washing, and use of gloves and masks wearing should be assigned as training advisors.

Testing Investigation of Protective Coatings for Downhole Oil Tube

  • Zhang, Liping;Zhang, Qibin;Zhang, Yanjun;Xie, Beibei;Zhang, Yingying
    • Corrosion Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.13-15
    • /
    • 2008
  • Aiming at the corrosion circumstances and corrosion prevention needs of downhole oil tubes, series protective coatings for downhole oil tubes have been developed in the authors' laboratory, including a baked type coating YG-01 and an air curing type coating YG-03, etc. The performance investigation of the coatings has been done for testing their corrosion resistance, mainly including salt fog test, immersion test in oil-field waste water and various acid solutions, high temperature and high pressure test in alkali solution or $H_2S/CO_2$ environment, as well as some other performances. The investigation results show that oil tube anti-corrosion coatings developed here can endure over 4000 hrs salt fog test, over 1000 hrs immersion in various acid solutions at room temperature and in boiling oil-field waste water. In addition, the coatings can keep intact after experiencing test in alkali solution under 70 MPa pressure at $150^{\circ}C$ for 24 hrs, and in simulative sour gas environment under the total pressure of 32 MPa ($P_{H_{2}S}=3.2MPa$, $P_{CO_{2}}=3.2MPa$) at $90^{\circ}C$ for 168 hrs, which show that the coatings can be used for corrosion prevention in downhole environments with specific high temperature and high pressure, such as sour gas wells. The other testing results show the oil tube protective coatings have excellent comprehensive performance.

Protective Ability Index of Rust Layer Formed on Weathering Steel Bridge

  • Hara, S.;Kamimura, T.;Miyuki, H.;Yamashita, M.;Uchida, H.
    • Corrosion Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.128-132
    • /
    • 2007
  • For a quantitative inspection on the performance of weathering steel bridges, we have investigated the relationship between the corrosion rate and the composition of the rust layers formed on weathering steel bridges located in various environments in Japan and applied a protective ability index (PAI) to the bridges. The corrosion rates were clearly classified by the PAI, ${\alpha}/{\gamma}*$ and sub index of $({\beta}+s)/{\gamma}*$, where $\alpha$, \gamma*, $\beta$ and s are the mass ratio of crystalline $\alpha-FeOOH$, the total of $\gamma$-FeOOH+ $\beta$-FeOOH + the spinel-type iron oxide (mainly $Fe_3O_4$), $\beta-FeOOH$ and spinel-type iron oxide, analyzed by powder X-ray diffraction, respectively. In the case of ${\alpha}/{\gamma}$*>1, the rust layer works protective enough to reduce the corrosion rate less than 0.01 mm/y. The sub index $({\beta}+s)/{\gamma}*$<0.5 or >0.5 classifies the corrosion rate of the non-protective rust layers, therefore the former state of the rust layer terms inactive and the latter terms active. The quantitative inspection of a weathering steel bridge requires a performance-inspection (PI) and periodical deteriorationinspections (DI). The PI can be completed by checking of the PAI, ${\alpha}/{\gamma}*$. The DI on the weathering steel bridges where deicing salt is sprinkled can be performed by checking the PAI, $({\beta}+s)/{\gamma}*$.