• 제목/요약/키워드: protection wall

검색결과 283건 처리시간 0.031초

Research on no coal pillar protection technology in a double lane with pre-set isolation wall

  • Liu, Hui;Li, Xuelong;Gao Xin;Long, Kun;Chen, Peng
    • Geomechanics and Engineering
    • /
    • 제27권6호
    • /
    • pp.537-550
    • /
    • 2021
  • There are various technical problems need to be solved in the construction process of pre-setting an isolation wall into a double lane in the outburst prone mine. This study presents a methodology that pre-setting an isolation wall into a double lane without a coal pillar. This requires the excavation of two small section roadways to dig a wide section roadway, followed by construction of the separation wall. During this process the connecting lane is reserved. In order to ensure the stability of the separation wall, the required bearing capacity of the isolation wall is 4.66 MN/m and the deformation of the isolation wall is approximately 25 cm. To reduce the difficulty of implementing support the roadway is driven by 5 m/d. After the construction of the separation wall, the left side coal wall is brushed 1.5 m to make the width of the gas roadway reach 2.5 m and the roadway support utilizes anchor rod, ladder beam, anchor cable beam and net configuration. During construction, the concrete pump and removable self-propelled hydraulic wall mold are used to pump and pour the concrete of the isolation wall. In the process of mining, the stress distribution of coal body and isolation wall is detected and measured on site. The results demonstrate that the deformation of the surrounding rock of roadway and separation of roof in the roadway is small. The stress of the bolt and anchor cable is within equipment tolerance validating their selection. The roadway is well supported and the intended goal is achieved. The methodology can be used for reference for similar mine gas control.

$CO_2$소화제 노즐과 벽간 거리의 영향 (The Effect of the Distance Between $CO_2$ Agent Nozzle and Wall)

  • 박찬수
    • 한국화재소방학회논문지
    • /
    • 제18권4호
    • /
    • pp.27-34
    • /
    • 2004
  • CO₂소화장치의 CO₂노즐과 방호공간 내 벽 사이의 거리변화에 따른 유동 및 CO₂질량전달효과를 분석하기 위하여 CO₂노즐과 후측 벽 사이의 거리를 변화시키면서 전산모이실험을 3차원 비정상상태로 수행하였다. 유동장과 CO₂소화제 농도장을 계산하였다. CO₂노즐과 후측 벽 사이의 거리 증가에 따라 다른 재 순환 유동형태와 벽면제트기류가 형성되었다. CO₂ 소화제 질량전달은 모든 경우에서 각 벽으로부터 방호공간의 중앙으로 일어나지만 CO₂소화제 노즐의 전 후 영역의 CO₂질량분율은 CO₂노즐과 벽 사이의 거리 증가에 따라 높거나 낮게 나타났다.

MONTE CARLO SIMULATION FOR CORRECTION OF IONIZATION CHAMBER WALL

  • Kurosawa, Tadahiro;Takata, Nobuhisa;Koyama, Yasuji
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.271-273
    • /
    • 2001
  • In precise measurement of air kerma with cavity ionization chambers, the effect of wall attenuation and scatter are corrected by Kwall and that of nonuniformity by Knu. Using the EGS4 code, we calculated these two correction factors. Correction factors calculated for two different-sized cylindrical ionization chamber differ by up to 0.7% from those obtained by measurements.

  • PDF

The Importance of Corrosion Control and Protection Technology in the Refinery

  • Kim, Byong Mu;Oh, Sung Lyong
    • Corrosion Science and Technology
    • /
    • 제6권3호
    • /
    • pp.112-119
    • /
    • 2007
  • This paper presents the importance of corrosion control and protection technology with a real case study of heater tube rupture damaged by High temperature H2S-H2 corrosion in the refinery. The heater was operated at the Hydrocracking unit and the operation temperature and pressure was $340^{\circ}C$ and $18kg/cm^{3}$ respectively. Top side of the convection tube was thinned by high temperature hydrogen sulfide and hydrogen gas as a uniform corrosion and finally ruptured under operation pressure. Damaged area (Convection tube zone) was blocked by protection wall, so it was impossible to inspect with conventional nondestructive examination. Instead the elbow area which is out of the protection wall was inspected regularly to evaluate the corrosion rate of convection tube indirectly. However the operation temperature and the phase of the process stream was different between inside the chamber and outside the chamber. As a result, it caused severe corrosion to the horizontal convection tube inside the chamber comparing to the elbow outside the chamber. Finally convection tube was corroded more rapidly than the elbow and ruptured after 13 years operation. Because of the rupture, the heater was totally burned and the operation was stopped for 3 months until it has been reconstructed. To prevent this kind of corrosion problem and accident, corrosion control should be strengthened and protection technology should be improved.

식생블록옹벽의 구조적 안전성 해석과 보강설계기법 연구 (Development of Strengthening Method and Safety Analysis of Ecological Block and Vegetation Bank Protection)

  • 오병환;조인호;이영생;이근희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권1호
    • /
    • pp.207-215
    • /
    • 2003
  • Developed is a new environment-friendly concrete-block retaining wall system. The conventional analysis methods are not directly applicable because the proposed concrete-block wall system is made of by interlocking the blocks with shear keys. Therefore, the shear analysis as well as stability analysis have been conducted to secure the safety of block-wall system. Overall slope stability analysis was also performed. An appropriate strengthening method was developed to ensure the safety when the block-wall system is relatively high. The method of analysis for strengthening the concrete-block wall system was also proposed. The proposed environment-friendly concrete block retaining wall system shows reasonable safety and can be a good construction method for retaining walls and river bank walls.

CHEST WALL THICKNESS MEASUREMENTS AND THE DOSIMETRIC IMPLICATIONS FOR MALE RADIATION WORKERS AT THE KAERI

  • Lee, Tae-Young;Lee, Jong-Il;Chang, Si-Young;Kim, Jong-Kyung
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.299-303
    • /
    • 2001
  • Using ultrasound techniques, the Korea Atomic Energy Research Institute has measured chest wall thicknesses of a group of male workers at the Korea Atomic Energy Research Institute. A site-specific biometric equation has been developed for these workers. Chest wall thickness is an important modifier on lung counting efficiency. These data have been put into the perspective of the ICRP recommended dose limits for occupationally exposed workers: 100 mSv in a 5-year period with a maximum of 50 mSv in anyone year. For measured chest wall thicknesses of 1.9 cm to 4.1 cm and a 30 min counting time, the achievable MDAs for natural uranium in the KAERI lung counter vary from 5.75 mg to 11.28 mg. These values are close to, or even exceed, the predicted amounts of natural uranium that will remain in the lung (absorption type M and S) after an intake equal to the Annual Limit on Intake corresponding to a committed dose of 20 mSv. This paper shows that the KAERI lung counter probably cannot detect an intake of Type S natural uranium in a worker with a chest wall thickness equal to the average value (2.7 cm) under routine counting conditions.

  • PDF

제상 히터와 냉장고 플라스틱 내벽 사이의 안전거리에 대한 모델링 (Modeling of the Safety Distance between Defrost Heater and Plastic Inner Wall of Refrigerator)

  • 정영;신종민
    • 설비공학논문집
    • /
    • 제15권3호
    • /
    • pp.196-202
    • /
    • 2003
  • Two dimensional modeling was carried out to find the safety distance between the defrost heater and the plastic inner wall of domestic refrigerator Estimation was processed for the three cases; the estimation of plastic wall temperature (1) without any protection, (2) with an aluminum foil attached on a wall, and (3) with an aluminum shield installed between heater and wall. The former two cases are found to be dangerous during defrosting process, because the temperatures of inner wall reach above 80'C , which is the upper temperature limit of the wall material. The case with an aluminum shield is considered to be safe by maintaining the temperature of the wall in the range of 6$0^{\circ}C$ during defrosting process.

상변화물질을 이용한 열방어체계의 수치해석 연구 (A numerical analysis of the PCM applied Thermal Protection System)

  • 오창묵;유영준;이형주;민성기
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.622-627
    • /
    • 2010
  • 본 논문은 내외부에 열원이 있는 시스템에 상변화물질(PCM, Phase Change Material)을 적용한 경우를 수치해석으로 분석한 것으로 컨넥터가 없는 경우와 있는 경우에 대하여 분석한 것이다. 각각의 경우에 $T_{max}$ 열원만 있을 경우와 $T_{max}$$710W/m^2$ 열원이 동시에 있을 경우가 고려되었다. 연구 결과 벽면에서의 열전달, 시간에 따른 PCM 온도변화 그리고 내부온도의 변화를 정리하였으며 그 결과 시스템의 구성품과 열전달 방향 및 열원의 종류에 따라 PCM의 잠열 시간이 달라진다는 점을 알 수 있었다.

  • PDF