• Title/Summary/Keyword: protection of design

Search Result 2,360, Processing Time 0.027 seconds

Analysis of Actual Condition of Counterfeits and Anti-Counterfeiting Strategies of Korean Fashion Firms (국내 패션기업의 위조상품 관리실태 및 대응전략분석)

  • 김용주
    • Journal of the Korean Home Economics Association
    • /
    • v.42 no.1
    • /
    • pp.53-67
    • /
    • 2004
  • The purpose of this study was to analyze anti-counterfeiting strategies of fashion firms in Korea. Data was collected by in-depth interviews for 25 fashion firms and 5 buying offices who had been victims of counterfeiting. The result showed that fashion firms recognized the counterfeiting, especially deceptive counterfeiting, as a serious problem in Korea and seek for stronger protection. Fashion firms adopted diverse strategies for the protection of trademark and for the protection of design; (1) Investigation and Surveillance, (2) Warning, (3) Prosecution, (4) Lawsuit, (5) Consumer education (6) High-tech tabooing, (7) Provide incentives, (8) Penalty, (9) Do nothing. Despite the diverse efforts, they proposed the most desirable strategies to deter the counterfeiting as the changes of consumer attitude and stronger legal protection.

A Study on Effects of Hydraulic Structure on River Environment(I) : Hydraulic Characteristics (수공구조물이 하천환경에 미치는 영향에 관한 연구(I) : 수리학적특성)

  • 안승섭;최윤영;이수식
    • Journal of Environmental Science International
    • /
    • v.11 no.3
    • /
    • pp.191-199
    • /
    • 2002
  • In this study, water protection reservoir is selected as the target which is located at the estuary of Taehwa river to analyze and examine the effects of hydraulic structure on river environment. This study aims at the definition of factors which cause the change of ecological environment of river due to the effects of the sediment protection reservoir, and the proposal of the direction of environmental friendly river space development through the analysis and examination of stream variation conditions and riverbed variation characteristics among many effects of hydraulic structure on river environment before and after removal of the sediment protection reservoir when design flow is yielded. Firstly, in case of removal the existing sediment protection reservoir, the hydraulic variation characteristics like depth drop due to removal of the sediment protection reservoir are thought of little because it is examined that depths drop with about 0.01m and 0.01~0.56m when low flow is yielded and design flood yielded, respectively. Nextly, as the examination result of the variation characteristics of flow velocity in case of removal the existing sediment protection reservoir, it is thought that the concern about riverbed erosion is not serious according to the analyzed result as the mean velocity of the channel section where the velocity varies in case of removal the sediment protection reservoir is about 0.07~1.36m/s when low flow is yielded, and is about 1.02~2.41m/s when design flood is yielded despite riverbed erosion is concerned as it is examined that flow velocity is getting increase as about 0.01m/s when low flow is yielded and about 0.01~0.44m/s when design flood is yielded. Lastly, from the prediction result of riverbed variation for each flow amount condition before and after removal the sediment protection reservoir, it is known that the variation range of riverbed is nearly constant when flow amount of the channel exceeds a specific limit as it is analyzed that the more flow amount, the more erosion and sediment in the channel section of down stream part of the sediment protection reservoir and the sediment protection reservoir~Samho-gyo, and the variation ranges according to flow amount between flood condition and design flood condition have little difference in the channel section of the upstream of Samho-gyo.

Power system protection IED design using an embedded processor (임베디드 프로세서를 이용한 계통 보호 IED 설계)

  • Yoon, Ki-Don;Son, Young-Ik;Kim, Kab-Il
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.711-713
    • /
    • 2004
  • In the past time, the protection relay did only a protection function. Currently, its upgraded device i.e. IED(Intelligent Electric Device) has been designed to protect, control, and monitor the whole power system automatically. Also the device is desired to successfully measure important elements of the power system. This paper considers design method of a digital protection IED with a function of measuring various elements and a communication function. The protection IED is composed of the specific function modules that are signal process module, communication module, input/output module and main control module. A signal process module use a DSP processor for analysis of input signal. Main control module use a embedded processor, Xscale, that has an ARM Core. The communication protocol uses IEC61850 protocol that becomes standard in the future. The protection IED is able to process mass information with high-performance processor. As each function module is designed individually, the reliability of the device can be enhanced.

  • PDF

Research on Aircraft Lightning Protection Design and Certification of Fuel System in Composite Material (복합재항공기 연료시스템의 낙뢰보호설계 및 인증 연구)

  • Lee, Young-jae;Cho, Wonil;Jeon, Jeonghwan;Koh, Jinhwan
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.25 no.4
    • /
    • pp.130-140
    • /
    • 2017
  • Lightning protective design of an aircraft fuel system is closely related to the safety of the flight. Recently, composite material in building an aircraft becomes more important because it can reduce the weight of the aircraft. The composite materials decrease the protection against the effect of lightning. Lightning protective design of metal material aircraft has been researched for a long time and the design technique has been announced widely. However, research on the lightning protective design using composite material aircraft is very limited. In this study, lightning protective design for fuel tank structural component, access cover, fuel filler cap and drain valve in carbon fiber composite material aircraft have been presented. To show the compliance with FAA airworthiness standard regarding the presented protection designs, three steps, including lightning strike analysis, lightning environment analysis and certification test, were conducted in accordance with FAA AC 20-53.

A Study about False Alarm of Automatic Fire Detection System (자동화재 탐지설비의 비화재보 감소방안)

  • Lee, Jong-Hwa;Lee, Chun-Ha;Kim, Shi-Kuk;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • The automatic fire detection system is an important facility installed with focusing on minimizing the damage from a fire. This paper presents in the followings as the methods to reduce the false alarm of the automatic fire detection system; first, to prepare for legal standard so that revised legal standard can be applied to the fire fighting property prior to revision; second, to introduce the performance based fire detection protection design in the law based fire protection design; third, to maintain the wiring of worn-out detector; forth, to introduce an evaluation system to the education for the fire warden; fifth, to extend the standard of MTBF(meantime between failure) of the detector; sixth, to extend of installing the analog type detector; seventh, to improve the structure of reset switch.

Cost Analysis for Fire Protection on Structural Members of Residential Steel Building using Fire Engineering Design (내화설계법에 따른 철골조 아파트의 내화피복비용 연구)

  • Kwon, In-Kyu;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.81-89
    • /
    • 2010
  • In general, fire resistance is determined through the building' uses and stories. But recently a fire engineering design that is done by the calculation of design fires from the fire cell and an evaluation of stabilities for structural behavior at fire condition have applied to almost of countries as a major alternative against a prescriptive fire design. To adopt and utilize the fire engineering design into Korea, at first, we evaluated structural stability of 21st stories steel residential building at fire condition through fire engineering design and secondly the fire protection cost was analyzed with fire engineering design method and the prescriptive one, respectively. No fire protection materials for satisfaction of building law at structural members such as columns and beams were needed and about 90 % of fire protection cost was saved.

TUTUM Easy-seismic: Development of a Seismic Design Automation Software for Building Fire Protection Systems (TUTUM Easy-seismic: 소방시설 내진설계 자동화 소프트웨어 개발)

  • Oh, Chang-Soo;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.140-148
    • /
    • 2019
  • In line with the "mandatory seismic design of fire protection facilities," development of design automation software is indispensable for improving the reliability and efficiency of seismic design. The seismic design automation software developed in this study is an automated S/W for seismic design of fire-fighting facilities, and functions such as automatic arrangement of anti-shake braces according to Korea National Fire Agency's Seismic Design Standards for fire-fighting facilities, output of seismic bracing calculation bills and automatic quantities counting. In addition, the seismic design automation software not only reduces the work speed by three times compared to the manual design of the designer, but also improves the reliability of the design by reducing the human error related to the design quantity such as the brace. In addition, in the seismic design method of fire protection facilities that have been approached conservatively, it was possible to perform the optimal seismic design by using computer algorithms for at least in the use of braces.

An Introduction on Explosion Protection System (폭발 보호(진압, 배풍, 차단) 시스템에 관한 소개)

  • 김찬주
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.76-79
    • /
    • 1996
  • This paper provides an overview or an introduction covering the nature of explosions, explosion protection techniques and explosion protection systems(EPS), It is not intended to be a result for the design or research of protection including explosion suppression, venting, isolation, and an explanation to the mechanical system.

  • PDF

A Case Study of the Commom Cause Failure Analysis of Digital Reactor Protection System (디지털 원자로 보호시스템의 공통원인고장 분석에 관한 사례연구)

  • Kong, Myung-Bock;Lee, Sang-Yong
    • IE interfaces
    • /
    • v.25 no.4
    • /
    • pp.382-392
    • /
    • 2012
  • Reactor protection system to keep nuclear safety and operational economy of plants requires high reliability. Such a high reliability of the system can be achieved through the redundant design of components. However, common cause failures of components reduce the benefits of redundant design. Thus, the common cause failure analysis, to accurately calculate the reliability of the reactor protection system, is carried out using alpha-factor model. Analysis results to 24 operating months are that 1) the system reliability satisfies the reliability goal of EPRI-URD and 2) the common cause failure contributes 90% of the system unreliability. The uncertainty analysis using alpha factor parameters of 0.05 and 0.95 quantile values shows significantly large difference in the system unreliability.

Structure Design of Fall Impact Protection Pad Using 3D Printing Technology and Comparison of Characteristics According to Filament Material (3D 프린팅 기술을 활용한 낙상충격 보호패드 구조설계 및 필라멘트 소재에 따른 특성 비교)

  • Park, Jung Hyun;Jung, Hee-Kyeong;Lee, Jeong Ran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.5
    • /
    • pp.939-949
    • /
    • 2017
  • This study uses 3D printing technology to design and fabricate a fall impact protection pad with a spacer fabric structure. The design of the pads consists of hexagonal three-dimensional units connected in a honey-comb shape; in addition, the unit consists of a surface layer and a spacer layer. Protect pads were designed as either a hexagonal type or diamond type according to the surface layer structure; subsequently, a spacer filament was also designed as the most basic I-shape type. Designed pads were printed using four types of flexible filaments to select suitable material for a fall impact protection pad. Impact protection performance and bending stiffness were evaluated for the eight type of pad outputs. As a result of the impact protection performance evaluation, when the force of 6,500N was applied, the force passed through the pad was in the range of 1,370-2,132N. FlexSolid$^{(R)}$ and Skinflex$^{TM}$ showed good protection performance and cubicon flexible filament showed the lowest protection. NinjaFlex$^{(R)}$ was found to be the most flexible in the bending stiffness evaluation.