• Title/Summary/Keyword: protection cost

Search Result 705, Processing Time 0.024 seconds

A Study on Economic Methodology for Deriving Money Coefficients (금전계수 도출을 위한 경제학적 방법론 연구)

  • Min-Hee Back
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.111-118
    • /
    • 2023
  • The International Commission on Radiological Protection (ICRP) 103 recommends a cost-benefit analysis method as an auxiliary tool for scientific and rational decision-making for the principle of optimization of radiological protection. In order to conduct a cost-benefit analysis, the safety improvement of nuclear power by regulation must be measured and converted into monetary terms. The improvement of nuclear safety can be measured by reducing the radiation exposure dose of the people, and it is necessary to determine the coefficient to convert the radiation exposure dose into money. The monetary coefficient is calculated as the product of the statistical life value (VSL) and the nominal risk coefficient. In order to derive the monetary coefficient, the willingness to pay (WTP) can be estimated using the contingent valuation method (CVM), which quantifies the value of non-market goods by converting them into monetary units. WTP can be estimated based on the random utility model, which is the basic model for bivariate selection type conditional value measurement data. Statistical life value can be calculated using the estimated WTP and reduction in early mortality, and a monetary coefficient can be derived.

Perception differences between users and policy-makers on technology protection support system for small and medium-sized businesses (중소기업 기술보호지원제도에 대한 이용자와 정책담당자의 인식차이 분석)

  • Park, Sanghoon;Cho, Namwook
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.1
    • /
    • pp.37-48
    • /
    • 2017
  • As the risk of technical leakage is increasing, technology protection support systems for small and medium-sized businesses have gained attention. This paper analyzed the perception gap of the user and policy-maker regarding technology protection support systems. First, to identify key elements of technology protection support systems and construct measurement factors, interviews with experts are conducted. Then, surveys are conducted to analyze the perception differences between the users and policy-makers. Factor analysis and ANOVA have been utilized to analyze survey results. The result shows that the perception gaps exist in the following areas: management system, cost reduction, copyright protection, customer satisfaction, leakage prevention, and awareness. To enhance the effectiveness of technology protection support systems, this paper suggests technology protection support systems should be customized in terms of the company's size and type of busines.

Engineering Technology Far-end Telecontrol Cathodic Protection on the Structure of Jetty Bridge Cap Beams

  • Liu, Yi-Hsiung;Lim, Pau-Yee;Shih, Chien-Chis
    • Corrosion Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.47-52
    • /
    • 2003
  • 23 cap beams on the 1 Km length jetty bridge in Shin-da power plant (Taipower co., Taiwan) utilize far-end telecontrol cathodic protection technology which is the first case ever used in Taiwan. The system comprises cathodic protection system and te1econtrol monitoring system. The control and monitoring such as protection current adjustment, protection potential and depolarization measurement of the 23 cap beams can be adjusted through system telecontrol operations. Thereby allows monitoring and control of the 23 anode zones in a convenient and cost effective way. This system is at present still in its best running condition since Sept. 1997 when it was completed. All the 23 cap beams can achieve the 100 mV depolarization potential criteria of protection. It meet the specifications of reinforced concrete cathodic protection standard and proved to be very excellent.

Low-cost crowbar system and protection scheme in capacitor bank module (커패시터 뱅크 모듈 구성에 있어서 경제적인 크로바 시스템과 보호회로)

  • Rim, Geun-Hie;Cho, Chu-Hyun;Lee, Hong-Sik;Pavlov, E.P.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2089-2091
    • /
    • 2000
  • Pulsed power systems consist of a capacitor bank, an isolated high-voltage charging power-supply, high-current bus-work for charging and discharging and a control system. In such pulsed power systems, the operating-lifetime of the capacitors is closely dependent on the voltage reversal. Hence, most capacitor-discharging systems includes crowbar circuits. The crowbar circuit prevents the capacitor recharging with reverse voltage. Usually it consists of crowbar resistors and high pulse-current diode-stacks connected in series. The requirements for the diode-stacks are fast-recovery time and high-voltage and large-current ratings, which results in the high cost of the pulsed-power system. This paper presents a protection scheme of a charging and discharging system of a 500kJ capacitor bank using a low-cost crowbar circuit and safety-fuses.

  • PDF

The Study on the Combat Placement Availability of the Reinforce Concrete Box-type Artillery Positions (철근콘크리트조 박스형 포상의 전력화 가능성에 관한 연구)

  • Baek, Jonghyuk;Kim, Sukbong;Park, Young Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.88-89
    • /
    • 2013
  • For the purpose of launching strikes, initial survivability of self-propelled artilleries is of crucial importance despite the fact that they are mobility weapon systems. This study identifies the combat placement possibility of the reinforced concrete box-type artillery positions, which might enable the replacement of the current igloo-types, in terms of cost and protection capability. In the numerical analysis the obtained numerical values have proved that these facilities have sufficient protection capability. In addition, it could be concluded that these facilities are also cost-competitive, if more than five positions are constructed simultaneously.

  • PDF

Analysis of Stability of PV System using the Eigenvalue according to the Frequency Variation and Requirements of Frequency Protection

  • Seo, Hun-Chul;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.480-485
    • /
    • 2012
  • Use of photovoltaic (PV) power generation system will become more widespread in the future due to anticipated cost reduction in PV technology. As the capacity of PV systems increases, a variation of power system frequency may prevent the stable output of PV system. However, the standard for the frequency protection of distributed generation in Korea Electric Power Corporation (KEPCO)'s rule does not include the setting of frequency protection. Therefore, this paper analyzes the correlation between the frequency protection requirements and the stability of grid-connected PV system for the adjustable operating setting of frequency protection. The distribution system interconnected with 3 MW PV system is modeled by Matlab/Simulink. The various values of frequency are simulated. For studied cases, the stability of PV system is analyzed. It is concluded that the setting of frequency protection is necessary to consider the stability of PV system.

A Development of the Optimized Shielding Room Design Simulator for HEMP Protection (HEMP 방호용 차폐실 최적설계를 위한 시뮬레이터 개발)

  • Min, Gyung-Chan;Kim, Dong-Il
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.121-126
    • /
    • 2010
  • Regarding HEMP has been studied as few thousand of paper by major nuclear bomb holding countries with USA for the self protection against nuclear bomb attract. Major HEMP protection facilities are consist of the shielding, filtering, grounding and high voltage protection circuits. Shielding room construction required a highest cost among the key protective facilities. Most of a theoretical formulas listed on the paper and related books has a little correlations in the certain frequency band between the theoretical formulas and field measuring results. For the reasons we proposed the advanced new theoretical formulas and developed the computer simulation S/W as enough as apply to the cost effective shielding room design for HEMP considering the various structural constants.

Assessment of Performance and Cost-Effectiveness for the Rockfall Protection Fence Using a High Carbon Steel Wire Rod (고장력 경강선을 적용한 낙석방지울타리의 성능 및 경제성 평가)

  • Lee, Yong-Joo;Na, Seung-Min;Hwang, Young-Cheol;You, Byung-Ok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.910-920
    • /
    • 2008
  • In Korea, more than 70% of the territory consists of mountains. Therefore, the construction of roads and railways has generally involved with a steep rock slope in which the event of rockfalls are often occurred due to the weathered rock conditions and rainfalls etc. This is dangerous when the rock falls into the road and railway on which vehicles and trains are running. In order to prevent such rockfalls, the rockfall protection fence consisting of post, wire rope, and PVC coating steel net has most used at the bottom of rock slopes. In a general practice, an absorbing rockfall energy, 50kJ is specified by the Ministry of Construction and Transportation. However, questions still remain about whether the rockfall protection fence works effectively or not. In this study, a typical wire rope used in the standard rockfall protection fence was replaced by the high carbon steel wire rod and to validate its capacity of rockfall energy absorbing the field rockfall tests were conducted. The testing results show that a new rockfall protection fence using the high carbon steel wire rods can absorb the rockfall energy more than 50kJ and 20% of construction cost was saved in comparison with the previous rockfall protection fence.

  • PDF

The Development Direction of Vulnerable People's Welfare-related Legislation (서민취약계층복지 관련 법제의 발전방향)

  • Yoon, Seok-Jin
    • Journal of Legislation Research
    • /
    • no.41
    • /
    • pp.171-200
    • /
    • 2011
  • Protection of vulnerable people in our country today, "the National Basic Livelihood Security Act," is primarily responsible. But current law income and wealth, and by a person responsible for supporting consider only the absolute protection of the poor, and because it is insufficient for the protection of vulnerable people. Specifically, current law does not mean the relative poverty of vulnerable people is limited to the protection of economic demand. It also incorporates the payment of salaries paid individual because the people most vulnerable to social protection is insufficient demand. Dependent regulation is too strict and a person responsible for supporting do not receive legal protection by forming a dead zone is a major cause. In this study, the development direction for the protection of vulnerable people suggests. The first, "National Basic Livelihood Security Act" award in determining the minimum cost of living is relatively proposed to introduce the concept of poverty. Second, payment of the consolidation benefit and the individual benefit to adopt a intermix approach, the social needs of vulnerable people to adapt to that proposed. Third, a person responsible for supporting dependent criteria and whether according to the actual supporting to be judged.

Development of Wave Breaking Construction Method for Shore Protection using New Type of Precast Preforated Concrete Block (프리캐스트 유공식 호안블록을 이용한 소파감쇄 신공법개발)

  • 이주호;박광순;박경래;염종윤;배한욱
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.743-748
    • /
    • 1997
  • In this paper, a new type of precast perforated concrete block is presented to be used in the construction of a step seawall. The overtopping rate of the perforated step seawall is lower than that of the traditional non-perforated step seawall. In construction stage, the cost of total construction of the perforated block is cheaper than that of traditional block. The new type of perforated block may be used as an alternative for shore protection facility.

  • PDF