• 제목/요약/키워드: protection building

검색결과 793건 처리시간 0.026초

초고층 건축물의 화재안전성능 표준화 구축 (Establishment of Performance Based Design Standardization of Fire Protection Systems for High-Rise Buildings)

  • 손봉세
    • 한국재난정보학회 논문집
    • /
    • 제5권1호
    • /
    • pp.66-74
    • /
    • 2009
  • As building heights increase, so do these challenges in Korea. High-rise buildings present a variety of challenges to fire safety and protection. The fire protection technology in our country is still on a weak situation which is mainly due to the lack of concerns by the government, companies and citizen. This paper provides general guidance regarding fire-related property protection system for high-rise building performance based design. The importance of high-rise building in of the number of occupants, the value of property, and the a catastrophic loss would have on the community all warrant an increased level of protection and life safety. Because, We have to prepare a new spacial code and standard guidance for fire protection at the stage of the high-rise building design.

  • PDF

APPLICATION OF PERFORMANCED BASED DESIGN IN FIRE PROTECTION ENGINEERING

  • Cha, David S.
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.423-438
    • /
    • 1997
  • Today's building and fire prevention codes are mostly prescriptive. Prescriptive codes are based on major fires in earlier years that created a need for specific building provision. These codes provide a minimum level of safety. As the general and engineering uses of computers have increased over the years, so has use of computers in the fire protection engineering. This has allowed fire protection engineers to develop alternative approaches to solve today's fire protection problems or to evaluate the performance of a specific fire safety goal. A performance based approach to building and fire codes involves the following: 1) identifying specific goals, such as, safely getting out of the building in 10 minutes, 2) obtain conceptual approval from authorities, 3) define performance level, 4) develop design solutions and identify tools such as, fire tests, models, or methods, to demonstrate that a design will meet the fire protection objective 5) test solutions, 6) present test method and results to the authorities. Some people in the fire protection community consider this to be nothing more than an intellectual exercise, while the others view it as a way to reduce expenses on large project$^4$ Others in fire protection community view this as a way to refine the design process to design fire protection systems to better protect the fire hazards. This paper will focus on application of these tools, specifically computer fire models, to actual cases such as: design of a smoke control system heat transfer analysis and egress of building occupants during potential fires.

  • PDF

건물 간 이격거리 협소에 따른 개구부 방화설비의 개선방안 (Improvement of fire protection equipment the opening of according to narrow the distance between buildings)

  • 오택흠;박찬석
    • 대한안전경영과학회지
    • /
    • 제15권1호
    • /
    • pp.61-68
    • /
    • 2013
  • In the case of the fire to the exterior of the building through openings, the openings of the adjacent building are exposed to the risk of combustion expanding and factors that affect the combustion in the radiant heat and direct flame. Recent five years, fire of the adjacent building indicated that incidence of the 5,134(2.27%) among total 225,934 cases occurred The damage scale of fire expanded was lower than in a single building but casualties(5.46%) and property(25.0%) damage were higher. Therefore, this study provides to analyze the operating status for fire protection equipment of fire-preventing area in the Seoul and to apply measures to improve fire protection equipment according to narrow the distance between the building openings studied.

법규적 측면에서 고찰한 고층 건축물 공사현장 화재안전 확보방안 (A Study on the Improvement of Fire Safety in high-rise Building Construction in Legal aspects)

  • 박찬석;정일균
    • 대한안전경영과학회지
    • /
    • 제17권1호
    • /
    • pp.21-32
    • /
    • 2015
  • High rising of the buildings offers a number of risk factors than ever before with regard to fire prevention. Especially in the construction site of high-rise buildings, people waste golden-time during the evacuation because temporary fire fighting facilities are not installed and transferred to a large fire because of fire suppression failure. In this study, the researcher derives the problems of fire protection in high-rise buildings construction sites and proposed the measures in such the legal aspects as fire building construction code and etc. There are the legal improvements such as orders of construction suspension in the problems of fire safety, appointing fire safety manager, temporary fire protection installation standards, enhancing penalty provisions regarding the use of fire, operating self fire brigade, confirming on-site after completing fire-protection facalities, establishment or strengthening special fire-protection investigations.

유비쿼터스 건물 화재안전시스템을 위한 성능지수 개발 - 스프링클러 시스템을 중심으로 - (Development of Performance Index for Ubiquitous Building Fire Safety System - Focused on Sprinkler System -)

  • 김종훈;노삼규
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.23-30
    • /
    • 2009
  • 건물의 소방설비시스템의 유지 관리 상태에 이상이 나타났다고 한다면, 특정 기능의 이상이 미치는 부분적 또는 전체적인 화재안전대응수준에 영향을 미친다. 따라서 효율적 소방성능을 유지하기 위해 설비기능의 가동상태를 나타 낼 수 있는 성능지수의 계산 체계가 필요하다. 이러한 성능지수의 체계는 정보수신자가 부분 이상으로 발생한 영향이 전체 기능의 상태에 얼마나 영향을 주는 것인지를 쉽게 인지할 수 있도록 하는 데에 기여할 수 있다. 따라서 건물의 화재안전수준을 나타내는 효율지표로 사용될 수 있을 뿐만 아니라, 광대역규모의 소방 관리에서도 활용성 높은 지수로 사용될 수 있다. 본 지수 산정체계는 U-건물 소방방화시설관리 운용시스템의 성능 효율지수 산정을 위한 시스템으로 개발되었다.

A Study on Fire Spread between Office Room and Atrium in the Atrium Building

  • Lee, Su-Kyung;Kim, Jong-Hoon;Ko, Han-Mog
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.345-352
    • /
    • 1997
  • We could analyse the fire behavior using the developed software for fire safety assessment in a large space such as atrium. But Korean building law hasn't admitted the result of fire risk assessment in atrium. In the legislation fire resistant wall or shutter must be required between atrium and office rooms, That has obstructed development of building design and fire protection technique in Korea. From this point of view, we made scenarios of fire spread between atrium and office rooms, and then computed fire spread and fire phenomena using FASTLite and Breakl. In this study, we can decide that fire compartmentalization between atrium and office rooms doesn't require in Atrium building if the material and fire protection system were reliable. Consequently, Korean Fire Protection Regulations have to consider in direction of increasing freedom of building.

  • PDF