• Title/Summary/Keyword: prosthesis and implants

Search Result 391, Processing Time 0.021 seconds

Analysis of longevity and success rate of fixed, removable, and implant prostheses treated in Korea (국내에서 치료된 고정성, 가철성, 그리고 임플란트 보철물의 수명 및 성공률 분석)

  • Yoon, Joon-Ho;Park, Young-Bum;Oh, Nam-Sik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.95-104
    • /
    • 2018
  • Purpose: The purpose of this study is to analyze the factors affecting the longevity of failed prosthesis and the success rate of the prosthesis based on the data evaluated with the newly developed Korean Academy of Prosthodontics (KAP) criteria. Materials and methods: Evaluation was performed in the restored prosthesis for patients who visited the prosthodontics department of the 13 dental university hospitals and general hospitals. The status of the prosthesis was classified into four categories: Good, Fair, Bad, Worst. The success was recorded if only the category was classified in 'good'. The mean duration of failed prostheses and the success rate through Kaplan-Meier method were analyzed. Results: A total of 1,804 cases of prosthesis were evaluated: 810 cases of fixed dental prostheses (FDP), 519 cases of Removable Dental Prostheses (RDP), and 475 cases of implant prosthesis. The mean duration of failed FDP was $11.41{\pm}0.30years$ and the median was 10 years. The mean duration of failed RDP was $8.18{\pm}0.29years$ and the median was 7 years. The mean duration of failed implant prosthesis was $7.99{\pm}0.30years$ and the median was 7 years. The factors related to the failure were as follows: number of units, abutments, abutments treated with root canal, and plaque index in FDPs; treated and opposing dentition in RDPs; the number of implants, duration of use, and plaque index in implant prostheses. Conclusion: The average duration of failed prosthesis was 11.41 years for FDPs, 8.18 years for RDPs, and 7.99 years for implant prosthesis, according to the evaluation with newly developed KAP criteria.

Clinical cases of implant-supported fixed dental prosthesis using modified lingual screw system (T-screw system) (개선된 설측 고정 나사 시스템(T-screw system)을 이용한 임플란트 보철 수복 증례)

  • Hong, Tae-Young;Kim, Man-Yong;Yoon, Joon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.423-430
    • /
    • 2016
  • The implant prosthesis can be divided into the screw retained prosthesis and cement retained prosthesis. Each type has advantages as well as disadvantages which is unfavorable to maintain the implants. To overcome these drawbacks, T-screw system was developed. T-screw system which utilizes a lingual direction of the screw to retain the implant prosthesis, has advantages of retrievability of the prosthesis, passive fit, and possibility to form esthetic and functional occlusal surface. The prior prosthesis which utilized horizontal screws had difficulty in fabrication especially in the case of multiple units, and also limited use with all-ceramic prosthesis. In this case, fabricating the implant prosthesis by using the T-screw system showed superior results in easy maintenance, esthetics, and also functions. In addition, we are to report the method of using the T-screw system in implant prosthesis, such as multiple units of implant prosthesis and all ceramic prosthesis.

A PHOTOELASTIC STRESS ANALYSIS OF FIXED PARTIAL DENTURES WITH ENDOPOREIMPLANTS ACCORDING TO SPLINTING, CONTACT TIGHTNESS, AND CROWN LENGTH (연결고정, 인접면 접촉강도 및 치관길이에 따른 엔도포어 임플란트를 이용한 고정성 국소의치의 광탄성 응력 분석)

  • Jeong, Hoe-Yeol;Choi, Min-Ho;Kim, Yu-Lee;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.4
    • /
    • pp.425-442
    • /
    • 2004
  • Statement of problem: A difficulty in achieving a passive-fitting prosthesis can be overcome by individual crown restoation of multiple implants. But individualized crown has another difficulty in control of contact tightness and stress distribution. Purpose: This in vitro study is to evaluate the stress distribution and the magnitude in the supporting tissues around Endopore implants with different crown lengths, interproximal contact tightness, and the splinting effects. Material & methods: Three Endopore implants($4.1{\times}9mm$) were placed in the mandibular posterior edentulous area distal to the canine and photoelastic model was made with PL-2 resin(Measurements Group, Raleigh, USA). Restorations were fabricated in two crown lengths: 9, 13 mm. For non-splinted restorations, individual crowns were fabricated on three custom-milled titanium abutments. After the units were cemented, 4 levels of interproximal contact tightness were evaluated: open, ideal($8{\mu}m$ shim stock drags without tearing), medium($40{\mu}m$), and heavy($80{\mu}m$). For splinted restorations, 3-unit fixed partial dentures were fabricated. This study was examined under simulated non-loaded and loaded conditions(6.8 kg). Photoelastic stress analysis was carried out to measure the fringe order around the implant supporting structure. Results: 1. When restorations were not splinted, the more interproximal contact tightness was increased among the three implants, the more stress was shown in the cervical region of each implant. When crown length was increased, stresses tended to increase in the apex of implants but there were little differences in stress fringes. 2. When nonsplinted restorations were loaded on the first or third implant, stresses were increased in the apex and cervical region of loaded implant. Regardless of interproximal contact tightness level, stresses were not distributed among the three implants. But with tighter interproximal contact, stresses were increased in the cervical region of loaded first or third implant. 3. When the nonsplinted restorations were not loaded, there were little stresses on the supporting structure of implants, but low level stresses were shown in the splinted restorations even after sectioning and soldering. 4. With splinted restorations, there were little differences in stresses between different crown lengths. When splinted restorations were loaded, stresses were increased slightly on the loaded implant, but relatively even stress distribution occurred among the three implants. Conclusions: Splinting the crowns of adjacent implants is recommended for Endopore implants under the overloading situation.

Clinical outcome of immediately and early loaded implants with laser treated surface: a 3-year retrospective study

  • Leesungbok, Richard;Seo, Jin-Ho;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.163-166
    • /
    • 2018
  • PURPOSE. The marginal bone loss of implants with laser treated surface was investigated after six weeks of loading after implant installation to the mandible molar area. MATERIALS AND METHODS. A total of 23 implants were placed in the edentulous molar area of the mandible: 13 implants were immediately loaded and 10 implants were early loaded. The implants used were made of titanium grade 23, screw shaped, 4.2 mm in diameter, and 10 mm in length. Patients were evaluated with resonance frequency analysis at implant fixture installation and 1, 2 (final prosthesis installation), 3, 5, 8, and 14 months later. X-rays were taken at 2 months after fixture installation and 1, 2, 3 years after to measure the marginal bone loss. RESULTS. The mean ISQ value measured at the implant installation was over 70 at all-time points. The average of marginal bone loss was average 0.33 mm. CONCLUSION. Immediate implant loading for laser treated implants would be possible.

Implant Adapted Occlusion (임플란트 적응 교합 : 생역학 원리에 의한 임상지침)

  • Kim, Yongsik;Kim, Hyung-Jin;Lee, Byung-Uk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.1
    • /
    • pp.57-70
    • /
    • 2004
  • The significance of occlusion has regained its popularity in dentistry with the introduction of implant therapy. Literature has reported that the clinical success and longevity of dental implants can be achieved by biomechanically controlled occlusion. Occlusal overload is known to be one of the main causes for implant failure. Evidences have suggested that occlusal overload contribute to early implant bone loss as well as deosseointegration of successfully integrated implants. Unlike natural teeth, osseointegrated implants are ankylosed to surrounding bone without the periodontal ligament (PDL) which provides mechanoreceptors as well as shock-absorbing function. Moreover, the crestal bone around dental implants may act as a fulcrum point for lever action when a force (bending moment) is applied, indicating that implants/implant prosthesis could be more susceptible to crestal bone loss by applying force. Hence, it is essential for clinicians to understand inherent differences between teeth and implants and how force, either normal or excessive force, may influence on implants under occlusal loading. The purposes of this paper are to review the importance of implant occlusion, to establish the optimum implant occlusion with biomechanical rationale, to provide clinical guidelines of implant occlusion and to discuss how to manage complications related to implant occlusion.

MAXILLARY SINUS ELEVATION PROCEDURES: A Report of Six Cases (상악동거상술 및 임플란트매식에 의한 상악 구치부 수복에 관한 임상적 연구)

  • Lee, Dong-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.300-316
    • /
    • 1995
  • Methods for restoring the posterior portion of the maxilla with delayed and simultaneous sinus lift, composite graft and placement of TPS cylinder and screw type implants are presented. Sinus grafting is needed because of minimal remaining alveolar bone and supporting posterior maxillary portion, The composite graft material uses a combination of autogeneous bone from tuberosity, dimeneralized freeze dried allogenic bone and hydroxylapatite with saline. Since 1991, feb, 1 sinus graft with delayed implantation of 3 cylinder implants and 5 sinus grafts with simultaneous placement of 4HA coated screw typed, 8 TPS cylinder typed implants have been performed for 6 patients. None of the 15 restored implants have been lost, Temporization of prosthesis was done about 2-5 months before final prosthetic work, None of them shows any severe complication.

  • PDF

Clinical evaluation of retained preload and cement washout in screw- and cement-retained implant prosthesis (나사 시멘트 유지형 임플란트 보철물의 잔여 전부하 및 시멘트 파손에 대한 임상평가)

  • Chung, Chae-Heon;Son, Mee-Kyoung;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.301-309
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the clinical performance of screw- and cement-retained implant prosthesis (SCP) design in terms of retained preload of abutment screws and cement washout. Materials and methods: Patients with the partial posterior edentulous areas comprised the study group. Implants were placed, and SCPs were delivered after 3 to 6 months healing. Follow-up examinations were performed. The implant survival rate and the prosthetic success rate were evaluated. The retained preload ratio of abutment screws and the prosthetic decementation ratio were measured. Results: Twenty one SCPs (forty three implants)in twenty patients were followed up to 64 months. All of the implants survived during the follow-up period (mean follow-up: 34 months). The prosthetic success rate was 100 % considering no abutment, screw, porcelain or metal frame fractures, as well as no screw loosening. The retained preload ratio of SCPs at the end of follow-up period was 97.61% (${\pm}16.29$) and the decementation ratio was 9.5 %. Conclusion: Within the limitations of this clinical study, SCP design showed favorable short-term clinical performances in respect of screw loosening and cement washout.

Clinical Application of Radial Head Prosthesis (요골두 치환술의 임상적 적용)

  • Moon, Jun-Gyu
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.140-145
    • /
    • 2011
  • Purpose: Installing a radial head prosthesis has developed into a reliable procedure to replace the native radial head for treating unreconstructible radial head fracture when this is associated with an unstable elbow or forearm. A variety of implants have been developed and these are now commercially available. This article reviews the literature related to the indications, the available implants and the surgical techniques of radial head replacement arthroplasty. Materials and Methods: The main indication for a metallic radial head prosthesis is a comminuted fracture that is not amenable to reconstruction, and particularly if it is associated with complex elbow injuries. Excision of the radial head should be avoided in the presence of combined injured ligaments or interosseous membrane injury. Three different implants are available in Korea, including the bipolar, press fit monopolar and loose fit monopolar radial head prostheses. A primary technical goal of radial head arthroplasty is the insertion of an implant that closely replicates the native radial head. The major pitfall when using a metallic radial head prosthesis is the insertion of a longer implant, which results in overstuffing of the radiocapitellar joint. Results and Conclusion: Satisfactory clinical results can be anticipated when a radial head prosthesis is used for the correct indications and when a systemic approach is undertaken to ensure proper sizing. For the future studies, we need data regarding the long term outcomes and comparison of the various types of prostheses.

Evaluation of dental status using a questionnaire before administration of general anesthesia for the prevention of dental injuries

  • Kyungjin Lee;Seo-Yul Kim;Kyeong-Mee Park;Sujin Yang;Kee-Deog Kim;Wonse Park
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.1
    • /
    • pp.9-17
    • /
    • 2023
  • Background: Dental evaluation and protection are important for preventing traumatic dental injuries when patients are under general anesthesia. The objective of the present study was to develop a questionnaire based on dentition-related risk factors that could serve as a valuable tool for dental evaluation and documentation. Methods: We developed a questionnaire for dental evaluation before administration of general anesthesia, investigated the association between patient-and-dentist responses and mouthguard fabrication, and assessed response agreement between 100 patients. Results: Protective mouthguards were fabricated for 27 patients who were identified as having a high risk of dental injury. There was a strong association between dentists' responses and mouthguard fabrication, depending on the general oral health status, use of ceramic prosthesis, presence of masticatory pain related to periodontal diseases, gingival edema, and implants (P < 0.05). Response agreement between patients and dentists for items related to dental pain, loss of dental pulp vitality, root canal therapy, dental trauma, aesthetic prosthesis, tooth mobility, and implant prosthesis was high (Cohen's kappa coefficient κ ≥ 0.6). Conclusions: A high agreement was observed between patient-dentist responses and a strong association with mouthguard fabrication for items pertaining to ceramic prosthesis, masticatory pain, and dental implants. Patients with a "yes" response to these items are recommended to undergo a dental evaluation and use a dental protective device while under general anesthesia.

A resonance frequency analysis of sandblasted and acid-etched implants with different diameters: a prospective clinical study during the initial healing period

  • Kim, Hyun-Joo;Kim, Yeun-Kang;Joo, Ji-Young;Lee, Ju-Youn
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.2
    • /
    • pp.106-115
    • /
    • 2017
  • Purpose: The possibility of immediate or early loading has become popular in implant dentistry. A prerequisite for the immediate or early loading of an implant prosthesis is the achievement of initial stability in the implant. Moreover, in response to clinicians' interest in verifying clinical stability to determine the optimal time point for functional loading, a non-invasive method to assess implant stability has been developed on the basis of resonance frequency analysis (RFA). The primary objective of this study was to monitor the stability of sandblasted, large-grit, and acid-etched (SLA) implants with different diameters during the early phases of healing by RFA. The secondary objective was to evaluate how the initial stability of implants varied depending on different surface modifications and other contributing factors. Methods: Thirty-five implants (25 SLA implants and 10 resorbable blasting media [RBM] implants) placed in 20 subjects were included. To measure implant stability, RFA was performed at baseline and at 1, 2, 3, 4, 6, and 10 weeks after surgery. Results: The longitudinal changes in the implant stability quotient (ISQ) values were similar for the SLA implants with different diameters and for the RBM implants. During the initial healing period, the ISQ decreased after installation and reached its lowest values at 1 week and 2 weeks, respectively. The mean ISQ values in the SLA implants were significantly higher in ${\varnothing}5.0mm$ implants than in ${\varnothing}4.0mm$ implants. Men showed a higher ISQ than women. Mandibular sites showed a higher ISQ than maxillary sites. Conclusions: All implants used in this study are suitable for immediate or early loading under appropriate indications. A wider diameter and SLA surface treatment of implants could improve the stability, if the implant is fixed with at least 30 Ncm of insertion torque.