• Title/Summary/Keyword: prosthesis and implants

Search Result 389, Processing Time 0.045 seconds

Magnet retained intraoral-extra oral combination prosthesis: a case report

  • Banerjee, Saurav;Kumar, Surender;Bera, Amit;Gupta, Tapas;Banerjee, Ardhendu
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.235-238
    • /
    • 2012
  • Facial prosthesis is generally considered over surgical reconstruction to restore function and appearance in patients with facial defects that resulted from cancer resection. Retention of the prosthesis is challenging due to its size and weight. Retention can be achieved by using medical grade adhesives, resilient attachments, clips and osseointegrated implants. It can also be connected to obturator by magnets. This clinical report highlights the rehabilitation of a lateral midfacial defect with a two piece prosthesis that included an extra oral facial prosthesis and an intraoral obturator with the use of magnets.

A Digitally Designed All-on-4 Restoration with Screwmentable Concept

  • Park, Koungjin;Han, Jung-Suk;Lee, Jae-Hyun
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.84-91
    • /
    • 2022
  • An all-on-4 restoration allows edentulous patients to use a fixed prosthesis with a minimum number of implants. These implant-supported fixed complete dentures have traditionally been fabricated as screw-retained or cement-retained prostheses. However, it is difficult to passively fit the long-span full-arch prosthesis using the screw-retained type restoration, and predictable retrievability is not obtained with the cement-retained type. This case report describes a prosthesis fabricated using a combination of the two retention types. The screwmentable method allows the implant-supported fixed complete denture to achieve a passive fit at the connection with retrievability. In addition, a framework with an optimized size was designed by using digital dental technology.

Splinted and non-splinted implant-supported restorations : prosthetic considerations for restoring multiple adjacent teeth (Splinted or Non-splinted: 다수의 인접한 치아 결손부 수복을 위한 임플란트 보철)

  • Yoon, Hyung-In
    • The Journal of the Korean dental association
    • /
    • v.54 no.3
    • /
    • pp.198-205
    • /
    • 2016
  • The purpose of this paper was to investigate the significance of splinted and non-splinted implant-supported restorations with an internal connection for multiple consecutively missing teeth. Upon examination of the effects of fixture-abutment connection, the distribution of occlusal load was favorable in splinted implant-prosthesis with an external connection, but effect of strain distribution was not significant in splinted implant-prosthesis with an internal connection. In splinted implant-prostheses for short implants, strain distribution was not affected by the method of retention. For cement-retained prostheses, the effect of strain distribution due to splinting was not significant. In clinical studies, non-splinted prostheses with an internal connection for multiple consecutively missing teeth showed high survival rate, mild marginal bone loss, and stable periodontal condition. However, failure to achieve optimal proximal contact between single-unit prostheses may lead to food impaction, and veneer fracture may be inevitable when the framework provides inadequate support in the proximal region. In conclusion, splinted implant-prosthesis is not an indication in all cases, and clinical consideration of its use should be based on the patient's oral condition, such as location and number of implants, formation of proximal contact, canine guidance, existence of parafunctional habit, and oral hygiene, when multiple consecutively missing teeth are replaced by internal connection type implant.

  • PDF

External vs internal connection implant system (External vs internal implant : 각각의 장점과 고려사항)

  • Seong, Dong-Jae;Hong, Seoung-Jin;Ha, Seung-Ryong
    • The Journal of the Korean dental association
    • /
    • v.54 no.3
    • /
    • pp.184-190
    • /
    • 2016
  • The osseointegration of titanium implants has been examined over the past 50 years. Many implant systems have been introduced and have become popular to the implant dentistry. The designs of the connection between implant fixture and abutment are divided into external vs internal connection. From beginning, the $Br{\aa}nemark$ system was characterized by an external hexagon. Internal connection has been developed to reduce stress transferred to the bone. These differences may have impact on the clinical procedures and protocols, laboratory and components costs, and incidence of complications. Therefore, the clinician has to know the different biomechanical features and understand their implications to produce successful implant-supported prosthesis with an external or an internal connection system.

  • PDF

Full mouth rehabilitation of mandibular edentulous patient using implant hybrid prosthesis (하악 무치악 환자에서 임플란트 하이브리드형 보철물을 이용한 전악 수복 증례)

  • Kim, Hyun-Suk;Kim, So-Hyun;Oh, Namsik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.25-30
    • /
    • 2018
  • In edentulous patients, the advantages of prosthodontic therapy using oral implants include both stability and comfort. Advantages suggested for this approach include the prevention of mandibular bone resorption and increased masticatory function. Implant hybrid prostheses place 4 to 6 implants between the mental foramens, and cantilevers are used to replace the posterior teeth at both ends. The 85 - year - old female patient visited our clinic with complete edentulism in the maxilla and mandible. This article reports a satisfactory clinical and esthetic outcome of full mouth rehabilitation using removable complete denture in the maxilla and implant hybrid prosthesis in the mandible.

Effect of repetitive firing on passive fit of metal substructure produced by the laser sintering in implant-supported fixed prosthesis

  • Altintas, Musa Aykut;Akin, Hakan
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.167-172
    • /
    • 2020
  • PURPOSE. The aim of the present study was to investigate the passive fit of metal substructure after repetitive firing processes in implant-supposed prosthesis. MATERIALS AND METHODS. Five implants (4 mm diameter and 10 mm length) were placed into the resin-based mandibular model and 1-piece of screw-retained metal substructure was produced with the direct metal laser sintering (DMSL) method using Co-Cr compound (n = 10). The distance between the marked points on the multiunit supports and the marginal end of the substructure was measured using a scanning electron microscope (SEM) at each stage (metal, opaque, dentin, and glaze). 15 measurements were taken from each prosthesis, and 150 measurements from 10 samples were obtained. In total, 600 measurements were carried out at 4 stages. One-way ANOVA test was used for statistical evaluation of the data. RESULTS. When the obtained marginal range values were examined, differences between groups were found to be statistically significant (P<.001). The lowest values were found in the metal stage (172.4 ± 76.5 ㎛) and the highest values (238.03 ± 118.92 ㎛) were determined after glaze application. When the interval values for groups are compared with pairs, the differences between metal with dentin, metal with glaze, opaque with dentin, opaque with glaze, and dentin with glaze were found to be significant (P<.05), whereas the difference between opaque with metal was found to be insignificant (P=.992). CONCLUSION. Passive fit of 1-piece designed implant-retained fixed prosthesis that is supported by multiple implants is negatively affected by repetitive firing processes.

Study on Comparison of Dental Prosthesis Condition according by Educational Level (교육수준에 따른 구강 보철물 상태 비교 연구)

  • Kim, Hye Youn;Lee, Mi Hee;Kim, Ji Hye
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.123-129
    • /
    • 2017
  • This study investigated the dental prosthesis condition from the sixth primitive data of Korea National Health and Nutrition Examination Survey to analyze and compare the necessity of existent dental prosthesis condition, dental bridge and dentures in order to determine the real oral health condition by educational level targeting adults aged over 20 years old. From the results, based on demographic-sociologic features, 32.2% of females were under elementary school graduation level, which was lower than males, and the educational level decreased with increasing age, and these trends were statistically significant. As for income level, 45.3% of university graduates had the highest income level and 77.4% of this age group were professionals, which was the highest percentage and was statistically significant. In terms of dental prosthesis condition according to educational level, the under elementary school graduation group had the most dental prosthesis and the greatest need for partial dentures and full dentures. As for the necessary number of fixed implants, the upper jaw had the most number of fixed implants and in the lower jaw, the under middle school graduation needed the most fixed implants.

The Clinical Implications of Poly Implant Proth$\grave{e}$se Breast Implants: An Overview

  • Wazir, Umar;Kasem, Abdul;Mokbel, Kefah
    • Archives of Plastic Surgery
    • /
    • v.42 no.1
    • /
    • pp.4-10
    • /
    • 2015
  • Mammary implants marketed by Poly Implant Proth$\grave{e}$se (PIP) were found to contain industrial grade silicone and this caused heightened anxiety and extensive publicity regarding their safety in humans. These implants were used in a large number of patients worldwide for augmentation or breast reconstruction. We reviewed articles identified by searches of Medline, PubMed, Embase, and Google Scholar databases up to May 2014 using the terms: "PIP", "Poly Implant Proth$\grave{e}$se", "breast implants" and "augmentation mammoplasty" "siloxanes" or "silicone". In addition the websites of regulating bodies in Europe, USA, and Australia were searched for reports related to PIP mammary implants. PIP mammary implants are more likely to rupture than other implants and can cause adverse effects in the short to the medium term related to the symptoms of rupture such as pain, lumps in the breast and axilla and anxiety. Based on peer-reviewed published studies we have calculated an overall rupture rate of 14.5% (383/2,635) for PIP implants. However, there is no evidence that PIP implant rupture causes long-term adverse health effects in humans so far. Silicone lymphadenopathy represents a foreign body reaction and should be treated conservatively. The long-term adverse effects usually arise from inappropriate extensive surgery, such as axillary lymph node dissection or extensive resection of breast tissue due to silicone leakage.

Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis

  • Kim, Seok-Gyu;Chung, Chae-Heon;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.207-213
    • /
    • 2015
  • PURPOSE. The purpose of this study was to examine the abutment screw stability of screw- and cement-retained implant-supported dental prosthesis (SCP) after simulated cement washout as well as the stability of SCP cements after complete loosening of abutment screws. MATERIALS AND METHODS. Thirty-six titanium CAD/CAM-made implant prostheses were fabricated on two implants placed in the resin models. Each prosthesis is a two-unit SCP: one screw-retained and the other cemented. After evaluating the passive fit of each prosthesis, all implant prostheses were randomly divided into 3 groups: screwed and cemented SCP (Control), screwed and non-cemented SCP (Group 1), unscrewed and cemented SCP (Group 2). Each prosthesis in Control and Group 1 was screwed and/or cemented, and the preloading reverse torque value (RTV) was evaluated. SCP in Group 2 was screwed and cemented, and then unscrewed (RTV=0) after the cement was set. After cyclic loading was applied, the postloading RTV was measured. RTV loss and decementation ratios were calculated for statistical analysis. RESULTS. There was no significant difference in RTV loss ratio between Control and Group 1 (P=.16). No decemented prosthesis was found among Control and Group 2. CONCLUSION. Within the limits of this in vitro study, the stabilities of SCP abutment screws and cement were not significantly changed after simulated cement washout or screw loosening.

Numerical Analysis on Posterior Prosthesis of Implant Temporary Teeth Combination Bridge (임플란트 임시치아 결합형 브리지의 구치부 보철물에 대한 수치해석)

  • Seo, Kyung-Hyo;Lee, Chi-Woo;Moon, Byung-Cheol
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.60-65
    • /
    • 2014
  • This research examined an immediate loading capable of providing a masticatory function and financial affordability while satisfying every requirement of a useful immediate loading. In this research, numerical value analysis was performed on couple-type posterior teeth implants developed by making up for the problems of extant implants. As a result of examining the effects of external impacts on extant implants and their deformation, relatively lager deformations separated from a molar were found concerning molar deformation implant with the maximum deformation level being approximately 1.657mm. In this research, the improved implant showed much improvement in terms of impact analysis in its deformation dispersion status after unloading the impulsive load from a punch. As for the case of hepf, about 1.657mm occurred but the improved model showed about 0.9217mm, exhibiting 55.6% advancement.