• 제목/요약/키워드: proportional control valve

검색결과 185건 처리시간 0.024초

유압제어시스템 적용을 위한 ER 밸브의 내구성 평가 (Durability Evaluation of ER Fluids in Hydraulic Control Systems)

  • 김도태;장성철
    • 한국공작기계학회논문집
    • /
    • 제16권2호
    • /
    • pp.100-105
    • /
    • 2007
  • Electro-rheological(ER) fluid and valve are fabricated and evaluated experimentally in its durability to utilize the hydraulic control systems for long term operation. The two-ports ER valve used in the experiment consist of twelve parallel multi-layer electrodes and provide a restriction to the passage of ER fluid because of the viscous pressure drop and a component induced by the electric field. The durability test of ER valve are performed by measuring the surface roughness of electrodes with variation of an electric field strength and test time(1000 or 1800min.). Also, the shear stress and shear rate are measured to evaluate the durability of ER fluid as function of time. After durability test, ER shear stress increases approximately proportional to the shear rate with applied electric field intensity, In the ER valve, the center line average height roughness(Ra) of copper electrode increases about 1.56 times and ten-point median height roughness(Rz) increases about 2.2 times after the durability test. An understanding of these durability is essential to predicting the service life of ER fluid and valves.

오일쿨러의 고정밀 온도 제어를 위한 PI 및 피드포워드 제어기 설계 (Design of PI and Feedforward Controller for Precise Temperature Control of Oil Cooler System)

  • 변종영;정석권
    • 동력기계공학회지
    • /
    • 제14권6호
    • /
    • pp.89-95
    • /
    • 2010
  • This paper deals with design method of proportional-integral(PI) and feedforward controller for obtaining precise temperature and high energy efficiency of oil cooler system in machine tools. The compressor's speed and opening angle of an electronic expansion valve are controlled to keep reference value of temperature at oil outlet and superheat of an evaporator. Especially, the feedforward controller is added to suppress temperature fluctuation under abrupt disturbances. Through some experiments, the suggested method can control the target temperature within steady state error of ${\pm}0.l^{\circ}C$ and maximum overshoot $0.2^{\circ}C$ under abrupt disturbances.

해석적 Bode 방법에 의한 직접구동형서보밸브의 고전적 제어기 설계 (Classical Controller Design of Direct Drive Servo Valve Using Analytical Bode Method)

  • 이성래;최현영;문의준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.507-514
    • /
    • 2001
  • Direct drive servovalve(DDV) is a kind of one-stage valve since the rotary motion of DC motor is directly transferred to the linear motion of valve spool through the link. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the classical controller is designed using the analytical Bode method.

  • PDF

컴플렉스법에 의한 직접구동형서보밸브의 진상-지상 제어기 설계 (Lead-Lag Controller Design of Direct Drive Servo Valve Using Complex Method)

  • 이성래
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1590-1595
    • /
    • 2003
  • Direct drive servovalve(DDV) is a kind of one-stage valve since the rotary motion of DC motor is directly transferred to the linear motion of valve spool through the link. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the lead-lag controller is designed using the complex method that is one kind of constrained direct search method.

  • PDF

컴플렉스법에 의한 직접구동형서보밸브의 진상-지상 제어기 설계 (Lead-Lag Controller Design of Direct Drive Servo Valve Using Complex Method)

  • 이성래
    • 대한기계학회논문집A
    • /
    • 제28권11호
    • /
    • pp.1719-1726
    • /
    • 2004
  • Direct drive servovalve(DDV) is a kind of one-stage valve because the main spool valve is directly driven by the DC motor. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the lead-lag controller is designed using the complex method that is one kind of constrained direct search method.

해석적 Bode 방법에 의한 직접구동형서보밸브의 고전적 제어기 설계 (Classical Controller Design of Direct Drive Servo Valve Using Analytical Bode Method)

  • 이성래;최현영;문의준
    • 대한기계학회논문집A
    • /
    • 제26권4호
    • /
    • pp.754-763
    • /
    • 2002
  • Direct drive servovalve(DDV) is a kind of one-stage valve since the rotary motion of DC motor is directly transferred to the linear motion of valve spool through the link. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the classical controller is designed using the analytical Bode method.

정밀 위치 제어를 위해 MR 밸브 시스템을 활용한 차량 유압 리프트에 대한 수치해석적 고찰 (A Numerical Study of New Vehicle Hydraulic Lift Activation by a Magneto-rheological Valve System for Precise Position Control)

  • 이태훈;박진하;최승복;신철수;최지영
    • 한국소음진동공학회논문집
    • /
    • 제27권1호
    • /
    • pp.28-35
    • /
    • 2017
  • 최근 기존의 유압 차량 리프트는 높이제어의 어려움으로 인해 기술개발의 한계에 직면하였다. 휠 얼라이먼트나 차량의 하중 분포에 따른 미세한 불규칙적인 변형을 보상하기 위해서는 매우 정밀한 위치 제어성이 요구되고 있다. 이 연구에서는 이러한 기존 리프트 시스템의 한계를 해결하고자 매우 정교한 압력강하를 이끌어낼 수 있는 MR 밸브 시스템을 활용하여 새로운 차량 리프트를 제안하고 이에 대한 분석을 진행한다. 우선적으로 MR 밸브의 요구되는 성능을 파악하기 위해 유압 리프트의 운동방정식을 설립하고, 요구되는 압력강하를 얻기 위해 MR 밸브를 설계한다. 또한 정밀한 위치 제어 성능을 얻기 위해 PID 제어기를 설립하고, 시뮬레이션을 통해 제안된 시스템의 제어성을 검증한다.

유압 굴삭기용 폐루프 타입 MCV(Main Control Valve) (Closed loop type MCV(Main Control Valve) for Hydraulic Excavator)

  • 임태형;이홍선;양순용
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.864-870
    • /
    • 2005
  • Hydraulic excavators have been popular devices in construction field because of its multi-workings and economic efficiency. The mathematical models of excavators have many nonlinearities because of nonlinear opening characteristics and dead zone of main control valve, oil temperature variation, etc. The objective of this paper is to develop a simulator for hydraulic excavator using AMESim. Components and whole circuit are expressed graphically. Parameters and nonlinear characteristics are inputted in text style. From the simulation results, fixed spring stiffness of MCV can't satisfy accuracy of spool displacement under whole P-Q diagrams. Closed loop type MCV containing proportional gain is proposed in this paper that can reduce displacement error. The ability of closed loop MCV is verified through comparing with normal type MCV using AMESim simulator. The simulator can be used to forecastexcavator behavior when new components, new mechanical attachments, hydraulic circuit changes, and new control algorithm are applied. The simulator could be a kind of development platform for various new excavators.

  • PDF

산업용 밸브 액추에이터 비례제어 컨트롤러 개발 (Development of Proportional Valve Actuator Controller for Industrial Site)

  • 박한영;김진영;안성수;강준희
    • 전자공학회논문지
    • /
    • 제50권5호
    • /
    • pp.269-274
    • /
    • 2013
  • 본 연구에서는 전기식 밸브 액추에이터의 개폐 정도를 입력신호에 비례하여 제어하기 위한 PCU (Proportional Control Unit), CPT (Current Position Transmitter)와 액추에이터의 회전위치를 측정하는 Rotary Absolute Optical Encoder를 설계 및 제작 하였고, DAQ 하드웨어와 LabView를 사용한 테스트 시스템을 설계하여 성능시험을 하였다. PCU는 1-5V, 0-5V, 0-10V, 2-10V 전압 신호와 4-20mA의 전류신호를 일정한 범위의 0.5-2.5V 전압신호로 변환하도록 설계하였다. CPT는 MCU의 PWM 신호를 입력받아 밸브의 개폐 정도를 4-20mA의 전류신호로 출력 하도록 하였다. Infrared LED와 Infrared Transistor를 사용하여 20bit Optical Encoder를 개발하였으며, Main Board와 Serial 통신을 하도록 설계하였다. DAQ 하드웨어와 Labview를 통한 테스트 결과 PCU는 ${\pm}0.003V$, CPT는 ${\pm}0.01mA$의 오차범위 내에서 작동하여 산업용 밸브 액추에이터가 안정적으로 작동하는 것을 관찰하였으며, Encoder는 $11.25^{\circ}$의 분해능을 갖고, 최대 32,768 회의 모터회전수 범위까지 측정할 수 있도록 하였다.