• Title/Summary/Keyword: proportional control algorithm

Search Result 346, Processing Time 0.024 seconds

Application of a PID Feedback Control Algorithm for Adaptive Queue Management to Support TCP Congestion Control

  • Ryu, Seungwan;Rump, Christopher M.
    • Journal of Communications and Networks
    • /
    • v.6 no.2
    • /
    • pp.133-146
    • /
    • 2004
  • Recently, many active queue management (AQM) algorithms have been proposed to address the performance degradation. of end-to-end congestion control under tail-drop (TD) queue management at Internet routers. However, these AQM algorithms show performance improvement only for limited network environments, and are insensitive to dynamically changing network situations. In this paper, we propose an adaptive queue management algorithm, called PID-controller, that uses proportional-integral-derivative (PID) feedback control to remedy these weak-Dalles of existing AQM proposals. The PID-controller is able to detect and control congestion adaptively and proactively to dynamically changing network environments using incipient as well as current congestion indications. A simulation study over a wide range of IP traffic conditions shows that PID-controller outperforms other AQM algorithms such as Random Early Detection (RED) [3] and Proportional-Integral (PI) controller [9] in terms of queue length dynamics, packet loss rates, and link utilization.

A Study on the Stability Characteristics of Actively Controlled Externally Pressurized Air Journal Bearing (능동 제어되는 외부 가압 공기 베어링의 안정 특성에 관한 연구)

  • Lee, Jeong-Bae;Kim, Gyeong-Ung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.3 s.174
    • /
    • pp.543-549
    • /
    • 2000
  • Results of theoretical investigations of the stability characteristics of an actively controlled externally pressurized air journal bearing are presented. Proportional control and derivative control are used for the control algorithm of active air bearing. The stability characteristics of the actively controlled bearing operating at zero steady-state eccentricity is investigated with the step jump method. The speed at onset of instability is raised for both proportional control and derivative control of bearing. Proportional control increased the stability threshold without affecting the whirl ratio. But for derivative control of bearing, stability threshold increase is accompanied by a parallel reduction of the whirl ratio. Results show active control of bearing can be adopted for the stability improvement of air journal bearing.

Control of the pressurized water nuclear reactors power using optimized proportional-integral-derivative controller with particle swarm optimization algorithm

  • Mousakazemi, Seyed Mohammad Hossein;Ayoobian, Navid;Ansarifar, Gholam Reza
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.877-885
    • /
    • 2018
  • Various controllers such as proportional-integral-derivative (PID) controllers have been designed and optimized for load-following issues in nuclear reactors. To achieve high performance, gain tuning is of great importance in PID controllers. In this work, gains of a PID controller are optimized for power-level control of a typical pressurized water reactor using particle swarm optimization (PSO) algorithm. The point kinetic is used as a reactor power model. In PSO, the objective (cost) function defined by decision variables including overshoot, settling time, and stabilization time (stability condition) must be minimized (optimized). Stability condition is guaranteed by Lyapunov synthesis. The simulation results demonstrated good stability and high performance of the closed-loop PSO-PID controller to response power demand.

Development of a Draft Control System for Tractor Using a Proportional Valve (비례밸브를 이용한 트랙터 견인력제어시스템 개발)

  • Lee, S.S.;Lee, J.Y.;Mun, J.H.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.1 s.114
    • /
    • pp.9-15
    • /
    • 2006
  • Draft control is key technique in plow control system for automation of implement control system. To make the consistent draft force is an essential factor for preventing the reduction of working efficiency by tractor's slip and also improving the working efficiency. Therefore, the purpose of this study is to develop the draft sensor for draft control of plow and evaluate the usability of the algorithm of draft control system using proportional control valve. The developed draft control system could extract the draft force very well regardless of draft condition, change of setting draft force and response time in the response characteristic test. The maximum draft force at 3-Point linkage was 10,000 N and the deviation of the control system was 125.8 N in steady state condition. The developed control system worked very well with regard to the change of draft force in field and even in soil condition with soil reaction. The results of experiment showed the characteristics of response was sufficient to be used as the implement draft control system for tractor using proportional valve.

DC Voltage Balancing Control of Half-Bridge PWM Inverter for Liniear Compressor of Refrigerator (냉장고의 선형압축기 구동을 위한 단상 하프브리지 인버터 시스템에서 직류단 불평형 보상에 관한 연구)

  • Kim, Ho-Jin;Kim, Hyeong-Jin;Kim, Dong-Youn;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.3
    • /
    • pp.256-262
    • /
    • 2017
  • This paper presents the control algorithm of a single-phase AC/DC/AC PWM converter for the linear compressor of a refrigerator. The AC/DC/AC converter consists of a full-bridge PWM converter for the control of the input power factor and a half-bridge PWM inverter for the control of the single-phase linear compressor. At the DC-link of this topology, two capacitors are connected in series. These DC-link voltages must be balanced for safe operation. Thus, a new control method of DC voltage balancing for the half-bridge PWM inverter is proposed. The balancing algorithm uses the Integral-Proportional controller and inserts the DC-offset current at the Proportional-Resonant current controller of the inverter to solve the DC-link unbalanced voltages between the two capacitors. The proposed algorithm can be easily implemented without much computation and additional hardware circuit. The usefulness of the proposed algorithm is verified through several experiments.

The Development of EMG-based Powered Wheelchair Controller for Users with High-level Spinal Cord Injury using a Proportional Control Scheme (중증 장애인을 위한 근전도 기반 비례제어 방식의 전동 휠체어 제어기 개발)

  • Song, Jae-Hoon;Han, Jeong-Su;Oh, Young-Joon;Lee, He-Young;Bien, Zeung-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.6-8
    • /
    • 2004
  • The objective of this paper is to develop a powered wheelchair controller based on EMG for users with high-level spinal cord injury using a proportional control scheme. An advantage of EMG is relative convenience of acquisition by a surface electrode to users. Direction information can be easily extracted from two EMG channels and force information can be acquired by proportional relationship between the amplitude of EMG and user's power, respectively. Pattern classification algorithm is a threshold method with a supervised learning process. Furthermore, the emergency situation can be avoided using an interrupt function. We evaluated the performance of powered wheelchair controller by navigating a pre-defined path with three non-handicapped people. The results show the feasibility of EMG as an input interface for powered wheelchair and other devices for the seriously disabled.

  • PDF

A Study on Driving Algorithm of Single-phase PMSM based on Proportional Resonant Current Controller (비례공진 전류제어기 기반의 단상 영구자석 동기전동기 운전에 관한 연구)

  • Seong, Uiseok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.1
    • /
    • pp.115-120
    • /
    • 2021
  • In this paper, an operating algorithm for single-phase permanent magnet synchronous motor based on PR current controller is proposed. In general, an asymmetric gap may occur depending on the shape of the rotor of single-phase PMSM, and this causes noise and vibration during high-speed operation. Therefore, in this paper, an operating algorithm for a single-phase PMSM usihng a proportional resonant current conrtoller with excellent control stability was proposed. Proportional resonant current controller has on steady state error is relatevly robust against distortion. Also, steady state error of AC input can be eleminated without complicated calculation process. The validity and availability of the proposed algorithm are verified through the experiment.

Study on the Improved Target Tracking for the Collaborative Control of the UAV-UGV (UAV-UGV의 협업제어를 위한 향상된 Target Tracking에 관한 연구)

  • Choi, Jae-Young;Kim, Sung-Gaun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.5
    • /
    • pp.450-456
    • /
    • 2013
  • This paper suggests the target tracking method improved for the collaboration of the quad rotor type UAV (Unmanned Aerial Vehicle) and omnidirectional Unmanned Ground Vehicle. If UAV shakes or UGV moves rapidly, the existing method generates a phenomenon that the tracking object loses the tracking target. To solve the problems, we propose an algorithm that can track continually when they lose the target. The proposed algorithm stores the vector of the landmark. And if the target was lost, the control signal was inputted so that the landmark could move continuously to the direction running out. Prior to the experiment, Proportional and integral control were used in 4 motors in order to calibrate the Heading value of the omnidirectional mobile robot. The landmark of UGV was recognized as the camera adhered to UAV and the target was traced through the proportional-integral-derivative control. Finally, the performance of the target tracking controller and proposed algorithm was evaluated through the experiment.

Design Parameter Analysis of the Proportional Control Valve for Wheel-Loader Automatic Transmission (휠로더 자동변속기용 비례 제어 밸브의 설계 특성 해석)

  • Park, Young-Jun;O, Joo-Young;Yun, Ung-Kwon;Lee, Guen-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.5
    • /
    • pp.27-35
    • /
    • 2010
  • A loader used for uploading materials into truck is a kind of construction equipment. Mainly, a wheel loader is applied to construction work. Recently, an automatic transmission for the wheel loader is used to help drivers get the repetitive works done comfortably. It is composed of geartrain, clutch pack, hydraulic control system and TCU. Especially, a high-performance proportional control valve and its control algorithm is demanded to achieve the shift quality during a change of speed. In this paper, the commercial package program was used in order to justify model of the proportional control valve and simulate it. Steady-state and dynamic characteristics of PCV were analyzed to classify attractive forces and hydraulic control characteristics. This model also was verified the validity compared to the experimental result. Using the developed model, performances of PCV were predicted as studying design parameters.

A comparative analysis on switch performances for congestion controls in ATM Networks (ATM망에서 폭주 제어를 위한 스위치 성능의 비교 분석)

  • 조미령;이상훈
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.4
    • /
    • pp.547-564
    • /
    • 2001
  • In this paper a simulation has been performed to compare and evaluate the performance between the EPRCA(Enhanced Proportional Rate Control Algorithm) and EMRCA(Explicit Max_min Rate Control Algorithm) switches. The variation of the ACR at the source end system, the queue length, the utilization rate of the link bandwidth and the share fairness at the transient and steady states are used as the evaluation criteria for the simulation. The EMRCA switch is more stable than the EPRCA switch and reduces its buffer size. Also, it achieves a higher utilization rate of the link bandwidth than the EPRCA switch. The hardware complexity of the EMRCA switch is significantly lower than the EPRCA and other rate-based switches. Since it eliminates the necessity of the floating-point operation for calculation of the MACR(Mean Allowed Cell Rate) at the switch.

  • PDF