• Title/Summary/Keyword: proper UP-filter

Search Result 16, Processing Time 0.023 seconds

FUZZY PROPER UP-FILTERS OF UP-ALGEBRAS

  • Songsaeng, Metawee;Iampan, Aiyared
    • Honam Mathematical Journal
    • /
    • v.41 no.3
    • /
    • pp.515-530
    • /
    • 2019
  • The concept of fuzzy sets in UP-algebras was first introduced by Somjanta et al. [Fuzzy sets in UP-algebras; 2016]. In this paper, we introduce and study fuzzy proper UP-filters of UP-algebras and prove their generalizations and characteristic fuzzy sets of proper UP-filters. Moreover, we discuss the relations between fuzzy proper UP-filters and their level subsets.

The Output Characteristics Analysis by Cut-off Frequency Set-up of the LCR Filter on NPC Multi-Level Inverter with Trap-Filter (트랩필터를 갖는 NPC멀티레벨 인버터의 LCR필터 차단주파수 설정에 따른 출력특성 분석)

  • Kim, Soo-Hong;Kim, Yoon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.892-897
    • /
    • 2007
  • This paper presents the output filter design and the output characteristic analysis by cut-off frequency set up of the LCR filter on NPC multi-level inverter with trap-filter. The single-phase NPC three-level inverter operates at low switching frequency. The proposed LC trap filter is comprised of a conventional LCR output filter, by using LC trap filter the need for high damping resistor and low LC cut-off frequency is eliminated. Also. low damping resistor is increased the output filter system. The multilevel inverter system used NPC type inverter in proper system for high power application and controller is used DSP(TMS320C31). The effectiveness of proposed system confirmed the validity through SPICE simulation and experimental results.

Evaluation of a Rapid Sand Filter with Surface Wash and Backwash Conditions (정수장 급속여과지 역세척 수위변화와 시간에 따른 세척 효율 평가)

  • Jung, Yong-Jun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.652-656
    • /
    • 2004
  • Both surface wash and backwash are considered as one of the most important methods that can improve the filtration efficiency in the existing water treatment plant. This study has mainly focused on the improvement of filtering efficiency by controlling surface wash and backwash time, and water level before backwash (when drained up to the trough, when drained up to 10 cm above filter bed, and when drained below 10 cm filter bed). Filtration efficiency was shown a little bit of differences depending on the operating conditions like surface wash injection pressure, the distance control between filter bed and the facility, and the types of surface wash. When the water level before backwash was reached up to 10 cm below filter bed after draining, however, the filtration velocity and the turbidity removal efficiency in the filter bed was improved. When the surface wash followed by backwash is longer, it showed a similar result. Because the proper adjustment of surface washing time makes filtration efficiency higher, therefore, it is necessary to set up the backwash time moderately.

Characteristics of High-Rate Filtration with Filtration Aids (급속여과공정에서의 여과보조제 사용에 따른 여과특성)

  • Ahn, Jong-Ho;Yoon, Jae-Heung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.3
    • /
    • pp.260-270
    • /
    • 2000
  • The objective of this study is to evaluate the effect of filter aids in the dual-media rapid filtration. Paper-filter tests were conducted to determine the proper dosages of coagulant and filter aid, and pilot plant tests using two dual-media filter columns were performed for a variety of filtration rates. Using a filter aid (non-ionic polymer), the maximum feasible filtration rate is 480m/day, while turbidity is less than 0.3 NTU and filter run-time is about 70 hours. It is possible to increase the filtration rate up to 360 m/day for keeping the turbidity less than 0.1 NTU. Turbidity increases for the filtration rate greater than 360m/day. In general, the quality of filtered water with a filter aid is stable, while the filter maintains a sufficient filter run-time for a maximum allowable head loss. Particularly, the initial breakthrough can be effectively controlled. The use of a filter aid may be one of the methods applicable if the turbidity of filtered water is required to be improved or if the filter breakthrough limits filter run-time.

  • PDF

A column study of effect of filter media on the performance of sand filter

  • Kim, Tae-hoon;Oh, Heekyong;Eom, Jungyeol;Park, ChulHwi
    • Membrane and Water Treatment
    • /
    • v.11 no.4
    • /
    • pp.247-255
    • /
    • 2020
  • Sand filter is a key unit process for particle removal in water purification treatments. Its long-standing use is due to on-site customized retrofit. Proper selection of filter media is one of the retrofit approaches to improve filter performance. This study described a series of controlled laboratory column tests and examined the effects of media property on filtration and backwash. When sand media of 0.51 mm in effective size was replaced by sand of 0.60 mm, the filter run increased up to 5 times in the given bed depth. The change of media property required an increase of backwash rate by 0.05 m/min to satisfy the requirement of bed expansion, more than 20%. When the anthracite was changed with lower effective size and uniformity coefficient, correlation with sand in the filter bed could be satisfied within the permissible error between media and bulk characteristics. Besides, this selection resulted in a well-stratified configuration of media layers after bed expansion. The column study showed that the correlation of property between the dual media had a significant effect on the filter productivity and backwash interval.

RF Seeker LOS Rate Estimation Method using Covariance and Signal Management (공분산 및 신호관리를 이용한 RF탐색기 시선각 변화율 추정기법)

  • Moon, Gwan-Young;Jun, Byung-Eul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.4
    • /
    • pp.292-299
    • /
    • 2012
  • The line-of-sight(LOS) rate is estimated using Kalman filter in Radio-Frequency(RF) seeker. For the two axis gimbaled seeker, proper system modeling is considered and the basic filter structure is set up. The main issue for Kalman filter is choosing the proper process and measurement noise. For the measurement process, the signal to noise ratio(SNR) and other components are introduced. To cope with the eclipse problem or other abnormal seeker status, the pseudo input signal concept is proposed. By conditioning abnormal signals, the LOS rate estimation performance is increased. The process noise is also an important factor in the propagation phase. The analytical approach on a process noise component is performed and a reliable region for the filter is calculated based on the eigenvalue analysis. Some numerical simulations are performed to check the validity of suggested algorithm.

A transfer alignment algorithm using velocity and quaternion partial matching methods (속도및 쿼터니언 부분 정합방식에 의한 전달정렬 알고리즘)

  • Song, Ki-Won;Jeon, Chang-Bae;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.3
    • /
    • pp.238-243
    • /
    • 1997
  • A new transfer alignment algorithm using the velocity and the quaternion partial matching methods is proposed to reduce the effect of a ship's Y-axis flexure on the performance of azimuth error estimation of Kalman filter. The simulation results show that it can significantly reduce the effect of Y-axis flexure on error estimation by the transfer alignment algorithm. As its results, azimuth transfer alignment error is reached up to 3 mrad under proper roll and pitch attitude motion of the ship.

  • PDF

The Evaluation of Evenness of Nonwovens Using Image Analysis Method

  • Jeong, Sung-Hoon;Kim, Si-Hwan;Hong, Cheol-Jae
    • Fibers and Polymers
    • /
    • v.2 no.3
    • /
    • pp.164-170
    • /
    • 2001
  • Authors studied on the applicability of image analysis technique using a scanner with a CCD (charged coupled deviced) to the evaluation of evenness of nonwovens because it has distinctive features to considerably save time and labor in the analysis compared with other classical methods. As specimens fur the experiment, two different types that are unpatterned and patterned ones were prepared. For the unpatterned specimen, webs were chemically bonded, while for the patterned specimen, webs being thermally calendered with engraved roller. Several webs having various areal densities were prepared and bonded. Coefficient of variation (CV%) was used as a parameter to evaluate the evenness. Scanning conditions could be suitably set up through comparing the total variance to the between-group variance and to the within-group variance, respectively, on the images scanned at the different conditions. The 2D convolution method with smoothing filter kernel was introduced to further filter the noises on the scanned images. After the filtering process, the increase of web areal densities gave an uniform decrease of the CV%. This showed that the scanned image analysis with proper filtering process could be successfully applicable to the evaluation of evenness in nonwovens.

  • PDF

Laboratory Production of Oospores in Pseudoperonospora humuli (Pseudoperonospora humuli의 실험실상의 난포자 형성)

  • ;Robert E. Klein
    • Korean Journal Plant Pathology
    • /
    • v.14 no.6
    • /
    • pp.618-621
    • /
    • 1998
  • In pseudoperonospora humuli, the cause of hop downy mildew, environmental and host factors affecting laboratory production of oospore were examined. After 7 days incubation of leaf disk inoculated with sporangia on water, additional incubations were carried out under different conditions of temperature and moisture. Oospore production was also compared between very susceptible (Nugget) and resistant (Fuggle) hop cultivars. Oospores were not produced at 18$^{\circ}C$ regardless of other incubation conditions. Leaf disks failed to produce oospore when incubated on water for up to 18 days at 8$^{\circ}C$. No oospores formed on infection sites without necrosis. However, abundant oospores were produced at necrotized infection sites when inoculated leaf disk incubated on dry filter paper for 5 days at 8$^{\circ}C$. Both susceptible and resistant hop cultivars produced abundant oospores. In the measurement of optimal temperature for oospore production, oospores were produced at 6 to 12$^{\circ}C$ Most abundant oospores were produced at 8$^{\circ}C$. We suggest that proper combination of low temperature, dryness and necrosis may be a critical environmental factors for oospore production of P. humuli.

  • PDF

Development of a High Voltage Semiconductor Switch for the Command Charging o (모듈레이터의 지령충전을 위한 고전압 반도체 스위치 개발)

  • Park, S.S.;Lee, K.T.;Kim, S.H.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2067-2069
    • /
    • 1998
  • A prototype semiconductor switch for the command resonant charging system has been developed for a line type modulator, which charges parallel pulse forming network(PFN) up to voltage of 5 kV at repetition rates of 60 Hz. A phase controlled power supply provides charging of the 4.7 ${\mu}s$ filter capacitor bank to voltage up to 5 kV. A solid state module of series stack array of sixe matched SCRs(1.6 kV, 50 A) is used as a command charging switch to initiate the resonant charging cycle. Both resistive and RC snubber network are used across each stage of the switch assembly in order to ensure proper voltage division during both steady state and transient condition. A master trigger signal is generated to trigger circuits which are transmitted through pulse transformer to each of the 6 series switch stages. A pulse transformer is required for high voltage trigger or power isolation. This paper will discuss trigger method, protection scheme, circuit simulation, and test result.

  • PDF