• Title/Summary/Keyword: progressive failure

Search Result 416, Processing Time 0.023 seconds

Compression-Compression Fatigue Behavior of Al-Si-Ca alloy Foams (Al-Si-Ca 합금 폼의 압축 피로 거동)

  • Lee, Chang-Hun;Ha, San;Kim, Am-Kee;Jeong, Gil-Do
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.190-195
    • /
    • 2004
  • The compression-compression fatigue properties of the closed cell Al-Si-Ca alloy foams have been studied. The monotonic and cyclic compressive properties were compared with each other and the fatigue stress-life (S-N) curves were presented. In compression-compression fatigue, the crushing was found to initiate in a single band which broadens gradually with additional fatigue cycles. Progressive shortening of the specimen took place due to a combination of low cycle fatigue failure and cyclic ratcheting which is in accordance with the findings of previous researchers [1-3]. Young's modulus of the foam was found to decrease with the increasing strain in case of fatigue test however in case of monotonic compression test the value of Young's modulus increased with the strain (number of cycles). The endurance limit on the basis of $10^{7}$ cycles obtained by extrapolating the experimental results were 0.98 MPa and 1.70 MPa for load ratios 0.1 and 0.5 respectively which are 34 % and 59 % of the plateau stress.

  • PDF

Estimation of Flexural Rigidity of R/C Beam Strengthened with CFS subjected to repeated loadings (반복하중을 받는 CFS로 보강된 R/C 보의 휨 강성 평가)

  • Kim, Chung-Ho;Jang, Jong-Wan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.2
    • /
    • pp.231-238
    • /
    • 2004
  • The deterioration of the flexural capacity by progressive crack and over deflection in R/C bridges is developed actually from the dynamic repeated loading due to vehicle traffics. Such a fact suggest a necessities of confirmation and estimation of the data acquired from monotonic incremental loading test. Therefore, this study carry out the monotonic incremental loading test and dynamic repeated loading test in R/C beams strengthened with CFS. By dynamic repeated loading test, the experiments confirmed the validities and fittness of the results acquired from monotonic incremental loading test and estimated the characteristics of the moment-curvature, degradation of the flexural rigidity, crack and failure.

A Case of Pachydermoperiostosis (경피골막증: 증례보고)

  • Nam, Young O;Ko, Sung Hoon;Oh, Suk Joon
    • Archives of Plastic Surgery
    • /
    • v.35 no.3
    • /
    • pp.316-320
    • /
    • 2008
  • Purpose: Pachydermoperiostosis is a rare hereditary disease characterized by finger clubbing, periosteal reaction, and pachydermia. The underlying pathogenic mechanism of this disease remains unclear. This disease is known to be associated with a variety of diseases such as cranial suture defect, bone marrow failure, hypertrophic gastropathy, Crohn's disease, and female escuchen. Methods: A 50-year-old male had digital clubbing of both hands, coarse hypertrophic skin changes of face, progressive thickening and furrowing on the scalp(cutis verticis gyrata), persistent pain in the limbs and joints. Other cutaneous features include moderate blepharoptosis, pole-like lower legs and feet. Results: We performed surgical excision for hypertrophic skin change of scalp because of frequent eczematous skin change, severe itching sensation and cosmetic problem. Diagnosis is confirmed by bony proliferative periosteal reaction, pathologic findings, and characteristic clinical findings. Conclusion: Pachydermoperiostosis is manifested by finger clubbing, and hypertrophic skin changes causing coarse facial features with thickening and periosteal bone formation. We experienced a case of pachydermoperiostosis. Brief review of related literature is given.

A Review of Total Correction in 48 Cases of Tetralogy of Fallot (Fallot 사징증(四徵症) 외과적(外科的) 완전교정(完全矯正)에 대한 임상적(臨床的) 고찰(考察))

  • Suh, Kyung Phill
    • Journal of Chest Surgery
    • /
    • v.9 no.2
    • /
    • pp.198-206
    • /
    • 1976
  • A Total of Forty eight patients underwent open-heart surgery for correction of tetralogy of Fallot at the Seoul National University Hospital from January 1974 to October 1976, with an overall survival rate of 77 per cent. Operative mortality varied according to severity of the lesion, age of the patient, nature of previous surgical treatment and presence or absence of an outflow tract patch across the pulmonary valve ring. Eleven patients died in the early postoperative period and thirty seven patients were discharged from the hospital alive. A patch of the right ventricular outflow tract and pulmonary annulus was required to relieve pulmonic stenosis in 24 patients. There were 10 deaths in this group (42%) as compared to 1 death in the group of 24 patients who were corrected without a patch. Operative mortality was especially higher when an inlay patch was placed across the pulmonary valve ring. This may be related to the possibly greater anatomic severity of these cases and to the longer operating time when a patch was used. The electrocardiogram showed right ventricular hypertrophy in 35 cyanotic patients. Intraventricular conduction was normal in 34 patients before operation. It was normal postoperatively in only 5 of 34 patients in this group who survived surgery. Complete right bundle branch block appeared at operation in 21 patients, and 8 patients developed incomplete right bundle branch block. Major causes of death were progressive cardiac failure (4), Complete atrioventricular dissociation (3), bleeding (2), cardiac tamponade (1), and sudden cardiac arrest (1)

  • PDF

Analytical Approach of Sliding Installation Method with Spar Structure

  • Lee, Jong-Hyun
    • Journal of Navigation and Port Research
    • /
    • v.35 no.7
    • /
    • pp.575-580
    • /
    • 2011
  • It is important to understand the trajectory of structure in launching process because of the short time of launching process may result in unexpected accidents or damage to structures. The high risk of structural failure is not avoidable without the fully comprehension of changing forces in launching procedure. The commercial software can evaluate the motion of launching event in calm water condition but there is the limitation of research application because of the programmed commercial software. The launching process of the spar hull is suggested with stage concept that is divided into 10 stages in time domain. A force equilibrium diagram is derived for each stage where the changes of force vector and motion characteristics take place. In particular, the effects of changes in buoyancy and drag force due to the progressive submergence of the spar hull are taken into account by means of a touch length concept. The results contained in this paper provide the valuable information of the trajectory motion evaluation with suggested methods in spar launching process with sliding barge. Furthermore, the presented stage concept and touch length concept will provide basic knowledge for understanding launching process and help to develop further research area for launching analysis.

Disseminated Scedosporium apiospermum Infection Induced from Aspiration Pneumonia after Near-Drowning (익수 후 발생한 흡인성 폐렴에서 유발된 파종성 Scedosporium apiospermum 감염 1예)

  • Won, Ho-Youn;Kim, Hyung-Rae;Kim, Dong-Hwan;Oh, Jae-Won;Ki, Jung-Hye;Han, Chang-Hun;Lee, Sun-Min;Kim, Cheong-Ju
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.4
    • /
    • pp.298-302
    • /
    • 2010
  • Scedosporium apiospermum, the anamorph of Pseudallescheria boydii, is a ubiquitous saprophytic fungus. S. apiospermum can cause life-threatening infections usually in immunocompromised patients or after near-drowning incidents. Here, we report the first case of disseminated infection caused by S. apiospermum after near-drowning in Korea. A 44-year-old healthy man developed aspiration pneumonia, followed by multiple brain abscesses, and endopthalmitis, after a near-drowning incident in a septic tank. S. apiospermum infection was diagnosed on the 33rd day after the incident had occurred. The patient died from the progressive renal failure 255 days after incident, although he had been treated with voriconazole.

Paradoxical Exacerbation of Symptoms with Obstruction of the Venous Outflow after Gamma Knife Radiosurgery for Treatment of a Dural Arteriovenous Fistula of the Cavernous Sinus

  • Ko, Jun Kyeung;Cho, Won Ho;Lee, Tae Hong;Choi, Chang Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.2
    • /
    • pp.127-130
    • /
    • 2015
  • A 59-year-old female presented with progressive right proptosis, chemosis and ocular pain. An imaging work-up including conventional catheter angiography showed a right-sided dural arteriovenous fistula of the cavernous sinus, which drained into the right superior petrosal sinus, right superior ophthalmic vein, and right inferior ophthalmic vein, and cortical venous reflux was seen via the right petrosal vein in the right posterior fossa. After failure of transvenous embolization, the patient underwent Gamma Knife radiosurgery (GKRS). At one month after GKRS, she developed increasing ocular pain and occipital headache. Repeat angiography showed partial obliteration of the fistula and loss of drainage via the superior and inferior ophthalmic veins with severe congestion, resulting in slow flow around the right cerebellar hemisphere. Prompt transarterial embolization relieved the patient's ocular symptoms and headache. We report on a case of paradoxical exacerbation of symptoms resulting from obstruction of the venous outflow after GKRS for treatment of a dural arteriovenous fistula of the cavernous sinus.

Structural Analysis and Strain Monitoring of the Filament Wound Composite Motor Case used in KSR-III Rocket (KSR-III 삼단 복합재 연소관의 구조 해석 및 변형률 측정)

  • 박재성;김철웅;조인현;오승협;홍창선;김천곤
    • Composites Research
    • /
    • v.14 no.6
    • /
    • pp.24-31
    • /
    • 2001
  • Filament wound structures such as pressure tanks, pipes and motor cases of rockets are widely used in the aerospace application. The determination of a proper winding angle and thickness is very important to decrease manufacturing difficulties and to increase structural efficiency. In this study, possible winding angles considering the slippage between a fiber and a mandrel surface are calculated using the semi-geodesic path equation. In addition, finite element analysis using ABAcUS are performed to predict the behavior of filament wound structures considering continuous change of winding angle along the dome part. The water-pressuring tests of 3rd stage motor case are performed to verify the analysis procedure. The strain gages are attached on the surface in the fiber direction. Progressive failure analysis is performed to predict the burst pressure and the weakest region of the motor case. The effect of reinforcement is also studied to increase its performance.

  • PDF

Numerical Simulation of High Velocity Impact of Circular Composite Laminates

  • Woo, Kyeongsik;Kim, In-Gul;Kim, Jong Heon;Cairns, Douglas S.
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.2
    • /
    • pp.236-244
    • /
    • 2017
  • In this study, the high-velocity impact penetration behavior of $[45/0/-45/90]_{ns}$ carbon/epoxy composite laminates was studied. The considered configuration includes a spherical steel ball impacting clamped circular laminates with various thicknesses and diameters. First, the impact experiment was performed to measure residual velocity and extent of damage. Next, the impact experiment was numerically simulated through finite element analysis using LS-dyna. Three-dimensional solid elements were used to model each ply of the laminates discretely, and progressive material failure was modeled using MAT162. The result indicated that the finite element simulation yielded residual velocities and damage modes well-matched with those obtained from the experiment. It was found that fiber damage was localized near the impactor penetration path, while matrix and delamination damage were much more spread out with the damage mode showing a dependency on the orientation angles and ply locations. The ballistic-limit velocities obtained by fitting the residual velocities increased almost linearly versus the laminate diameter, but the amount of increase was small, showing that the impact energy was absorbed mostly by the localized impact damage and that the influence of the laminate size was not significant at high-velocity impact.

Determination of limiting temperatures for H-section and hollow section columns

  • Kwon, In-Kyu;Kwon, Young-Bong
    • Steel and Composite Structures
    • /
    • v.13 no.4
    • /
    • pp.309-325
    • /
    • 2012
  • The risk of progressive collapse in steel framed buildings under fire conditions is gradually rising due to the increasing use of combustible materials. The fire resistance of such steel framed buildings is evaluated by fire tests. Recently, the application of performance based fire engineering makes it easier to evaluate the fire resistance owing to various engineering techniques and fire science. The fire resistance of steel structural members can be evaluated by the comparison of the limiting temperatures and maximum temperatures of structural steel members. The limiting temperature is derived at the moment that the failure of structural member results from the rise in temperature and the maximum temperature is calculated by using a heat transfer analysis. To obtain the limiting temperatures for structural steel of grades SS400 and SM490 in Korea, tensile strength tests of coupons at high temperature were conducted. The limiting temperatures obtained by the tensile coupon tests were compared with the limiting temperatures reported in the literature and the results of column fire tests under four types of loading with different load ratios. Simple limiting temperature formulas for SS400 and SM490 steel based on the fire tests of the tensile coupons are proposed. The limiting temperature predictions using the proposed formulas were proven to be conservative in comparison with those obtained from H-section and hollow section column fire tests.