• 제목/요약/키워드: profilometry

검색결과 83건 처리시간 0.031초

한약재 추출물 함유 앰플의 주름개선 효능에 관한 기초 임상연구 (The Efficacy of Ampule Containing Herbal Extract for Improving Skin Wrinkles in Women)

  • 도은주;이진상;박현진;하일도;김영철;김미려
    • 대한한의학방제학회지
    • /
    • 제17권2호
    • /
    • pp.111-121
    • /
    • 2009
  • Objectives : This study was performed to evaluate the efficacy of ampule containing herbal extract(Ulmus davidiana, Ginkgo biloba, Perilla ocymoides, Morus alba, Glycyrrhiza uralensis (licorice), and Angelica gigas) on skin wrinkles in adult women with facial wrinkles. Methods : A total of 12 women, 30 to 46 years of age, with wrinkles in the corner of eyes, applied ampule containing herbal extract twice daily for up to 12 weeks. Silicon replicas of right crow's feet area and antecubital fossa were taken before use of test product and at 4, 8 and 12 weeks. The replicas were analyzed by optical profilometry with Skin Visiometer SV600. The wrinkle and roughness parameters, R1, R2, R3, R4 and R5 were calculated and statistically analyzed. In addition, a subjective evaluation of product efficacy was conducted by patient's assessment. Results : The mean values of all the skin roughness parameters were decreased at 4-week, and decreased significantly at 8 and 12-week except R4 at 12-week after test product use. The subjective evaluation of wrinkle by patient's assessment was also improved. However, one patient noted stiffness of face after use of test product. Conclusions : These study suggested that the application of ampule containing herbal extract twice daily for 12 weeks may effectively improve the facial wrinkles without severe side effect.

  • PDF

위상천이법을 이용한 삼차원 형상측정에서 위상오차 보정 (Phase error compensation for three-dimensional shape measurement based on a phase-shifting method)

  • 박윤창;안성준;강문호;권영철;안승준
    • 한국산학기술학회논문지
    • /
    • 제10권11호
    • /
    • pp.3023-3030
    • /
    • 2009
  • 고속 삼차원 형상측정에서는 충분한 위상이송 스텝 수를 적용할 시간을 확보할 수 없기 때문에, 스텝 수를 축소하게 되면서 위상측정에서의 잡음이 증가되게 된다. 본 논문에서는, 다파장 PMP법에 있어서 두 파장의 비례관계를 이용하여 측정된 위상에 포함되어 있는 위상오차를 예측하고, 이를 보정하는 방법을 제안하였으며, 제안된 보정방법의 효용성을 확인하기 위한 실험이 진행되었다. 위상천이법에서 통상적으로 사용되는 스텝 수에 비해 월등히 많은 스텝의 위상 이송으로 측정하였으며, 또한 동일한 대상물을 고속 삼차원측정에서 적용되는 3-3 step의 위상 이송으로 측정하여, 두 경우에서의 측정결과를 비교하여 고속측정에서의 측정잡음을 산출하였다. 그리고, 본 논문에서 제안하고 있는 보정 방법을 측정된 맥놀이 위상과 절대위상에 적용한 결과, 각각에 있어서 90%와 17.2%의 잡음감소가 이루어지는 것으로 확인되었다.

피부 주름 평가에 있어서의 피부 거칠기와 진피 치밀도의 상관성 연구 (Correlation Between Skin Roughness and Dermal Density of Skin Wrinkle Evaluation)

  • 이희경;백지훈;고재숙;박덕훈;이종성;정은선
    • 대한화장품학회지
    • /
    • 제32권2호
    • /
    • pp.123-127
    • /
    • 2006
  • 건강하고 병력이 없는 피부를 가진 한국인 여성 중 주름이 생성되기 시작하거나 이미 생성된 30대 33명, 40대 56명, 50대 6명 등 총 95명을 대상으로 눈가에 대한 피부 거칠기와 진피 치밀도 및 피부 두께 측정값간에 상관관계를 확인하였다. 피부거칠기는 Visiometer를 이용하여 5가지 파라미터(Rl, R2, R3, R4, R5)를 분석하였고, 피부 진피 치밀도는 초음파 영상 장치인 Dermascan C를 이용하여 진피 치밀도(intensity)와 피부 두께(distance)를 측정하여 분석하였다. 분석 결과 연령에 따라 피부 거칠기와 진피 치밀도 및 피부 두께간의 깊은 관련성을 확인하였다. 피부 주름 거칠기 파라미터 중에서는 R2 (Maximum roughness)가 피부 두께와 유의한 상관관계가 있었으며(p < 0.05) 또한, 진피 치밀도가 증가함에 따라 피부 두께는 유의하게 감소하는 경향을 보였다(p < 0.05). 따라서 주름 측정 방법에 있어서 기존의 레플리카를 이용한 피부 거칠기 평가 기술과 더불어 진피층의 변화를 측정하는 진피 치밀도 평가 기술은 주름 평가에 매우 유용한 방법이라고 판단된다.

Carbohydrate-electrolyte drinks exhibit risks for human enamel surface loss

  • de Melo, Mary Anne Sampaio;Passos, Vanara Florencio;Lima, Juliana Paiva Marques;Santiago, Sergio Lima;Rodrigues, Lidiany Karla Azevedo
    • Restorative Dentistry and Endodontics
    • /
    • 제41권4호
    • /
    • pp.246-254
    • /
    • 2016
  • Objectives: The aim of this investigation was to give insights into the impact of carbohydrate-electrolyte drinks on the likely capacity of enamel surface dissolution and the influence of human saliva exposure as a biological protective factor. Materials and Methods: The pH, titratable acidity (TA) to pH 7.0, and buffer capacity (${\beta}$) of common beverages ingested by patients under physical activity were analyzed. Then, we randomly distributed 50 specimens of human enamel into 5 groups. Processed and natural coconut water served as controls for testing three carbohydrate-electrolyte drinks. In all specimens, we measured surface microhardness (Knoop hardness numbers) and enamel loss (profilometry, ${\mu}m$) for baseline and after simulated intake cycling exposure model. We also prepared areas of specimens to be exposed to human saliva overnight prior to the simulated intake cycling exposure. The cycles were performed by alternated immersions in beverages and artificial saliva. ANOVA two-way and Tukey HDS tests were used. Results: The range of pH, TA, and ${\beta}$ were 2.85 - 4.81, 8.33 - 46.66 mM/L and 3.48 - $10.25mM/L{\times}pH$, respectively. The highest capacity of enamel surface dissolution was found for commercially available sports drinks for all variables. Single time human saliva exposure failed to significantly promote protective effect for the acidic attack of beverages. Conclusions: In this study, carbohydrate-electrolyte drinks usually consumed during endurance training may have a greater capacity of dissolution of enamel surface depending on their physicochemical proprieties associated with pH and titratable acidity.

위상 보정을 통한 Fringe Pattern Profilometry 3D 측정의 정확성 개선 (Improvement of the Accuracy of Fringe Pattern Profilometry 3D Measurements through Phase Correction)

  • 김호중;조태훈
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.389-392
    • /
    • 2016
  • 기술이 발전하면서 카메라를 통해 3D 측정을 하는 방법은 계속 발전되어 왔다. 3D 측정을 하는데 있어서 신경 써야 할 요소로는 속도, 정확성, 쉬운 구현 등이 있다. 최근 들어서는 여러 주기의 Fringe pattern을 이용한 측정 방법이 나왔고 많이 쓰이고 있는 추세이다. 이 방법은 일반적으로 프로젝터를 통해 사인파를 뿌려서 얻은 영상으로 높이를 측정하는 방법이다. 이때 사인파를 소프트웨어적으로 생성하여 뿌리는데, 생성된 패턴은 완벽한 사인파일지라도 프로젝터로 뿌릴 때는 감마에 의해서 완벽한 사인파가 될 수가 없다. 이것은 높이 측정에 악영향을 주어, 보다 정확한 높이를 측정할 수 없게 한다. 따라서 본 논문에서는 감마 영향을 받지 않기 위해 사인파의 위상에 대한 보정 방법을 제안한다. 이 방법을 통하여 보다 정확한 높이 측정을 할 수 있을 것이다.

  • PDF

피치가변격자를 이용한 자유곡선 형상측정에 관한 연구 (A Study on the Measurement of 3-D object, make use of grid fringe generator)

  • 박윤창;정경민;박경근;장석준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.19-22
    • /
    • 2000
  • Noncontact measuring methodology of 3-dimensional profile using CCD camera are very attractive because of it's high measuring speed and its's high sensitivity. Especially, when projecting a grid pattern over the object the captured image have 3 dimensional information of the object. Projection moire extract 3-D information with another grid pattern in front of CCD camera. However phase measuring profilometry(PMP) obtain similar results without additional grid pattern. In this paper, new method for grid pattern generation system by polygonal mirror and Laser Diode. This system is applied the projection moire and the PMP.

  • PDF

PCD 공구에 의한 Graphite/Epoxy 복합재료 가공시 발생하는 표면조도의 특성 연구

  • 왕덕현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1992년도 추계학술대회 논문집
    • /
    • pp.101-105
    • /
    • 1992
  • Machined graphite/epoxy composite surfaces were studied by using SEM(Scanning Electron Microscopy). surface profilometry and its analysis to determine suitable surface describing parameters for machined unidirectional and laminate composite surface. The surface roughness and profile are found to be highly dependent on the fiber layup direction and the measurement direction. Machined unidirectional and 0.deg. 45 .deg. 90 .deg. plies in laminate composite surface profiles are found to be Gaussian in the direction of machining. Since there exist bare fibers without matrix smearing in 0 .deg. ply, higher surface roughness values were found in this orientation. It was possible to machine 90 .deg. and -45 .deg. plies due to the adjacent plies, which were holding those plies. It was found that the microgeometrical variations in terms of roughness parameters Ra without Dy (maximum Damage Depth) region and Dy are better descriptors of the machined laminate composite surface than commonly used roughness parameters Ra and Ra. The characteristics of surface profiles in laminate composite are well represented in CHD (Cumulative Height Distribution) plot and PPD (Percentage Probability Density) plot. Also, the power spectral density function is shown to be capable of identifying the wavelength distribution of the machining damage.

Effect of bath conditions and pulse parameters on tin surface finish for microelectronic packaging applications

  • Sharma, Ashutosh;Jung, Do-hyun;Jung, Jae-pil
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2015년도 추계학술대회 논문집
    • /
    • pp.232-233
    • /
    • 2015
  • The effects of various bath conditions such as surfactant concentration, bath pH, bath temperature, agitation of bath; as well as pulse parameters such as cathodic current density, pulse duty cycle and frequency, on the grain size, surface finish, and appearance of the tin plated coatings have been investigated. The plating bath under investigation is an aqueous acidic solution composed of a mixture of $SnSO_4$, $H_2SO_4$, and a surfactant. The bath conductivity and pH are measured by a glass pH electrode. The microstructure of the coatings produced is characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), and surface profilometry. XRD analysis shows that the deposits consist of tetragonal ${\beta}$-Sn crystal structure irrespective of plating conditions. The mechanism involved in the morphology evolution in response to various parameters and conditions has also been discussed.

  • PDF

Effect of nitrogen doping on properties of plasma polymerized poly (ethylene glycol) film

  • Javid, Amjed;Long, Wen;Lee, Joon S.;Kim, Jay B.;Sahu, B.B.;Jin, Su B.;Han, Jeon G.
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2014년도 추계학술대회 논문집
    • /
    • pp.286-288
    • /
    • 2014
  • This study deals with the catalyst free radio frequency plasma assisted polymerization of ethylene glycol using nitrogen as reactive gas to modify the surface chemistry and morphology. The deposited film was characterized through various analysis techniques i.e. surface profilometry, Forier transform infrared spectroscopy, water contact angle and UV-visible spectroscopy to analyze film thickness, chemical structure, surface energy and optical properties respectively. The surface topography was analyzed by Atomic force microscopy. It was observed that the ethylene oxide behaviour and optical transmittance of the film were reduced with the introduction of nitrogen gas due to higher fragmentation of monomer. However the hydrophilic behavior of the film improved due to formation of new water loving functional groups suitable for biomedical applications.

  • PDF

Formation and Growth of Hydride Blisters in Zr-2.5Nb Pressure Tubes

  • Cheong, Yong-Moo;Gong, Un-Sik;Choo, Ki-Nam;Kim, Sung-Soo;Kim, Young-Suk
    • Nuclear Engineering and Technology
    • /
    • 제33권2호
    • /
    • pp.192-200
    • /
    • 2001
  • Hydride blisters were formed on the outer surface of Zr-2.5Nb pressure tube by a non- uniform steady thermal diffusion process. A thermal gradient was applied to the pressure tube with a heat bath kept at a temperature of 415$^{\circ}C$ and an aluminum cold finger cooled with flowing water of 15$^{\circ}C$. Optical microscopy and tree-dimensional laser profilometry were used to characterize the hydride blisters with different hydrogen concentrations and thermal diffusion time. Hydride blisters were expected to start at a hydrogen concentration of 30 - 70 ppm and a thermal diffusion time of 4 - 6$\times$10$^{5}$ sec. The hydride blister size increases with higher hydrogen concentrations and longer thermal diffusion time . Some of the samples revealed cracks on the hydride blisters. The ratio of hydride blister depth to height was estimated as approximately 8: 1.

  • PDF