• Title/Summary/Keyword: probe penetration

Search Result 75, Processing Time 0.022 seconds

Improved MudFork Penetration Test and its Application (개량된 머드포오크 관입시험 장치의 개발 및 적용)

  • Kim, Hak-Sung;Mok, Young-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1365-1371
    • /
    • 2009
  • A new s-wave probe, called "MudFork", has been recently developed and is used in accurate measurements of shear wave velocities of soft soils. In previous researches, some instrumental defects of the probe have been reported. Bending deformation of probe is caused by small section modulus of blades, and open-ended bender elements are vulnerable to damage during penetration. Herein, we improved the MudFork to solve these problems. Field tests at Sinan, Jeollanamdo using the improved MudFork were conducted. Results from MPT are compared with the results from CPT.

  • PDF

Soil Investigation by Helical Probe Test (나선심사시험에 의한 지반조사기법)

  • ;Yokel, Felix Y.
    • Geotechnical Engineering
    • /
    • v.3 no.4
    • /
    • pp.31-40
    • /
    • 1987
  • A helical probe test (HPT) suitable for in.situ soil exploration to a shallow depth and compaction control were developed and tested in different soils alongside traditional in-situ tests, including Standard Penetration Test (SPT), Cone Penetration Test (CPT) and in-situ density test. The helical probe test is economical and can be performed by a single person. The torque necessary to insert the probe Is used as a measure of soil characteristics. It was found that: the HPT test correlates well with the SPT test and the correlation is not sensitive to the soil type; the HPT test correlates well with the CPT test, but the correlation is sensitive to the soil type; the HPT torque provides a sensitive measure of relative compaction rind in-situ dry density of compacted soils; the reverse torque ratio decreases with increasing average grain sloe.

  • PDF

Application of Temperature-compensated Resistivity Probe in the Field (온도보상형 전기저항 프로브의 현장 적용성 평가)

  • Jung, Soon-Hyuck;Yoon, Hyung-Koo;Lee, Jong-Sub
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4C
    • /
    • pp.117-125
    • /
    • 2011
  • The practical use of the electrical resistivity, which can makes the acquirement of the high resolution data in specific area, is increased in order to obtain a reasonable data for a ground investigation. The objective of this study is development of TRPF(Temperature-compensated Resistivity Probe for Field test), and an application in the field test for obtaining a reliable electrical resistivity value about considering the temperature effects. Temperature sensor is attached at 15mm, 30mm, 90mm below from the cone tip in consideration with the results of temperature transient process of cone probe and safety, and the angle of cone tip is $60^{\circ}$ for geometrical reason and minimizing the disturbance during the penetration test. Diameter of the cone probe is equally 35.7mm and penetration rate is 2 cm/sec for a comparison with standard cones such as CPT and SPT, and others. The temperature change is instantly observed around $4^{\circ}C$ when touching the ground, and the comparing results among the other cones indicates that the temperature compensation should be conducted in the ground survey using the electrical resistivity. This study shows that the necessity of temperature effects compensation during penetration test through the development and field verification of TRPF (Temperature-compensated Resistivity Probe for Field test).

Characterizations of Moisture-Sealed Waveguide-to-Microstrip Transitions for Ka-band Transceivers

  • Kim, Kang-Wook;Na, Chae-Ho;Woo, Dong-Sik
    • Journal of electromagnetic engineering and science
    • /
    • v.2 no.2
    • /
    • pp.105-111
    • /
    • 2002
  • New high-performance Ka-band waveguide-to-microstrip transitions for millimeter-wave transceiver applications have been developed and characterized. These transitions are probe-type, but the dielectric material completely covers the whole waveguide aperture, thus providing moisture-barrier and robustness in the probe section. The new probe transitions are also designed to be less sensitive to fabrication tolerances. Further performance enhancements have been obtained by placing vias around the waveguide aperture. Also, the resonance phenomena associated with waveguide wall-penetration have been identified. The developed probe transitions provide insertion loss less than 0.4 dB over entire Ka-band frequencies, but can be optimized for narrowband applications with insertion loss less than 0.2 dB.

Array-Based Real-Time Ultrasound and Photoacoustic Ocular Imaging

  • Nam, Seung Yun;Emelianov, Stanislav Y.
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.151-155
    • /
    • 2014
  • Although various ophthalmic imaging methods, including fundus photography and optical coherence tomography, have been applied for effective diagnosis of ocular diseases with high spatial resolution, most of them are limited by shallow imaging penetration depth and a narrow field of view. Also, many of those imaging modalities are optimized to provide microscopic anatomical information, while functional or cellular information is lacking. Compared to other ocular imaging modalities, photoacoustic imaging can achieve relatively deep penetration depth and provide more detailed functional and cellular data based on photoacoustic signal generation from endogenous contrast agents such as hemoglobin and melanin. In this paper, array-based ultrasound and photoacoustic imaging was demonstrated to visualize pigmentation in the eye as well as overall ocular structure. Fresh porcine eyes were visualized using a real-time ultrasound micro-imaging system and an imaging probe supporting laser pulse delivery. In addition, limited photoacoustic imaging field of view was improved by an imaging probe tilting method, enabling visualization of most regions of the retina covered in the ultrasound imaging.

Porosity Evaluation of Offshore Soft Soils by Electrical Resistivity Cone Probe (전기비저항 콘 프로브를 이용한 해안 연악 지반의 간극률 산정)

  • Kim, Joon-Han;Yoon, Hyung-Koo;Choi, Yong-Kyu;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.2
    • /
    • pp.45-54
    • /
    • 2009
  • The electrical characteristics of soils have been used for investigating soil properties. The purpose of this study is the development and application of the electrical resistivity cone probe (ERCP) for the evelation of the porosity in the field with high precision. The shape of the probe tip is a cone shape to minimize the disturbance during penetration. In addition, the four terminal pair configuration is adopted to minimize the electrical interference. The electrical resistances are continuously measured during penetration of the ERCP using penetration rigs with 0.33 mm/sec penetration rate at Incheon and Busan sites. With the measured resistance profile and electrical resisivity of electrolyte of undisturbed samples, soil porosity profiles are obtained by using Archie's law. The empirical coefficients for the Archie's law are obtained based on the electrolyte extracted from the undisturbed samples. The estimated porosity profiles show similar trends to those of in-situ penetration tests such as SPT, CPT, and DMT. This study suggests that the ERCP may be an effective tool for the porosity estimation in the field with minimum disturbance.

A New Strength Equation of Concrete by Penetration Resistance Test (관입시험법에 의한 콘크리트의 강도 추정)

  • Park Song-chul;Yoo Jae-Eun;Kim Min-Su;Kwon Young-Wung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.125-128
    • /
    • 2004
  • This study concerns the new estimated strength equation of concrete by penetration test. There are not only few estimate strength equations of concrete, but also many problems to apply them because of time, cost, easiness, structural damage, reliability and so on. In this study, there performed a series of penetration test with in 730days' concrete structures and proposed equations as follows; $$Linear\;:\;f_{ck}=2.95d-80.0(r^2= 69.8\%)$$ $$Quadratic\;:\;f_{ck}=0.204d^2-12.15d+193.2(r^2=83.6\%)$$ here, fck : Estimated compressive strength of concrete by MPa d: exposed probe length by mm.

  • PDF

Evaluation of Disturbance Effect of Penetrometer by Dissipation Tests (소산 실험을 이용한 관입 장비의 교란 효과 추정)

  • Yoon, Hyung-Koo;Hong, Sung-Jin;Lee, Woojin;Lee, Jong-Sub
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6C
    • /
    • pp.339-347
    • /
    • 2008
  • The penetration of the probe produces the excess pore pressure due to the disturbance. The objective of this study is to evaluate the disturbance zone by using the dissipation of the excess pore water pressure, which was generated due to the penetration of the penetrometer with different size. The CPT, DMT and FVP (Field Velocity Probe) are adopted for in-situ tests. The tests are carried out in the construction site of north container pier of Busan new port, Korea where is accelerating the consolidation settlement using plastic board drains (PBD) and surcharges by crushed gravels. The coefficient of consolidation $(C_h)$ and soil properties are deduced by the laboratory test. The in-site tests are performed after the predrilling the surcharge zone at the point of 90% degree of consolidation. To minimize the penetration effect, the horizontal distance between penetration tests is 3m, the change of the pore pressure is monitored at the fixed depth of 24m. The coefficient of consolidation $(C_h)$ and the $t_{50}s$ are calculated based on the laboratory test and the in-situ data, respectively. The equvalent radi based on the $t_{50}$ shows that the FVP and the DMT produce the smallest and the greatest equivalent radi, respectively.

A New Estimated Strength Equation of Concrete by Penetration Resistance Test (관입시험법에 의한 콘크리트의 압축강도 추정식)

  • 권영웅;신정식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.643-646
    • /
    • 2003
  • This study concerns the new estimated strength equation of concrete by penetration test. There are not only few estimate strength equations of concrete, but also many problems to apply them because of time, cost, easiness, structural damage, reliability and so on. In this study, there performed a series of test for one year and estimated strength equation of concrete as follows; Linear: fck =3.38d - 95.1 ($$r^2$$=88.6%) Quadratic: fck =0.188$$d^2$$- 10.76d + 166.3 ($$r^2$$=96.7%) here, fck : estimated compressive strength of concrete by Mpa d: exposed probe length by mm.

  • PDF

CONDUCTIVITIES OF SEA-BOTTOM SEDIMENTS

  • HoWoongShon
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.2
    • /
    • pp.79-87
    • /
    • 2003
  • An in-situ four-electrode contact resistivity probe system was designed, and field-tested in submarine sediments. Seismic survey was also performed to support and compare the results of electric survey. The probe was designed to be driven to selected depths below the seafloor using a Vibracore system. The four insulated electrodes were, spaced equidistant across the wedge, were extended beyond the probe tip to minimize effects of sediment disturbance by the wedge insertion. In-situ measurements of resistivity were recorded on board by precision electronic equipment consisting of signal generators and processors, and by temperature- monitoring systems. Overall limits of uncertainty at respective depths below the seafloor are up to ±10% of the measured values. Best estimates of conductivity are considered to be ±3 percent of the reported values. Resistivity measurements were made at six sites in carbonate sediments to a maximum depth of penetration of about 5 m. Average values of conductivity range between 0.88 and 1.21 mho/m. The results show the seabed is composed of alternating layers of relatively high-conductivity material (0.8 to 1.4 mho/m) in thicknesses of more or less one meter and layers about 30 cm thick having relatively low conductivities (0.4 to 0.8 mho/m).

  • PDF