• 제목/요약/키워드: probe image

검색결과 211건 처리시간 0.034초

OCT용 손잡이 형 프로브를 이용한 고막 상태 평가 (Handheld OCT probe for Evaluation of Tympanic Membrane Status)

  • 권형일;김이혁;조남현;정효상;김지현;이상흔
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권4호
    • /
    • pp.285-288
    • /
    • 2011
  • In this study, we developed an optical coherence tomography(OCT) using a sweep-source laser whose center wavelength is 1310 nm and a probe of hand-held type. The developed hand-held probe targets to diagnose the middle ear, so it is miniaturized for ease and convenience of control. For the first time, we performed in-vivo clinical experiments on tympanic membrane(TM) perforation patients not reported from previous studies about OCT. The high-resolution sectional images of tympanic membrane perforation can be obtained. There aren't many studies about diagnostic instrument of the middle ear and diagnosis with sectional image of the middle ear, so the developed OCT system and hand-held probe are applicable to tympanic membrane perforation and other pathologic diagnosis in the middle ear.

주사 전자 현미경에서 영상 획득에 필요한 구성 요소 구현 (Realization for Each Element for capturing image in Scanning Electron Microscopy)

  • 임선종;이찬홍
    • 한국레이저가공학회지
    • /
    • 제12권2호
    • /
    • pp.26-30
    • /
    • 2009
  • Scanning Electron Microscopy (SEM) includes high voltage generator, electron gun, column, secondary electron detector, scan coil system and image grabber. Column includes electron lenses (condenser lens and objective lens). Condenser lens generates fringe field, makes focal length and control spot size. Focal length represents property of lens. Objective lens control focus. Most of the electrons emitted from the filament, are captured by the anode. The portion of the electron current that leaves the gun through the hole in the anode is called the beam current. Electron beam probe is called the focused beam on the specimen. Because of the lens and aperture, the probe current becomes smaller than the beam current. It generate various signals(backscattered electron, secondary electron) in an interaction with the specimen atoms. In this paper, we describe the result of research to develop the core elements for low-resolution SEM.

  • PDF

A Study on the Characteristics of Two-Phase Flow by Driven Bubbles in a Liquid Bath

  • Oh, Yool-Kwon;Seo, Dong-Pyo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권1호
    • /
    • pp.44-50
    • /
    • 2005
  • In the present study, the characteristics of upward bubble flow were experimentally investigated in a liquid bath. An electro-conductivity probe was used to measure local volume fraction and bubble frequency. Since the gas was concentrated at the near the nozzle, the flow parameters were high near the nozzle. In general their axial and radial values tended to decrease with increasing distance. For visualization of flow characteristics, a Particle Image Velocimetry (PIV) and a thermo-vision camera were used in the present study. The experimental results showed that heat transfer from bubble surface to water was largely completed within z = 10 mm from the nozzle, and then the temperature of bubble surface reached that of water rapidly. Due to the centrifugal force, the flow was more developed near the wall than at bubble-water plume. Vortex flow in the bottom region was relatively weaker than that in the upper region.

Affine Local Descriptors for Viewpoint Invariant Face Recognition

  • Gao, Yongbin;Lee, Hyo Jong
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2014년도 춘계학술발표대회
    • /
    • pp.781-784
    • /
    • 2014
  • Face recognition under controlled settings, such as limited viewpoint and illumination change, can achieve good performance nowadays. However, real world application for face recognition is still challenging. In this paper, we use Affine SIFT to detect affine invariant local descriptors for face recognition under large viewpoint change. Affine SIFT is an extension of SIFT algorithm. SIFT algorithm is scale and rotation invariant, which is powerful for small viewpoint changes in face recognition, but it fails when large viewpoint change exists. In our scheme, Affine SIFT is used for both gallery face and probe face, which generates a series of different viewpoints using affine transformation. Therefore, Affine SIFT allows viewpoint difference between gallery face and probe face. Experiment results show our framework achieves better recognition accuracy than SIFT algorithm on FERET database.

Inter-Rater Reliability of Abdominal Muscles Thickness Using Ultrasonography for Different Probe Locations and Thickness Measurement Techniques

  • Lim, One-Bin;Hong, Ji-A;Yi, Chung-Hwi;Cynn, Heon-Seock;Jung, Doh-Heon;Park, Il-Woo
    • 한국전문물리치료학회지
    • /
    • 제18권4호
    • /
    • pp.60-67
    • /
    • 2011
  • Ultrasonography (US) is a recent technique that has proven to be useful for assessing muscle thickness and guiding the rehabilitation decision-making of clinicians and researchers. The purpose of this study was to determine the inter-rater reliability of the US measurement of transversus abdominis (TrA), internal oblique (IO), and external oblique (EO) thicknesses for different probe locations and measurement techniques. Twenty healthy volunteers were recruited in this study. Muscle thicknesses of the transversus TrA, IO, and EO were measured three times in the hook-lying position. The three different probe locations were as follows: 1) Probe location 1 (PL1) was below the rib cage in direct vertical alignment with the anterior superior iliac spine (ASIS). 2) Probe location 2 (PL2) was halfway between the ASIS and the ribcage along the mid-axillary line. 3) Probe location 3 (PL3) was halfway between the iliac crest and the inferior angle of the rib cage, with adjustment to ensure the medial edge of the TrA. The two different techniques of thickness measurement from the captured images were as follows: 1) Muscle thickness was measured in the middle of the muscle belly, which was centered within the captured image (technique A; TA). 2) Muscle thickness was measured along a horizontal reference line located 2 cm apart from the medial edge of the TrA in the captured image (technique B; TB). The intraclass correlation coefficient (ICC [3,k]) was used to calculate the inter-rater reliability of the thickness measurement of TrA, IO and EO using the values from both the first and second examiner. In all three muscles, moderate to excellent reliability was found for all conditions (probe locations and measurement techniques) (ICC=.70~.97). In the PL1-TA condition, inter-rater reliability in the three muscle thicknesses was good to excellent (ICC=.85~.96). The reliability of all measurement conditions was excellent in IO (ICC=.95~.97). Therefore, the findings of this study suggest that TA can be applied to PL1 by clinicians and researchers in order to measure the thickness of abdominal muscles.

HPV DNA 칩의 영상처리 알고리즘 구현 (Implementation of the Image Processing Algorithm for HPV DNA chip)

  • 김종대;연석희;이용업;김종원
    • 한국통신학회논문지
    • /
    • 제28권8C호
    • /
    • pp.803-810
    • /
    • 2003
  • 본 논문은 여성 자궁경부암의 원인이 되는 인두유종 바이러스(papillomavirus)를 진단하기 위한 HPY-DNA 칩의 영상으로부터 탐촉자(probe)의 위치를 찾아내고 각 탐촉자에서의 교잡반응(hybridization) 여부를 결정하기 위한영상리 방법의 구현에 관한 것이다. HPV-DNA 칩은 22종의 HPV를 알아내기 위한 탐촉자들과 환자 샘플과 항상 반응하는 마커들로 구성되어 있다. 침 영상에서 탐촉자 들의 위치는 마커와 상대적으로 고정되어 있어서 도터(dotter)와 스캐너(scanner)의 정밀도에 따른 오차만을 갖는다. 한편 각 탐촉자는 진단신뢰도를 높이기 위하여 4번 씩 인쇄된다. 본 논문은 마커들간의 상대거리와 탐촉자의 중복 인쇄라는 사전정보를 템플릿 정합방법과 결합하여 안정적으로 마커를 찾고, 교잡반응 여부를 정확히 분류하는 방법을 제시한다. 정규화된 상관도를 정합도(matching measure)로 채택하여, 마커들의 상대적 위치에 대하여 평균을 취하면 안정적으로 마커를 찾을 수 있다는 것을 실험을 통하여 보인다. 또한 이미 계산된 정합도를 특징(feature) 값으로 사용하여 4개의 중복 탐촉자에 대한 평균 특징 값을 분류(classification)하면 탐촉자의 교잡반응 여부를 정확히 알아낼 수 있다는 실험 결과를 보인다.

Scanning Probe Microscopy를 이용한 고해 효과 연구 (Study of Refining Effects on Pulp Fibre by Scanning Probe Microscopy(SPM))

  • 김철환;;안경구
    • 펄프종이기술
    • /
    • 제30권4호
    • /
    • pp.49-58
    • /
    • 1998
  • The SPM could image the most detailed microstructure of a sample in a wet and dry state by measuring the interaction between the atoms on the sample surface and the extremely sharp probe tip. The refined fibre exhibited large wrinkles formed by fibrillar bundles, the disintegrated fibres extensively showed “scale-like features”. By using the Non-Contact Atomic Force Microscopy (NC-AFM) and Contact Atomic Force Microscopy (C-AFM) including Phase Detection Microscopy (PDM) and Force Modulation Microscopy (FMM), it was possible to investigate surface topography, surface roughness and mechanical property (hardness or visco-elasticity) of fibre surface in detail. The PDM and FMM images showed that the disintegrated only fibre displayed uniform mechanical properties, whereas the refined one did not. The surface roughness of pulp fibres was higher in refined fibres than in disintegrated fibres due to the presence of external fibrils. These SPM images would be used to provide visual evidence of morphological change of a single fibre created during mechanical treatments such as refining, drying, calendering and so on.

  • PDF

비젼프로브를 이용한 CRT 전자총의 자동치수 검사 (Automatic Inspection of Assembly Tolerances of Cathod Ray Electron Guns by Vision Probe)

  • Park, H.G.;Park, M.C.;Kim, S.W.
    • 한국정밀공학회지
    • /
    • 제14권10호
    • /
    • pp.28-34
    • /
    • 1997
  • This paper describes an automatic measurement method for the in-line inspection of assembly tolerances of cathod ray electron guns. The method uses an optical microscope with a CCD camera as a probe. An automatic gap recognition algorthm with digital image processing and a new software autofocus algorithm based on using an optimal edge detector have been developed to improve the measuring accuracy. An inspection system has been proposed and practically implemented for in-line inspection to a real factory automation line. The inspection system consists of a gap inspection part and an eyelet. Total time consumed for inspecting all measuring items is about 10 seconds and the repeatability is below .+-. 5 .mu. m

  • PDF

나노 사이즈 광프로브에 의한 에버네슨트파의 측정 (Measurements of Evanescent Wave using a Mano-size Optical Probe)

  • 최영규
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권1호
    • /
    • pp.30-35
    • /
    • 2004
  • We have carried out a basic experiment in order to develope a super high-resolution optical microscope which transcend the limitation of diffraction and the wavelength of lightwave. The image of this scope is composed by measuring the evanescent wave which is localized on the surface of the testing materials. A detecting probe was fabricated with a single mode optical fiber to be sharpened by the chemical etching, and drived by PZT. The standing wave of $0.33\mu\textrm{m}$ wavelength evanescent wave which was generated from the $0.78\mu\textrm{m}$-wavelength semiconductor laser was detected by the $0.5\mu\textrm{m}$-thickness optical fiber probe.

부분 반사 프로브를 사용한 공통경로 OCT 이미지 획득 (Common-path OCT Image Using Partial Reflecting Probe)

  • 박재석;정명영;김창석
    • 한국광학회지
    • /
    • 제19권2호
    • /
    • pp.103-107
    • /
    • 2008
  • 기존 OCT 시스템의 Michelson 간섭계와 다르게 간섭신호가 프로브 끝단에서 유도되어 기준신호와 샘플신호가 동일한 경로를 통해 진행하는 공통경로 OCT 시스템을 제작하였다. 최적의 기준신호가 생성되도록 하기 위해 부분반사 프로브(Probe)의 굴절률을 최적화하였고 생체 샘플의 이미지 획득이 가능하도록 프로브의 끝단에서 초점이 맺히도록 볼록 렌즈형 프로브를 제작하였다. 이를 통해서 실제 샘플의 2차원 이미지의 획득이 가능하였다.