• 제목/요약/키워드: probe image

검색결과 211건 처리시간 0.022초

골밀도 측정을 위한 초음파 영상 개선에 관한 연구 (Study on enhancing the ultrasonic image for bone densitometry)

  • 신정식;안중환;김형준;김화영;한승무
    • 한국정밀공학회지
    • /
    • 제22권8호
    • /
    • pp.182-191
    • /
    • 2005
  • It is very important to obtain a high quality of bone image for an accurate ultrasonic measurement of bone mineral density. In this study, we suggested a technique to acquire an optimal image by adapting an acoustic lens and a properly selected ultrasonic probe. Also, we have applied an image processing algorithm with which automatically makes a decision of brightness and contrast of image by generating threshold level, a composition of ultrasonic data, an elimination of noise using modified median filter, and a real time interpolation. We could confirm much improved resolution of bone image with acoustic lens attached to the ultrasonic probe and with the image processing algorithm suggested in this study. Therefore, it became possible to precisely diagnose the osteoprosis using ultrasonic imaging technique.

Coated conductor에서 magneto-optical image와 scanning hall probe를 이용한 flux profile의 측정 및 분석 (Measurement and Analysis of the Flux Profiles of the Coated Conductors using Magneto-optical Image and Scanning Hall Probe)

  • 이효연;곽기성;이준규;유재은;염도준
    • Progress in Superconductivity
    • /
    • 제11권2호
    • /
    • pp.128-134
    • /
    • 2010
  • The magnetic flux profiles in SmBCO and YBCO coated conductors(CC) in the presence of the external field were comparatively investigated by magneto-optic image and scanning hall probe measurements. The current distributions calculated by using the inversion method from measured field profiles show that the decrease of current densities near the edges of SmBCO CC is more significant than those of YBCO CC. Through the comparison of the numerical analysis based on Kim's critical state model and the Brandt and Indenbom's solution, we found that this feature is related to their different field dependant properties of the critical current densities.

초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가 (Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging)

  • 민정환;정회원;강혜경
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권1호
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.

피부전류량의 화상중첩에 의한 경혈의 시각화 (Visualization of Acupoint by Image Overlapping of Skin Current)

  • 이용흠;김용진;고수복;정동명
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.563-566
    • /
    • 1999
  • The functional diagnosis instrument should be preceded first to both the accurate selection of exact acupoint and discrimination. so the measuring and stimulating method are improved to SPAC pattern to evaluate impedance existed in the body. As a result, the resistance factor between skin and probe, the dipolization of cell was reduced so that the judgement of acupoint is advanced. After extraction of optimization parameter of SPAC pattern which the high discrimination efficiency and the lowest affection on the human body is controlled by using microprocessor to enhance conviction. The discrimination efficiency was confirmed by meridian visualization system. Also mechanism of probe was improved to increase efficiency of image recognition processing. The image of discriminated acupoint with probe is obtained by using a camera, the location on the tip of probe is recognized and processed. And then these are converted to virtual color by proportional to measuring current level of scan point on skin.

  • PDF

CMOS 표준 공정을 통한 SPM 프로브의 제작 및 그 성능 평가 (Fabrication of the FET-based SPM probe by CMOS standard process and its performance evaluation)

  • 이훈택;김준수;신금재;문원규
    • 센서학회지
    • /
    • 제30권4호
    • /
    • pp.236-242
    • /
    • 2021
  • In this paper, we report the fabrication of the tip-on-gate of a field-effect-transistor (ToGoFET) probe using a standard complementary metal-oxide-semiconductor (CMOS) process and the performance evaluation of the fabricated probe. After the CMOS process, I-V characteristic measurement was performed on the reference MOSFET. We confirmed that the ToGoFET probe could be operated at a gate voltage of 0 V due to channel ion implantation. The transconductance at the operating point (Vg = 0 V, Vd = 2 V) was 360 ㎂/V. After the fabrication process was completed, calibration was performed using a pure metal sample. For sensitivity calibration, the relationship between the input voltage of the sample and the output current of the probe was determined and the result was consistent with the measurement result of the reference MOSFET. An oxide sample measurement was performed as an example of an application of the new ToGoFET probe. According to the measurement, the ToGoFET probe could spatially resolve a hundred nanometers with a height of a few nanometers in both the topographic image and the ToGoFET image.

초음파유도 난포란 채취를 위한 기본 기술의 개발 I. 초음파상에 나타난 한우 난소, 난포 및 황체의 크기 측정 (Development of Basic Techniques for Ultrasound-guided Follicular Aspiration I. Measurement of Size of Ovaries, Follicles and Corpora Lutea of Korean Native Cows by Ultrasonography)

  • 최민철;강태영;조성근;최상용;손우진;이효종
    • 한국수정란이식학회지
    • /
    • 제12권2호
    • /
    • pp.203-209
    • /
    • 1997
  • This study was carried out to compare the actual size(length and height) of ovaries, follicles and corpora lutea of Korean native cow with those on sonograms. We used 3 different probes(3.5 MHz abdominal probe, 6.5 MHz transvaginal probe and 5.0 MHz transrectal probe) and a calipher for measurements of ovaries, follicles and corpora lutea on sonograms and actual size. Under water immersion, 157 ovaries were scanned with 3 probes and measured in actual size and compared each other. The average height and width of ovaries of Korean native cows were 17.40$\pm$3.99 and 34.23$\pm$6.02mm, respectively. In comparison of height, length of ovaries and preovulation follicles, we found that image with a transvaginal probe was nearly the same as the actual size(p<0.01), but with an abdominal probe the image was appeared larger than the actual size. In measurement(diameter) of preovulation follicles the transvaginal probe was proven to be more accurate to the actual size than other probes and in corpus luteum measurement all probes were accurate. In the comparison of number of follicles by different size ranges, there was no statistical difference in the count of follicles over 10 mm in diameter between the transvaginal probe and naked eyes.

  • PDF

감마선 분포 측정을 위한 섬광필름 기반의 감마 영상 검출기 제작 및 성능평가 (Fabrication and Performance Evaluation of a Scintillating Film-based Gamma Imaging Detector to Measure Gamma-ray Distribution)

  • 신상훈;유욱재;장경원;조승현;이봉수
    • 센서학회지
    • /
    • 제24권3호
    • /
    • pp.202-207
    • /
    • 2015
  • As a feasibility study on development of a gamma imaging probe, we developed a scintillating film-based gamma imaging detector that can obtain scintillation images with information of gamma-ray distribution. The scintillating film-based gamma imaging detector was composed of a sensing probe, an image intensifier, and a beam profiler. To detect and transmit scintillation image, the sensing probe was fabricated by coupling a scintillating film, a fiber-optic image conduit, and a fiber-optic taper, consecutively. First, the optical images of USAF 1951 resolution target were obtained and then, modulation transfer function values were calculated to test the image quality of the sensing probe. Second, we measured the scintillation images according to the activity of the 137Cs and the distance between the surface of 137Cs and the distal-end of sensing probe. Finally, the intensities of scintillating light as functions of the activity and the distance were evaluated from the region of interest in the scintillation image. From the results of this study, it is expected that a fiber-optic gamma imaging detector can be developed to detect gamma-rays emitted from radiopharmaceuticals during radioimmunoguided surgery.

조직등가팬텀을 이용한 임상초음파 영상의 질에 관한 연구 - 제주도 내 병원을 중심으로 - (A Study on the Quality of Image of Ultrasound Using the Tissue-mimicking Phantom - in some hospitals jeju province)

  • 양정화;이경성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권2호
    • /
    • pp.63-69
    • /
    • 2006
  • 초음파 영상의 질은 진단에 많은 영향을 끼친다. 양질의 영상이 항상 일정하게 유지되기 위해서는 QA(Quality Assurance) 프로그램을 가지고 주기적인 관리가 이루어져야 할 것이다. 본 논문은 임상에서의 QA 상황을 파악하는 첫 번째 단계로 실제 병원의 초음파 영상의 질을 살펴보고자 하였다. 이를 위해 인간의 생체등가물질로 된 팬텀을 이용하여 정상 환자를 스캔할 때와 같은 기준 값에서 가상의 낭포 및 고반사 신호의 구조물들이 몇 개가 보이는지 convex probe와 linear probe를 측정하여 비교하였다. convex probe에서는 정상 간과 비슷한 0.5 dB에서 vertical group, cystic masses, high contrast masses에서는 대부분 잘 보였으며 지방간과 비슷한 조건인 0.7 dB에서는 vertical group이 중간레벨에서, cystic masses와 high contrast masses에서는 대체로 모두 잘 보였다. linear probe에서의 vertical group은 0.5 dB에서 중간레벨만 잘 보였고 cystic masses와 high contrast masses는 두 개에서 네 개 보이는 것들이 고루 분포되었으나 하나도 보이는 않는 경우가 11건수나 되었다. 0.7 dB에서는 vertical group이 6개 이하가 보이는 것이 대부분 이었고 cystic masses와 high contrast masses에서도 두개에서 네 개 보이는 것들이 고루 분포되었고 하나도 보이는 않는 경우도 40건 있었다. 이로서 지방간과 같은 조건하에서는 linear probe의 영상의 질이 대체로 좋지 않으므로 기준 설정 및 물리적인 조건들을 검사 시에 잘 조정하거나 probe의 교체가 필요하다고 판단된다. 많은 병원에서 초음파 장비를 잘 관리하고 있다고 하지만, 영상의 질은 아직도 미흡한 것을 알 수 있다. 초음파 장비의 설치에서부터 영상의 질을 평가하고 지속적이고 정기적인 관리와 평가가 이루어질 수 있는 프로그램이 필요하겠다.

  • PDF

초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구 (A Study on the Reflectivity according to the Material of Biopsy Gun Needle Used in Ultrasound Biopsy)

  • 김훈;임청환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권2호
    • /
    • pp.97-105
    • /
    • 2024
  • The examination needle used in ultrasound biopsy is a medical device used to determine whether there is an abnormality in the tissue. Typically, stainless steel is the standard material used for such needles; however, this study wanted to identify a material that could better enhance sound compared to traditional stainless steel. In this study, six types of needle materials available with the biopsy gun were inserted into pork and ultrasound images according to the curved probe and linear probe were evaluated using ultrasound equipment. The findings revealed significant improvements in ultrasound acoustic enhancement with alternative materials compared to stainless steel (p<0.05). The results regarding the depth of each ultrasound image using the curved probe showed that tungsten and brass had high sound enhancement(p<0.05), while with the linear probe, sound enhancement was high in brass, pla, aluminum, and copper(p<0.05). Due to these results, the previously used stainless needle showed lower ultrasound acoustic enhancement than the five types of materials being compared. Consequently, the outcomes of this study provide valuable insights for the development of new needle technologies aimed at minimizing patient risks and improving diagnostic accuracy.

화학적 식각을 이용한 근접장 주사 현미경용 탐침의 제작 (Fabrication of Near-field Scanning Optical Microscope(NSOM) Probe by Chemical Etching)

  • 김성철;이혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.555-557
    • /
    • 1995
  • In near field optics, optical fiber probe is smaller than the wavelength of light. This small probe makes it possible to overcome the diffraction limit due to wave property of light. In conventional optical systems, the image resolution is governed by wavelength. But in NSOM, it is determined by probe tip size and probe shape. Therefore probe tip size and shape are very important points in near field optics. In this paper, we will suggest the new fabrication methods of optical fiber probe and show that the probe tip size is sub-micrometer using SEM.

  • PDF