• Title/Summary/Keyword: probe image

Search Result 211, Processing Time 0.02 seconds

A Study on Construction of Automatic Inspection System for Welding Flaws (용접결함 검사 자동화 시스템 구축에 관한 연구)

  • Kim, Chang-Hyun;Yu, Hong-Yeon;Hong, Sung-Hoon;Kim, Jae-Yeol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.6
    • /
    • pp.37-42
    • /
    • 2007
  • The purpose of this research is stability estimation of plant structure through classification and recognition about welding flaw in SWP(Spiral Welding Pipe). And, In this research, we used nondestructive test based on ultrasonic test as inspection method, and made up 2-axes inspection robot in order to control of ultrasonic probe on the SWP surface, and programmed to image processing and probabilistic neural network(PNN) classifying code by MATLAB programming. Through this process, we proved efficiency on the system of SWP stability Estimation.

A Road Database Update Method for Vehicle Routing Using GPS Cellular Phone (GPS 휴대폰을 이용한 차량경로용 도로망 데이터베이스 수정 방안)

  • Jang, Young-Kwan
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.5
    • /
    • pp.97-101
    • /
    • 2007
  • As the use of vehicle route application and LBS(location based service) are fast grew, the importance of maintaining road network data is also increased. To maintain road data accuracy, we can collect road data by driving real roads with probe vehicle, or using digital image processing for the extraction of roads from aerial imagery. After compare the new road data to current database, we can update the road database, but that job is mostly time and money consuming or can be inaccurate. In this paper, an updating method of using GPS(global positioning system) enabled cell phone is proposed. By using GPS phone, we can update road database easily and sufficiently accurately.

Ultra-precision Positioning By Using Coherence of White Light (백색광의 제한 간섭성을 이용한 초정밀 위치결정)

  • Park, Hyun-Goo;Kang, Min-Gu;Kim, Seung-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.6
    • /
    • pp.995-1001
    • /
    • 1997
  • In this paper, a new positioning method with incoherence of white light is described and practically implemented to attach VCR heads on a drum very accurately. This method utilizes the Michelson Interferometer which uses white light with short coherence length as the light source to generate interference fringes only in case the optical path difference is shorter than about 2.mu.m. The course position of VCR heads and the fine are determined by appearance and visibility of interference fringes, respectively. The appearance are detected by an image processing technique using FFT(Fast Fourier Transform).

Review of Photoacoustic Imaging for Imaging-Guided Spinal Surgery

  • Han, Seung Hee
    • Neurospine
    • /
    • v.15 no.4
    • /
    • pp.306-322
    • /
    • 2018
  • This review introduces the current technique of photoacoustic imaging as it is applied in imaging-guided surgery (IGS), which provides the surgeon with image visualization and analysis capabilities during surgery. Numerous imaging techniques have been developed to help surgeons perform complex operations more safely and quickly. Although surgeons typically use these kinds of images to visualize targets hidden by bone and other tissues, it is nonetheless more difficult to perform surgery with static reference images (e.g., computed tomography scans and magnetic resonance images) of internal structures. Photoacoustic imaging could enable real-time visualization of regions of interest during surgery. Several researchers have shown that photoacoustic imaging has potential for the noninvasive diagnosis of various types of tissues, including bone. Previous studies of the surgical application of photoacoustic imaging have focused on cancer surgery, but photoacoustic imaging has also recently attracted interest for spinal surgery, because it could be useful for avoiding pedicle breaches and for choosing an appropriate starting point before drilling or pedicle probe insertion. This review describes the current instruments and clinical applications of photoacoustic imaging. Its primary objective is to provide a comprehensive overview of photoacoustic IGS in spinal surgery.

Comparison of Ultrasonography and Video-otoscopy for the Evaluation of the Tympanic Membrane in Otitis Dogs (외이염 발생견에서 고막평가를 위한 초음파 및 이경 검사법 비교)

  • Lee Jong-won;Eom Ki-dong;Seong Yun-sang;Lee Hae-oon;Moon Kum-jung;Bae Sun-hee;Byun Tae-Kyung;Song Gyoung-ho;Jeon Jong-hoon;Jang Kwang-ho;Oh Tae-ho;Lee Keun-woo
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.382-385
    • /
    • 2005
  • The aim of this study was to compare ultrasonography with video-otoscopy for the evalution of the external ear canal and the tympanum. Fifty dogs with clinical signs ot the bilateral ear diseases were examined using otoscopy under general anesthesia. Ultrasonographic examination was performed with an 11 MHz linear-arrary probe and a 6.5MHz convex probe, with the external ear canal filled with saline. Saline functioned as a contrast media and enhanced image quality of ultrasonography. The images of 100 ears before and after the ear cleansing were obtained at otoscopy and ultrasonography. On the video-otoscopic images, the tympanic membrane was identified in 59 ears before the ear cleansing and 91 ears after cleansing. On the ultrasonography, the tympanic membrane was detected in 98 ears before the ear cleansing and in all ears after cleansing. With these results, it was concluded that ultrasonography with infusing saline into the ear canal, could be a useful diagnostic procedure to identify the tympanic membrane in otitis dogs.

129 GHz SIS MIXER RECEIVER FOR KOREAN VLBI NETWORK (한국우주전파관측망 129 GHz 초전도 믹서 수신기)

  • Lee, Jung-Won;Wang, Ming-Jye;Li, Chao-Te;Chen, Tse-Jun;Kim, Soo-Yeon;Lu, Wei-Chun;Kang, Yong-Woo;Shi, Sheng-Cai;Han, Seog-Tae
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.3
    • /
    • pp.71-80
    • /
    • 2012
  • We have developed superconducting mixer receivers for 129 GHz VLBI observation in Korean VLBI Network (KVN). The developed mixer has a radial waveguide probe with simple transmission line L-C transformer as a tuning circuit to its 5 series-connected junctions, which can have 125 - 165 GHz as the operation radio frequency (RF). For intermediate frequency (IF) signal path a high impedance quarter-wavelength line connects the probe to one end of symmetric RF chokes. The double side band (DSB) receiver noise of the mixer was about 40 K over 4 - 6 GHz IF band, whereas we achieved the uncorrected single side band (SSB) noise temperature of about 70 K and better than 10 dB image rejection ratio in 2SB configuration with 8 - 10 GHz IF band. Insert-type receiver cartridges employing the mixers have been under commission for KVN stations.

Photochemical Modulation of Bragg-Reflection Wavelengths in Cholesteric Liquid Crystals Containing a Chiral Azobenzene

  • Lee, Hyoung-Kwan;Goo, Chul-Whoi;Tomiki Ikeda
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.18 no.2
    • /
    • pp.41-54
    • /
    • 2000
  • Photochemical modulation of Bragg-reflection wavelengths based on isomerization of an azobenzene (Azo) and subsequent change in reflectance was investigated in cholesteric liquid crystals (ChLCs) which reflect light in visible wavelength region. Irradiation at 366 nm, which causes an efficient transcis isomerization of Azo, led to change in reflected color of ChLCs toward shorter wavelengths with a concomitant lowering of phase transition. Reversible change in color was induced all-optically by alternate irradiation at effective wavelengths for reversible isomerization of Azo. A considerable variation in reflectance was also observed when the photoinduced change in color was measured by a probe light with the same handedness as the ChLCs. The spectral Position of selective light reflection in the initial states played an important role to produce a normal-mode and a reverse-mode switching in photoinduced modulation of reflectance of the ChLCs with respect to the probe light.

  • PDF

Feasibility study on the development of Liquid crystal-optical fiber temperature sensor for minimal invasive laserthermia (LC(Liquid crystal)-광섬유를 이용한 최소 침습적 레이저 온열 치료용 온도 측정 센서의 개발을 위한 기초 연구)

  • Lee, Bong-Soo;Hwang, Young-Muk;Chung, Soon-Cheol
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.225-230
    • /
    • 2003
  • Nowadays, laserthermia is widely used to treat malignant tumors with generating heat as the one of minimal invasive surgeries. Generally, the laserthermia probe system consists of the fiber-optic laser and light guides, image guide and temperature sensor. It is very important to measure the temperature of treating tumor and make a stable temperature ($42{\sim}43^{\circ}C$) during the treating time. Therefore, laserthermia probe needs temperature sensor which can measure it exactly and fast. In this study, to develop a new type of temperature sensor with LC(liquid crystal) and optical fiber, the reflectivity of LC according to the temperature changes are measured. Also, the relationships are derived from the results.

MRI-Induced Full Thickness Burn on the Ear Lobule due to Pulse Oximetry: A Case Report (증례보고: MRI 검사시 귓불에 부착한 산소측정기로 인해 발생한 전층 화상)

  • Kim, BumSik;Lim, SooA;Yoon, JungSoo;Eo, SuRak;Han, Yea Sik
    • Journal of the Korean Burn Society
    • /
    • v.24 no.2
    • /
    • pp.43-45
    • /
    • 2021
  • Magnetic Resonance Image (MRI) has been used as a safe, conventional and harmless diagnostic tool. However, thermal injuries have frequently been reported during MRI scanning due to the heat generated by the reaction with the magnetic field. It is recommended that metal-containing monitoring devices such as pulse oximetry and ECG monitoring leads should be removed prior to the start of the MRI scan, but these monitoring devices are inevitably placed in children or patients in the intensive care unit who have low compliance with the scan. Since the interaction between the metal probe or wire loop of pulse oximetry and the magnetic field can result in high thermal conduction, full-thickness burn can occur over the entire body surface during the MRI examination. Several cases of thermal burns from pulse oximetry on the fingers have been reported. However, we present a case of a full-thickness burn arising left earlobe in a 2-month-old child caused by the high conduction heat from pulse oximetry metal probe.

Face Recognitions Using Centroid Shift and Neural Network-based Principal Component Analysis (중심이동과 신경망 기반 주요성분분석을 이용한 얼굴인식)

  • Cho Yong-Hyun
    • The KIPS Transactions:PartB
    • /
    • v.12B no.6 s.102
    • /
    • pp.715-720
    • /
    • 2005
  • This paper presents a hybrid recognition method of first moment of face image and principal component analysis(PCA). First moment is applied to reduce the dimension by shifting to the centroid of image, which is to exclude the needless backgrounds in the face recognitions. PCA is implemented by single layer neural network which has a teaming rule of Foldiak algorithm. It has been used as an alternative method for numerical PCA. PCA is to derive an orthonormal basis which directly leads to dimensionality reduction and possibly to feature extraction of face image. The proposed method has been applied to the problems for recognizing the 48 face images(12 Persons $\ast$ 4 scenes) of 64$\ast$64 pixels. The 3 distances such as city-block, Euclidean, negative angle are used as measures when match the probe images to the nearest gallery images. The experimental results show that the proposed method has a superior recognition performances(speed, rate). The negative angle has been relatively achieved more an accurate similarity than city-block or Euclidean.