• Title/Summary/Keyword: probe h

Search Result 725, Processing Time 0.033 seconds

Development of a Micro pH-ISFET Probe for in vivo Measurements of the Ion Concentration in Blood (생체내의 혈중이온농도 예측을 위한 마이크로 pH-ISFET프로브의 개발)

  • Sohn, Byung-Ki;Lee, Jong Hyun;Lee, Kwang Man
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.1
    • /
    • pp.83-90
    • /
    • 1986
  • A micro pH-ISFET probe, which can be applied to the in vivo measurements of the hydrogen ion concentration in blood, has been developed, and a measuring system equiped with this probe also developed. The pH-ISFET has been fatricated by employing the techniques of integrated circuit fabrication. Two kinds of micro electrode formed around the sensing gate during the wafer process, and the other is a capillary type of Ag/AfCl/sat. KCI reduced in size. This capillary electrode has shown its good performance characteristics so far in the application with ISFET as well as a commercial one. In order to form a micro pH-ISFET probe, this pH-ISFET and well as a commercial one. In order to form a micro pH-ISFET probe, this pH-ISFET and the capillary electrode were built together into a needle tip having 1 mm inner diameter. The chip size of a twin pH-ISFET is 0.8 mmx1.4 mm, the material of the sensing gate membrane is Si3N4, and the sensitivity of the developed probe is about 52mV/pH.

  • PDF

Relationship between Ambulatory 24-hour Double Probe pH Monitoring and Reflux Finding Score in Patients with LPR (인후두 역류환자에서 이동성 24시간 이중 탐침 산도 검사와 인후두 역류 소견 점수와의 상관관계)

  • Park, Young-Dae;Kang, Dae-Woon;Lee, Jin-Choon;Lee, Byung-Joo;Wang, Soo-Geun;Kim, Gwang-Ha
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.19 no.2
    • /
    • pp.136-141
    • /
    • 2008
  • Background and Objectives: Laryngopharyngeal reflux (LPR) is a very common disease among outpatients of department of otorhinolaryngology. Although there are several diagnostic tools for LPR disease and ambulatory 24-hour double-probe pH monitoring is gold standard method, empirical diagnosis by reflux symptom index and reflux finding score (RFS) are mainly used. So we analyzed the relationship between ambulatory 24-hour double-probe pH monitoring and RFS in patients with LPR. Subjective and Method: Fifty patients with LPR symptoms and abnormal RFS and ambulatory 24-hour double probe monitoring were enrolled. Each items and sum of laryngeal reflux score were compared the results of ambulatory 24-hour double-probe pH monitoring in upper (UES) and lower (LES) esophageal sphincter. Results: There were no significant correlation between the results of ambulatory 24-hour double-probe pH monitoring in UES (pH<4 and pH<5) and each item and sum of RFS. However, supine time and reflux number of UES (pH<5) were showed the partial correlations with diffuse laryngeal edema and thick endolaryngeal mucus (p=0.03, p=0.01). Although there were no relationship between the results of ambulatory 24-hour double-probe pH monitoring in LES and sum of RFS, the significant correlations presented between granuloma and total time (p=0.008), upright time (p=0.008, reflux number (p=0.049) of LES. Conclusion: Although granuloma among items of RFS showed significantly correlation with the results of ambulatory 24-hour double-probe pH monitoring in LES, there were no significant correlation between the results of ambulatory 24-hour double-probe pH monitoring in UES and LES and items and sum of RFS.

  • PDF

Study on Validity and Reliablity of the Cutoff Probe and Langmuir Probe via Comparative Experiment in the Processing Plasma

  • Kim, D.W.;You, S.J.;You, K.H.;Lee, J.W.;Kim, J.H.;Chang, H.Y.;Oh, W.Y.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.576-576
    • /
    • 2013
  • Recently, diagnostics of plasma becomes more important due to requirement of precise control of plasma processing based on measurement of plasma characteristics. The Langmuir probe has been used for the diagnostics but it has an inevitable uncertainty and error sources such as incorrect tip length and RF noise. Instead of the Langmuir probe, various diagnostic methods have been developed and researched. The cutoff probe is promising one for plasma density using microwaves and resonance phenomenon at the plasma frequency. The cutoff probe has various advantages as follows; (i) it is simple and robust, (ii) it uses few assumptions, and (iii) it is free from deposition by reactive gas. However, the cutoff probe also has uncertainty and error sources such as gap between tips, tip length, direction of tip plane, and RF noise. In this study, the uncertainty and error sources in manufacturing both probes and in diagnostics process were analyzed via comparative experiment at various discharge conditions. Furthermore, to reveal the user dependence of both probes, three well trained Ph. D students made the Langmuir probe and the cutoff probe, respectively, and it were analyzed. Thought this study, it is established that reliability and validity of the Langmuir probe and the cutoff probe related with not only the intrinsic characteristics of probes but also probe user.

  • PDF

A Study of Testing Method for Diagnostic Ultrasonic Array Probe through Pattern Analysis of Acoustic-Fields with Probe Channel Division (채널별 음장분포 분석을 통한 진단용 초음파 어레이 프로브의 평가방법에 관한 연구)

  • Yoo, B.C.;Choi, H.H.;Noh, S.C.;Min, H.K.;Kwon, J.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.229-236
    • /
    • 2006
  • The acoustic field analysis method is the superior calibration method for rectifying the ultrasonic probe sensitivity. This method also can be applied to evaluate the probe performance in clinical fields without numerical analysis and precise measurements. In this paper, we propose the method of acoustic field pattern analysis with probe channel division for the evaluation of diagnostic ultrasound probe characterization. In order to verify our purpose, we performed a set of experiments. We measured the acoustic-field pattern of the three inferiority probes by channel division to evaluate an acoustic field distribution and impulse response characteristics. By comparing the results of acoustic field measurement method with that of conventional method such as impulse response and live image test for linear array probes, it is demonstrated that the ultrasound field measurement method is more effective then conventional method in detection of defective elements.

The characteristic of the elcetrostatic probe surface heated with current (가열식(加熱式) 정전탐침전극(靜電探針電極)의 표면특성(表面特性))

  • Kwak, Y.S.;Cho, J.S.;Park, C.H.;Kim, K.H.;Kim, S.P.;Kim, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.151-154
    • /
    • 1989
  • In the measurement of plasma parameters of the plasma C.V.D with probe method, the most important problem is the contamination of the probe surface. In this paper, we observe the surface contamination of probe surface with microscope and determine the critical current and the critical time to sustain the clean surface of probe in the plasma C.V.D.

  • PDF

Diagnostics of Theta-Pinch Plasma by Magnetic Probe (자기 탐침에 의한 쎄타 핀치 플라즈마의 진단)

  • Shim, J.H.;Cho, J.H.;Chang, Y.M.;Chung, W.K.;Kang, H.B.
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.401-404
    • /
    • 1989
  • Some magnetic probes for theta-pinch experiment have been constructed. Methods of building the coil, conecting it to the oscilloscope, shielding and enclosing the probe are discribed. Such a probe has been used to measure the magnetic flux penetrating it within theta - pinched plasmas.

  • PDF

Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging (초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가)

  • Jung-Whan, Min;Hoi-Woun, Jeong;Hea-Kyung, Kang
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.

The Relationship Between Esophageal Manometry and 24 Hour Double Prove pH-metry with Gastroesophageal Reflax in Pharyrngeal Neurosis Patients. (인두신경증 환자에서 Esophageal manometry와 24hour double prove pH metry 검사 및 위식도 역류와의 관계)

  • 김선태
    • Korean Journal of Bronchoesophagology
    • /
    • v.2 no.1
    • /
    • pp.88-96
    • /
    • 1996
  • In recently the gastroesophageal reflux disease(GERD) has been known to induce the otolaryngologic manifestations. Pharyngeal neurosis is a disease which we could have not found the cause frequently. So we have studied the relation between the pharyngeal neurosis and the GERD among 50 patients who were diagnosed as pharyngeal neurosis after esophagogram and laryngoscopic examination. We performed esophageal manometry and 24hour double-probe pH-metry and then compared with normal control group(n=30). The results are as follows 1 Among 50 patients, 12(24%) patients were diagnosed as GERD by DeMeester scoring. 2. In esophageal manometry, the upper and lower esophageal sphincter between the patients and the control group have no significant difference(p>0.05) and 9 among 50 pateints showed abnormal peristaltic movement in esophageal body contraction. 3. In 24hour double-probe pH-metry, the esophageal probe showed that in GERD group(n= 12) the number of reflux episode, episodes greater than 5 minutes and the percentage of time

  • PDF