• 제목/요약/키워드: primary structure

검색결과 1,744건 처리시간 0.022초

Seismic response of nonstructural components considering the near-fault pulse-like ground motions

  • Zhai, Chang-Hai;Zheng, Zhi;Li, Shuang;Pan, Xiaolan;Xie, Li-Li
    • Earthquakes and Structures
    • /
    • 제10권5호
    • /
    • pp.1213-1232
    • /
    • 2016
  • This paper investigates the response of nonstructural components in the presence of nonlinear behavior of the primary structure considering the near-fault pulse-like ground motions. A database of 81 near-fault pulse-like ground motions is used to examine the effect of these ground motions on the response of nonstructural components. For comparison, a database of 573 non-pulse-like ground motions selected from the PEER database is also employed. The effects of peak ground velocity (PGV), maximum incremental velocity (MIV), primary structural degrading behavior and damping of nonstructural components are evaluated and discussed statistically. Results are presented in terms of amplification factor which quantifies the effect of inelastic deformations of the primary structure on subsystem responses. The results indicate that the near-fault pulse-like ground motions can significantly increase the amplification factors of nonstructural components with primary structural period and the magnitude of increase can reach 17%. The effect of PGV and MIV on amplification factors tends to increase with the increase of primary structural ductility. The near-fault pulse-like ground motions are more dangerous to components supported by structures with strength and stiffness degrading behavior than ordinary ground motions. A new simplified formulation is proposed for the application of amplification factors for design of nonstructural components for near-fault pulse-like ground motions.

단위농협(單位農協)의 환경변화(環境變化)와 조직(組織)의 발전방안(發展方案) (Impacts of Changing Environments on Primary Agricultural Cooperatives and Redirections for Its Structural Improvement)

  • 권용대
    • 농업과학연구
    • /
    • 제24권1호
    • /
    • pp.108-120
    • /
    • 1997
  • Since domestic and international environments has changed rapidly, Korean primary agricultural coopratives are expected to face many difficulties in business management, especially marketing and banking business. Therefore, it is necessary to reframe the exitsting structure of primary agricultural cooperatives so as to enhance the competitiveness in terms of management efficiency. However, There are many problems to be solved such as overnumbered staffs compared with decreasing number of farming population, unbalanced ratio between executive officials and lower-level officials, complexity of position-ranking system resulting from unclearness of official title and office regulations, and management right excessively concentrated on cooperative leader. The suggested measures for such problems are as follows; 1) attaining the economy size of agricultural cooperaitves in line with decreasing rural community, 2) fostering the on-the job training programs and the personnel administration according to job competency, 3) merging the small primary cooperatives into larger units with efficiency, 4) specializing the cooperative business based on their regional comparative advantage, 5) maintaining the rational adjustment between elected cooperative leader's management right and responsibility.

  • PDF

Full ZVS Load Range Diode Clamped Three-level DC-DC Converter with Secondary Modulation

  • Shi, Yong
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.93-101
    • /
    • 2016
  • A new four-primary-switch diode clamped soft switching three-level DC-DC converter (TLDC) with full zero-voltage switching (ZVS) load range and TL secondary voltage waveform is proposed. The operation principle and characteristics of the presented converter are discussed, and experimental results are consistent with theoretical predictions. The improvements of the proposed converter include a simple and compact primary structure, TL secondary rectified voltage waveform, wide load range ZVS for all primary switches, and full output-regulated range with soft switching operation. The proposed converter also has some disadvantages. The VA rating of the transformer is slightly larger than that of conventional TLDCs in variable input and constant output mode. The conduction loss of the primary coil is slightly higher because an air gap is inserted into the magnetic cores of the transformer. Finally, the secondary circuit is slightly complex.

Primary cilia in energy balance signaling and metabolic disorder

  • Lee, Hankyu;Song, Jieun;Jung, Joo Hyun;Ko, Hyuk Wan
    • BMB Reports
    • /
    • 제48권12호
    • /
    • pp.647-654
    • /
    • 2015
  • Energy homeostasis in our body system is maintained by balancing the intake and expenditure of energy. Excessive accumulation of fat by disrupting the balance system causes overweight and obesity, which are increasingly becoming global health concerns. Understanding the pathogenesis of obesity focused on studying the genes related to familial types of obesity. Recently, a rare human genetic disorder, ciliopathy, links the role for genes regulating structure and function of a cellular organelle, the primary cilium, to metabolic disorder, obesity and type II diabetes. Primary cilia are microtubule based hair-like membranous structures, lacking motility and functions such as sensing the environmental cues, and transducing extracellular signals within the cells. Interestingly, the subclass of ciliopathies, such as Bardet-Biedle and Alström syndrome, manifest obesity and type II diabetes in human and mouse model systems. Moreover, studies on genetic mouse model system indicate that more ciliary genes affect energy homeostasis through multiple regulatory steps such as central and peripheral actions of leptin and insulin. In this review, we discuss the latest findings in primary cilia and metabolic disorders, and propose the possible interaction between primary cilia and the leptin and insulin signal pathways which might enhance our understanding of the unambiguous link of a cell's antenna to obesity and type II diabetes.

1차 측 제어 플라이벅 컨버터의 정전류 및 정전압 제어 (A Constant-Current and Constant-Voltage Control Method for Primary-Side Regulated Fly-Buck Converter)

  • 조영훈;장바울
    • 전력전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.30-38
    • /
    • 2023
  • In this paper, a constant current(CC) and constant voltage(CV) control method using a primary-side regulated(PSR) fly-buck converter is proposed. Because the primary-side structure of the fly-buck converter is the same as that of the synchronous buck converter, it always operates in continuous conduction mode(CCM). Therefore, in the proposed method, the load information on the secondary side can always be easily estimated by measuring the primary inductor current at the midpoint of the switch-on period. An accurate CC/CV control can be achieved through simple calculations based on this estimated information. Consequently, the proposed method is advantageous for optimizing the control performance of the PSR converter. The validity of the proposed control was verified using a 5 W prototype of a PSR fly-buck converter. The experimental results confirmed that the current reference of 500 mA was followed within the error range of 1.2%, and that the voltage reference of 12 V was followed within the error range of 1.8% despite the indirect control of the load current and output voltage from the primary side.

진도견(珍島犬) 정세관상피(精細管上皮)의 정자발생(精子發生)과 미세구조(微細構造) (Spermatogenesis and its fine structure of the seminiferous epithelium in the Jindo dog)

  • 김용환;박영석
    • 대한수의학회지
    • /
    • 제33권1호
    • /
    • pp.23-36
    • /
    • 1993
  • To investigate the cycle and relative frequences and the fine structure of seminiferous epithelia in mature Jindo dogs, histologic study was performed. The results obtained were summarized as follows; 1. Type A spermatogonia appeared approximately 1.6 times as many at stage II as compared to stage I while type In spermatogonia appeared small amount in stage III, IV and V. type B spermatogonia were found during the stage VI to VIII, though not detectable during stage I to V. The type B spermatogonia divided at stage VII to produce the preleptotene primary spermatocytes at stage VIII. The number of primary spermatocytes of the leptotene phase markedly increased during stage I to II, and the primary spermatocytes of the pachytene phase were shown the least in number at stage IV. The secondary spermatocytes could be seen only at stage IV. 2. The relative frequencies of each stage from stages I to VIII of the cycle of seminiferous epithelia were 31.6, 11.9, 10.0, 3.2, 8.2, 10.1, 11.7 and 13.2% respectively. 3. On electron microscopic observations, acrosomal vesicle of spermatids appeared larger though the bulk of germ cells were the morphologically same as those of the other animal species. Thread line structures light microscopically observed in the cytoplasm of Sertoli cell were the longitudinal orientation of mitochondria.

  • PDF

Modulator of surface plasmon polariton based cycle branch graphene waveguide

  • Zhu, Jun;Xu, Zhengjie;Xu, Wenju;Wei, Duqu
    • Carbon letters
    • /
    • 제25권
    • /
    • pp.84-88
    • /
    • 2018
  • At present, an important research area is the search for materials that are compatible with CMOS technology and achieve a satisfactory response rate and modulation efficiency. A strong local field of graphene surface plasmon polariton (SPP) can increase the interaction between light and graphene, reduce device size, and facilitate the integration of materials with CMOS. In this study, we design a new modulator of SPP-based cycle branch graphene waveguide. The structure comprises a primary waveguide of graphene-$LiNbO_3$-graphene, and a secondary cycle branch waveguide is etched on the surface of $LiNbO_3$. Part of the incident light in the primary waveguide enters the secondary waveguide, thus leading to a phase difference with the primary waveguide as reflected at the end of the branch and interaction coupling to enhance output light intensity. Through feature analysis, we discover that the area of the secondary waveguide shows significant localized fields and SPPs. Moreover, the cycle branch graphene waveguide can realize gain compensation, reduce transmission loss, and increase transmission distance. Numerical simulations show that the minimum effective mode field area is about $0.0130{\lambda}^2$, the gain coefficient is about $700cm^{-1}$, and the quality factor can reach 150. The structure can realize the mode field limits of deep subwavelength and achieve a good comprehensive performance.

Experimental study on vibration serviceability of cold-formed thin-walled steel floor

  • Bin Chen;Liang Cao;Faming Lu;Y. Frank Chen
    • Steel and Composite Structures
    • /
    • 제46권4호
    • /
    • pp.577-589
    • /
    • 2023
  • In this study, on-site testing was carried out to investigate the vibration performance of a cold-formed thin-walled steel floor system. Ambient vibration, walking excitation (single and double persons), and impulsive excitation (heel-drop and jumping) were considered to capture the primary vibration parameters (natural frequencies, damping ratios, and mode shapes) and vertical acceleration response. Meanwhile, to discuss the influence of cement fiberboard on structural vibration, the primary vibration parameters were compared between the systems with and without the installation of cement fiberboard. Based on the experimental analysis, the cold-formed thin-walled steel floor possesses high frequency (> 10 Hz) and damping (> 2%); the installed cement fiberboard mainly increases the mass of floor system without effectively increasing the floor stiffness and may reduce the effects of primary vibration parameters on acceleration response; and the human-structure interaction should be considered when analyzing the vibration serviceability. The comparison of the experimental results with those in the AISC Design Guide indicates that the cold-formed thin-walled steel floor exhibits acceptable vibration serviceability. A crest factor 𝛽rp (ratio of peak to root-mean-square accelerations) is proposed to determine the root-mean-square acceleration for convenience.

스마트 구조물용 광섬유 격자센서의 원전격납건물 적용 실험 연구 (Study on the Fiber Bragg Grating Smart Sensors for Containment Structure in Nuclear Power Plant)

  • 김기수;송영철;방기성;윤덕중
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.412-415
    • /
    • 2004
  • This study was performed to verify the behaviors of fiber Bragg grating (FBG) sensors attached to the containment structure in the nuclear power plant as a part of structural integrity test which demonstrates that the structural response of the non-prototype primary containment structure is within predicted limits plus tolerances when pressurized to $115\%$ of containment design pressure, and that the containment does not sustain any structural damage.

  • PDF

Comparison of Confidence Intervals on Variance Component In a Simple Linear Regression Model with Unbalanced Nested Error Structure

  • Park, Dong Joon;Park, Sun-Young;Han, Man-Ho
    • Communications for Statistical Applications and Methods
    • /
    • 제9권2호
    • /
    • pp.459-471
    • /
    • 2002
  • In applications using a linear regression model with nested error structure, one might be interested in making inferences concerning variance components. This article proposes approximate confidence intervals on the variance component of the primary level in a simple linear regression model with an unbalanced nested error structure. The intervals are compared using computer simulation and recommendations are provided for selecting an appropriate interval.