• 제목/요약/키워드: primary phase

검색결과 1,062건 처리시간 0.023초

피스톤 펌핑 위상이 텐덤형 사판식 액셜 피스톤 펌프의 진동, 소음에 미치는 영향에 관한 연구(2) (A Study on Effects of Piston Pumping Phase on Vibration and Noises of Tandem Swash Plate Type Axial Piston Pump(2))

  • 박성환;이진걸
    • 한국정밀공학회지
    • /
    • 제16권12호
    • /
    • pp.31-39
    • /
    • 1999
  • Previous researches and experiments have already verified that the primary noise source of high pressure tandem axial thpe piston pump is fluid-borne noise from the process of oil distribution between the kidney-shaped port and valve plate. So, many researchers have improved pressure gradients and reduced sound levels by applying pre-compression and pre-decompression metering grooves to valve plate. In practice however, the sound level of th high pressure tandem axial type piston pump is still undesirable. This paper testified the effect of pumping phase of the piston on vibration and noise of th high pressure tandem axial type piston pump on the best of theoretical research in $this^(1)$. Therefore considering the pumping phase of the piston when assembling the tandem axial type piston pump, it is possible to reduce 1.5~2[dB]of sound level.

  • PDF

위상이동 방식 Full-Bridge 컨버터의 손실 분석에 관한 연구 (A Study on the Loss Analysis for the Phase-Shaft Full-Bridge Converter)

  • 배진용;김용;백수현;이은영;최근수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.157-162
    • /
    • 2003
  • This paper presents the loss analysis of Phase-Shift Full-Bridge Converter. Full-Bridge DC/DC Converter presented in this paper used a phase shift control in the primary side to achieve ZVS (Zero-Voltage-Switching) for main switch. Phase-Shaft Full-Bridge converter have an effect on the high power system. This paper analyses the loss of each component and the various losses in the circuit assessed. The result of the analysis are verified using 2.5kW, 50kHz prototype.

  • PDF

Nano-scale Shell in Phase Separating Gd-Ti-Al-Co Metallic Glass

  • Chang, Hye Jung;Park, Eun Soo;Kim, Do Hyang
    • Applied Microscopy
    • /
    • 제43권2호
    • /
    • pp.98-101
    • /
    • 2013
  • In the present study, formation of yard and shell has been investigated in as-melt-spun $Gd_{30}Ti_{25}Al_{25}Co_{20}$ alloy using a variety of transmission electron microscopy techniques. The phase separation during cooling leads to the formation of the microstructure consisting of amorphous droplets with different size scales embedded in the amorphous matrix. Due to the interdiffusion at the interface after the first-step phase separation, ~50 nm-thick yard develops on the surface of the primary droplet particle. Due to the critical wetting phenomenon, ~5 nm thickness shell enveloping the droplet forms. The sell is enriched in Co and Ti, implying that the composition is close to that of the droplet.

Cinematic PIV에 의한 실린더 후류의 위상평균된 3차원 구조 (Phase-Locked Three-Dimensional Structures in the Cylinder Wake Observed from Cinematic PIV Data)

  • 성재용;박강국;유정열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.661-666
    • /
    • 2000
  • Near-wake flow field of a circular cylinder is studied by means of a cinematic PIV system with high sampling rate and large internal memory block. Experiments are conducted in a closed-cycle water tunnel system and a cross-correlation algorithm in conjunction with FFT (Fast Fourier Transform) analysis and an offset correlation technique is used for vector processing. With the help of very high sampling frequency compared to the shedding frequency, it is possible to obtain phase-averaged information of the three-dimensional wake, even though the shedding is not forced but natural. Phase-locked vortical structures observed simultaneously from the spanwise and cross-stream planes are displayed in the wake-transition regime where fine-scale secondary vortices have a spanwise wavelength or around one diameter. Spatial relations and temporal evolutions of the primary Karman vortex and the secondary vortex are also discussed schematically.

  • PDF

철/크롬 오버레이합금의 파괴인성에 미치는 크롬탄화물 양의 영향 (Effect of Volume Fraction of Chromium Carbide on Fracture Toughness of the Iron/Chromium Hardfacing Alloy)

    • Journal of Welding and Joining
    • /
    • 제16권2호
    • /
    • pp.64-72
    • /
    • 1998
  • This study aims a investigating the effect of volume fraction of chromium carbide phase(VFC) of hardfaced iron/chromium alloys on fracture toughness. The alloys were deposited twice on a mild steel plate using self-shielding flux cored arc welding process. In order to examine VFC effect, different VFC (0.28∼0.62) were employed by changing the Cr and C content, while the ratio of Cr/C was fixed in the range of 5.7∼6.6. Fracture toughness was constant as increasing VFC because fracture surface was developed in the eutectic phase which was growing parallel with introduced sharp notch in the hypoeutectic alloys, but fracture toughness did not decreased in spite of increasing volume fraction of coarse primary chromium carbide phase which was easily craced at the low stress because the growth direction of chromium carbide phase were more irregular as increasing VFC in the hypereutectic alloys.

  • PDF

Electrochemical Parameters with unusual Alternating Current Phase-Angles

  • Rashwan Farouk;Mohran Hossnia
    • 전기화학회지
    • /
    • 제7권2호
    • /
    • pp.80-82
    • /
    • 2004
  • The a.c. technique is employed to evaluate electrochemical characteristics of Naphthalie-1,4,5,8-tetracarboxylic acid bisanilide (NTB). The measurements were carried out in dry and pure propionitrle (PCN) and acetonitrile(CAN) at the hanging mercury drop electrode [HMDE). An A.C. phase sensitive detector using computer controlled lock-in amplifier was employed. Primary goal of this report, was to establish on a firm the rare behavior of the phase angle associated with a.c. polarograms of the compound. Although, not an initial goal of this study, the electron transfer rate parameters attending the electroreduction of the compound under investigation were determined. This because the results shed some light on the electrokinetics in aprotic solvent which until recently negligible data were available. Experimental Results and comparison of data obtained are reported. The good precision of the method makes it suitable for studying electrochemical data with unusual behavior at electrodes in non aqueous media.

심근경색후 물리치료 (Physical Therapy for Post-Myocardial Infarction)

  • 이정원
    • 한국전문물리치료학회지
    • /
    • 제1권1호
    • /
    • pp.83-87
    • /
    • 1994
  • The purpose of this paper is to provide an overview of the clinical physical therapy program used at the University of Yonsei Rehabilitation Hospital, for the practicing university trained physical therapists who may be unfamiliar with patients who have suffered a myocardial infarction. The four primary phases of the cardiac physical therapy graded exercise program are: 1) coronary care unit program (phase I), 2) general ward program (phase II), 3) convalescence program (phase III), 4) maintenance program (phase IV). The exercise prescription defines the exercise intensity, duration, frequency, and mode of exercise a after pre- discharge low level graded exercise test(LL-GXT) or symptom limited maximum graded exercise test. A typical exercise routine consists of preparation warm-up exercise, therapeutic exercise, cool-down exercise. Physical therapy is involved in the acute care and rehabilitation of the patient after a myocardial infarction. Therefore, the physical therapist must throughly comprehened the cardiac anatomy, cycle, performance, conduction system, pathogenesis, risk factors, and exercise benefits.

  • PDF

단상 AC/DC PWM 병렬 컨버터의 순시 제어 (Instantaneous Control of Single Phase AC/DC PWM Parallel Converters)

  • 원준희;정달호;오재윤
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.356-359
    • /
    • 2001
  • In this paper, the new control algorithm is proposed that compensates instantaneously the active and reactive components of the input currents by the synchronous d,q axis conversion of a single-phase current in controlling the single-phase AC/DC parallel converters for a high speed train. The leakage inductance of a transformer was used as a boost inductance and the ripple of a transformer's primary current was reduced considerably by the parallel operation of the two converters with a proper switching phase-shift. The stable and fast control response characteristic is certificated by a simulation.

  • PDF

홀드 업 타임 보상회로를 가진 IT 기기용 Front-end PSFB DC/DC 컨버터 (Phase-Shifted Full Bridge(PSFB) DC/DC Converter with a Hold-up Time Compensation Circuit for Information Technology (IT) Devices)

  • 이강현
    • 전력전자학회논문지
    • /
    • 제18권5호
    • /
    • pp.501-506
    • /
    • 2013
  • A hold-up time compensation circuit is proposed to get high efficiency of the front-end phase-shifted full bridge DC/DC converter. The proposed circuit can make the phase-shifted full bridge front-end DC/DC converter built with 0.5 duty ratio so that the conduction loss of the primary side and voltage stress across rectifier in the secondary side are reduced and the higher efficiency can be obtained. Furthermore, the requirement of an output filter significantly can diminish due to the perfect filtered waveform. A 12V/100A prototype has been made and experimental results are given to verify the theoretic analysis and detailed features.

철심형 전류변성기의 비오차 및 위상오차 절대 평가 기술의 확장 : 1차 전류 = $5\;kA{\sim}40\;kA$ (Extension of Absolute Evaluation Technique for Ratio Error and Phase Displacement of Core Type Current Transformers: Ip =$5\;kA{\sim}40\;kA$)

  • 김윤형;한상길;정재갑;한상옥
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.431-436
    • /
    • 2008
  • We have extended an absolute evaluation method to obtain the ratio error and phase displacement of a current transformer (CT) up to primary current of 40,000 A by measuring four parameters of equivalent circuit in CT. The method was applied to CTs under test with the current ratios in the range of 5,000 A / 5 A - 40,000 A / 5 A. The ratio error and phase displacement of the CTs under test obtained in this study are consistent with those measured at the national institutes in Canada and Germany using the same CTs under test within an expanded uncertainty (k = 2) in the overall current ratios.