검색결과 355건 처리시간 0.029초

관성측정장치를 이용한 경추관절 가동범위 측정의 검사 내 반복성 및 검사-재검사 신뢰도 연구 (Test-retest Reliability and Intratest Repeatability of Measuring Cervical Range of Motion Using Inertial Measurement Unit)

  • 김현호;김경욱;박지민;김은석;이민준;강중원;이상훈;박영배
    • Journal of Acupuncture Research
    • /
    • 제30권4호
    • /
    • pp.25-33
    • /
    • 2013
  • Objectives : To assess the test-retest reliability and the intratest repeatability in measuring the cervical range of motion of healthy subjects with wireless microelectromechanical system inertial measurement unit(MEMS-IMU) system and to discuss the feasibility of this system in the clinical setting to evaluate the cervical spine musculoskeletal. Methods : 12 healthy people who were evaluated as no- or mild-disability with neck disability index were participated. Their cervical motion were measured with IMU twice in consecutive two days for the test-retest reliability study. Intratest repeatability was calculated in the two tests separately. The calculated intraclass correlation coefficients(ICC) were discussed and compared with the those of the previous studies. Results : Cervical range of motion data were acquired and statistically processed: left rotation($61.64^{\circ}$), right rotation($65.12^{\circ}$), extension($61.98^{\circ}$), flexion($52.81^{\circ}$), left bending($39.31^{\circ}$), right bending($41.08^{\circ}$). ICCs were 0.77~0.98(intratest repeatability) and 0.74~0.93 (test-retest reliability) in the primary motion. In the coupling motion, intratest repeatability ICCs were 0.93~ 0.99(transverse primary plane), 0.88~0.97(saggital primay plane), and 0.77~0.93(coronal primary plane). Test-retest reliability of coupling motion were 0.90~0.97(transverse primary plane), 0.00~0.72(saggital primary plane), and 0.04~0.76(coronal primary plane). Conclusions : Several types of range-of-motion devices are now on use in many fields including medicine, but the practicality of the devices in clinical use is questionable for the convenient and economical aspects. In this study, we presented the reliability of cervical range of motion test with the developed wireless MEMS-IMU system and discussed its potential utility in clinical use.

회전-리니어 병용 유도전동기의 특성해석 (Optimal Construction of Rotary-Linear Induction Motor)

  • 오누끼 다까시;전우진;다나비끼 마사모토;유지윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.130-132
    • /
    • 1997
  • In this paper, we propose a new type of tubular linear induction motor(TLIM) with two-dimensional motion. The proposed motor consists of four short primary LIMs arranged on a same circumference and a common secondary. By adopting independently energized ring-windings to the primary, we can expect the reduction of coil-end region and the freedom of alternating current supply. The secondary conductor is capable of producing anyone of rotary, linear, and helical motions by controlling the phase of supply currents in each primary winding. From the 3-D finite element analysis and the experiment, we derive the feeding conditions to increase the subsidiary rotary-force and an optimal arrangement of primary currents to reduce the number of slot.

  • PDF

Energy approach for dynamic buckling of shallow fixed arches under step loading with infinite duration

  • Pi, Yong-Lin;Bradford, Mark Andrew;Qu, Weilian
    • Structural Engineering and Mechanics
    • /
    • 제35권5호
    • /
    • pp.555-570
    • /
    • 2010
  • Shallow fixed arches have a nonlinear primary equilibrium path with limit points and an unstable postbuckling equilibrium path, and they may also have bifurcation points at which equilibrium bifurcates from the nonlinear primary path to an unstable secondary equilibrium path. When a shallow fixed arch is subjected to a central step load, the load imparts kinetic energy to the arch and causes the arch to oscillate. When the load is sufficiently large, the oscillation of the arch may reach its unstable equilibrium path and the arch experiences an escaping-motion type of dynamic buckling. Nonlinear dynamic buckling of a two degree-of-freedom arch model is used to establish energy criteria for dynamic buckling of the conservative systems that have unstable primary and/or secondary equilibrium paths and then the energy criteria are applied to the dynamic buckling analysis of shallow fixed arches. The energy approach allows the dynamic buckling load to be determined without needing to solve the equations of motion.

Adaptive V1-MT model for motion perception

  • Li, Shuai;Fan, Xiaoguang;Xu, Yuelei;Huang, Jinke
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권1호
    • /
    • pp.371-384
    • /
    • 2019
  • Motion perception has been tremendously improved in neuroscience and computer vision. The baseline motion perception model is mediated by the dorsal visual pathway involving the cortex areas the primary visual cortex (V1) and the middle temporal (V5 or MT) visual area. However, few works have been done on the extension of neural models to improve the efficacy and robustness of motion perception of real sequences. To overcome shortcomings in situations, such as varying illumination and large displacement, an adaptive V1-MT motion perception (Ad-V1MTMP) algorithm enriched to deal with real sequences is proposed and analyzed. First, the total variation semi-norm model based on Gabor functions (TV-Gabor) for structure-texture decomposition is performed to manage the illumination and color changes. And then, we study the impact of image local context, which is processed in extra-striate visual areas II (V2), on spatial motion integration by MT neurons, and propose a V1-V2 method to extract the image contrast information at a given location. Furthermore, we take feedback inputs from V2 into account during the polling stage. To use the algorithm on natural scenes, finally, multi-scale approach has been used to handle the frequency range, and adaptive pyramidal decomposition and decomposed spatio-temporal filters have been used to diminish computational cost. Theoretical analysis and experimental results suggest the new Ad-V1MTMP algorithm which mimics human primary motion pathway has universal, effective and robust performance.

강선 견인을 이용한 아킬레스 건 파열의 수술적 치료 (Repair of Achilles tendon tear with distal wire pulling)

  • 김부환;이상훈;허무중;유성호
    • 대한족부족관절학회지
    • /
    • 제6권1호
    • /
    • pp.86-91
    • /
    • 2002
  • Purpose: This study was designed to evaluate whether the method "Distal pulling with wire" after primary repair of Achilles tendon, can result in early restoration of ankle motion. Materials and Methods: In 14 cases of tendocalcaneus repair, the proximal stump was pulled down distally by wire and fixed the ends of wire to the transcalcaneal K - wire. We evaluated the range of motion of ankle joint at 4th, 6th, 12th week in 10 patients whom we followed up for more than 1 year. We evaluated the results of Achilles tendon repair by Hooker's criteria. Results: Range of motion of ankle joint revealed as follows. Degree of mean dorsiflexion improved - $5.1^{\circ},\;15.0^{\circ},\;22.4^{\circ}$ at 4th, 6th and 12th week respectively, while plantarflexion improved $21.5^{\circ},\;32.7^{\circ}$ and $42.3^{\circ}$ respectively. At one year follow up, seven of them had no problems in active daily life and sports activities. According to Hooker's criteria, the result rated excellent in nine, satisfactory in one. Conclusion: Early gain of ankle joint motion was possible by "Distal pulling with wire" after primary repair of Achilles tendon.

  • PDF

The Effects of Three Dimensional Stimulus Configuration on Self-Motion Perception Induced by Large Visual Display

  • Nakamura, Shinji
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.1031-1034
    • /
    • 2007
  • The interactions between two-dimensional and three-dimensional stimulus configurations on visually induced self-motion perception (vection) were examined. The experiment revealed that there is no 2D-3D interaction, and vection strength is determined solely by the size of the moving background stimulus, which should be a primary factor in inducing vection.

  • PDF

주구조물 및 부구조물에 대한 감진장치의 지진응답 감소 효율성 (Effectiveness of Isolation-System on Reduction of Seismic Response of Primary and Secondary Structures)

  • 김영상;이동근
    • 대한토목학회논문집
    • /
    • 제12권4_1호
    • /
    • pp.9-21
    • /
    • 1992
  • 논문에서는 주구조물의 기초와 부구조물의 지지점에 설치된 감진장치가 구조물의 지진응답 감소에 미치는 영향을 분석하였다. 여러가지 지진하중의 특성에 따른 감진장치가 설치된 주구조물과 부구조물의 거동을 비교분석하였으며, 이때 사용된 해석모델은 고정기초 구조물에 지지점이 고정된 부구조물, 감진기초 구조물에 지지점이 고정된 부구조물, 고정기초 구조물에 지지점 감진장치가 설치된 부구조물과 같은 세가지이다. 부구조물의 응답계산에서는 주구조물과 부구조물의 상호작용을 고려하였다. 계산에 사용한 수치적분방법은 constant average acceleration 방법이며, 이 방법과 축소행렬방법을 이용한 전산프로그램(KBISAP)을 사용하였다. 또한 지진하중에 대한 구조물의 지면에 대한 상대변위를 제한시키기 위하여 여러가지 지진하중에 대한 구조물의 가속도와 변위의 상관관계를 계산하여 감진장치의 적합한 수평강성을 분석하였다.

  • PDF

감쇠진동계에 부착된 코일스프링과 오일댐퍼로 구성된 동흡진기

  • 최석창;안찬우;박일수;이희범
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.289-293
    • /
    • 1996
  • Vibration absorber is used to protect the primary system from steady-state harmonic disturbance. By attaching the absorber to the primary system which is modeled as a SDOF system, the new system becomes two DOF system. Depending on the driving frequency on the original system, the absorber needs to be carefully tuned, that is, to choose adequate value of the absorber mass and stiffness, so that the motion of the original mass is a minimum. This paper presents the effects of resonance frequency ratio and of vibration absorber with oil damper and coil spring for linear damped primary systems.

  • PDF