• Title/Summary/Keyword: preventive repair

Search Result 158, Processing Time 0.028 seconds

The Protective Effects of $Hwangyeon-tang$ on Acute Gastric Ulcer induced by HCl/EtOH solution in Rats (흰쥐의 급성 위점막 손상에서 황연탕(黃蓮湯)이 apoptosis 관련단백질 및 성장인자 발현에 미치는 영향)

  • Kim, Bum-Hoi
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.16 no.1
    • /
    • pp.57-70
    • /
    • 2012
  • The apoptotic process of gastric mucosa triggered by induction of proapoptotic gene expression, such as Bax. Stress-inducing factors may affect Bcl-2/Bax ratio and thus the rate of apoptosis through modulation of the expression of both proteins depending upon the experimental model. TGF-${\beta}$ is believed to be essential in wound healing for regulation of cell growth and differentiation and is known to be involved in tissue repair and remodeling. The polypeptide growth factors, such as vascular endothelial growth factor(VEGF), regulate essential cell functions involved in tissue healing including cell proliferation, migration, and differentiation. The purpose of this study was to investigate whether the oral administration of $Hwangyeon-tang$ (HYT) would have protect effects on gastric ulcer in rat. Sprague-Dawley rats (n=40) were randomly divided into 4 groups ; Normal, Saline, Cimetidine and HYT group. The saline, cimetidine and HYT extract were orally administrated to each group and gastric ulcer was induced with HCl/EtOH solution. After 1 hour, the stomachs were collected for histological observation and immunohistochemistry. In Results, the wound healing of gastric ulcer was promoted by HYT and the significant alterations of BAX/Bcl-2, TGF-${\beta}1$ and VEGF proteins in gastric mucosa were observed. These results suggest that Fritillaria ussuriensis extract promotes wound healing and has protective effects on gastric ulcer in rats.

Availability Analysis of Multiplex Systems using Software Rejuvenation Method (소프트웨어 재활 기법을 적용한 다중계 시스템의 가용도 분석)

  • Park, Kie-Jin;Kim, Sung-Soo;Kim, Jai-Hoon
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.27 no.8
    • /
    • pp.730-740
    • /
    • 2000
  • The software rejuvenation method for highly available multiplex systems uses a pro-active fault-tolerant approach to handle system failures. The software rejuvenation prevents failures from occurring, while the previous methods recover from failures after happening. Especially, since the software aging proceeds fast in the software used for the multimedia mobile computing due to the loss of communications or data, the preventive method from failures using software rejuvenation can be used for the multimedia mobile computing. In this paper, according to the operational parameters such as rejuvenation period, rejuvenation time, failure rate and repair rate of the servers, number of running servers, duration of running time, and type of running modes, we calculate steady-state probabilities, downtime, availability, and cost of the multiplex systems using software rejuvenation method. We validate the closed-form solutions of the mathematical model by experiments based on various operational parameters and find that the software rejuvenation method can be adopted as preventive fault-tolerant technique. The failure rate and unstable rate of the servers are essential factors for the decision making of the rejuvenation policies.

  • PDF

Lactobacillus brevis KB290 Enhances IL-8 Secretion by Vibrio parahaemolyticus-Infected Caco-2 Cells

  • Yakabe, Takafumi;Shimohata, Takaaki;Takahashi, Akira
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.1
    • /
    • pp.118-124
    • /
    • 2013
  • Vibrio parahaemolyticus in uncooked seafood causes acute gastroenteritis. The microorganism has two sets of type III secretion systems and two hemolysins. When it injects its effector proteins into a host cell via type III secretion system 1, one of the type III secretion systems induces secretion of interleukin (IL)-8, a proinflammatory chemokine, through the phosphorylation of ERK 1/2 and p38 MAPK. Although probiotics have beneficial effects on hosts and can help control some infectious diseases, there is little research on the efficacy of probiotics in V. parahaemolyticus infection. Here we pretreated V. parahaemolyticus-infected human intestinal epithelial cells with heat-killed Lactobacillus brevis KB290, a probiotic isolated from fermented vegetables (traditional Japanese pickles) and utilized as an ingredient of beverages and supplementary foods, and demonstrated its efficacy in enhancing IL-8 secretion from V. parahaemolyticus-infected cells. Among the three heat-killed lactic acid bacterial strains we tested, L. brevis KB290 induced the highest level of IL-8 secretions in the infected cells. Relative to control cells (Caco-2 cells pretreated with PBS), V. parahaemolyticus-infected Caco-2 cells pretreated with heat-killed L. brevis KB290 secreted IL-8 earlier, although concentrations were similar 450min after infection. Heat-killed L. brevis KB290 pretreatment also induced earlier ERK 1/2 phosphorylation, greater p38 MAPK phosphorylation, and enhanced IL-8 mRNA expression. Heat-killed L. brevis KB290 accelerated IL-8 secretion, a host cell immune response, in V. parahaemolyticus-infected cells. We consider this to be beneficial because IL-8 plays an important defensive role against infection, and would contribute to the repair of injured epithelial cells.

Development on Communication Device with Timeliness Guaranteed for "GIS Preventive and Diagnosis System" (GIS 예방진단 시스템을 위한 정시간성 보장형 통신기기 개발)

  • Min, B.W.;Park, C.S.;Myoung, H.C.;Choi, H.W.;Kim, J.H.;Lee, B.H.;Park, D.H.;Kim, Y.K.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2032-2033
    • /
    • 2007
  • There has been increasing interests of condition monitoring and diagnosis for electric equipment, which lead to the development of this system domestic and abroad. In the past, operators' interest was how to quickly repair and restore the electric equipments after failure. But, due to the North American Blackout in 2003 and the aging of equipments, users have paid attention to the condition based monitoring of electric equipment to prevent a fault like outrage. GIS-PDS("GIS Preventive and Diagnosis System") requiresa large amount of measurement data with timeliness for monitoring and analysis of real-time state of GIS(Gas Insulated Switchgear). We developed the timeliness-guaranteed communication device for GIS-PDS.

  • PDF

Analysis of Trends in Patients with Work-related Musculoskeletal Disorders and Literature Review of Risk Factors and Prevalence (작업관련 근골격계질환의 요양재해 추이 분석 및 위험요인과 유병률에 관한 고찰)

  • Nam-Soo Kim;Yong-Bae Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.3
    • /
    • pp.298-307
    • /
    • 2023
  • Objectives: The purpose of this study is to analyze the recent trends in patients with work-related musculoskeletal disorders in South Korea and to check the major results by reviewing the literature on the risk factors and prevalence of musculoskeletal diseases related to work. Methods: Industrial disaster data from the Ministry of Employment and Labor from 2012 to 2021 were used, and the literature was reviewed regarding risk factors for musculoskeletal diseases related to work using PubMed and RISS. Results: The trend of patients with work-related musculoskeletal disorders has increased overall since 2017 after declining until 2016, with a particularly notable increase in the average annual number of patients with physical burden work. The average annual rate per ten thousand people for patients with body burden work, non-accidental lower back pain, and carpal tunnel syndrome among work-related diseases was high in the mining industry. The average annual rate per ten thousand people for patients with accidental lower back pain was the highest in the fishing industry. Within the manufacturing field, it was the highest in the shipbuilding and ship repair industry. As a result of the literature review, the search rate for work-related musculoskeletal disease papers in unstructured work was high. In addition, physical stress factors were high among risk factors, and pain areas showed a high rate for the waist. Conclusion: Even after the institutional implementation of a hazard investigation system related to musculoskeletal diseases is implemented, the number of patients with occupational musculoskeletal disorders continues to increase. Therefore, it is necessary to conduct regular surveys and implement effective improvement activities for vulnerable industries or occupations.

Outcome of Concomitant Cox Maze Procedure with Narrow Mazes and Left Atrial Volume Reduction

  • Choi, Jong Bum;Kim, Jong Hun;Cha, Byong Ki
    • Journal of Chest Surgery
    • /
    • v.47 no.4
    • /
    • pp.358-366
    • /
    • 2014
  • Background: To improve sinus rhythm conversion, the Cox maze III procedure with narrow mazes (width: ${\leq}3.0cm$) was performed in combination with left atrial volume reduction. Methods: From October 2007 to April 2013, 87 patients with atrial fibrillation (paroxysmal in 3, persistent in 14, and permanent in 70) underwent the Cox maze procedure concomitant with another cardiac procedure. They were followed-up with serial electrocardiographic and echocardiographic studies. We used 24-hour Holter monitoring tests to evaluate postoperatively symptomatic patients. Results: At the mean follow-up time of 36.4 months, 81 patients (94.2%) had sinus rhythm and two were on anti-arrhythmic medication (one on a beta-blocker and the other on amiodarone). Five patients (5.8%) with postoperative recurrent and persistent atrial fibrillation never experienced sinus rhythm conversion; however, they did not require any medication for rate control. On postoperative echocardiography, the left atrial A waves were more frequently observed after concomitant mitral valve repair than after concomitant mitral valve replacement (82.4% vs. 40.4%, respectively; p<0.001). Conclusion: For the Cox maze procedure, narrow mazes and atrial volume reduction resulted in excellent sinus rhythm conversion without the preventive use of anti-arrhythmic drugs, and they did not affect the presence of the left atrial A waves on echocardiography.

Development of Implementation Procedure for Reliability Centred Maintenance with Causing Analysis (원인분석을 통한 신뢰성 중심의 유지보수 시스템 절차 개발)

  • Lee, Hern-Chang;Choi, Min-Hong;Lim, Dong-Ho;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.4
    • /
    • pp.16-20
    • /
    • 2017
  • Current maintenance system are unable to suggest solid basis of maintenance for roating and static equipment. When a filure occurs, replacement or repair without proper process of failure cause analysis would often result in even greater risk. Therefore in this study, a procedure of Reliability Centred Maintenance is develped in order to perform maintenance in preventive mainer (PM), and to effectively manage risk of any equipment based on failure types and respective rates of failure. Ultimately an equipment with higher risk will be monitored which will lead to effectively prevent and manage any major accident.

Clinical Characteristics of Small Bowel Perforation due to Blunt Abdominal Trauma (복부 둔상으로 인한 소장 천공의 임상 양상에 대한 고찰)

  • Bae, Jung-Min
    • Journal of Trauma and Injury
    • /
    • v.24 no.2
    • /
    • pp.125-128
    • /
    • 2011
  • Purpose: Blunt small bowel injury (SBI) is frequently combined other organ injury. So, clinical outcome and characteristics of SBI are influenced by other combined injuries. Thus, we analyzed isolated SBI patients and studied clinical outcome and characteristics. Methods: Between 2005 and 2010, 36 consecutive patients undergoing laparotomy due to isolated SBI were identified in a retrospectively collected. Database. Clinical outcome and characteristics were analyzed. Results: Laparotomy was performed in 36 patients. Primary repair was performed 17 patients. Segmental resection of small bowel was performed 19 patients. Median time gap from trauma to operation was 9 hours. In 24 hours from trauma, operation was performed 31 patients. Post operative death was 5 patients. Mean hospital stay was 18 days and median hospital stay was 12 days. There were significant differences between operation type and minor complication and hospital stay. And there were significant differences between time gap in 24 hours and minor complication. But, there were no significant between time gap and mortality. Conclusion: Although this study had many limitations, some valuable information was produced. When operation above 24 hours was delayed in SBI, minor complications were significantly increased. Segmental resection of small bowel in SBI were significantly increased minor complications and hospital stay. So, preventive measures for surgical site infection was important to reduce wound complication and hospital stay. Further continuous study and multi-center study were should be performed to improve clinical outcome in SBI.

Study on Reliability of Water Absorption Diagnosis through Precise Water Absorption Test

  • Kim, Hee-Soo;Bae, Yong-Chae;Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.5
    • /
    • pp.772-777
    • /
    • 2012
  • Accidents caused by water absorption in water-cooled generator stator windings often occur all over the world. The absorption into the insulator of the coolant, which is used to cool down the heat generated by stator windings during operation, leads to the deterioration of dielectric strength, and insulation breakdown. An insulation breakdown may cause not only an enormous economic loss but also a very serious grid accident that would compromise stable supply of electric power. More than 50 % of domestic generators have been in operation for more than 15 years, and water absorption tests performed on 50 water-cooled generator stator windings during a five-year planned preventive maintenance period beginning in 2006 identified water absorption problems in 10 of them, all of which required repair. Because the existing water absorption test detects this problem by utilizing stochastic methods after measuring the capacitances at the final positions of insulation breakdown, its accuracy is limited. This study demonstrates that water absorption can be more accurately diagnosed by utilizing method along with a more precise one.

Optimal Maintenance Cycle for Aviation Oil Testing Equipment under the Consideration of Operational Environment (운용환경을 고려한 항공오일시험장비의 최적정비주기 설정)

  • Kim, In Seok;Jung, Won
    • Journal of Applied Reliability
    • /
    • v.16 no.3
    • /
    • pp.224-230
    • /
    • 2016
  • Purpose: Military maintenance involves corrective and preventive actions carried out to keep a system in or restore it to a predetermined condition. This research develops an optimal maintenance cycle for aviation oil testing equipment with acceptable reliability level and minimum maintenance cost. Methods: The optimal maintenance policy in this research aims to satisfy the desired reliability level at the lowest cost. We assume that the failure process of equipment follows the power law non-homogeneous Poisson process model and the maintenance system is a minimal repair policy. Estimation and other statistical procedures (trend test and goodness of fit test) are given for this model. Results: With time varying failure rate, we developed reliability-based maintenance cost optimization model. This model will reduce the ownership cost through adopting a proactive reliability focused maintenance system. Conclusion: Based on the analysis, it is recommended to increase the current maintenance cycle by three times which is 0.5 year to 1.5 years. Because of the system's built-in self-checking features, it is not expected to have any problems of preventative maintenance cycle.