• 제목/요약/키워드: prestressing force

검색결과 189건 처리시간 0.023초

Theoretical and experimental research of external prestressed timber beams in variable moisture conditions

  • Miljanovic, Sladana;Zlatar, Muhamed
    • Coupled systems mechanics
    • /
    • 제4권2호
    • /
    • pp.191-209
    • /
    • 2015
  • Hybrid girders can be constructed in different geometrical forms and from different materials. Selection of beam's effective constellation represents a complex process considering the variations of geometrical parameters, changes of built in material characteristics and their mutual relations, which has important effect on the behavior of the girder. This paper presents the theoretical and experimental research on behavior of the timber-steel hybrid girders' different geometrical constellation with external prestressing and in different conditions of timber moisture. These researches are based on linear elastic analysis, and further refine by using the plasticity and damage models.

긴장재 절단에 따른 프리텐션 부재의 동적 거동 고찰 (Dynamic Behavior of Pretensioned Concrete Member during Detensioning)

  • 김장호;문도영;지광습;김규선
    • 대한토목학회논문집
    • /
    • 제28권5A호
    • /
    • pp.747-756
    • /
    • 2008
  • 본 논문에서는 전달길이에 영향을 미치는 인자에 따라 프리텐션 부재가 받는 동적 충격에 의한 영향을 실험적으로 고찰하였다. 이를 위해 긴장재의 직경, 콘크리트의 피복 두께, 구속 철근과 비부착 구간의 유무, 긴장력 도입 방식을 변수로 한 10개의 프리텐션 콘크리트 부재를 제작하고, 긴장재에 부착한 전기 저항식 변형률 게이지를 통하여 부재에 긴장력 도입 시 변형률 변화를 동적으로 측정하였다. 실험 결과, 순간 전달 방식으로 긴장력을 도입할 때 절단단부에서 큰 동적 효과가 발생하는 것을 확인할 수 있었다. 또한, 변형률 변화량으로 각 부재의 긴장력을 비교한 결과, 각 인자에 따라 차이가 존재하는 것을 확인했다. 직경 15.2 mm 강선보다 12.7 mm 강선의 잔류 긴장력 비율이 더 컸으며, 75 mm의 콘크리트 피복 두께만으로도 충분한 구속 효과를 기대할 수 있는 것으로 판단된다. 구속 철근의 영향은 미미했고, 비부착 구간의 영향으로 잔류 긴장력이 향상되었다. 순간 전달 방식보다 지연 전달 방식으로 긴장력을 도입할 때 긴장력 손실이 적은 것으로 확인되었다.

계측 센서를 활용한 PSC 거더 텐던의 긴장력 측정 실험 (Experimental Evaluation of Prestress Force in Tendons for Prestressed Concrete Girders using Sensors)

  • 신경준;박영웅;이성철;김윤용;이환우
    • 한국전산구조공학회논문집
    • /
    • 제28권6호
    • /
    • pp.715-722
    • /
    • 2015
  • 프리스트레스(PS) 긴장재의 긴장력 관리는 거더 성능관리에 있어 매우 중요한 항목이나 현재는 시공시 설계 긴장력의 도입 여부만을 검증한 후 공용시에는 그 관리가 이루어지지 않는 실정이다. 이에 본 연구에서는 PSC 거더의 제작단계에서부터 공용시까지 생애주기 동안의 긴장력 관리가 가능한 PSC 거더를 제안하기 위한 기초 연구로서, 현재의 기술수준으로 사용 가능한 센서들을 이용하여 PS 긴장력을 측정하는 실험 연구를 수행하였다. 소규모 거더를 제작하여 4종류의 센서를 설치하였고, 긴장력을 도입하면서 각 센서들의 적용성과 정확성을 평가하였다. 실험결과에 따르면, 중공로드셀은 편심하중이 작용하는 경우 기준값보다 하중을 높게 평가하는 경향이 있었다. EM 센서는 실용이 가능한 정확도를 보여주었으며, 콘크리트 내부의 긴장재를 따라 어느 위치에서도 설치할 수 있다.

프리스트레스 손실량을 고려한 270,000kL급 LNG 저장탱크 외조의 비산물체 속도에 따른 충돌 거동 해석 (Analysis Evaluation of Impact Behavior of 270,000kL LNG Storage Outer Tank from Prestress Force Loss)

  • 이상원;전하영;김장호;김준휘;이강원
    • 한국가스학회지
    • /
    • 제18권1호
    • /
    • pp.31-40
    • /
    • 2014
  • LNG 저장탱크의 외조는 콘크리트 부재로 수직 방향 및 원환 방향 프리스트레싱 벽체 구조인데, 저장탱크의 대형화가 이루어짐에 따라 프리스트레싱 구간이 길어지고 결과적으로 프리스트레스 손실량이 증가하고 있다. 본 연구는 주요 사회기반시설구조물의 하나인 LNG 저장탱크에 비행체 충돌과 같은 사고가 발생하였을 때 안전성 향상을 위하여 충돌 저항 성능에 대한 분석연구를 수행하였다. 해석은 유한요소해석 프로그램인 LS-DYNA를 사용하여 270,000kL급 LNG 저장탱크 외조의 비산물체 충돌에 대한 거동을 평가해보고자 하며, 해석 시 LNG 저장탱크의 대형화로 인한 PS 텐던의 길이증가에 따른 프리스트레스 손실 또한 고려될 것이다. 또한 프리스트레스 손실의 적용 유무에 따른 비산 물체 충돌에 대한 PSC 구조물의 거동 비교를 통해 구조물의 안전성 및 사용성을 평가해보고자 한다. 이 연구의 결과를 통해 프리스트레스 손실량의 적용에 따른 구조물의 거동 변화를 확인하고, 설계시 안전성 기준 및 검토의 보조자료로 활용할 수 있도록 하고자 한다.

실측값에 근거한 마찰계수의 추정 (Estimation of Friction Coefficients Based on Field Data)

  • 전세진;박종칠;박인교;심별
    • 대한토목학회논문집
    • /
    • 제29권5A호
    • /
    • pp.487-494
    • /
    • 2009
  • PSC 구조물에 사용되는 긴장재의 마찰계수는 긴장작업시 긴장력 관리를 위한 기본적인 정보가 된다. 그러나, 마찰계수는 국내외 설계기준별로 큰 차이가 있어 실무자들에게 혼란을 주어 왔다. 이 연구에서는 먼저 국내외의 관련 설계기준을 비교 분석하여 현재 통용되고 있는 마찰계수의 범위를 파악해 보았다. 그리고 긴장시의 신장량과 긴장력과 같은 실측값과 마찰계수에 대한 이론식을 조합하여 파상 및 곡률 마찰계수값을 역으로 유추할 수 있는 절차를 제안하였다. 예제로서 ILM, FCM 및 MSS 공법으로 시공된 국내 PSC 교량들을 대상으로 다양한 형상을 가진 텐던들에 제안된 절차를 적용하였다. 이를 통해 계산된 마찰계수값들을 설계기준이나 긴장시 가정되었던 값들과 비교하였으며, 이를 바탕으로 합리적인 마찰계수값의 범위에 대해 논하였다. 이 때 몇몇 교량에서는 lift-off 시험으로 고정단 긴장력을 추가적으로 측정하여 결과를 검증하는데 참조하였다. 파상 마찰계수의 경우 AASHTO 기준만큼 작은 값은 아니지만 국내 기준의 하한값에서 중간값 정도에 분포했다. 한편, 곡률 마찰계수는 국내 기준의 상한값에 가깝거나 이를 다소 상회하는 것으로 나타났다.

비선형 유한요소해석을 이용한 조립식 교각의 성능 평가 (Evaluation of Structural Performance of Precast Prefabricated Bridge Column using Nonlinear Finite Element Analysis)

  • 정철헌;윤연석;황은정
    • 대한토목학회논문집
    • /
    • 제28권3A호
    • /
    • pp.383-390
    • /
    • 2008
  • 교량의 하부구조에 프리캐스트 공법을 적용하기 위해 제안된 조립식 교각은 강관과 강봉을 연결구조로 활용하였으며, 강봉에 긴장력을 도입하여 교각의 일체화를 도모하였다. 제안된 조립식 교각 시스템을 적용하여 교각 실험체를 제작하였으며, 준정적 실험을 수행하였다. 실험결과, 교각 실험체의 파괴모드는 휨파괴로 나타났으며, 이음부에서의 손상은 발생하지 않았다. 또한 강봉에 도입된 긴장력으로 변형에 대한 복원능력이 우수하며, 교각의 연성능력이 내진설계기준을 만족하는 것을 확인하였다. 실험체를 대상으로 비선형 유한요소해석을 수행하였으며, 해석기법의 타당성을 검증하였다. 조립식 교각의 하중-변위 관계와 균열발생 위치에 대한 해석결과가 실험결과와 일치함을 확인함으로서 해석방법의 타당성을 확인하였다. 조립식 교각의 강재비, 강봉에 도입되는 긴장력, 콘크리트의 강도를 변수로 하여 비선형유한요소해석을 수행하였다. 해석결과를 통하여 제안된 조립식 교각 시스템의 적절한 수준의 강재비와 강봉에 도입되는 긴장력 등을 정성적으로 평가하였다.

슬래브교 외부 강선 보강용 정착구 개발 (Development of the Braket for External Prestressing Method in Slab Bridge)

  • 한만엽;이상열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.93-98
    • /
    • 2001
  • This study is to develop the end anchorage of external steel reinforcement of RC slab bridges. External prestress method using the existing steel is that When the anchorage is installed in slab end, a plenty of anchor bolts were required because the only tangential stress of anchor bolt received a tendon force. Then, for this reason, the wide end anchorage was required and the shape was complicate. But this reinforcement method using method that inserts anchor key at concrete surface cut a groove gets big internal force comparing to the anchorage using existing anchor bolt. Furthermore, the number of anchor bolt for installing apparently will be reduced, and the operation will be convenient because a small anchorage of a simple shape will be received a great tendon force

  • PDF

콘크리트 교량의 외부강선 보강을 위한 앵커키 정착장치의 개발 연구 (Development of the Bracket for External Prestressing Method for Slab Bridge)

  • 한만엽;이상열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.1009-1014
    • /
    • 2001
  • This study is to develop the end anchorage of external steel reinforcement of RC slab bridges. External prestress method using the existing steel is that When the anchorage is installed in slab end, a plenty of anchor bolts were required because the only tangential stress of anchor bolt received a tendon force. Then, for this reason, the wide end anchorage was required and the shape was complicate. But this reinforcement method using method that inserts anchor key at concrete surface cut a groove gets big internal force comparing to the anchorage using existing anchor bolt. Furthermore, the number of anchor bolt for installing apparently will be reduced, and the operation will be convenient because a small anchorage of a simple shape will be received a great tendon force.

  • PDF

단경간 일체식교대 교량의 거동에 대한 해석적 연구 (Analytical Investigation on the Behavior of Simple Span Integral Abutment Bridge)

  • 홍정희;정재호;박종면;유성근;윤순종
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.99-106
    • /
    • 2002
  • This paper presents an analytical investigation on the behavior of simple span integral abutment bridge. An integral abutment bridge is a simple span or multiple span continuous deck type bridge having the deck integral with the abutment wall. Although the temperature variation and earth pressure are the major attributor to the total stress in integral abutment bridge, the superstructure has been designed by modeling it as a simple or continuous beam In order to investigate the effect of temperature change and earth pressure on the superstructure of integral bridge, the simple span integral bridge is modeled as a plane frame element. Performing frame analysis, the variations of bending moment and axial force of superstructure due to the various loading combination are investigated with respect to the flexural rigidity of piles, and the bending moment and axial force obtained by frame analysis are compared with the maximum bending moment obtained by conventional design method and initial prestressing force respectively.

  • PDF

2400MPa 단일 강연선이 적용된 포스트텐션 정착 구역 설계에 대한 실험적 연구 (Experimental Analysis of Anchorage Zone Design for Unbonded Post-Tensioned Concrete Beam With 2400MPa Single Tendons)

  • 문상필;노경민;김민숙;이영학
    • 한국공간구조학회논문집
    • /
    • 제20권1호
    • /
    • pp.41-48
    • /
    • 2020
  • In this study, the design of anchorage zone for unbonded post-tensioned concrete beam with single tendons of ultimate strength 2400MPa was evaluated to verify that the KDS 14 20 60(2016) and KHBDC 2010 codes are applicable. The experimental results showed that the bursting force equation of current design codes underestimated bursting stress measured by test, because the KDS 14 20 60(2016) and KHBDC 2010 propose the location of the maximum bursting force 0.5h which is the half of the height of member regardless of stress contribution. Although the allowable bearing force calculated by current design codes was not satisfied the prestressing force, the cracks and failure in anchorage zone was not observed due to the strengthening effect of anchorage zone reinforcement.