• 제목/요약/키워드: prestressed concrete girder

검색결과 302건 처리시간 0.024초

강-콘크리트 혼합거더 접합부의 정적 거동에 관한 연구 (A Study on the Static Behavior of Connection for the Steel-Concrete Hybrid Girder)

  • 김문겸;노병철;김정훈;박현철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.426-429
    • /
    • 2006
  • This paper focuses on the static behavior of prestressed and non-prestressed connections for the steel-concrete hybrid girder. Based on the experimental study, it is found that the girder with non-prestressed connection failed by local concrete failure at the connection area, and the studs are taken out from the concrete. In case of the girder with prestressed joint, the failure of the girder is initiated by the crack at the varying section area. The test results show that the girder with prestressed connection has higher load carrying capacity compare to the girder with non-prestressed connection by 12%. Therefore, the application of prestressing at the concrete-steel connection recommended for the more secure connection.

  • PDF

Camber calculation of prestressed concrete I-Girder considering geometric nonlinearity

  • Atmaca, Barbaros;Ates, Sevket
    • Computers and Concrete
    • /
    • 제19권1호
    • /
    • pp.1-6
    • /
    • 2017
  • Prestressed concrete I-girders are subject to different load types at their construction stages. At the time of strand release, i.e., detensioning, prestressed concrete girders are under the effect of dead and prestressing loads. At this stage, the camber, total net upward deflection, of prestressed girder is summation of the upward deflection due to the prestressing force and the downward deflection due to dead loads. For the calculation of the upward deflection, it is generally considered that prestressed concrete I-girder behaves linear-elastic. However, the field measurements on total net upward deflection of prestressed I-girder after detensioning show contradictory results. In this paper, camber calculations with the linear-elastic beam and elastic-stability theories are presented. One of a typical precast I-girder with 120 cm height and 31.5 m effective span length is selected as a case study. 3D finite element model (FEM) of the girder is developed by SAP2000 software, and the deflections of girder are obtained from linear and nonlinear-static analyses. Only geometric nonlinearity is taken into account. The material test and field measurement of this study are performed at prestressing girder plant. The results of the linear-elastic beam and elastic-stability theories are compared with FEM results and field measurements. It is seen that the camber predicted by elastic-stability theory gives acceptable results than the linear-elastic beam theory while strand releasing.

프리스트레이트 콘크리트 박스거더교량 해석을 위한 매크로요소의 개발 및 유한요소 정식화(1) (Development of Macro Element for the Analysis of Prestressed Concrete Box Girder Bridges)

  • 오병환;이명규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.436-441
    • /
    • 1997
  • A Formulation based on macroelement concept is developed to analysis the prestressed concrete box girder bridges. The proposed method enables to model the arbitrary shapes and boundary conditions of prestressed concrete box girder bridges. The validity of the algoriyhm is demonstrated through comparisons with other results.

  • PDF

매크로요소를 이용한 프리스트레스트 콘크리트 박스거더 교량의 비선형 해석 (Nonlinear Analysis of Prestressed Concrete Box Girder Bridges Using Macro Element)

  • 오병환;이명규
    • 콘크리트학회지
    • /
    • 제11권1호
    • /
    • pp.77-87
    • /
    • 1999
  • 일반적으로 프리스트레스트 콘크리트 박스거더교량의 설계에서는 단순화된 단면에 대하여 탄성이론에 근거하여 설계를 수행하고 있다. 이러한 단순화에 따른 제약조건을 개선하기 위해서 본 연구에서는 변단면의 프리스트레스트 콘크리트 박스거더교량을 해석하기 위한 매크로요소를 사용하였다. 해석프로그램에서 재료 비선형모델을 사용하여 극한하중 해석이 가능하도록 하였다. 또한, 교량의 장기거동을 예측하기 위해서 재료의 시간의존적 해석모델을 프로그램에 적용하여 교량의 장기 거동해석을 수행할 수 있게 하였다. 따라서, 재료비선형 모델과 시간의존 해석을 포함하는 비선형 매크로요소는 임의의 형상을 가진 프리스트레스트 박스거더 교량의 실제적인 거동해석에 유용하게 사용할 수 있을 것으로 사료된다.

Determination of minimum depth of prestressed concrete I-Girder bridge for different design truck

  • Atmaca, Barbaros
    • Computers and Concrete
    • /
    • 제24권4호
    • /
    • pp.303-311
    • /
    • 2019
  • The depth of superstructure is the summation of the height of girders and the thickness of the deck floor. In this study, it is aim to determine the maximum span length of girders and minimum depth of the superstructure of prestressed concrete I-girder bridge. For this purpose the superstructure of the bridge with the width of 10m and the thickness of the deck floor of 0.175m, which the girders length was changed by two meter increments between 15m and 35m, was taken into account. Twelve different girders with heights of 60, 75, 90, 100, 110, 120, 130, 140, 150, 160, 170 and 180 cm, which are frequently used in Turkey, were chosen as girder type. The analyses of the superstructure of prestressed concrete I girder bridge was conducted with I-CAD software. In the analyses AASHTO LRFD (2012) conditions were taken into account a great extent. The dead loads of the structural and non-structural elements forming the bridge superstructure, prestressing force, standard truck load, equivalent lane load and pedestrian load were taken into consideration. HL93, design truck of AASHTO and also H30S24 design truck of Turkish Code were selected as vehicular live load. The allowable concrete stress limit, the number of prestressed strands, the number of debonded strands and the deflection parameters obtained from analyses were compared with the limit values found in AASHTO LRFD (2012) to determine the suitability of the girders. At the end of the study maximum span length of girders and equation using for calculation for minimum depth of the superstructure of prestressed concrete I-girder bridge were proposed.

Prestress and excitation force identification in a prestressed concrete box-girder bridge

  • Xiang, Ziru;Chan, Tommy H.T.;Thambiratnam, David P.;Nguyen, Andy
    • Computers and Concrete
    • /
    • 제20권5호
    • /
    • pp.617-625
    • /
    • 2017
  • Prestress force identification (PFI) is crucial to maintain the safety of prestressed concrete bridges. A synergic identification method has been proposed recently by the authors that can determine the prestress force (PF) and the excitation force simultaneously in prestressed concrete beams with good accuracy. In this paper, the ability of this method in the application with prestressed concrete box-girder bridges is demonstrated. A reasonable assumption is made to capture the similarity of the dynamic behavior of the prestressed concrete box-girder bridge and a beam under a certain loading scenario, and the feasibility of this method for application in a prestressed box-girder bridge is affirmed. A comprehensive laboratory test program is conducted, and the effects of PF, excitation, measuring time and uncertainties are studied. Results show that the proposed method can predict the PF and the excitation force in a prestressed concrete box-girder accurately and has a great robustness against uncertainties.

Effects of concrete strength on structural behavior of holed-incrementally prestressed concrete (H-IPC) girder

  • Han, Man Yop;Kim, Sung Bo;Kang, Tae Heon
    • Advances in concrete construction
    • /
    • 제3권2호
    • /
    • pp.113-126
    • /
    • 2015
  • Holed-Incrementally Prestressed Concrete (H-IPC) girders are designed using the following new design concepts. At first, web openings reduce the self-weight of the girder, and also diffuse prestressing tendon anchorages. The reduced end anchoring forces decrease the web thickness of the end sections. Additionally, precast technology help to improve the quality of concrete and to reduce the construction period at the site. For experimentally verification, two 50 m full-scale H-IPC girders are manufactured with different concrete strength of 55 MPa and 80 MPa. The safety, stiffness, ductility, serviceability and crack development of H-IPC girder are measured and compared with each other for different strengths. Both girders show enough strength to carry live load and good stiffness to satisfy the design criteria. The experimental result shows the advantages of using high strength concrete and adopting precast girder. The test data can be used as a criterion for safety control and maintenance of the H-IPC girder.

연속 프리스트레스트 콘크리트 거더교에서 건조수축과 크리프의 영향 (Shrinkage and Creep Effects on Continuous Prestressed Concrete Girder Bridges)

  • 조선규;윤석구;이종민;최연왕;정지승
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.417-420
    • /
    • 2004
  • The Prestressed concrete girder bridges(PSC girder bridges), consisting of prestressed concrete girders and cast-in-place deck slabs, are sensitive to creep and shrinkage of concrete. Shrinkage and creep produce additional internal forces md deformations in PSC girder bridges. The long-term behavior of the PSC girder bridges depends on time-dependent properties of materials, amount of prestressing, methods and sequences of construction and age at loading. The purpose of this study is to predict the long-term behavior of PSC girder bridge. For this purpose, Computer program for Time-dependent analysis of PSC girder bridge has been developed. thereafter, Time-dependent analysis using developed computer program was carried out about 3-span continuous PSC girder bridges. Various construction timing sequences were used for parametric study.

  • PDF

Wireless Impedance Sensor with PZT-Interface for Prestress-Loss Monitoring in Prestressed Concrete Girder

  • Nguyen, Khac-Duy;Lee, So-Young;Kim, Jeong-Tae
    • 비파괴검사학회지
    • /
    • 제31권6호
    • /
    • pp.616-625
    • /
    • 2011
  • Ensuring the designed prestress force is very important for the safety of prestressed concrete bridge. The loss of prestress force in tendon could significantly reduce load carrying capacity of the structure. In this study, an automated prestress-loss monitoring system for prestressed concrete girder using PZT-interface and wireless impedance sensor node is presented. The following approaches are carried out to achieve the objective. Firstly, wireless impedance sensor nodes are designed for automated impedance-based monitoring technique. The sensor node is mounted on the high-performance Imote2 sensor platform to fulfill high operating speed, low power requirement and large storage memory. Secondly, a smart PZT-interface designed for monitoring prestress force is described. A linear regression model is established to predict prestress-loss. Finally, a system of the PZT-interface interacted with the wireless sensor node is evaluated from a lab-scale tendon-anchorage connection of a prestressed concrete girder.

세장한 고하중 PSC 정착장치의 실험적 연구 (An Experimental Study on a Narrow and High Capacity PSC Anchorage)

  • 전용식;강상훈;진경석;한만엽
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.39-40
    • /
    • 2009
  • 본 연구는 교량의 장경간화와 시공단축을 위하여 전구간이 동일한 단면을 가지며 중공이 있는 중공형 프리캐스트 프리스트레스 콘크리트 분절 거더를 개발하고 실용화하기 위한 정착장치를 개발하기 위함이다.

  • PDF