• 제목/요약/키워드: prestressed concrete beam design

검색결과 95건 처리시간 0.027초

프리스트레스트 프리캐스트 더블 티형보의 최적설계 (Design and Optimization of Prestressed Precast Double-tee Beams)

  • 유승룡;민창식
    • 콘크리트학회논문집
    • /
    • 제11권6호
    • /
    • pp.57-67
    • /
    • 1999
  • Optimization scheme is presented for the design of precast prestressed double-tee beams used as slabs in the parking or market structures. The objective considered is defined by a function that minimizes the hight of the double-tee beam, including the prefabricated element and the concrete topping poured in a second phase. The Sequential Quadratic Programming method is adopted to solve the problem. As an example 12 double-tee beams are designed with the design loads of the current design code of our country. The results from optimization process show that at least 29cm less in overall height than that designed by PCI design handbook. The section determined from the optimization process was refined for practical considerations. A MathCad 7.0 Pro Spreadsheet was prepared to verify all ACI requirements for flexure, shear and deflections. Flexural tests are performed on four full-scale 12.5m prototype models and show that all the specimens are fully comply the flexural strength requirements as specified by ACI 318-95. The present optimization scheme can be used for wider application of the design of precast prestressed double-tee beams with different materials and configurations particularly for in a large scale or for important designs.

Reinforcement design for the anchorage of externally prestressed bridges with "tensile stress region"

  • Liu, C.;Xu, D.;Jung, B.;Morgenthal, G.
    • Computers and Concrete
    • /
    • 제11권5호
    • /
    • pp.383-397
    • /
    • 2013
  • Two-dimensional tensile stresses are occurring at the back of the anchorage of the tendons of prestressed concrete bridges. A new method named "tensile stress region" for the design of the reinforcement is presented in this paper. The basic idea of this approach is the division of an anchor block into several slices, which are described by the tensile stress region. The orthogonal reinforcing wire mesh can be designed in each slice to resist the tensile stresses. Additionally the sum of the depth of every slice defined by the tensile stress region is used to control the required length of the longitudinal reinforcement bars. An example for the reinforcement design of an anchorage block of an external prestressed concrete bridge is analyzed by means of the new presented method and a finite element model is established to compare the results. Furthermore the influence of the transverse and vertical prestressing on the ordinary reinforcement design is taken into account. The results show that the amount of reinforcement bars at the anchorage block is influenced by the layout of the transverse and the vertical prestressing tendons. Using the "tensile stress region" method, the ordinary reinforcement bars can be designed more precisely compared to the design codes, and arranged according to the stress state in every slice.

경량전철 P.S.C BEAM 교 설계 (P.S.C BEAM Bridge Design For Light Rail System)

  • 서석구;이상희;송창희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.352-357
    • /
    • 2000
  • Design criteria of precast prestressed concrete bridge are analysed and design mettled is systemized. As a result. analysis and design program is developed. Parametric study and economic analysis are accomplished. and data base do design section is developed.

  • PDF

8경간 연속화 프리스트레스 거더교의 시공 계측 및 분석 -서울교 확장교량 적용 (Construction Sequence Measurement & Analysis for Continuous 8-span Prestressed Concrete(PSC) Girder Bridge)

  • 조성웅;이원표;임현태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.985-990
    • /
    • 2001
  • The widened Seoul-Bridge is the first continuous 8-span prestressed concrete(PSC) girder bridge in domain. The construction sequence of the bridge consists of S steps in a large way. The measuring in construction stage includes the determination of the allowable fluctuation value of beam stress in each step and the measurement beam stress during prestessing. The measured tendon prestress force was compared with the design value. When it was compared with the analytic result, the difference between the measured stress and the analytic stress was below allowable error. The friction loss and the anchorage slip loss of the tendon prestress force was lower than the design loss value.

  • PDF

Nonlinear shear strength of pre-stressed concrete beams

  • Rahai, Alireza;Shokoohfar, A.
    • Structural Engineering and Mechanics
    • /
    • 제41권4호
    • /
    • pp.441-458
    • /
    • 2012
  • The shear strength is an important factor in the design of prestressed concrete beams. Therefore, researchers have utilized various methods to determine the shear strength of these elements for the design purposes. To evaluate some of the proposed theoretical methods, numerous models of post-tensioned beams with or without vertical prestressing are selected and analyzed using the finite element method and assuming nonlinear behavior for the materials. In this regard the validity of modeling is evaluated based on some tests results. In the second part of the study two beam specimens are built and tested and their load-deformation curve and cracking pattern are studied. The analytical results consist of compressive strut slope and mid span load deflection are compared with some experimental results, and the results of some codes' formulas. Finally comparing the results of nonlinear analysis with the experimental values, a new formula is proposed for determining strut slopes in prestressed concrete beams.

Behaviour and stability of prestressed steel plate girder for torsional buckling

  • Gupta, L.M.;Ronghe, G.N.;Naghate, M.K.
    • Steel and Composite Structures
    • /
    • 제3권1호
    • /
    • pp.65-73
    • /
    • 2003
  • A higher level of engineering standard in the field of construction, is the use of prestressing in building structures. The concept of prestressing steel structures has only recently been widely considered, despite a long and successful history of prestressing concrete members. Several analytical studies of prestressed steel girders were reported in literatures, but much of the work was not studied with reference to the optimal design and behaviour of the prestressed steel plate girder. A plate girder prestressed eccentrically, will behave as a beam-column, which is subjected to axial compression and bending moment which will cause the beam to buckle out. The study of buckling of the prestressed steel plate girder is necessary for stability criteria. This paper deals with the stability of prestressed steel plate girder using concept of "Vlasov's Circle of Stability" under eccentric prestressing force.

프리캐스트 게르버 U형보의 댑 전단 거동평가 (Evaluation on Shear Performance of the Dapped Ends of Precast Gerber′s U-Beams)

  • 박현석;유승룡
    • 콘크리트학회논문집
    • /
    • 제14권4호
    • /
    • pp.492-502
    • /
    • 2002
  • 게르버보의 댑단부는 PCI와 CPCI 배근방법에 의하여 설계하였고, 남은 두 단부는 본 연구에서 고려한 배근방법으로 배근하였다. 본 실험에서 고려한 댑단부의 깊이는 프리캐스트 콘크리트의 깊이 77 cm와 토핑콘크리트의 깊이 18.2 cm를 합한 전체 보깊이의 1/2에 해당한다. 실물크기 게르버 U형보 2개에 대하여 4회의 전단실험을 수행하였다. PCI와 CPCI 설계방법에 의한 모든 시험체는 사용하중의 32 % 이전에 댑 모서리 요각부위에서 초기균열이 발생하였으며, 예상 공칭강도에는 못 미치나 설계강도를 상회하여 종국 파괴되었다. 걸이 철근량을 PCI 요구량보다 증가시킬수록 초기균열 제어에 효과적이었으며, 폭 넓은 균열을 발생시키며 연성적으로 파괴되었고 강도도 증가하였다. CPCI 설계방법에 의한 시험체는 PCI시험체에 비하여 보다 연성적으로 파괴되었다.

Transfer length of 2400 MPa seven-wire 15.2 mm steel strands in high-strength pretensioned prestressed concrete beam

  • Yang, Jun-Mo;Yim, Hong-Jae;Kim, Jin-Kook
    • Smart Structures and Systems
    • /
    • 제17권4호
    • /
    • pp.577-591
    • /
    • 2016
  • In this study, the transfer length of 2400 MPa, seven-wire high-strength steel strands with a 15.2 mm diameter in pretensioned prestressed concrete (PSC) beams utilizing high strength concrete over 58 MPa at prestress release was evaluated experimentally. 32 specimens, which have the variables of concrete compressive strength, concrete cover depth, and the number of PS strands, were fabricated and corresponding transfer lengths were measured. The strands were released gradually by slowly reducing the pressure in the hydraulic stressing rams. The measured results of transfer length showed that the transfer length decreased as the concrete compressive strength and concrete cover depth increased. The number of strands had a very small effect, and the effect varied with both the concrete cover depth and concrete strength. The results were compared to current design codes and transfer lengths predicted by other researchers. The comparison results showed that the current transfer length prediction models in design codes may be conservatively used for 2400 MPa high-strength strands in high-strength concrete beams exceeding 58 MPa at prestress release.

Fatigue Assessment Model of Corroded RC Beams Strengthened with Prestressed CFRP Sheets

  • Song, Li;Hou, Jian
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권2호
    • /
    • pp.247-259
    • /
    • 2017
  • This paper presents a fatigue assessment model that was developed for corroded reinforced concrete (RC) beams strengthened using prestressed carbon fiber-reinforced polymer (CFRP) sheets. The proposed model considers the fatigue properties of the constituent materials as well as the section equilibrium. The model provides a rational approach that can be used to explicitly assess the failure mode, fatigue life, fatigue strength, stiffness, and post-fatigue ultimate capacity of corroded beams strengthened with prestressed CFRP. A parametric analysis demonstrated that the controlling factor for the fatigue behavior of the beams is the fatigue behavior of the corroded steel bars. Strengthening with one layer of non-prestressed CFRP sheets restored the fatigue behavior of beams with rebar at a low corrosion degree to the level of the uncorroded beams, while strengthening with 20- and 30%-prestressed CFRP sheets restored the fatigue behavior of the beams with medium and high corrosion degrees, respectively, to the values of the uncorroded beams. Under cyclic fatigue loading, the factors for the strengthening design of corroded RC beams fall in the order of stiffness, fatigue life, fatigue strength, and ultimate capacity.

가로보를 정착구조로 하는 연속화 PSC 합성거더 시공사례 (A Case Study on Continuous Prestressed Concrete Composite Girder with Cross-beam Anchorage System)

  • 박현묘;허영;김윤환;김석태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.451-452
    • /
    • 2010
  • PSC I 거더교는 시공성, 경제성, 사용성, 안전성 등 모든 면에서 성능이 매우 우수하여 지금까지 가장 많이 건설되어 온 교량형식이다. 그러나, 국내의 경우에는 표준거더의 형고가 높게 설계되어 장지간화에는 제한적이었다. 따라서, 본 논문에서는 가로보 정착구조를 적용하고 다단계 인장기술을 이용한 연속화 PSC거더의 기술을 개발하는데 그 목적을 두었다.

  • PDF