• Title/Summary/Keyword: pressurized MF

Search Result 11, Processing Time 0.027 seconds

Improvement of Pressurized MF Pretreatment in MF/RO Process for Reuse (하수방류수 재이용 MF/RO 공정에서 가압식 MF의 전처리 성능 향상 방안 연구)

  • Na, Yumee;Park, Yong-Min;Lee, Yang-Woo;Kim, Won Kyong;Kim, Ji-Tae;Cho, Il-Hyoung
    • Membrane Journal
    • /
    • v.24 no.5
    • /
    • pp.350-357
    • /
    • 2014
  • Pressurized MF membranes are used to remove suspended solid and colloidal materials of wastewater treatment plant effluent as the pretreatment of RO in reuse water production process. Membrane operation data and pollutants removal efficiency are investigated using 100 t/d scale pilot plant in J wastewater treatment plant located in Namyangju city. 40 LMH flux of pressurized MF membrane are obtained in various turbidity and temperature condition. Coagulation of dissolved organic enables flux improvement of MF from 40 LMH to 60 LMH. Pressure drop of 1st RO elements rapidly increased after long-term pause, which is because the complex contamination of organic matter and ionic substances of pluming systems.

Effect of Coagulated Flocs Broken by the Pressure Pump on Removal Rate and Membrane Fouling of Pressurized MF process (가압펌프에 의해 해체된 플럭이 가압식 막여과 공정의 제거효율 및 막오염에 미치는 영향)

  • Kim, Junhyun;Moon, Baeksu;Park, Jongsu;Cho, Yoonho;Kim, Jinho
    • Membrane Journal
    • /
    • v.23 no.6
    • /
    • pp.460-468
    • /
    • 2013
  • This study reviewed optimum dosage rate of coagulant and ability to remove dissolved organic carbon without sedimentation in conventional water purification plant. It was confirmed that floc formated by pre-treatment process was broken by impeller of booster pump. Optimum dosage rate of coagulant was 4 mg/L (as PACl 17%) for floc formation through blend, coagulation and after passing through the pump when turbidity of raw water was less than 10 NTU. And average removal rate of dissolved organic carbon was 43% at that time. Maximum removal rate of dissolved organic carbon was 48%, even though coagulation rate was increased gradually until 8 mg/L (as PACl 17%). So removal rate of dissolved organic carbon is not much improved even if dosage rage of coagulant increase. TMP of PVDF (polyvinylidene flouride) pressurized MF process without pre-treatment operated at 0.54 bar and TMP of PVDF pressurized MF process with pre-treatment operated at 0.41 bar.

Recovery Increase by Recycling Backwash Residuals in Microfiltration System

  • Yu, Myong-Jin;Pak, Hong-Kyoung;Sung, Il-Wha
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.4
    • /
    • pp.13-21
    • /
    • 2008
  • With the rise in membrane applications, residuals management has become a growing challenge for membrane system. The primary residuals of MF/UF (microfiltration/ultrafiltration) system results from the wastes generated during backwashing. Many regulatory agencies, utilities, and water process engineers are unfamiliar with the characteristics and methods for treatment and disposal of membrane residuals. Therefore, this study was performed to investigate the backwash residuals water quality from the pressurized system with and without pre-coagulation, and to suggest approaches for the backwash residuals treatment. Pressurized MF system was installed at Guui water intake pumping station and operated with raw water taken from the Han River. We compared performances with and without the recycling backwash residuals at flux conditions, 50 LMH and 90 LMH with and without pre-treatment (coagulation). Based on the results, recycling of backwash residuals in pressurized system with pre-coagulation showed applicability of backwash residuals managements. Moreover, the recovery rate also increased up to over 99%.

Comparition of Submerged / Pressurized Type Membrane System by DRF and Long-Term Results in MF Drinking Water Treatment (MF막여과 정수처리에서 장기운전 결과 및 DRF를 이용한 침지식 / 가압식 시스템의 비교 평가)

  • Ha, Keum Ryul;Kim, Kwan Yeop;Kim, Hyo-Sang;Lee, Yong Soo;Song, June Sup;Kim, Chung Hwan;Yeom, Ick Tae;Lee, Yong Hoon;Kim, Hyung Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.79-86
    • /
    • 2008
  • In Korea, most of the drinking water treatment relied upon the availability of the surface water, of which the raw water quality varied significantly by season and location. Therefore, the comparison of two operation modes (Pressurized type and Submerged type membrane system) must be estimated before the long-term establishment of two systems. In this study, two pilot-scale microfiltration systems with the capacity of $50m^3/day$ were installed and operated in two different modes, and the applicability of the system was determined based on the results such as the TMP (Trans-Membrane Pressure) and flux. For quantitatively comparing the two systems, a new concept, DRF (Differential Resistance Fraction) was introduced. The accumulated sum of the permeate after each cycle of chemical cleaning was also used as a tool for the system comparison.

Long Term Operation of Microfiltration as a Pretreatment for Seawater Reverse Osmosis Processes (정밀여과를 이용한 역삼투법 해수담수화 전처리 공정의 장기운전 특성)

  • Kim, Su-Han;Kim, Chung-H.;Kang, Suk-H.;Lim, Jae-L.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.6
    • /
    • pp.735-741
    • /
    • 2010
  • A pilot test was carried out to investigate the long term operation characteristics of Microfiltration (MF) system as a pretreatment for seawater reverse osmosis (SWRO) processes for two years. A commercialized MF module with pressurized operation type was used to filter seawater to remove particles which can foul reverse osmosis (RO) membrane. Silt Density Index (SDI) values of filtered seawater by the MF system were ranged from 0.14 to 1.79, which meet the SDI standard for RO feed water as depicted in previous literatures. Although the tested seawater is quite clean (i.e., dissolved organic cabon (DOC) concentration and turbidity were about 1 mg/l and less than 1 NTU, respectively) enough not to foul the MF membrane, steep increase in trans-membrane pressure (TMP) with a constant flux were observed over a whole operation period. A set of operation and water analysis data implies that the steep increase in TMP was resulted from iron and maganese fouling by the combination of metal corrosion by seawater and oxidation state by aeration and residual chlorine.

Hydrogen production by catalytic decomposition of methane over carbon black catalyst in a fluidized bed on pressurized bench-scale condition (가압유동층 반응기에서 카본블랙 촉매를 이용한 메탄의 촉매분해에 의한 수소제조)

  • Seo, Hyung-Jae;Lee, Seung-Chul;Lee, Gang-In;Han, Gui-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.791-793
    • /
    • 2009
  • Hydrogen has been recognized of the energy source for the future, in terms of the most environmentally acceptable energy source. A pressurized fluidized bed reactor made of carbon steel with 0.076 m I.D. and 1.0 m in height was employed for the thermocatalytic decomposition of methane to produce amount of $CO_2$ - free hydrogen with validity from a commercial point of view. The fluidized bed was proposed for withdrawing of product carbons from the reactor continuously. The methane decomposition rate with the carbon black N330 catalyst was rapidly reached a quasi-steady state and remained for several hour. The methane thermocatalytic decomposition reaction was carried out at the temperature range of 850 - 950 $^{\circ}C$, methane gas velocity of 2.0 $U_{mf}$ and the operating pressure of 1.0 -3.0 bar. Effect of operating parameters such as reaction temperature, pressure on the reaction rates was investigated and predicted the effect of a change in conditions on a chemical equilibrium thermodynamically, according to Le Chatelier's principle.

  • PDF

Influencing Factors on Sensitivity of Pressure Decay Test for Membrane Damage Assessment (막 손상 측정을 위한 압력손실시험의 감도에 영향을 미치는 인자)

  • Lee, Yong-Soo;Kim, Hyung-Soo;Kim, Jong-Oh
    • Membrane Journal
    • /
    • v.27 no.4
    • /
    • pp.367-373
    • /
    • 2017
  • Pressurized membrane module systems, including hollow fiber type of Microfiltration (MF) and Ultrafiltration (UF) membranes are being increasingly used in drinking water treatment due to their high removal efficiency of pathogen. However, when fibers are damaged in pressurized membrane system, the pathogen will be able to penetrate the membrane. Therefore, it is essential to guarantee the regulatory requirements for water quality by an effective on-line or off-line condition integrity monitoring methods. Recently, pressure decay test (PDT) which is one of membrane integrity tests has been reflected to drinking water treatment plants using pressurized membrane module. In this paper, three different method were used to perform PDT and three different sensitivity values were analyzed through experiments. Three types of direct integrity test methods were applied to pressure feed side, filtrate side and bidirectional pressure decay test. The results of these experiments show that the sensitivity was increasing when the volume of pressurized gas was decreasing. The sensitivity is inversely proportional to the gas volume. Furthermore, it is desirable to increase pressure difference between feed side and permeate side in order to achieve higher sensitivity in the PDT by membrane damage.

Removal Characteristics of Organic Matters in Pretreatment and Reverse Osmosis Membrane Processes for Seawater Desalination (해수담수화 전처리 및 역삼투막여과 공정의 유기물 제거특성)

  • Kim, Dong-Kwan;Choi, June-Seok;Lee, Chang-Kyu;Kim, Jinho;Choi, Jeong-Hak;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.7
    • /
    • pp.492-497
    • /
    • 2014
  • This study investigated removal characteristics of organic matters in pretreatment and reverse osmosis (RO) membrane processes for seawater desalination. Also, the influence of the changes in characteristics of organic matters on the membrane fouling was assessed. The pretreatment processes included dual media filtration (DMF), pressurized membrane filtration (MF), and submerged membrane filtration (SMF). Turbidity, UV absorption at 254 nm, dissolved organic carbon, size exclusion chromatography (SEC), fluorescence excitation emission matrix (FEEM), and transparent exopolymer particles (TEP) in raw and processed waters were analyzed. Ions and minerals were not removed by any pretreatment process tested, but were removed over 99% through the RO membrane process. Hydrophobic organics, which can play major role in organic membrane fouling, were relatively readily removed compared with hydrophilic ones. Membrane based pretreatment such as MF and SMF exhibited better removals of organics than conventional DMF. As the levels of organics in pretreated water decreased, the silt density index (SDI) decreased. MF treated water exhibited the lowest SDI value; this is possibly due to the lowest TEP ($0.1-0.4{\mu}m$) concentrations.

Optimum Operating Condition for Micro-Filtration Process as a Seawater Desalination Pretreatment (해수담수화 전처리로서 가압식 MF 공정의 최적 운전조건 도출)

  • Kim, Youngmin;Jang, Jung-Woo;Kim, Jin-Ho;Choi, June-Seok;Lee, Sangho;Kim, Sukwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.9
    • /
    • pp.624-629
    • /
    • 2013
  • The relation between performance maintenance conditions and those cost efficiency was studied to choose an optimum operating condition in the seawater desalination pretreatment system. A hollow fiber microfiltration module, which was developed with domestic technology, was tested with the various operating conditions such as chemically enhanced backwash cycles and design dosages of a cleaning chemical. Transmembrane pressure was measured to investigate membrane fouling status and cleaning degree. In addition, economic analysis was performed to compare water production costs by the operation condition. As a result, The operation mode III, chemically enhanced backwash at once a day with 100 mg/L of sodium hypochlorite (NaOCl) was selected. The concurrent evaluation between membrane filtration performance and its economic analysis will be suitable to choose an efficient optimum condition.

CO2 Methanation Characteristics over Ni Catalyst in a Pressurized Bubbling Fluidized Bed Reactor (가압 기포 유동층 반응기에서의 Ni계 촉매 CO2 메탄화 특성 연구)

  • Son, Seong Hye;Seo, Myung Won;Hwang, Byung Wook;Park, Sung Jin;Kim, Jung Hwan;Lee, Do Yeon;Go, Kang Seok;Jeon, Sang Goo;Yoon, Sung Min;Kim, Yong Ku;Kim, Jae Ho;Ryu, Ho Jeong;Rhee, Young Woo
    • Korean Chemical Engineering Research
    • /
    • v.56 no.6
    • /
    • pp.871-877
    • /
    • 2018
  • Storing the surplus energy from renewable energy resource is one of the challenges related to intermittent and fluctuating nature of renewable energy electricity production. $CO_2$ methanation is well known reaction that as a renewable energy storage system. $CO_2$ methanation requires a catalyst to be active at relatively low temperatures ($250-500^{\circ}C$) and selectivity towards methane. In this study, the catalytic performance test was conducted using a pressurized bubbling fluidized bed reactor (Diameter: 0.025 m and Height: 0.35 m) with $Ni/{\gamma}-Al_2O_3$ (Ni70%, and ${\gamma}-Al_2O_3$30%) catalyst. The range of the reaction conditions were $H_2/CO_2$ mole ratio range of 4.0-6.0, temperature of $300-420^{\circ}C$, pressure of 1-9 bar, and gas velocity ($U_0/U_{mf}$) of 1-5. As the $H_2/CO_2$ mole ratio, temperature and pressure increased, $CO_2$ conversion increases at the experimental temperature range. However, $CO_2$ conversion decreases with increasing gas velocity due to poor mixing characteristics in the fluidized bed. The maximum $CO_2$ conversion of 99.6% was obtained with the operating condition as follows; $H_2/CO_2$ ratio of 5, temperature of $400^{\circ}C$, pressure of 9 bar, and $U_0/U_{mf}$ of 1.4-3.