• 제목/요약/키워드: pressurization rate

검색결과 86건 처리시간 0.026초

T-50 비행시험을 통한 조종실 여압시스템의 설계검증 (Design Verification of Cabin Pressurization System by Flight Test of T-50 Advanced Trainer)

  • 서동연;손원익;오영진;김주형;박성순
    • 한국항공우주학회지
    • /
    • 제34권11호
    • /
    • pp.70-75
    • /
    • 2006
  • 조종실 여압시스템은 압력스케쥴, 압력조절 공차, 정상 및 비정상 작동시의 최대 압력변화율 및 조종실로 유입되는 최대 공기변화량과 같은 설계한계에 적절히 응답하도록 설계하여야 한다. 본 논문에서는 T-50 고등훈련기 조종실 여압시스템에 대한 압력강하 해석과 비행시험결과가 소개되었다. 압력강하 해석을 통하여 여압밸브의 출구면적을 계산한 후 무여압 구간에서의 압력공차를 예측하였다. 예측된 결과를 이용하여 D사의 여압부품을 선정하였고, 예측된 압력공차는 비행시험의 결과와 잘 일치하였다. 결론적으로 비행시험을 통하여 T-50 고등훈련기 여압시스템이 MIL-E-18927 설계기준을 만족하였다

대와류모사를 이용한 연기이동의 연구 I. 제연방식과 배기풍량 (A Study on Smoke Movement by Using Large Eddy Simulation I. Smoke Control Systems and Extraction Flowrate)

  • 박외철
    • 한국안전학회지
    • /
    • 제18권2호
    • /
    • pp.40-45
    • /
    • 2003
  • To evaluate the smoke control systems, the large eddy simulation turbulence model based Fire Dynamics Simulate was applied to a 2m $\times$ 2m $\times$ 2.4m room with an opening. The smoke removal rate was investigated for three different smoke control systems: ventilation, extraction and pressurization. When the opening was closed, the smoke removal rates of the smoke control systems were almost the same as expected. The pressurization system showed a lower smoke removal rate compared with the other two smoke control systems for the room with the opening, and hence the pressurization system might not be efficient for a place with large openings. It was shown that the lower extraction flowrate is, the longer time the ventilation system requires to remove smoke. From these results, the ventilation system is recommended for subway stations where several large openings exist.

정지상태 수용액에서 가압과 냉각속도가 과냉각해소에 미치는 영향 (Effect of Pressurization and Cooling Rate on Dissolution of a Stationary Supercooled Aqueous Solution)

  • 김병선;백종현;홍희기;강채동
    • 설비공학논문집
    • /
    • 제19권12호
    • /
    • pp.850-856
    • /
    • 2007
  • In a supercooled or capsule type ice storage system, aqueous solution (or water) may have trouble with non-uniform dissolution though the system contributes to the simplicity of system and ecological improvement. The non-uniform dissolution increases the instability of the system because it may cause an ice blockage in pipe or cooling part. In order to observe the supercooled state, a cooling experiment was performed with pressurization to an ethylene glycol(EG) 3 mass% solution in stationary state. Also, the effect of the pressurization from 101 to 505 kPa to the dissolution of supercooled aqueous solution was measured with the dissolution time of the supercooled aqueous solution at a fixed cooling rate of brine. At results, the dissolution of supercooled point decreased as the pressure of the aqueous solution in the vessel increased. Moreover, the dissolution point increased as the heat flux for cooling increased.

The Effect of Solution Pressure to the Release in a Supercooled Aqueous Solution

  • Kang, Chae-Dong;Kim, Byung-Seon;Hong, Hi-Ki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권1호
    • /
    • pp.25-31
    • /
    • 2009
  • Supercooled type ice storage system with aqueous solution (or water) may have trouble with non-uniform release of supercooling even though it contributes to the simplicity of system and ecological improvement. The non-uniform release increases the instability of the system because it may cause an ice blockage in pipe or cooling part. In order to suppress the release of the supercooling, a cooling experiment was tried to an ethylene glycol(EG) 3 mass% solution corresponding with pressurization. Also, the frequency ratio of the release of the supercooling was measured to the pressurization from 101 to 505 kPa. At results, the frequency ratio of supercooling release tends to decrease as the pressure of the aqueous solution increased in each cooling rate. Moreover, it tends to decrease as the cooling rate of the solution decreased in each pressure.

Fluid Infiltration Effect on Breakdown Pressure in Laboratory Hydraulic Fracturing Tests

  • Diaz, Melvin B.;Jung, Sung Gyu;Lee, Gyung Won;Kim, Kwang Yeom
    • 지질공학
    • /
    • 제32권3호
    • /
    • pp.389-399
    • /
    • 2022
  • Observations on the influence of the fluid infiltration on the breakdown pressure during laboratory hydraulic fracturing tests, along with an analysis of the applicability of the breakdown pressure prediction for cylindrical samples using Quasi-static and Linear Elastic Fracture Mechanics approaches were carried out. These approaches consider fluid infiltration through the so-called radius of fluid infiltration or crack radius, a parameter that is not a material property. Two sets of tests under pressurization rate controlled and injection rate controlled tests were used to evaluate the applicability of these methods. The difficulty of the estimation of the radius of fluid infiltration was solved by back calculating this parameter from an initial set of tests, and later, the obtained relationships were used to predict breakdown pressures for a second set of tests. The results showed better predictions for the injection rate than for the pressurization rate tests, with average errors of 3.4% and 18.6%, respectively. The larger error was attributed to differences in the testing conditions for the pressurization rate tests, which had different applied vertical pressures. On the other hand, for the tests carried out under constant injection rate, the Linear Elastic Fracture Mechanics solution reported lower errors compared to the Quasi-static solution, with values of 3% and 3.8%, respectively. Moreover, a sensitivity analysis illustrated the influence of the radius of fluid penetration or crack radius and the tensile strength on the breakdown pressure, suggesting a need for a careful estimation of these values. Then, the calculation of breakdown pressure considering fluid infiltration in cylindrical samples under triaxial conditions is possible, although larger data sets are desirable to validate and derive better relations.

대규모 건물의 기밀성능 측정기준 수립에 관한 연구 (Study on the Establishment of Large Building Airtightness Measurement Standards)

  • 이동석;지경환;조재훈
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.117-124
    • /
    • 2014
  • Airtightness standards using fan pressurization method are normally used for measuring small buildings, detached houses, and apartment units. And, it is easy to conduct airtightness measurement through this fan pressurization method. However, it can be difficult to achieve accurate measurement results for the large buildings as the height and volume of the buildings have been increased. In this paper, we studied the principle of airtightness method by fan pressurization. And, we reviewed the measurement process described in ISO 9972, EN 13829, ASTM E779, ATTMA TS 1, CAN/CGSB 149.15, and JIS A 2201. Then, we categorized the methods' items according by air flow rate (Q) and pressure difference(${\Delta}P$). As a result, we made a comparison analysis on the measurement methods appeared in each standards. And, we achieved 5 test conditions about air flow rate and pressure difference to state requirements for large buildings airtightness measurement.

건물의 가압방연시스템 설계를 위한 유동해석에 관한 연구 (Flow Analysis of Building Pressurization System for Smoke Control)

  • 김명배;한용식
    • 한국화재소방학회논문지
    • /
    • 제14권2호
    • /
    • pp.14-20
    • /
    • 2000
  • 건물화재시에 연기에 의한 피난자의 위험을 감소시키고 소방대의 구조활동을 원활히 하기 위하여 건물 외부의 공기를 이용, 건물내부의 일부를 가압하는 가압방연시스템이 이용되고 있다. 본 연구에서는 건물의 가압방연시스템을 설계하기 위하여 건물의 각 요소, 방, 로비, 계단실, 급기샤프트 등을 연결하는 유로를 구성하여 각 요소에서의 압력손실과 유량을 계산할 수 있는 컴퓨터 프로그램을 개발하였다. 본 프로그램을 이용하여 가압용 송풍기의 적절한 용량선정과 송풍기의 용량 최적화를 위한 방안을 강구하였다.

  • PDF

샌드위치 가압을 이용하는 연기제어 시스템의 현장실험 사례 연구 (Case Study of a Field Test for a Smoke Control System Using Sandwich Pressurization)

  • 김정엽;안찬솔
    • 한국화재소방학회논문지
    • /
    • 제30권5호
    • /
    • pp.87-92
    • /
    • 2016
  • 국내에서는 고층 및 복합 건축물이 다수 시공되고 있는 상황에서 화재시 실효성 있는 연기대응 기술의 확립이 요구되고 있으며, 고층 건축물에서 제연설비에 대한 대안으로서 샌드위치 가압을 이용하는 연기제어 시스템의 적용이 확대되고 있다. 샌드위치 가압을 이용하는 연기제어 시스템은 연기확산 방지와 원할한 피난환경 제공을 위해서 적정 층간차압과 이를 위한 급배기 풍량의 설계에 관한 자료가 확보되어야 한다. 본 논문에서는 이러한 연구의 일환으로서 샌드위치 가압을 이용하는 연기제어 시스템이 설치된 실제 건축물에서 수행한 현장실험의 과정과 결과를 제시하였다. 실험에서 화재층의 배기풍량과 상하부층의 급기풍량으로 시간당 6회의 환기횟수를 적용하였으며, 시스템 가동으로 화재층인 12층과 그 상부층인 13층 사이에 약 260 Pa의 압력차가 형성되었다. 이러한 압력차 형성은 피난 및 방화구획에 상당한 영향을 미치므로 이에 대한 추가적인 연구가 필요하다.

연돌효과를 고려한 급기가압 제연시스템의 수치해석 연구 (Numerical Analysis on Pressurization System of Smoke Control in Consideration of Stack Effect)

  • 김정엽
    • 한국화재소방학회논문지
    • /
    • 제27권4호
    • /
    • pp.1-6
    • /
    • 2013
  • 압력차를 이용해서 연기를 제어하는 급기가압 제연시스템의 경우에는 건축물 내의 압력 형성에 영향을 미치는 인자들을 설계에 반영해야 하며, 연돌효과가 중요한 인자 중 하나이다. 본 연구에서는 네트워크 모델 기반의 수치해석적 방법을 이용해서 20층 규모의 건축물 피난계단을 대상으로 연돌효과가 포함된 급기가압 제연시스템의 운전 특성을 분석하였다. 연돌효과만 작용하는 경우와 급기가압 제연시스템만 작용하는 경우 및 연돌효과와 급기가압 제연시스템이 동시에 작용하는 경우의 3가지 조건에 대해서 해석을 수행하였다. 층별로 구획실의 압력과 공기 유량에 대한 상세한 해석결과를 제시하였으며, 연돌효과의 영향을 가시적으로 표현하였다. 한편 연돌효과와 급기가압 효과가 합해진 만큼 계단실의 압력이 상승하는 해석결과와 이에 따른 문제점을 제기하였다.

가압제 토출시 온도강하율에 대한 연구 (Study on Temperature Drop Rate during Pressurant Discharge)

  • 정용갑;홍문근;권오성;김영목
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.116-121
    • /
    • 2006
  • 액체로켓 추진시스템에서 가압시스템은 발사체 추진제 탱크의 얼리지 공간에 제어된 가스를 공급하는 것이다 가압시스템에서 고온 가스 열교환기를 적용하는 데는 가압제의 비용적을 증가시켜 전체 발사체 시스템의 중량을 감소시키는 장점이 있다. 그러므로 가압시스템 성능에 있어서 주목할 만한 개선점은 특히 극저온 시스템에서 얻어질 수 있다. 본 연구에서는 외부 유체와 가압제로 공기와 $CN_2$를 각각 적용하였다. 가압제 토출 특성에 관한 수치 해석은 PTF에서 수행된 실험 결과와 비교되었다. 해석과 실험 결과의 오차는 약 ${\pm}15%$ 이내로 나타났다. 이러한 해석적 접근을 사용하면 액체산소에 잠겨진 극저온 가압제의 온도강하율을 예측할 수 있을 것으로 사료된다.

  • PDF