• Title/Summary/Keyword: pressure-filtration

Search Result 356, Processing Time 0.022 seconds

Diuretic Action of Vasopressin (바소프레신의 이뇨작용)

  • Go, Seok-Tae;Yun, Jae-Gyeong;Yu, Gang-Jun
    • YAKHAK HOEJI
    • /
    • v.40 no.4
    • /
    • pp.468-477
    • /
    • 1996
  • Vasopressin which is an antidiuretic hormone in human body produced the diuretic action in dog. This study was investigated in order to certify the diuretic action and to search out the mechanism of the action on the vasopressin. Vasopressin, when given in a dose of 10.0mU/kg, bolus+1.0mU/kg/min intravenously, exhibited the increase of urine flow(Vol), renal plasma flow(RPF), osmolar clearance (Cosm) and amounts of sodium and potassium excreted in urine ($E_{Na},\;E_K$), the decrease of reabsorption rate of sodium and potassium in renal tubules ($R_{Na},\;R_K$), and then elevated the mean arterial pressure(MAP). Vasopressin given in a increased dose to 30.0mU/kg, bolus+1.0mU/kg/min intravenously elicited the same aspect with that exhibited by a small dose in changes of Vol. and all renal function and potentiated the change rates, whereas this time MAP did not change at all when compared with control value. Vasopressin, when administered into a renal artery, did not induce the changes of Vol and all renal function in experimental (administered) kidney, but increased slightly the Vol, glomerular filtration rate(GFR), $E_{Na},\;and\;E_K$ expected the no change of $R_{Na}\;and\;R_K$ in the control (not administered) kidney. Vasopressin, when infused into carotid artery, showed the increase of Vol. GFR, $E_{Na},\;and\;E_K$ and no change of $R_{Na}\;and\;R_K$ in a dose of 1/5 of intravenous dose. Diuretic action of vasopressin administered into carotid artery was not influenced by renal denervation. Above results suggest that vasopressin produced diuretic action by hemodynamic changes in dogs. These hemodynamic changes may be mediated by central endogenous substances not associated with renal nerve.

  • PDF

Performance of Nano Ceramic Filter for the Removal of Ultra Fine Particles (초미세입자 제거를 위한 나노세라믹 필터의 성능 평가)

  • Kim, Jong-Won;Ahn, Young-Chull;Yi, Byeong-Kwon;Jeong, Hyeon-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.751-756
    • /
    • 2009
  • In the perspective of saving energy in buildings, the high performance of insulation and air tightness for improving the heating and the cooling efficiency, has brought economically positive effects. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and is also very harmful to the residents, because they spend over 90% of their time indoors. Therefore, the ventilation is important to keep the indoor environment clean and it can also save the energy consumption. In this study, a HEPA type nano ceramic filter is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. The double layer filter, which has $30{\mu}m$ in diameter at the conditions of 10wt% of concentration and 3kV/cm of the electric intensity, is produced by electrospinning. The filtration coating technology is confirmed in the solution with $SiO_2$ nano particles using polymer nano fibers. Also double layer filters are coated with $SiO_2$ nano particles and finally the porous construction materials are made by sintering in the electric furnace at $200{\sim}1400^{\circ}C$. The efficiency is measured 96.67% at the particle size of $0.31{\mu}m$, which is slightly lower than HEPA filter. However the efficiency is turned out to be sufficient.

  • PDF

Evaluation on Chemical Cleaning Efficiency of Fouled in $1,000,000m^3/day$ Sea Water Reverse Osmosis Membrane Plant (해수용 역삼투막을 이용한 $1,000,000m^3/day$ 규모의 플랜트에서 오염된 막의 화학세정 효율 평가)

  • Park, Jun-Young;Kim, Ji-Hoon;Jeong, Woo-Won;Nam, Jong-Woo;Kim, Young-Hoon;Lee, Eui-Jong;Lee, Yong-Soo;Jeon, Min-Jung;Kim, Hyung-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.285-291
    • /
    • 2011
  • Membrane fouling is an unavoidable phenomenon and major obstacle in the economic and efficient operation under sea water reverse osmosis (SWRO). When fouling occurs on the membrane surface, the permeate quantity and quality decrease, the trans-membrane pressure (TMP) and operation costs increase, and the membrane may be damaged. Therefore, chemical cleaning process is important to prevent permeate flow from decreasing in RO membrane filtration process. This study focused on proper chemical cleaning condition for Shuaibah RO plant in Saudi Arabia. Several chemical agents were used for chemical cleaning at different contact time and concentrations of chemicals. Also autopsy analysis was performed using LOI, FT-IR, FEEM, SEM and EDX for assessment of fouling. Specially, FEEM analysis method was thought as analyzing and evaluating tool available for selection of the first applied chemical cleaning dose to predict potential organic fouling. Also, cleaning time should be considered by the condition of RO membrane process since the cleaning time depends on the membrane fouling rate. If the fouling exceeds chemical cleaning guideline, to perfectly remove the fouling, certainly, the chemical cleaning is increased with membrane fouling rate influenced by raw water properties, pre-treatment condition and the point of the chemical cleaning operation time. Also choice of cleaning chemicals applied firstly is important.

Ammonia Removal Characteristics in Membrane Contactor System Using Tubular PTFE Membrane (관형 PTFE 분리막을 이용한 막 접촉기(Membrane Contactor) 시스템에서 암모니아의 제거 특성)

  • Ahn, Yong-Tae;Hwang, Yu-Hoon;Shin, Hang-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.5
    • /
    • pp.353-358
    • /
    • 2011
  • In this study, ammonia removal characteristics in membrane contactor system under various operating conditions were evaluated. The mass transfer coefficient was used to quantitatively compare the effect of various operation conditions on ammonia removal efficiency. Effective removal of ammonia was possible with the tubular PTFE membrane contactor system at all tested conditions. Among the various operation parameters, contact time and solution pH showed significant effect on ammonia removal mechanism. Overall ammonia removal rate was not significantly affected by influent suspended solution concentration unlike other pressure driven membrane filtration processes. Also the osmotic distillation phenomena which deteriorate the mass transfer efficiency can be minimized by preheating of strip solution. Membrane contactor system can be a possible alternative to treat high strength nitrogen wastewater by optimizing operation conditions such as stripping solution flow rate, influent wastewater temperature, and influent pH.

A Case of Infantile Nephrotic Syndrome associated with Neuroblastoma

  • Kim, Soo Hyun;Park, Hyun-Min;Lee, Joo Hoon;Kim, Hyery;Go, Heounjeong;Kim, Dae Yeon;Park, Young Seo
    • Childhood Kidney Diseases
    • /
    • v.22 no.2
    • /
    • pp.91-96
    • /
    • 2018
  • Nephrotic syndrome in the first year of life, characterized by renal dysfunction and proteinuria, is associated with a heterogeneous group of disorders. These disorders are often related to genetic mutations, but the syndrome can also be caused by a variety of other diseases. We report an infant with nephrotic syndrome associated with a neuroblastoma. A 6-month-old girl was admitted with a 10% weight loss over 10 days and nephrotic-range proteinuria. She was ill-looking, and her blood pressure was higher than normal for her age. Her cystatin-C glomerular filtration rate was decreased, and levels of plasma renin, aldosterone, and catecholamines were elevated. Renal ultrasonography and abdominal computed tomography showed a retroperitoneal prevertebral mass encasing both renal arteries and the left renal vein. The mass was partially resected laparoscopically, and the pathologic diagnosis was neuroblastoma. Findings on a simultaneous renal biopsy were unremarkable. The patient was treated with chemotherapy and several anti-hypertensive drugs, including an alpha blocker. Two months later, the mass had decreased in size and the proteinuria and hypertension were gradually improving. In an infant with abnormal renin-angiotensin system activation, severe hypertension, and nephrotic-range proteinuria, neuroblastoma can be considered in the differential diagnosis.

Development of ELISA for Brucella abortus RB51 II. Purification of 8kDa antigen and development of ELISA using its antigen of Brucella abortus RB51 (부루세라 RB51의 ELISA 진단법 개발 II. Brucella abortus RB51균의 8kDa 항원 정제 및 ELISA 진단법 개발)

  • Her, Moon;Cho, Dong-hee;Jung, Byeong-yeal;Cho, Seong-kun;Jung, Suk-chan;Kim, Ok-kyung
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.1
    • /
    • pp.51-57
    • /
    • 2001
  • A procedure for extraction and purification of 8 kDa antigen of Brucella abortus RB51 was developed. Bacteria heat inactivated at $60^{\circ}C$, 30 min was extracted by 1% sarcosine and followed by fluid pressure liquid gel filtration chromatography of 2 series, Superose 12 HR 10/30 and Sephacryl S-100. There was produced $71.46{\mu}g/g$(wet) of 8 kDa antigen, and it resisted 1% trypsin, solved 1% triton X-100 higher than distilled water and inactivated 0.1% proteinase K. These results show that 8 kDa antigen may be a lipoprotein existed cell surface of B. abortus RB51. Also, we developed ELISA using purified 8 kDa surface antigen of Brucella abortus RB51 strain, its specificity and sensitivity was 95.0%, 98.6%, respectively. As compared with dot-blot assay using whole cell and ELISA using 8 kDa antigen, its correlation was 93.5%.

  • PDF

Effect of coagaulation on ceramic microfiltration membrane fouling (응집공정이 세라믹 정밀여과막 파울링에 미치는 영향)

  • Hwang, Young Jin;Lim, Jae Lim;Choi, Young Jong;Wang, Chang Gun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.459-469
    • /
    • 2009
  • It is well known that coagulation pretreatment can reduce foulants prior to membrane filtration. The purpose of this research was to investigate the effects of coagulation on fouling of ceramic microfiltration membrane($0.1 {\mu}m$) using pilot plant of $150m^3/day/train$ capacity. Train A membrane system has pretreatment process of ozonation and coagulation while train B has only coagulation. Two types of coagulation operation were investigated: back mixer(rapid mixing with or without slow mixing) which is a conventional mechanically stirred mixer and an inline static mixer. Ozone dose rate for train A was 1 mg/L and ozone contact time was 12 min. The coagulation dose(PACl 10% as $Al_2O_3$) rate was changed 20~40 mg/L according to experimental schedule. In this experimental conditions, the coagulation of back mixer type with rapid mixing(GT=72,000) and slow mixing(GT=45,000) was the best effective in reduction of ceramic membrane fouling regardless preozonation. Especially, the effect of inline static mixer was sensitive to change in water quality. Ozonation mainly affected irreversible fouling rather than reversible fouling in accordance with less adsorption of NOM on the membrane surface. Thus, the increase rate of the nomalized TMP(trans membrane pressure) at $25^{\circ}C$ for train A was relatively lower than that of train B under same coagulation process with same coagulant dosage. The best performance of ceramic membrane appeared in case of combined process with ozonation, therefore this integrated process is able to archive less coagulant dosing and secure a stability of ceramic membrane system.

The Reduction of Waterworks Sludge by Hydrogen Peroxide Treatment (과산화수소 산화처리에 의한 정수슬러지의 감량화)

  • Kwon, Jae-Hyun;Kim, Young-Do;Park, Ki-Young;Lee, Seock-Heon;Kim, II-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.123-130
    • /
    • 2007
  • The effects of hydrogen peroxide treatment on the reduction of waterworks sludge were investigated in this study. Sludge treated by peroxidation $H_2O_2$ oxidation) was dewatered using a pressure filter at 3atm. It was observed that $H_2O_2$ treatment at the acidic condition significantly reduce both cake water content and specific resistance to filtration (SRF), indicating the enhancement of dewaterability and filterability. The filterability by hydrogen peroxide treatment at pH 3.5 was better than acidic treatment and became comparable with polymer conditioning. The sludge filterability evaluated by SRF was optimal at a dose 2ml $H_2O_2$/sludge($0.02g\;H_2O_2/gTS$) after adjusting of pH to 3.5. The $H_2O_2$ oxidation at pH 3.5 also produced even more dewatered cake when compared with polymer conditioning. The reduction rate of sludge mass at an optimal condition showed 34% compared with untreated sludge. The effects of peroxidation on sludge properties including zeta potential, bound water and particle size were also evaluated. Peroxidation at the acidic condition reduced both bound water and zeta potential. By $H_2O_2$ combined with sulfuric acid leached iron caused Fenton's reaction, which showed a potential to significantly reduce the amount of solids mass and to produce more compact cake with higher filterability.

Microalbuminuria in children with urinary tract infection

  • Kwak, Byung-Ok;Chung, So-Chung;Kim, Kyo-Sun
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.9
    • /
    • pp.840-844
    • /
    • 2010
  • Purpose: Microalbuminuria is defined as increased urinary albumin excretion (30-300 mg/day) or microalbumin/creatinine ratio (30-300 mg/g) in a spot urine sample. Although microalbuminuria is a predictor of clinical nephropathy and cardiomyopathy, few studies have investigated microalbuminuria in children with urinary tract infection (UTI). Therefore, we compared the spot urine microalbumin/creatinine ratio in pediatric UTI patients with that of control subjects. Methods: We investigated the correlation between the ratio in children with UTI and age, height, weight, blood pressure, glomerular filtration rate (GFR), hematuria, vesicoureteral reflux, renal parenchymal defect, and renal scar, and its predictability for UTI complications. Results: We studied 66 patients (42 boys, 24 girls) and 52 healthy children (24 boys, 28 girls). The mean microalbumin/creatinine ratio in UTI patients was statistically significantly increased compared to the control group ($340.04{\pm}321.36mg/g$ vs. $225.68{\pm}154.61mg/g$, $P$=0.0141). The mean value of spot urine microalbumin/creatinine ratio ($384.70{\pm}342.22mg/g$ vs. $264.92{\pm}158.13mg/g$, $P$=0.0341) in 1-23 months age patient group showed statistically significant increase compared to control group. Microalbumin/creatinine ratio showed negative correlation to age (r=-0.29, $P$=0.0167), body surface area (BSA) (r=-0.29, $P$=0.0173) and GFR (r=-0.26, $P$=0.0343). The presence of hematuria ($P$=0.0169) was found to be correlated. Conclusion: The spot urine microalbumin/creatinine ratio in children with UTI was significantly greater than that in normal children, and it was positively correlated with GFR. This ratio is a potential prescreening and prognostic marker in UTI patients. Further studies are required to validate the predictability of microalbuminuria in pediatric UTI patients.

A Study on the Priority Order Evaluation of the Water Supply Monitoring Technology Development for the Intelligent Underground Facility Management (지능형 지하시설물관리를 위한 상수도 모니터링 기술개발의 우선순위 평가에 관한 연구)

  • Kim, Jung-Hoon;Yi, Mi-Sook;Han, Jay-Il
    • Spatial Information Research
    • /
    • v.16 no.2
    • /
    • pp.263-278
    • /
    • 2008
  • Nowaday, local governments have planned to manage intelligent underground facilities through the u-City project. But, the intelligent underground facilities are in need of the progressive approach because of the required huge financial resources. Therefore, the objectives of this research are (1) to prioritize the monitoring items of sensing technology developments, (2) to study technological feasibilities, and (3) to discover the killer application which expands ripple effects on economy. To achieve these objectives, final monitoring items were derived from the business analysis of the water supply, the local government survey, the hearing expert opinions and so on. The priority order of final monitoring items were technology developments of (1) the flowmeter flux, (2) the water leakage/crack, (3) the pressure of water supply pipes, and (4) the flux of filtration plants. The research significance is obtained from the derivation and the evaluation of the priority order and the actual demand for the water supply facility management. And, the research results will contribute to the strategic planning for the underground facility intelligence.

  • PDF