• 제목/요약/키워드: pressure-filtration

검색결과 356건 처리시간 0.02초

고지 분말 첨가에 따른 제지 슬러지의 탈수성 개선에 관한 연구 (Study on the Improvement of Paper Sludge Dewatering by Adding Wastepaper Powders)

  • 이성호;임택준;조준형
    • 펄프종이기술
    • /
    • 제34권2호
    • /
    • pp.47-53
    • /
    • 2002
  • Three types of sludges including printing paper, newsprint and tissue paper were prepared at 5% concentration for filtration-expression operations. Filtration-expression characteristics of sludge were measured in different pressure and wastepaper powder dosage. Specific filtration resistance and porosity were calculated with theoretical formula. Higher pressure increased the progresses of filtration and expression while it decreased porosity. The addition of 5% wastepaper powder more accelerated the progresses of filtration and expression than that of 10% wastepaper powder. The lowest porosity value was also measured at 5% dosage of wastepaper powder. The decrease of porosity implied the decrease of moisture content in cake. The results indicated that dewatering of sludge was efficient in high pressure and 5% dosage of wastepaper powder.

DETAILED EXAMINATION OF INVERSE-ANALYSIS PARAMETERS FOR PARTICLE TRAPPING IN SINGLE CHANNEL DIESEL PARTICULATE FILTER

  • Jung, S.C.;Park, J.S.;Yoon, W.S.
    • International Journal of Automotive Technology
    • /
    • 제8권2호
    • /
    • pp.165-177
    • /
    • 2007
  • Predictions of diesel particulate filtration are typically made by modeling of a particle collection, and providing particle trapping levels in terms of a pressure drop. In the present study, a series of single channel diesel particulate filter (DPF) experiments are conducted, the pressure traces are inversely analyzed and essential filtration parameters are deducted for model closure. A DPF filtration model is formulated with a non-linear description of soot cake regression. Dependence of soot cake porosity, packing density, permeability, and soot density in filter walls on convective-diffusive particle transportation is examined. Sensitivity analysis was conducted on model parameters, relevant to the mode of transition. Soot cake porosity and soot packing density show low degrees of dispersion with respect to the Peclet number and have asymptotes at 0.97 and $70\;kg/m^3$, respectively, at high Peclet number. Soot density in the filter wall, which is inversely proportional to filter wall Peclet number, controls the filtration mode transition but exerts no influence on termination pressure drop. The percolation constant greatly alters the extent of pressure drop, but is insensitive to volumetric flow rate or temperature of exhaust gas at fixed operation mode.

연속탈진형 충격기류식 여과집진장치의 여과포 유효탈진거리 예측 (A Study on Prediction of On-line Type Pulse Air Jet Bag Filter Effective Pulsing Distance)

  • 손정삼;서정민;박정호
    • 한국환경과학회지
    • /
    • 제32권8호
    • /
    • pp.555-561
    • /
    • 2023
  • A study is to predict the effective pulsing distance following to the pulsing pressure, nozzle diameter, filtration velocity using numercial analysis techniques and use it as an efficient operation condition and economic data for on-line type pulse air jet bag filter. Filtration area 6 m2 condition, calculate filter resistance coefficient for simulation through the primary experiments using coke dust. For CFD simulation, analysis pulsing characteristics about nozzle diameter, filtration velocity and pulsing pressure. The maximum pulsing length of on-line type pulse air jet bag filter, in 10mm nozzle, filtration velocity 1.5m/min and pulsing pressure 5 bar conditions, is 2,285 mm, maximum length is 76.2% of the total filter bag, which is sufficient to pulsing. In 12mm nozzle, pulsing pressure 5 bar and filtration area 1.22 m2 conditions, the maximum pulsing length of on-line type pulse air jet bag filter is 1,744~2,952 mm, and the maximum length is 2,952 mm indicates pulsing air can be reached to the bottom of filter bag. When the nozzle diameter is increased 8mm to 10mm, maximum pulsing length is extended 40~47%, and increased 10mm to 12 mm, maximum pulsing length is extended 10~17%. For effective pulsing, over the 5bar of pulsing pressure and larger than 10 mm of nozzle diameter are required.

포집량에 따른 p-DPF의 정화효율 및 BPT 특성에 관한 실험적 연구 (An Experimental Study on Filtration Efficiency and BPT Characteristics by PM Loading in Partial-diesel Particulate Filter)

  • 오광철;이경복;이춘범
    • 한국자동차공학회논문집
    • /
    • 제20권1호
    • /
    • pp.147-154
    • /
    • 2012
  • The number of vehicles applied diesel engine are rapidly rising for fuel economy. Accompanying this trend, application of an after-treatment system is strictly required as a result of reinforced emission regulation. The Diesel Particulate Filter (DPF) system is considered as the most efficiency method to reduce particulate matter (PM) by car makers but also in retrofit market. In recently, various kinds of partial flow DPF are widely used for proper filtration performance and reducing of pressure drop but it is difficult to define the characteristics of these filters because the filtration mechanism is obscure according to the status of these systems. In this paper we investigated the characteristics of cell open type DPF according to the status of filter especially, PM loading. The PM loading mass in the p-DPF are predicted from increase of differential pressure of DPF and the trend of filtration efficiency so that we can measure filtration efficiency and Balance Point Temperature (BPT) of this p-DPF according to PM loading.

기계식 부압발생장치를 이용한 매연여과장치의 성능비교 (Performance Comparison of Soot Filtration Apparatus Using a Mechanical Negative Pressure Generating Device)

  • 이한성;김경현;정석호;고대권
    • 동력기계공학회지
    • /
    • 제19권1호
    • /
    • pp.13-18
    • /
    • 2015
  • Over the past years, many research works have been carried out to investigate the factors which govern the performance of diesel engines. The air pollutant emissions from the diesel engines are still significant concerns environmentally in many countries. In the present study, a novel smoke filtration system of diesel engine is proposed. This novel system is composed of filtering elements and vacuum pump driven by exhaust gases emitted from engine cylinders for capturing smoke. In order to verify the excellency of the novel filtration system, the differential pressure across the filtration system is investigated experimentally comparing with other systems which are used commercially in diesel vehicles. As a result it is founded that the differential pressure of the novel system is the smallest among them.

산업용 필터백의 구조에 따른 여과성능 특성 (Filtration Performance Characteristics according to Filter Bag Structure for Application of Industries)

  • 전성민;;이강산;이재랑;김광득;박영옥
    • 한국대기환경학회지
    • /
    • 제32권4호
    • /
    • pp.384-393
    • /
    • 2016
  • In this study, two kinds of industrial filter bags were tested for their filtration performance to apply the existing bag filter systems. Experimental variables were examined for pressure drop, cleaning interval, residual pressure drop, cleaning efficiency, fractional grade efficiency, total collection efficiency according to the filter bag structure. According to these results, the filter bags tested in this study demonstrated good performance in dust collection. This was also true for the double surface filter bag. The lifetime was longer than the round type filter bag because the filtration area was more than 1.6 times wider and the filter quality factor was much higher. Therefore, double surface filter bags are suggested to be used in order to increase filtration performance of the bag filter systems.

포집량에 따른 p-DPF의 정화효율 및 BPT 특성에 관한 실험적 연구 (An Experimental Study on Filtration Efficiency and BPT Characteristics by Soot Loading in Partial-diesel Particulate Filter)

  • 김태권;김영조;하지수;이춘범;오광철
    • 한국자동차공학회논문집
    • /
    • 제19권6호
    • /
    • pp.10-16
    • /
    • 2011
  • Diesel particulate filter is being recognized that it is the most effective technologies to reduce particulate matter. In this study, to determine the characteristics of the cell-open-type pDPF, we employed p-DPF to exhaust gas tunnel of diesel engine and surveyed filtration efficiency and BPT on the basis of PM which is exhausted from engine. In this paper the soot loading mass in DPF can be predicted from increase of differential pressure of DPF so that we can measure filtration efficiency and Balance Point Temperature (BPT) by soot loading mass. The result of the research showed that the filtration efficiency is 65% in ESC mode with 0.7mm hole diameter. For the results of the characteristics of filtration efficiency and BPT according to mass_exh, we found that if mass_exh increases, filtration efficiency increases and BPT decreases.

High-pressure Air Impulse Technique for Rehabilitating Well and Its Application to a Riverbank Filtration Site in Korea

  • Jeon, Hang-Tak;Hamm, Se-Yeong;Cheong, Jae-Yeol;Han, Suk-Jong;Yun, Sul-Min
    • 한국환경과학회지
    • /
    • 제28권10호
    • /
    • pp.887-898
    • /
    • 2019
  • Rehabilitation work is required to increase well productivity, which decreases with the elapsed time of pumping owing to the clogging of the water well. Clogging causes not only a reduction in the well productivity but also a deterioration of the water quality. For unclogging and rehabilitating wells, several techniques are used such as brushing, air surging, surge blocks, and gas impulse. In this study, the high-pressure air impulse technique, which effectively and economically rehabilitates wells, was applied to a riverbank filtration site in Korea for the same objective. At most of the wells, the hydraulic parameters (transmissivity, storage coefficient, and specific capacity) were increased by the application of the high-pressure air impulse technique. The well loss change values also indicate an increase in the hydraulic parameters by the air impulse implementation. Thus, the high-pressure air impulse technique can be efficiently and economically applied to water and riverbank filtration wells for rehabilitating the decreased productivity.

목재펄프 및 비목재 섬유의 여과제 특성에 관한 연구 (Study on Filtration Characteristics of Wood Pulp and Non-Wood Fiber)

  • 조준형;;이범구
    • Journal of the Korean Wood Science and Technology
    • /
    • 제26권4호
    • /
    • pp.86-91
    • /
    • 1998
  • The drainage was used to determine the specific filtration resistance for wood and non-wood fibers. The drainage rate is also affected by factors that can be changed on consistency, pressure drop across the mat, basis weight, additives, and viscosity. Recent development of theoretical studies in flow through porous media and filtration operation emphasize the urgent need for more accurate data for porosity and specific filtration resistance. This study was investigated to determine specific filtration resistance of Hw, Sw-BKP and Kenaf fiber by filtration experimental. Freeness levels selected were 150,250,and $350m\ell$ CSF. The average specific filtration resistance decreased as freeness increased and resistance of Sw-BKP was greater than that of Hw-BKP. The filtrate and porosity increased and specific filtration resistance decreased as particle size of fiber increased.

  • PDF

충격기류식 여과집진기의 내부 유동 시뮬레이션 해석을 통한 압력손실 예측 (Prediction of Pressure Drop Using the Internal Flow Simulation of Pulse Air Jet Bag Filters)

  • 장경민;정은상;서정민
    • 한국환경과학회지
    • /
    • 제29권5호
    • /
    • pp.457-468
    • /
    • 2020
  • With continuous industrial development, the types, and amount of particulate matter (PM) have been increasing. Since 2018, environmental standards regarding PM have become more stringent. Pulse air jet bag filters are suitable for PM under the 20 ㎛ and, can function regardless of size, concentration and type. Filtration velocity and shape are important factors in the operation and design of the pulse air jet bag filters however, few established studies support this theory. In this research, numerical simulations were conducted based on experimental values and, several methods were employed for minimizing the pressure drop. In the pilot system, as the inlet duct velocity was faster than 19 m/sec, flow was not distributed equally and, re-entrainment occurred due to the hopper directional vortex. The multi-inlet system decelerated the hopper directional vortex by 25 ~ 30%, thereby decreasing total pressure drop by 6.6 ~ 14.7%. The guide vane system blocked the hopper directional vortex, which resulted optimal vane angle of 53°. The total pressure of the guide vane system increased by 0.5 ~ 3% at 1.5 m/min conditions. However, the filtration pressure drop decreased by 4.8 ~ 12.3% in all conditions, thereby reducing the operating cost of filter bags.