• 제목/요약/키워드: pressure tube

검색결과 2,124건 처리시간 0.033초

수직 환상관내 반류 공기-물 유동에서 직접분사방식에 따른 플러딩 시작점 특성 (Characteristics of the Onset of Flooding for Countercurrent Air-Water Flow in Vertical Annuli with a Direct Injection Mode)

  • 이상천;신익호;이상무;정모;김동수;장원표
    • 대한기계학회논문집B
    • /
    • 제20권1호
    • /
    • pp.266-274
    • /
    • 1996
  • An experimental work was conducted to investigate the characteristics of the onset of flooding in vertical annuli with a direct injection mode using air and water. The onset of flooding was determined by means of pressure drop measurement while the air velocity was increased gradually under fixed liquid flow rates. Data of the onset of flooding were collected for various combinations of the tube size and the nozzle number. A theoretical analysis of the onset of flooding was also performed based on an envelope theory. The result shows that the onset of flooding in small-scale annuli can be predicted relatively well by the theory. A modified Wallis parameter was used to investigate the scaling effect of flooding phenomena in the annuli, indicating a relatively reasonable result. The number of nozzle has no effect on the flooding velocity when liquid was injected through 2, 3, 4 and 6 nozzles but the initiation of flooding was significantly expedited when 12 nozzles were employed for liquid injection.

DeSOx/DeNOx 효율 개선을 위한 펄스 코로나 방전하에서 기체미립자 전환반응의 적용 (Application of Gas to Particle Conversion Reaction to increase the DeSOx/DeNOx Efficiency under Pulsed Corona Discharge)

  • 최유리;김동주;김교선
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.249-258
    • /
    • 1998
  • In this paper, we investigated the post-combustion removal of nitrogen oxide($NO_x$) and sulfur oxide($SO_x$) which is based on the gas to particle conversion process by the pulsed corona discharge. Under normal pressure, the pulsed corona discharge produces the energetic free electrons which dissociate gas molecules to form the active radicals. These radicals cause the chemical reactions that convert $SO_x$ and $NO_x$ into acid mists and these mists react with $NH_3$ to form solid particles. Those particles can be removed from the gas stream by conventional devices such as electrostatic precipitator or bag filter. The reactor geometry was coaxial with an inner wire discharge electrode and an outer ground electrode wrapped on a glass tube. The simulated flue gas with $SO_x$ and $NO_x$ was used in the experiment. The corona discharge reactor was more efficient in removing $SO_x$ and $NO_x$ by adding $NH_3$ and $H_2O$ in the gas stream. We also measured the removal efficiency of $SO_x$ and $NO_x$ in a cylinder type corona discharge reactor and obtained more than 90 % of removal efficiency in these experimental conditions. The effects of process variables such as the inlet concentrations of $SO_x$, $NH_3$ and $H_2O$, residence time, pulse frequencies and applied voltages were investigated.

  • PDF

뇌졸중 환자의 가정간호중재 프로토콜 개발 (Study on the Development of Home Care Nursing Intervention Protocol for Stroke Patients)

  • 유지수
    • 기본간호학회지
    • /
    • 제7권1호
    • /
    • pp.122-136
    • /
    • 2000
  • Stroke patient needs rehabilitation after receiving an acute treatment in a hospital. When stroke patient gets involved in an early discharge program, home care nurse plays a pivotal role to make them to gain a full strength and to come back to his/her prior life before he/she is sick. In spite of the importance of home care nursing intervention protocol for home care nurses to perform home care nursing autonomously, home care nursing intervention protocol for stroke patient is rarely developed. Therefore this study was conducted to develop home care nursing protocol that is applicable for stroke patients in home care nursing area. 41 home care nursing charts for stroke patients registered in home care nursing agencies from December 1st 1994 to August 31st 1999 at Y hospitals in Seoul and Won-Ju city were analyzed. 44 home care nurses who were having over three years' experience on stroke patients were participated in this study as a user validity validation group. The results of this study are as follows. 1. 28 nursing diagnoses were selected on the basis of evaluation of nursing diagnoses of stroke patients presented in a previous literature and case studies on home care nursing. 2. 17 nursing diagnoses were classified through the frequency analysis of home care nursing charts for 41 stroke patients who had received home care nursing. The order of sequence was like these: impaired skin integrity, risk for infection, nutritional deficit, impaired physical mobility, constipation, knowledge deficit, ineffective airway clearance, anxiety in family members, risk for aspiration, self care deficit, altered urinary elimination, ineffective individual coping, social isolation, risk for injury, self-esteem disturbance, impaired verbal communication, fatigue of family caregiver. 3. Based on validation on expert and user validities, 44 nursing interventions which were above ICV=.80 were chosen. 4. Nursing intervention protocols which showed above ICV=.90 were developed and were like these; pressure ulcer care, position change, preventive care for circulatory dysfunction, tube care : catheter, vital sign monitor, constipation/impaction management, artificial airway management, suction of airway secretion, environmental management : safety, and fall prevention.

  • PDF

원전 종사자의 말단선량평가를 위한 고피폭 접촉 방사선장 특성분석 (An Analysis of Radiation Field Characteristics for Estimating the Extremity Dose in Nuclear Power Plants)

  • 김희근;공태영
    • Journal of Radiation Protection and Research
    • /
    • 제34권4호
    • /
    • pp.176-183
    • /
    • 2009
  • 원전 계획예방정비기간 증기발생기 수실작업 등은 매우 높은 방사선량율을 보이는 지역으로, 짧은 시간 동안 작업으로 종사자는 높은 피폭을 받을 가능성이 있다. 특히, 방사성물질과 접촉작업을 하는 손 부위에서 고피폭이 예상된다. 이런 점을 고려하여 2004년 수행된 국내 원전의 복수선량계 알고리즘 적용성 시험의 TLD 판독결과를 이용하여 고피폭 접촉 작업의 방사선장을 분석하였다. 그 결과, 원전 고피폭 접촉작업의 입사방사선장은 고에너지 광자(High Energy Photon Field)에 의한 피폭으로 해석되었다. 한편 2009년 울진 4호기 계획예방정비기간 S/G 정비작업과 월성 1호기 압력관 교체작업에 참여한 방사선작업종사자에 대해 말단선량 현황과 방사선장을 분석하기위한 현장시험을 실시하였다. 그 결과 입사방사선장은 고에너지 방사선장으로 확인되었다.

PHASE-B PRE-SIMULATION USING BORON AND GADOLINIUM AS POISON IN THE MODERATOR SYSTEM FOR WOLSONG-1

  • Kim, Sung-Min;Kim, Hyeong-Taek;Donnelly, Jim;Marleau, Guy
    • Nuclear Engineering and Technology
    • /
    • 제44권5호
    • /
    • pp.551-560
    • /
    • 2012
  • The Wolsong-1 (W-1) Phase-B pre-simulations were carried out in preparation for tests to be conducted for the restart of the reactor after a major refurbishment project that included replacement of the pressure tube. These pre-simulations for Wolsong-1 Phase-B differ from those in the past that were performed for the Wolsong-1,2,3,4 tests in that these tests use the WIMS/DRAGON/RFSP-IST code suite for verification of the tests and gadolinium instead of the traditional PPV/MULTICELL/RFSP code system and boron as poison in the moderator system. The use of gadolinium is deemed not to have domestically accumulated experience gained from the previous Phase-B tests. Thus, it is appropriate to conduct a study in order to gain a correct understanding and interpretation of potential differences in test results stemming from using gadolinium rather than boron. Although the calibration of the reactivity device will not be noticeably different using boron and gadolinium at a constant moderator temperature, the temperature dependency of the neutronic behavior due to the presence of gadolinium in the moderator system might be pronounced. The results of the pre-simulations using gadolinium revealed that the moderator temperature reactivity coefficients indeed showed significant differences in comparison with those with boron. In order to secure the validity of the analysis results, the newly acquired WIMS/DRAGON/RFSP-IST code suite was verified against the W-2,3,4 Phase-B test results. The results of the new code suite verifications revealed some overall improvements in accuracy; justification of the use of the code can be claimed for the validation of the W-1 Phase-B test results.

Advantages, Disadvantages, Indications, Contraindications and Surgical Technique of Laryngeal Airway Mask

  • Anubhav, Jannu;Ashim, Shekar;Ramdas, Balakrishna;Sudarshan, H.;Veena, G.C.;Bhuvaneshwari, S.
    • 대한두개안면성형외과학회지
    • /
    • 제18권4호
    • /
    • pp.223-229
    • /
    • 2017
  • The beauty of the laryngeal mask is that it forms an air tight seal enclosing the larynx rather than plugging the pharynx, and avoid airway obstruction in the oropharynx. The goal of its development was to create an intermediate form of airway management face mask and endotracheal tube. Indication for its use includes any procedure that would normally involve the use of a face mask. The laryngeal mask airway was designed as a new concept in airway management and has been gaining a firm position in anesthetic practice. Despite wide spread use the definitive role of the laryngeal mask airway is yet to be established. In some situations, such as after failed tracheal intubation or in oral surgery its use is controversial. There are several unresolved issues, for example the effect of the laryngeal mask on regurgitation and whether or not cricoids pressure prevents placement of mask. We review the techniques of insertion, details of misplacement, and complications associated with use of the laryngeal mask. We then attempt to clarify the role of laryngeal mask in air way management during anesthesia, discussing the advantages and disadvantages as well as indications and contraindications of its use in oral and maxillofacial surgery.

관상동맥혈관용 스텐트의 구조해석과 재료설계 (Material Design and Analysis of Coronary Artery Stents)

  • 박중권;강태원;이기성;김태우
    • 한국세라믹학회지
    • /
    • 제44권7호
    • /
    • pp.362-367
    • /
    • 2007
  • Stent is a tiny structure made with either ceramic coating and/or bare metal. Being approximately $1{\sim}2 mm$ in diameter, it consists of holes, slots, or void space and is designed to cover entire medical lesions. Stent implantation into patients' arteries has been practiced for a little more than a decade in order to widen the blocked artery. The adoption of the stent has significantly improved the efficacy when compared with the previous medical practice by balloon angioplasty alone. Yet better biomedical performance of the stent is being demanded in order to eliminate the still existing problem of artery restenosis, which means the artery becomes narrowed again. Recent literature survey shows researches on ceramic coatings onto the stent surface, or material design to improve the mechanical response of the stent. This study focuses more on the material design and mechanical analysis. The results showed that the void configuration within the stent affects the mechanical response significantly. The rectangular shape was found to yield expansion at a relatively lower pressure than the elliptical slot for a slotted tube stent. The present results, when combined with research on coating at the stent surface, may provide stents with improved bio-medical performance.

Ti-Si-Al형 세라믹 촉매 방전관의 오존 발생 특성 연구 (A Study of Ozone Generation Characteristic using Ceramic Catalyst Tube of Ti-Si-Al)

  • 조국희;김영배;이동훈
    • 조명전기설비학회논문지
    • /
    • 제16권6호
    • /
    • pp.130-136
    • /
    • 2002
  • 본 논문은 비유전율이 100 이상으로 제작된 Ti-Si-Al형 세라믹 촉매 방전관에 전원 전압 4 ~6[kV], 구동 주파수0.6~1.0[kHz]를 방전관 전극에 인가하여 오존 농도와 수율을 측정한 것이다. 측정 결과 구동 주파수 600[Hz], 유량 2[1/min], 동작 압력 1.6[atm], 방전관 주위 온도 20[$^{\circ}C$]에서 산소 원료의 경우, 오존 발생 농도는 50~60[g/㎥]이었고, 오존 발생 수율은 180(g/kWh)로 나타났다. 그리고 반응기 내부 온도 또는 유입 가스 온도가 낮을수록 오존 수율은 상승하였다.

A Inclined Slot-excited Circular Plasma Source with a Cusp Magnetic Field

  • You, H.J.;Kim, D.W.;Koo, M.;Jang, S.W.;Jung, Y.H.;Lee, B.J.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.435-435
    • /
    • 2010
  • A inclined slot-excited plasma source is newly designed and constructed for higher flux HNB(Hyperthermal Neutral Beam) generation. The present source is different from the vertical SLAN(SLot ANtenna) sources [1] in two aspects. One is that the slots are inclined, and the other is that the magnetic field is configured to a cusp type. These modifications are intended to make the source plasma operated in sub-milli-torr pressure regime and as thin as possible, both of which is to get higher HNB flux by decreasing the re-ionization rate of the reflected atoms from the neutralizer [2]. The plasma is generated in a quartz tube of internal diameter 170 mm enclosed in a aluminum application chamber of larger diameter 250 mm. The microwave power is fed to the plasma chamber by 8 inclined slots cut into the application chamber wall. The slots are coupled the chamber to a WR280 waveguide wound around it to form a ring resonator. In order to make two slots $\lambda_g/2$ apart in phase, the adjacent slots are rotated in opposite directions. The rotation angle of the slots are set to $60^{\circ}$ from the chamber axis. Between the quartz chamber and the aluminum cylindrical chamber 8 NdFeB magnets are equally spaced and fixed to form the cusp magnetic field confinement and ECR (Electron Cyclotron Resonance) field. In this presentation, the magnetic and electromagnetic simulations, and the measured plasma parameters are given for both the inclined and the vertical slot-excited plasma sources. We also discuss how the sources can be tailored to suit better-performing HNB sources.

  • PDF

음향방출을 이용한 보일러튜브 누설평가 (Leak Detection and Evaluation for Power Plant Boiler Tubes Using Acoustic Emission)

  • 이상국
    • 비파괴검사학회지
    • /
    • 제24권1호
    • /
    • pp.45-51
    • /
    • 2004
  • 발전소 보일러튜브는 장시간 동안 고온고압하의 기혹한 조건으로 운전됨에 따라 크리프, 열피로와 같은 각종 열화에 의해 누설손상이 발생하고 있다. 이러한 누설손상을 실시간 감시하고 진단하기 위하여 음향방출기술을 이용한 현장적용 연구를 수행하였다. 또한 고장예측 진단기술, 튜브의 수명관리 및 설비 감시에 활용할 수 있도록 음향방출 진단시스템을 개발하여 현장에 설치하고, 보일러 운전상태에 따른 신호측정 및 평가, 누설위치 판별 등에 대해 고찰하였다. 누설감지는 저주파 및 고주파대역의 누설로 구분하여 음향방출신호를 각각 측정 및 평가하였다. 현장적용 연구결과로부터 실시간으로 보일러튜브 상태감시와 누설위치 추적이 가능하였으며, 향후 본 기술을 이용하면 발전설비 안전운전과 발전소 정지에 따른 경제적 손실 예방에 크게 기여할 것으로 기대된다.