• Title/Summary/Keyword: pressure tube

Search Result 2,131, Processing Time 0.035 seconds

브란운관의 후면유리 폐기물을 이용한 제올라이트 합성

  • Jang, Yeong-Nam;Bae, In-Guk;Chae, Su-Cheon;Ryu, Gyeong-Won
    • Journal of the Korean Professional Engineers Association
    • /
    • v.34 no.2
    • /
    • pp.167-173
    • /
    • 2001
  • Through alkaline hydrothermal activation processes, Na-A type zeolite was synthesized as a single phase withfunnel-glass waste from a television tube factory. The autoclaving was performed in a closed teflon vessel in therange of 80~95"C. The silica-rich solution as a starting material was hydrothermally synthesized with quartz in INNaOH by heating 350"C under the pressure of 1,500 atm. NaA102 was made from NaOH and Al(OH)3 by heating95"c for 2~3 hours and the molar ratios of it were Na20/A1203=1.4 and H20Ha20=8. The equi-dimensional Atype zeolite (1 ~2 U) was formed by the simple mixing of'the silica-rich solution, glass waste and NaA102 for I~3hours-heating at 80"C. The characterization of the reaction product shows Na-A as a single phase. The synthesizedzeolite has cube-dodecahedral form and Ca2+ ion exchange capacity of the Na-A was in the range of 215~220mequivalent/100 g.20mequivalent/100 g.

Quality Improvement in the Trauma Intensive Care Unit Using a Rounding Checklist: The Implementation Results

  • Chang, Ye Rim;Chang, Sung Wook;Kim, Dong Hun;Yun, Jeongseok;Yun, Jung Ho;Lee, Seok Won;Jo, Han Cheol;Choi, Seok Ho
    • Journal of Trauma and Injury
    • /
    • v.30 no.4
    • /
    • pp.113-119
    • /
    • 2017
  • Purpose: Despite the numerous protocols and evidence-based guidelines that have been published, application of the therapeutics to eligible patients is limited in clinical settings. Therefore, a rounding checklist was developed to reduce errors of omission and the implementation results were evaluated. Methods: A checklist consisting of 12 components (feeding, analgesia, sedation, thromboembolic prophylaxis, head elevation, stress ulcer prevention, glucose control, pressure sore prevention, removal of catheter, endotracheal tube and respiration, delirium monitoring, and infection control) was recorded by assigned nurses and then scored by the staff for traumatized, critically ill patients who were admitted in the trauma intensive care unit (ICU) of Dankook University Hospital for more than 2 days. A total of 170 patients (950 sheets) between April and October 2016 were divided into 3 periods (period 1, April to June; period 2, July to August; and period 3, September to October) for the analysis. Questionnaires regarding the satisfaction of the nurses were conducted twice during this implementation period. Results: Record omission rates decreased across periods 1, 2, and 3 (19.9%, 12.7%, and 4.2%, respectively). The overall clinical application rate of the checklist increased from 90.1% in period 1 to 93.8% in period 3. Among 776 (81.7%) scored sheets, the rates of full compliance were 30.2%, 46.2%, and 45.1% for periods 1, 2, and 3, respectively. The overall mean score of the questionnaire regarding satisfaction also increased from 61.7 to 67.6 points out of 100 points from period 1 to 3. Conclusions: An ICU rounding checklist could be an effective tool for minimizing the omission of preventative measures and evidence-based therapy for traumatized, critically-ill patients without overburdening nurses. The clinical outcomes of the ICU checklist will be evaluated and reported at an early date.

A Study on the Quantitative Measurement of Oil Carry-over in Natural Gas Vehicle fueling Station Using A Gravimetric Method (무게측정법을 이용한 천연가스 자동차 충전소 오일전이 정량 분석에 대한 연구)

  • Hwang, Sung-Soo;Oh, Jun-Seok;Kim, Ki-Dong;Oh, Young-Sam;Choi, Kyung-Sik;Kim, Hack-Eun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.1
    • /
    • pp.12-17
    • /
    • 2015
  • The core of the CNG fueling station is the compressor and most of CNG compressors in Korea require lubrication. Lubrication oil of CNG compressor that can be transferred into the pressure regulators and the engines of fueling system can cause a negative effect on NGV(Nature Gas Vehicle) performance during refueling due to oil Carry-over. In order to avoid the problem, it is necessary to enhance the quality of the compressed natural gas by measuring quantitatively the amount of the transferred oil. In this research, a sampling device and sampling tube were developed, which can be used with a gravimetric method of detection to measure CNG oil Carry-over. In addition, CNG samples were taken at 6 pre-selected CNG fueling stations and analysed for their trace oil Carry-over. The measured total oil Carry-over ranged from 2.569 to 6.509 ppm. This test measurements were compared with those of previous studies to verify the results.

BOND STRENGTH OF RESIN CEMENTS TO ZIRCONIA CERAMIC (지르코니아 세라믹과 레진 시멘트의 결합강도)

  • Chang Mun-Suk;Kim Ji-Hye;Cho Suck-Kyu;Bok Won-Mi;Song Kwang-Yeob;Park Ju-Mi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.426-437
    • /
    • 2005
  • Statement of problem : Although zirconium oxide ceramics are more and more commonly used in restorative dentistry, for many clinical applications only limited data can be found in the literature. However it is quite clear that hydrofluoric acid etching is impossible with zirconia ceramics. Therefore, other bonding techniques are required in order to lute these materials adhesively. Purpose : The purpose or this study was to evaluate the effects of surface treatments on shear bond strengths between two resin cements and a zirconia ceramic. Materials and methods : Experimental industrially manufactured yttrium-oxide-partially-stabilized zirconia ceramic discs (Adens, Korea) were used for this study. The ceramic specimens divided into five experimental groups and a control group (as received). Five surface treatments were studied 1) sandblasting with 110$\mu$m $Al_2O_3$ at 3 bars pressure 13 seconds at a distance of 10 mm, 2) flame-treated with the Silano-Pen for 5 $s/cm^3$, 3) grinding with a diamond bur. 4) sandblasting + Silano-Pen treatment, 5) diamond bur preparation + Silano-Pen treatment. Acrylic plastic tube (5 mm in height and 3 mm in diameter) were filled with composite to fabricate composite cylinders The composite cylinders were bonded to the ceramic specimens with either Superbond C&B or Panavia F resin luting agents. All cemented specimens were tested under shear loading until fracture on universal testing machine at a crosshead speed 1mm/min; the maximum load at fracture was recorded. Sheat bond strength data were analyzed with oneway analysis of variance and Tukey HSD tests (P<.05). Treated ceramic surfaces and fracture surfaces after shear testing were examined morphologically using scanning electron microscope. Results: Ceramic surface treatment with Silano-Pen after sandblasting improved the bond strength of Superbond C&B resin cement. Supevbond C& B resin cement at Silano-Pen aiker sandblasting($27.4{\pm}3.8MPa$) showed statistically higher shear bond strength than the others. Conclusion: Within the limitation of this study, Superbond C& &B resin cement are suitable for cementation of zirconia ceramics and flame-treated with the Silano-Pen after sandblasting is required to enhance the bond strength.

Modeling Study on a Circulatory Hollow-Fiber Membrane Absorber for $CO_{2}$ Separation (이산화탄소 분리를 위한 순환식 중공사 막흡수기에 관한 모델링 연구)

  • Chun, Myung-Suk;Lee, Kew-Ho
    • Membrane Journal
    • /
    • v.5 no.1
    • /
    • pp.35-43
    • /
    • 1995
  • For several years lots of attempts have been made to establish the liquid membrane-based techniques for separations of gas mixtures especially containing carbon dioxide. A more effective system to separate $CO_{2}$ from flue gases, a circulatory hollow-fiber membrane absorber(HFMA) consisting of absorption and desorption modules with vacuum mode, has been considered in this study. Gas-liquid mass transfer has been modeled on a membrane module with non-wetted hollow-fibers in the laminar flow regime. The influence of an absorbent flow rate on the separation performance of the circulatory HFMA can be predicted quantitatively by obtaining the $CO_{2}$ concentration profile in a tube side. The system of $CO_{2}/N_{2}$ binary gas mixture has been studied using pure water as an(inert) absorbent. As the absorbent flow rate is increased, the permeation flux(i.e., defined as permeation rate/membrane contact area) also increases. The enhanced selectivity compared to the previous results, on the other hand, shows the decreasing behavior. It has been found obviously that the permeation flux depends on the variations of pressure in gas phase of desorption module. From an accurate comparison with the results of conventional flat sheet membrane module, the advantageous permeability of this circulatory HFMA can be clearly ascertained as expected. Our efforts to the theoretical model will provide the basic analysis on the circulatory HFMA technique for a better design and process.

  • PDF

A Study on the Diffuser Design of Exhaust Pipes for the Infra-Red Signature Reduction of Naval Ship (함정 적외선 신호 감소를 위한 폐기관의 디퓨져 설계에 관한 연구)

  • Yoon, Seok-Tae;Cho, Yong-Jin;Ko, Dae-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.793-798
    • /
    • 2017
  • In modern naval ships, an infrared signature suppression (IRSS) system is used to reduce the metal surface temperature of the heated exhaust pipe and high-temperature exhaust gases generated from the propulsion system. Generally, the IRSS systems used in Korean naval ships consist of an eductor, mixing tube, and diffuser. The diffuser reduces the temperature of the metal surface by creating an air film due to a pressure difference between the internal gas and the external air. In this study, design variables were selected by analyzing the shapes of a diffuser designed by an advanced overseas engineering company. The characteristics of the design variables that affect the performance of the IRSS were investigated through the Taguchi experimental method. A heat flow analysis technique for IRSS systems established in previous studies was used analyze the performance of the diffuser. The performance evaluation was based on the area-averaged value of the metal surface temperature and exhaust gas temperature at the outlet of the diffuser, which are directly related to the intensity of the infrared signature. The results show that the temperature of the exhaust gas was significantly affected by changes in the diameter of the diffuser outlet, and the temperature of the diffuser's metal surface was significantly affected by changes in the number of diffuser rings.

Performance Evaluation of Underground Pipe with In-Situ Recycled Controlled Low Strength Materials (현장발생토사 재활용 유동성채움재를 이용한 지하매설관의 거동평가)

  • Lee Kwan-Ho;Song Chang-Seob
    • International Journal of Highway Engineering
    • /
    • v.8 no.2 s.28
    • /
    • pp.1-12
    • /
    • 2006
  • An existing Steel pipe, Cast iron pipe and Concrete pipe is can not escaped from aging, specially Metal tube is causing many problems that the quality of water worse is concerned about many rust and mike efficient use of preservation of water. The use of Glassfiber Reinforced Plastic Pipe(GRP PIPE) should be one of the possible scheme to get over these problems. The GRP PIPE has an excellent resistance power and the life is lasting from 50 to 100 years roughly. It's to be useful as a result of high durability and a good construction work also it is a light weight therefore can be expected to short the time of construction and man power. In this research, to executed the small-scaled model test, in-situ model test using CLSM of in-situ soil and to evaluated the stress - strain of the pipe also try to estimated how useful is. From the model test in laboratory, the vertical and horizontal deformation of the GRP PIPE measured in six instance using 200mm and 300mm in diameters. The value of experimentation, theory, analysis got the same results of the test, but the vertical and horizontal deformation gauged in small and the earth pressure was almost zero using CLSM of in-situ soil..

  • PDF

Categorization of Nursing Diagnosis and Nursing Interventions Used in Home Care (가정간호에서 사용된 간호진단과 간호중재 분류)

  • Suh, Mi-Hae;Hur, Hae-Kung
    • Journal of Home Health Care Nursing
    • /
    • v.5
    • /
    • pp.47-60
    • /
    • 1998
  • This study was done to identify basic information in classifying nursing diagnoses and nursing interventions needed for the further development of computerized nursing care plans. Data were collected by reviewing charts of 123 home care clients who had active disease, for whom at least one nursing diagnosis was on the chart, and who had been discharged. Data included demographics, medical orders, nursing diagnoses and nursing interventions. The results of the study, which found the most frequent medical diagnoses to be cancer (40.7%) and brain injury (26.8%), showed that 'Impaired Skin Integrity'(18.3%), 'Risk for Infection'(15.0%), 'Altered Nutrition, Less than Body Requirements'(13.8%), and 'Risk for Impaired Skin Integ rity'(9.9%) were the most frequent nursing diagnoses. 'Pressure Ulcer Care'(28.4%) was the most frequent intervention for 'Impaired Skin Integrity', 'Infection Protection'(16.0%) for 'Risk of Infection', 'Nutrition Counseling'(26.8%) for 'Altered Nutrition' and 'Positioning'(22.0%) for 'Risk for Skin Integrity Impairment', Comparison of interventions with the Nursing Intervention Classification(NIC) showed that the most frequent interventions were in the domain 'Basic Physiological' (33.94%), followed by 'Behavioral'(27.8%), and 'Complex Physiological' (22.6%). Interventions related to teaching family to give care at home could not be classified in the NIC scheme. Examination of the frequency of NIC interventions showed that for the domain 'Activity & Exercise Management', 75% of the interventions were used, but for seven domains, none were used. For the domain 'Immobility Management', 93% of the times that an intervention was used, it was 'Positioning', for the domain 'Tissue Perfusion Management', 'IV Therapy' (59.1%) and for the domain 'Elimination Management', 'Tube Care: Urinary'(54.0%). The nursing diagnoses 'Altered Urinary Elimination' and 'Im paired Physical Mobility' were both used with these clients, but neither 'Fluid Volume Deficit' nor 'Risk of Fluid Volume Deficit' were used rather 'IV Therapy' was an intervention for 'Altered Nutrition, Less than Body Requirements', A comparison of clients with cancer and those with brain injury showed that interventions for the nursing diagnosis 'Impaired Skin Integrity' were more frequent for the clients with cancer, interventions for 'Risk of Infection' were similar for the two groups but for clients with cancer there were more interventions for' Altered Nutrition'. Examination of the nursing diagnoses leading to the intervention 'Positioning' showed that for both groups, it was either 'Impaired Skin Integrity' or 'Risk for Skin Integrity Impairment'. This study identified a need for further refinement in the classification of nursing interventions to include those unique to home care and that for the purposes of computerization identification of the nursing activities to be included in each intervention needs to be done.

  • PDF

Experimental Study of Char Oxidation and Kinetic Rate in O2/CO2 and O2/N2 Environments (O2/CO2조건과 O2/N2조건에서의 촤 연소특성 및 산화 반응성에 관한 실험적 연구)

  • Kim, Song-Gon;Lee, Cheon-Seong;Lee, Byoung-Hwa;Song, Ju-Hun;Chang, Young-June;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1101-1109
    • /
    • 2010
  • We investigated the combustion rate and kinetic rate of char when burning in oxygen-enriched atmospheres with either an $N_2$ or $CO_2$ bath gas in a drop tube furnace. The experiments were performed with sub-bituminous coal (Adaro) and bituminous coal (Coal valley) under atmospheric pressure conditions. Two different coals were investigated over 12 to 30 vol% oxygen and furnace temperatures of 900, 1100, and $1300^{\circ}C$. For both coals, the particle temperature and overall reaction rate are lower in the $CO_2$ bath gas. However, analysis of single-particle data shows that the surface-specific burning rate of char oxidation is similar in both gases. In addition, the kinetic rate and activation energy for each coal were similar for both gases. Generally, the particle temperature and overall reaction rate of sub-bituminous coal are higher than those of bituminous coal.

Development of FURA Code and Application for Load Follow Operation (FURA 코드 개발과 부하 추종 운전에 대한 적용)

  • Park, Young-Seob;Lee, Byong-Whi
    • Nuclear Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.88-104
    • /
    • 1988
  • The FUel Rod Analysis(FURA) code is developed using two-dimensional finite element methods for axisymmetric and plane stress analysis of fuel rod. It predicts the thermal and mechanical behavior of fuel rod during normal and load follow operations. To evaluate the exact temperature distribution and the inner gas pressure, the radial deformation of pellet and clad, the fission gas release are considered over the full-length of fuel rod. The thermal element equation is derived using Galerkin's techniques. The displacement element equation is derived using the principle of virtual works. The mechanical analysis can accommodate various components of strain: elastic, plastic, creep and thermal strain as well as strain due to swelling, relocation and densification. The 4-node quadratic isoparametric elements are adopted, and the geometric model is confined to a half-pellet-height region with the assumption that pellet-pellet interaction is symmetrical. The pellet cracking and crack healing, pellet-cladding interaction are modelled. The Newton-Raphson iteration with an implicit algorithm is applied to perform the analysis of non-linear material behavior accurately and stably. The pellet and cladding model has been compared with both analytical solutions and experimental results. The observed and predicted results are in good agreement. The general behavior of fuel rod is calculated by axisymmetric system and the cladding behavior against radial crack is used by plane stress system. The sensitivity of strain aging of PWR fuel cladding tube due to load following is evaluated in terms of linear power, load cycle frequency and amplitude.

  • PDF