• Title/Summary/Keyword: pressure testing

Search Result 1,067, Processing Time 0.023 seconds

Study on the Measurement of Safety of a High Pressure Vessel (고압용기(高壓容器)의 안전도(安全度) 측정(測定)에 관(關)한 연구(硏究))

  • Yim, Tong-Kyu;Choi, Man-Yong;Han, Eung-Kyo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.2 no.2
    • /
    • pp.9-16
    • /
    • 1983
  • There are two weak points in a high pressure vessel, one is a corner, the other is a crack on the base. In order to evaluate safety of a department of a corner and a crack like a starfish on the base in a high pressure vessel (working pressure: $130kg/cm^{2}$), which was made by Marison's Process, we analyzed stress by strain gauge, measured thickness and hardness by ultrasonic testing, and were able to test pressure by water pressure from nondestructive testing. Also destructive testings were applied to measure thickness and to observe microstructure and chemical composition of a corner on the base. From the results of the experiment, values of experiment were satisfied with a condition of application. But, it is considered that a crack on the base is to be investigated with more by Fracture Mechanics.

  • PDF

ACOUSTIC EMISSION TESTING OF SPHERICAL PRESSURE VESSEL DURING HYDROTESTS (수압시험중(水壓試驗中)의 구행압력용기(球型壓力容器)에 대(對)한 AE검사(檢査))

  • Chang, Hong-Keun;Lee, Joo-Suk;Cho, Kyung-Shik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.3 no.1
    • /
    • pp.12-18
    • /
    • 1983
  • This paper describes the procedures and results of an acoustic emission testing performed during hydrotest of spherical pressure vessel for propane storage. A computer based multi-channel real time monitoring and source location analysis AET-4900 system was used for AE testing. The vessel was extremely quiet throughout the entire test run and especially 6 to $14.5kg/cm^{2}$, it is normal operating pressure range. After exceeding $14.5kg/cm^{2}$, one of the 20 sections showed the most event in any one section 11 total but there were scattered at different locations. In order to confirm the events seen in horizontal weld line of that section, proof testing was performed with ultrasonics and radiography.

  • PDF

Development of Standard Procedures for Local Leakage Rate Testing of Containment Vessel (격납건물 국부누설률시험 표준절차 개발)

  • Moon, Yong-Sig;Kim, Chang-Soo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.8 no.2
    • /
    • pp.42-47
    • /
    • 2012
  • The containment local leakage rate testing in nuclear power plants is performed in accordance with ANSI/ANS 56.8-1994 in Korea. Two methods, the make-up flow rate and the pressure decay, are used for local leakage rate testing. Though ANSI/ANS 56.8-1994 does not define clearly the minimum test duration for the make-up flow rate method, it requires obtaining the data after reaching the stable condition. Thus the prerequisite stable condition for data acquisition and the testing time is differently applied to each NPPs. Therefore, this study presents a standardized test procedure for data stabilization and testing time through experiments to improve the test reliability.

Model and Field Testing of a Heavy-Duty Gas Turbine Combustor

  • Ahn, Kook-Young;Kim, Han-Seok;Antonovsky, Vjacheslav-Ivanovich
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.9
    • /
    • pp.1319-1327
    • /
    • 2001
  • The results of stand and field testing of a combustion chamber for a heavy-duty 150 MW gas turbine are discussed. The model represented one of 14 identical segments of a tubular multican combustor constructed 1:1 scale. The model experiments were executed at a lower pressure than that in a real gas turbine. Combustion efficiency, pressure loss factor, pattern factor, liner wall temperature, flame radiation, fluctuating pressure and NOx emission were measured at partial and full loads for both model and on-site testing. The comparison of these items in the stand and field test results led to has the development of a method of calculation and the improvement of gas turbine combustors.

  • PDF

The Exercise Capacity and Cardiovascular Factors in Patients with Exaggerated Blood Pressure Response during Treadmill Exercise Testing

  • Bae, Hyung-Joon;Shin, Kyung A
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.43 no.4
    • /
    • pp.138-144
    • /
    • 2011
  • Exaggerated blood pressure response during exercise has been found to increase the risk of future hypertension, left ventricular hypertrophy, cerebrovascular stroke, and CVD (cardiovascular disease) death. The aim of this study was to evaluate exercise capacity, cardiovascular factors in exaggerated blood pressure response during treadmill exercise testing. For research subjects, 72 subjects (normal blood response: 49 subjects, exaggerated blood response: 23 subjects) who received treadmill exercise test at J General Hospital were selected in this study. Exaggerated SBP (systolic blood pressure) response was defined as an SBP of 210 mmHg or greater during a maximal treadmill exercise test. The group with an exaggerated SBP response showed significantly higher values for RPP (rate pressure product) compared with the group with a normal SBP response. Subjects with METs (metabolic equivalents) had lower exaggerated SBP response than normal SBP response group. Subjects with recovery SBP had delayed exaggerated SBP response than normal SBP response group. Exaggerated SBP response to exercise is negative correlation with METs.

  • PDF

Effect of horizontal at rest pressure (Po) on elastic modulus from pressuremeter testing

  • Alzubaidi, Radhi M.
    • Geomechanics and Engineering
    • /
    • v.17 no.3
    • /
    • pp.247-252
    • /
    • 2019
  • Modulus of deformation of soil is an essential parameter used for design analysis of foundations, despite its importance; little attention is paid to developing empirical models for predicting the sensitivity of deformation moduli to other parameters that obtained from the pressuremeter tests. Various methods of analysis used to predict the horizontal at rest pressure from pressuremeter testing ($P_o$), these values showed distinctive variations, five methods used to evaluate the values of horizontal at rest pressure, these values been used to evaluate the modulus of elasticity using three methods of analysis. The values of modulus showed distinctive increase when the values of horizontal at rest pressure increase for the same pressuremeter test, these increases may reach to 65%. This sensitivity of the moduli to values of horizontal lead the author to propose some reliable methods of analysis for both the horizontal at rest pressure and the modulus of deformation from pressuremeter testing.

Development of a robust bench-scale testing unit for low-pressure membranes used in water treatment

  • Huang, Haiou;Schwab, Kellogg;Jacangelo, Joseph G.
    • Membrane and Water Treatment
    • /
    • v.2 no.2
    • /
    • pp.121-136
    • /
    • 2011
  • A bench-scale test has recently been proposed as a predictive tool to minimize the scope of pilot-scale testing or to optimize the operation of full-scale membrane filtration systems. Consequently, a bench-scale testing unit was developed for this purpose and systematically evaluated in this study. This unit was capable of accommodating commercially available, low pressure, hollow fiber (LPHF) membranes with various configurations for testing under conditions comparable to real-world applications. Reproducibility of this unit in assessing membrane fouling and microbial removal efficiency of LPHF membranes was tested and statistically comparable results were obtained. This unit serves as a useful apparatus for academic researchers and utilities to evaluate the performance of LPHF membranes used for water treatment.

A Design and Experiment of Pressure and Shape Adaptive Mechanism for Detection of Defects in Wind Power Blade (풍력 발전용 블레이드 접합부의 결함 검출을 위한 일정가압 메커니즘 설계 및 실험)

  • Lim, Sun;Lim, Seung Hwan;Jeong, Ye Chan;Chi, Su Chung;Nam, Mun Ho
    • Journal of Applied Reliability
    • /
    • v.17 no.3
    • /
    • pp.224-235
    • /
    • 2017
  • Purpose: Reliability is the most important factor to detect defects as wind turbines are deployed in large blades. The methods of detecting defects are various, such as non-destructive inspection and thermal imaging inspection. We propose the phased array ultrasonic testing method of non-destructive testing. Methods: We propose the active pressure mechanism for wind power blade. The phase array ultrasonic inspection method is used for fault detection inner blade surface. Controlled pressure of mechanism with respect to z-axis is important for guarantee the result of phase array ultrasonic inspection. The model based control and proposed mechanism are utilized for overall system stability and effectiveness of system. Result: The result of proposed pressure mechanism B is more stable than A. Convergence speed is also faster than A. Conclusion: We confirmed the performance of the proposed constant pressure mechanism through experiments. Non-destructive testing was applied to the specimen to confirm the reliability of detecting defects.

PAUT-based defect detection method for submarine pressure hulls

  • Jung, Min-jae;Park, Byeong-cheol;Bae, Jeong-hoon;Shin, Sung-chul
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.2
    • /
    • pp.153-169
    • /
    • 2018
  • A submarine has a pressure hull that can withstand high hydraulic pressure and therefore, requires the use of highly advanced shipbuilding technology. When producing a pressure hull, periodic inspection, repair, and maintenance are conducted to maintain its soundness. Of the maintenance methods, Non-Destructive Testing (NDT) is the most effective, because it does not damage the target but sustains its original form and function while inspecting internal and external defects. The NDT process to detect defects in the welded parts of the submarine is applied through Magnetic particle Testing (MT) to detect surface defects and Ultrasonic Testing (UT) and Radiography Testing (RT) to detect internal defects. In comparison with RT, UT encounters difficulties in distinguishing the types of defects, can yield different results depending on the skills of the inspector, and stores no inspection record. At the same time, the use of RT gives rise to issues related to worker safety due to radiation exposure. RT is also difficult to apply from the perspectives of the manufacturing of the submarine and economic feasibility. Therefore, in this study, the Phased Array Ultrasonic Testing (PAUT) method was applied to propose an inspection method that can address the above disadvantages by designing a probe to enhance the precision of detection of hull defects and the reliability of calculations of defect size.

A New Stress Path Testing Scheme To Estimate Clay Deformation Characteristics (점성토의 변형특성 평가를 위한 새로운 응력경로시험기법)

  • 최영태;김창엽;정충기
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.303-310
    • /
    • 2000
  • A new stress path testing scheme with back pressure equalization process is proposed, to compute the settlement of clay soils based on their probable deformation mode. The proposed testing scheme minimizes the efforts for testing, otherwise numerous testing works are required to simulate the probable stress paths in the field. Furthermore, the proposed testing scheme can supply anisotropic stress paths for consolidation which cannot be possible in a conventional way. The validity and effectiveness of the proposed testing scheme was investigated and confirmed with test results on remolded kaolinite clay soils. Conclusively, it is suggested that the proposed testing scheme is a very effective tool to compute settlement of clay soils and it is also very useful to investigate the anisotropic characteristics of deformation of clay soils.

  • PDF