• Title/Summary/Keyword: pressure sensitive

Search Result 793, Processing Time 0.027 seconds

Development of Real-time Heart Rate Measurement Device Using Wireless Pressure Sensor (무선 압력센서를 이용한 실시간 맥박수 측정기 개발)

  • Choi, Sang-Dong;Cho, Sung-Hwan;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.5
    • /
    • pp.284-288
    • /
    • 2016
  • Among the various physiological information that could be obtained from human body, heartbeat rate is a commonly used vital sign in the clinical milieu. Photoplethysography (PPG) sensor is incorporated into many wearable healthcare devices because of its advantages such as simplicity of hardware structure and low-cost. However, healthcare device employing PPG sensor has been issued in susceptibility of light and motion artifact. In this paper, to develop the real-time heart rate measurement device that is less sensitive to the external noises, we have fabricated an ultra-small wireless LC resonant pressure sensor by MEMS process. After performance evaluation in linearity and repeatability of the MEMS pressure sensor, heartbeat waveform and rate on radial artery were obtained by using resonant frequency-pressure conversion method. The measured data using the proposed heartbeat rate measurement system was validated by comparing it with the data of an commercialized heart rate measurement device. Result of the proposed device was agreed well to that of the commercialized device. The obtained real time heartbeat wave and rate were displayed on personal mobile system by bluetooth communication.

A Comparative Study on Eigen-Wear Analysis and Numerical Analysis using Algorithm for Adaptive Meshing (마모해석을 위한 고유치해석과 Adaptive Meshing 알고리듬을 이용한 수치해석 비교)

  • Jang, Ilkwang;Jang, Yong Hoon
    • Tribology and Lubricants
    • /
    • v.36 no.5
    • /
    • pp.262-266
    • /
    • 2020
  • Herein, we present a numerical investigation of wear analysis of sliding systems with a constant speed subjected to Archard's wear law. For this investigation, we compared two methods: eigen-wear analysis and adaptive meshing technique. The eigen-wear analysis is advantageous to predict the evolution of contact pressure due to wear using the initial contact pressure and contact stiffness. The adaptive meshing technique in finite element analysis is employed to obtain transient wear behavior, which needs significant computational resources. From the eigen-wear analysis, we can determine the appropriate element size required for finite element analysis and the time increment required for wear evolution by a dimensionless variable above a certain value. Since the prediction of wear depends on the maximum contact pressure, the finite element model should have a reasonable representation of the maximum contact pressure. The maximum contact pressure and wear amount according to this dimensionless variable shows that the number of fine meshes in the contact area contributes more to the accuracy of the wear analysis, and the time increment is less sensitive when the number of contact nodes is significantly larger. The results derived from a two-dimensional wear model can be applied to a three-dimensional wear model.

Flow Visualization of Flowfield Structures around an Aerospike Nozzle using LIF and PSP

  • NIIMI Tomohide;MORI Hideo;TANIGUCHI Mashio
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.75-80
    • /
    • 2004
  • Aerospike nozzles have been expected to be used for an engine of a reusable space shuttle to respond to growing demand for rocket-launching and its cost reduction. In this study, the flow field structures in any cross sections around clustered linear aerospike nozzles are visualized and analyzed, using laser induced fluorescence (LIF) of nitrogen monoxide seeded in the carrier gas of nitrogen. Since flow field structures are affected mainly by pressure ratio, the clustered linear aerospike nozzle is set inside a vacuum chamber to carry out the experiments in the wide range of pressure ratios from 75 to 200. Flow fields are visualized in several cross-sections, demonstrating the complicated three-dimensional flow field structures. Pressure sensitive paint (PSP) of PtTFPP bound by poly- IBM -co-TFEM is also applied to measurement of the complicated pressure distribution on the spike surface, and to verification of contribution of a truncation plane to the thrust. Finally, to examine the effect of the sidewalls attached to the aerospike nozzle, the flow fields around the nozzle with the sidewalls are compared with those without sidewalls.

  • PDF

Vasorelaxant and hypotensive effects of trazodone in Guinea pig (기니픽에서 trazodone의 혈관 이완 및 혈압 하강 효과)

  • Kim, Shang-Jin;Kang, Hyung-Sub;Kim, Jin-Shang
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.4
    • /
    • pp.485-493
    • /
    • 2005
  • We studied the effects of trazodone on arterial blood pressure in anesthesized guinea pigs, and on vascular responses in isolated thoracic aorta. Trazodone produced a concentration-dependent relaxation in phenylephrine-precontracted endothelium intact (+E) rings, but not in a KCl-precontracted aortic rings. These relaxant effects of trazodone on +E rings were significantly greater than those on denuded (-E) rings. The trazodone-induced relaxation was suppressed by glibenclamide and tetrabutylammonium, but not by N(G)-nitro-L-arginine (L-NNA), N(omega)-nitro-L-arginine methyl ester (L-NAME), methylene blue (MB), nifedipine, indomethacin, 2-nitro-4-carboxyphenyl-n,n-diphenylcarbamate (NCDC) and clotrimazole. In vivo, infusion of trazodone elicited a significant decrease in arterial blood pressure. Trazodone-induced blood pressure lowering was markedly inhibited by intravenous pretreatment of prazosin but not by pretreatment of saponin, L-NNA, L-NAME, MB, nifedipine, glibenclamide, clotrimazole and NCDC. In addition, trazodone produced an increase in twitch force of isolated papillary muscle and left ventricular pressure of perfused heart. These findings suggest that the endothelium-independent vasorelaxant effect of trazodone may be explained by activation of $Ca^{2+}$-activated and ATP-sensitive $K^+$ channels, and the hypotensive effect of trazodone is not associated with cardiac contraction.

Sensitivity Analysis of Fabrication Parameters for Dry Process Fuel Performance Using Monte Carlo Simulations

  • Park Chang Je;Song Kee Chan;Yang Myung Seung
    • Nuclear Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.338-345
    • /
    • 2004
  • This study examines the sensitivity of several fabrication parameters for dry process fuel, using a random sampling technique. The in-pile performance of dry process fuel with irradiation was calculated by a modified ELESTRES code, which is the CANDU fuel performance code system. The performance of the fuel rod was then analyzed using a Monte Carlo simulation to obtain the uncertainty of the major outputs, such as the fuel centerline temperature, the fission gas pressure, and the plastic strain. It was proved by statistical analysis that for both the dry process fuel and the $UO_2$ fuel, pellet density is one of the most sensitive parameters, but as for the fission gas pressure, the density of the $UO_2$ fuel exhibits insensitive behavior compared to that of the dry process fuel. The grain size of the dry process fuel is insensitive to the fission gas pressure, while the grain size of the $UO_2$ fuel is correlative to the fission gas pressure. From the calculation with a typical CANDU reactor power envelop, the centerline temperature, fission gas pressure, and plastic strain of the dry process fuel are higher than those of the $UO_2$ fuel.

Comparison of the Characteristics of Metal Membrane Pressure Sensors Depending on the Shape of the Piezoresistive Patterns (금속 멤브레인 압력 센서에서 압저항체 패턴 형태에 따른 특성 비교)

  • Jun Park;Chang-Kyu Kim
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.173-178
    • /
    • 2024
  • Development of pressure sensors for harsh environments with high pressure, humidity, and temperature is essential for many applications in the aerospace, marine, and automobile industries. However, existing materials such as polymers, adhesives, and semiconductors are not suitable for these conditions and require materials that are less sensitive to the external environment. This study proposed a pressure sensor that could withstand harsh environments and had high durability and precision. The sensor comprised a piezoresistor pattern and an insulating film directly formed on a stainless-steel membrane. To achieve the highest sensitivity, a pattern design method was proposed that considered the stress distribution in a circular membrane using finite element analysis. The manufacturing process involved depositing and etching a dielectric insulating film and metal piezoresistive material, resulting in a device with high linearity and slight hysteresis in the range of a maximum of 40 atm. The simplicity and effectiveness of this sensor render it a promising candidate for various applications in extreme environments.

Non-Gaussian time-dependent statistics of wind pressure processes on a roof structure

  • Huang, M.F.;Huang, Song;Feng, He;Lou, Wenjuan
    • Wind and Structures
    • /
    • v.23 no.4
    • /
    • pp.275-300
    • /
    • 2016
  • Synchronous multi-pressure measurements were carried out with relatively long time duration for a double-layer reticulated shell roof model in the atmospheric boundary layer wind tunnel. Since the long roof is open at two ends for the storage of coal piles, three different testing cases were considered as the empty roof without coal piles (Case A), half coal piles inside (Case B) and full coal piles inside (Case C). Based on the wind tunnel test results, non-Gaussian time-dependent statistics of net wind pressure on the shell roof were quantified in terms of skewness and kurtosis. It was found that the direct statistical estimation of high-order moments and peak factors is quite sensitive to the duration of wind pressure time-history data. The maximum value of COVs (Coefficients of variations) of high-order moments is up to 1.05 for several measured pressure processes. The Mixture distribution models are proposed for better modeling the distribution of a parent pressure process. With the aid of mixture parent distribution models, the existing translated-peak-process (TPP) method has been revised and improved in the estimation of non-Gaussian peak factors. Finally, non-Gaussian peak factors of wind pressure, particularly for those observed hardening pressure process, were calculated by employing various state-of-the-art methods and compared to the direct statistical analysis of the measured long-duration wind pressure data. The estimated non-Gaussian peak factors for a hardening pressure process at the leading edge of the roof were varying from 3.6229, 3.3693 to 3.3416 corresponding to three different cases of A, B and C.

COLLAPSE PRESSURE ESTIMATES AND THE APPLICATION OF A PARTIAL SAFETY FACTOR TO CYLINDERS SUBJECTED TO EXTERNAL PRESSURE

  • Yoo, Yeon-Sik;Huh, Nam-Su;Choi, Suhn;Kim, Tae-Wan;Kim, Jong-In
    • Nuclear Engineering and Technology
    • /
    • v.42 no.4
    • /
    • pp.450-459
    • /
    • 2010
  • The present paper investigates the collapse pressure of cylinders with intermediate thickness subjected to external pressure based on detailed elastic-plastic finite element (FE) analyses. The effect of the initial ovality of the tube on the collapse pressure was explicitly considered in the FE analyses. Based on the present FE results, the analytical yield locus, considering the interaction between the plastic collapse and local instability due to initial ovality, was also proposed. The collapse pressure values based on the proposed yield locus agree well with the present FE results; thus, the validity of the proposed yield locus for the thickness range of interest was verified. Moreover, the partial safety factor concept based on the structural reliability theory was also applied to the proposed collapse pressure estimation model, and, thus, the priority of importance of respective parameter constituting for the collapse of cylinders under external pressure was estimated in this study. From the application of the partial safety factor concept, the yield strength was concluded to be the most sensitive, and the initial ovality of tube was not so effective in the proposed collapse pressure estimation model. The present deterministic and probabilistic results are expected to be utilized in the design and maintenance of cylinders subjected to external pressure with initial ovality, such as the once-through type steam generator.

Stretch-activated $K^+$ Channels in Rat Atrial Myocytes

  • Youm, Jae-Boum
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.7 no.6
    • /
    • pp.341-348
    • /
    • 2003
  • Mechanical stimuli to the cardiac myocytes initiate many biochemical and physiological events. Stretch-activated cation channels have been suggested to mediate these events. In this study, cell-attached and inside-out excised-patch clamp methods were used to identify stretch-activated cation channels in adult rat atrial myocytes. Channel openings were increased in cell-attached configuration when negative pressure was applied to the pipette, and also in inside-out excised patches by negative pressure. The channel was not permeable to $Cl^-$, $Na^+$ and $Cs^+$, but selectively permeable to $K^+$, and the degree of activation was dependent on the magnitude of negative pressure (full activation at ${\sim} -50 mmHg). In symmetrical 140 mM KCl, the slope conductance was $51.2{\pm}3$ pS between the potentials of -80 and 0 mV and $55{\pm}6$ pS between 0 and +80 mV (n=5). Glibenclamide ($100{mu}M$) or ATP (2 mM) failed to block the channel openings, indicating that it is not ATP-sensitive $K^+$ channel. Arachidonic acid ($30{mu}M$), which has been shown to activate a $K^+$ channel cooperatively with membrane stretch, did not affect the channel activity. $GdCl_3$ ($100{mu}M$) also did not alter the activity. These results demonstrate that the mechanical stretch in rat atrial myocytes activates a novel $K^+$-selective cation channel, which is not associated with other $K^+$ channels such as ATP-sensitive and arachidonic acid-activated $K^+$ channel.

A Study on Changes in Biomechanical Characteristics of the Foot with Respect to Wedge-type Insole Thickness (키높이 인솔두께에 따른 족부의 생체역학적 특성변화에 대한 연구)

  • Park, T.H.;Jung, T.G.;Han, D.W.;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.80-90
    • /
    • 2013
  • Recently, functional insoles of wedge-type it is for the young to raise their height inserted between insole and heel cause foot pain and disease. Additionally, these have a problem with stability and excessively load-bearing during gait like high-heel shoes. In this study, we compared the changes in biomechanical characteristics of foot with different insole thickness then we will utilize for the development of the insole with the purpose of relieving the pain and disease. Subjects(male, n = 6) measured COP(center of pressure) and PCP(peak contact pressure) on the treadmill(140cm/s) using F-scan system and different insole thickness(0~50 mm) between sole and plantar surface during gait. Also, we computed changes of stresses at the foot using finite element model with various insole thickness during toe-off phase. COP moved anterior and medial direction and, PCP was increased at medial forefoot surface, $1^{st}$ and $2^{nd}$ metatarsophalangeal, ($9%{\uparrow}$) with thicker insoles and it was show sensitive increment as the insole thickness was increased from 40 mm to 50 mm. Change of the stress at the soft-tissue of plantar surface, $1^{st}$ metatarsal head represents rapid growth($36%{\uparrow}$). Also, lateral moments were increased over the 100% near the $1^{st}$ metatarsal as the insole thickness was increased from 0 mm to 30 mm. And it is show sensitive increment as the insole thickness changed 10 mm to 20 mm. As a result, it was expected that use of excessively thick insoles might cause unwanted foot pain at the forefoot region. Therefore, insole thickness under 30 mm was selected.