• Title/Summary/Keyword: pressure recovery distance

Search Result 16, Processing Time 0.031 seconds

Design of Multistage Orifices for PIC System in Nuclear Reactor (원자로 압력 및 체적제어계통의 다단 오리피스 설계)

  • Shin, J.C.
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.17-21
    • /
    • 2015
  • Restriction orifices in the feed and bleed circuit of nuclear power plant are designed using computer program capable of handling multiple hole cascade orifice assembly. Single hole stages of orifice assembly are alternated with multihole stages where necessary. The distance between stages is such that it allows full pressure recovery. The minimum static pressure is higher than vapor pressure at the operating temperature so that cavitation does not occur. Piping sizes are reviewed and increased if necessary to improve rigidity.

A Performance Study of Vent Mixer with Geometric Characteristics in Supersonic Flow (초음속 유동 내 벤트 혼합기의 형상적 특성에 따른 성능 연구)

  • Kim, Chae-Hyoung;Jeung, In-Seuck
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.1
    • /
    • pp.69-75
    • /
    • 2009
  • This paper studies the aerodynamic performance that the vent mixer-new conceptual supersonic mixer-showed with its geometric characteristics. The hole is 2 mm with 2 mm's distance from the wall in case 1 and with no distance in case 2. In case 3 die hole is 1 mm. Case 1 and case 2 showed the same total pressure recovery ratio, of which the case 3 was lower than that. While cases 1-3 had the same reattachment length, the shear layer was thicker in cases 1 and 2 than in case 3. Within the recirculation zone, cases 1 and 2 had lower pressure loss and higher velocity gradient difference than case 3-they enhance mixing between air and fuel. Separation bubble which is developed by the inflow into the recirculation zone has a significant effect on the total pressure recovery ratio in the combustor. Also separation bubble influences pressure distributions and recirculation flows in the recirculation zone. Therefore, inflow rate of air into the recirculation zone mainly affects the performance of vent mixer.

Net Center of Pressure Analysis during Gait Initiation Patient with Hemiplegia : a pilot study (편마비 환자의 보행시작 시 총 압력중심 변화 : 사전연구)

  • Hwang, S.H.;Park, S.W.;Choi, H.S.;Kim, Y.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.1
    • /
    • pp.50-55
    • /
    • 2010
  • Gait initiation is a transitional process from the balanced upright standing to the beginning of steady-state walking. Dysbalanced gait initiation often causes stroke patients to fall. The net center of pressure, measured by two triaxial force plates from twenty healthy subjects and two stroke patients, was investigated to assess asymmetry of gait initiation in hemiparetic subjects. The time interval and distance of the net center of pressure(CoP) moved from the initiation point to the toe off(S1) and from the toe off to the initial contact(S2) were calculated during gait initiation of normal and stroke patients. When the patient with right hemiplegia(A) initiated his gait with right foot, the time interval and the distance of the net CoP in S1 and S2 were smaller than that of normal subjects' values. However, he initiated the gait with left foot(unaffected side) the time interval and the distance of net CoP in S1 were larger than normative values. Differently, the patient with left hemiplegia(B) has shown that larger time interval and distance in S1 and smaller time interval and distance in S2 in both sides. His asymmetry(with which side the gait initiated) was not significant. It is too early to conclude that these results could be general characteristics of the stroke patients because the variations were large and moreover, the level of motor recovery of the patients was different. However, it is expected that these trials could help to set up the strategy of the therapy for the rehabilitation or prevention of fall in stroke patients.

Study on the distribution law and influencing factors of pressure field distribution before exploitation in heavy oilfield

  • Zhang, Xing;Jiang, Ting T.;Zhang, Jian H.;Li, Bo;Li, Yu B.;Zhang, Chun Y.;Xu, Bing B.;Qi, Peng
    • Geomechanics and Engineering
    • /
    • v.18 no.2
    • /
    • pp.205-213
    • /
    • 2019
  • A calculation model of reservoir pressure field distribution around multiple production wells in a heavy oil reservoir is established, which can overcome the unreasonable uniform-pressure value calculated by the traditional mathematical model in the multiwell mining areas. A calculating program is developed based on the deduced equations by using Visual Basic computer language. Based on the proposed mathematical model, the effects of drainage rate and formation permeability on the distribution of reservoir pressure are studied. Results show that the reservoir pressure drops most at the wellbore. The farther the distance away from the borehole, the sparser the isobaric lines distribute. Increasing drainage rate results in decreasing reservoir pressure and bottom-hole pressure, especially the latter. The permeability has a significant effect on bottom hole pressure. The study provides a reference basis for studying the dynamic pressure field distribution before thermal recovery technology in heavy oilfield and optimizing construction parameters.

Numerical Analysis of Flow Characteristics of a Twin-skeg Container Ship with Variation of Stern Hull Shape (쌍축 컨테이너선의 선미선형 변화에 따른 유동 특성에 대한 수치해석)

  • Kim, Hee-Taek;Van, Suak-Ho;Kim, Hyoung-Tae
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.44 no.6
    • /
    • pp.551-563
    • /
    • 2007
  • Numerical analysis for flow characteristics of a twin skeg container ship was carried out according to skeg vertical angles($0^{\circ}$, $10^{\circ}$, $20^{\circ}$) and skeg distances(16m, 20m, 24m) by using a commercial CFD code, FLUENT. Computed: pressure distributions, wake distributions and resistance coefficients have been compared with experimental and WAVIS results carried out by MOERI. Flow characteristics from numerical analysis such as nominal wake fractions, wake distribution and directions of the transverse vectors give good agreement with WAVIS results, even though there are quantitative discrepancy comparing with experimental measurements at the propeller plane. It is found that the better resistance performance can be obtained with the increase of the skeg vertical angle and the decrease of the skeg distance, which are mainly caused by viscous pressure resistance due to the skeg form and pressure recovery around the skeg. In addition, a vertical angle of the skeg gives more effect to the resistance coefficient comparing with the skeg distance. On the basis of results of the present study, it shows that numerical analysis using the commercial code, FLUENT, is useful and efficient tool for the evaluation of the complex stern hull form with twin-skegs.

Crucible Cover of Multilayer Porous Hemisphere for Cd Distillation

  • Kwon, S.W.;Lee, Y.S.;Jung, J.H.;Kim, S.H.;Lee, S.J.;Hur, J.M.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2018.05a
    • /
    • pp.57-57
    • /
    • 2018
  • The electrorefining process is generally composed of two recovery steps in pyroprocessing - the deposit of uranium onto a solid cathode and the recovery of the remaining uranium and TRU elements simultaneously by a liquid cadmium cathode. The liquid cathode processing is necessary to separate cadmium from the actinide elements since the actinide deposits are dissolved or precipitated in a liquid cathode. Distillation process was employed for the cathode processing. It is very important to avoid a splattering of cadmium during evaporation due to the high vapor pressure. In this study, a multi-layer porous round cover was proposed and examined to develop a splatter shield for the Cd distillation crucible. Cadmium vapor can be released through the holes of the shield, whereas liquid drops can be collected in the multiple hemisphere. The collected drops flow on the round surface of the cover and flow down into the crucible. The crucible cover was fabricated and tested in the Cd distiller. The cover was made with three stainless steel round plates with a diameter of 33.50 mm. The distance between the hemispheres and the diameter of the holes are 10 and 1 mm, respectively. About 40 grams of Cd and about 4 grams of Bi was distilled at a reduced pressure for two hours at $470^{\circ}C$. After the Cd distillation experiment, cadmium was not detected and more than 90 % of Bi remained in the ICP-OES analysis. Therefore the crucible cover can be a candidate for the splatter shield of the Cd distillation crucible. Further development of the crucible cover is necessary for the decision of the optimum cover geometry and the operating conditions of the Cd distiller.

  • PDF

Present and Prospect of Ocean Observation Using Pressure-recording Inverted Echo Sounder (PIES) (압력측정 전도음향측심기(PIES)를 활용한 해양관측의 현재와 전망)

  • CHANHYUNG JEON;KANG-NYEONG LEE;HAJIN SONG;JEONG-YEOB CHAE;JAE-HUN PARK
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.28 no.1
    • /
    • pp.51-61
    • /
    • 2023
  • Sound can travel a long distance in the ocean; hence, acoustic instruments have been widely used for ocean observations in various fields such as bathymetric survey, object detection, underwater communication, and current measurements. Herein we introduce a pressure-recording inverted echo sounder (PIES) which is one of the most powerful instruments, moored at seafloor for ocean observation in physical oceanography. The PIES can measure various kinds of oceanic phenomena (currents, mesoscale eddies, internal waves, and sea surface height variabilities) and support acoustic telemetry and pop-up data shuttle (PDS) system for remote data acquisition. In this paper, we review uses of PIES and describe present and prospective system of PIES including remote data acquisition toward (quasi) real-time data recovery.

The effect of hip abductor fatigue on static balance and gait parameters

  • Hwang, Wonjeong;Jang, Jun Ha;Huh, Minjin;Kim, Yeon Ju;Kim, Sang Won;Hong, In Ui;Lee, Mi Young
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.1
    • /
    • pp.34-39
    • /
    • 2016
  • Objective: Hip abductors play a role in providing stability and movement to the lower limbs. The purpose of this study was to examine the effects of hip abductor fatigue on static balance and gait in the general population. Design: One group pre-test post-test design. Methods: Thirteen university students in their twenties volunteered for the study and had underwent a functional assessment. To induce fatigue, the subjects were instructed to raise their dominant lower extremity up against a load of 50% of 1 repetition maximum while producing hip abduction in a side-lying position. Subjects were instructed to maintain an abduction speed of 30 repetitions per minute to induce fatigue. Muscle fatigue was considered to be established when subjects were unable to perform hip abduction three consecutive times along with the metronome. A post-test of balance and gait was performed immediately in order to prevent fatigue recovery. The center of pressure (COP) distance area was measured using the Zebris FDM-S Multifunction Force measuring plate. Gait performance was analyzed using the GAITRite. Results: The COP distance was increased after fatigue was induced. There was a significant increase in the standard deviation of the medio-lateral and antero-posteror distance (p<0.05). Although there was no significant difference in gait parameters, there was a significant decrease in single support time after fatigue was induced (p<0.05). Conclusions: There was an increase in static balance instability and a significant decrease in single support time during gait due to hip abductor muscle fatigue.

Selection and Design of Functional Area of Compression Garment for Improvement in Knee Protection (무릎 안전성 향상을 위한 컴프레션 의복의 기능적 디자인 영역 선정과 설계법)

  • Lee, Hyo Jeong;Kim, Nam Yim;Hong, Kyung Hi;Lee, Ye Jin
    • Korean Journal of Human Ecology
    • /
    • v.24 no.1
    • /
    • pp.97-109
    • /
    • 2015
  • Recently, because the market for compression wear now includes all consumers, not just professionals, various items for recovery after exercising or for enhanced effects from exercise have been introduced. In this research, a systematic and stepwise design process was proposed to develop compression garment that has both functional area and appropriate pressure to protect the knee when exercising. The U-V format functional area that wraps underneath the knee was selected by considering the shape and change in the skin length when bending the knee. After the selection of the functional area, a total of seven knee design areas, including the existing product, were designed to determine the appropriate pressure. After various movements, the compression garment was ranked in terms of support of the knee, level of pressure, discomfort of seam line, and comfort of popliteal; the preferred design was selected using the quad method. Four compression wear garments were produced using two selected preferred designs; the wear evaluation was performed using a seven-point Likert scale. As a result, the optimal reduction rate of the pattern was calculated based on Ziegert and Keil's method. The applied percentage of the fabric stretch at the upper part of the crotch was 66% for the width and 50% for the length; for the lower part of the crotch, only 66% for the width was applied. Moreover, it was determined that the design of the U-V knee protection part was preferred when a 7 mm square was placed at a 1 mm distance because this not only supports the knee but also allows the fabric to accommodate various skin deformations.

Measurement of Adiabatic Wall Temperature on an Impinging Surface by Under-expanded Jet (과소팽창된 충돌제트에 의한 단열벽면 온도 측정)

  • Yu, Man-Sun;Lee, Jang-Woo;Kim, Byung-Gi;Cho, Hyung-Hee;Hwang, Ki-Young;Bae, Ju-Chan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.79-84
    • /
    • 2005
  • An experimental investigation for impingement of under-expanded, axisymmetric jets on a flat plate has been conducted, and the surface pressure, the adiabatic wall temperature distributions on the plate have been measured in detail. For the explanation on the wall temperature distributions, the total temperature distributions along a free jet have also been measured with total temperature probes. In this study, the under-expansion ratio and the nozzle-to-plate distance have been considered as experimental parameters. Depending on nozzle-to-plate distances, different distributions of adiabatic wall temperature are shown by the energy separation at a jet edge and a impinged surface. Also, the recovery factor on a stagnation point decreases significantly due to the isolation of fluid particles in a central region.