• 제목/요약/키워드: pressure pulse

검색결과 1,215건 처리시간 0.023초

고온 세라믹필터의 펄스젯 탈진 성능에 관한 연구 (A Study on the Performance of Pulse Jet Cleaning in High Temperature Filter)

  • 김병렬;박승철;박병철;조현준;오형모;황태원;신상운
    • 방사성폐기물학회지
    • /
    • 제3권1호
    • /
    • pp.9-16
    • /
    • 2005
  • To evaluate parameters influencing on the dust removal of the High Temperature Filter(HTF) system, a computer simulation of fluid dynamics inside the system had been performed. The results showed that the optimum pulse jet periods were 50ms and 90ms for the 1000mm and 1500mm long filter elements respectively. Dust removal effect was very excellent under the pulse jet pressure of 3 bar. But the distance between the pulse jet nozzle and the venturi of a filter element had no meaningful effect on the performance with the variation from 5mm to 10mm. Compared to the dispersion mode of pulse jet, the collective mode of pulse jet flow was preferable in maintaining the pressure inside the system stable.

  • PDF

Optimal Characteristics of a Long-pulse $CO_2$Laser by Controlling SCR Firing Angle in AC Power Line

  • Noh, Ki-Kyung;Kim, Geun-Yong;Chung, Hyun-Ju;Min, Byoung-Dae;Song, Keun-Ju;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제2C권6호
    • /
    • pp.304-308
    • /
    • 2002
  • We demonstrate a simple pulsed $CO_2$ laser with millisecond long pulse duration in a tube at a low pressure of less than 30 Torr. The novel power supply for our laser system switches the voltage of the AC power line (60Hz) directly. The power supply doesn't need elements such as a rectifier bridge, energy-storage capacitors, or a current-limiting resistor in the discharge circuit. To control the laser output power, the pulse repetition rate is adjusted up to 60Hz and the firing angle of SCR(Silicon Controlled Rectifier) gate is varied from 30。 to 150。. A ZCS (Zero Crossing Switch) circuit and a PIC one-chip microprocessor are used to control precisely the gate signal of the SCR. The maximum laser output of 35 W is obtained at a total pressure of 18 Torr, a pulse repetition rate of 60 Hz, and a SCR gate firing angle of 90。 . In addition, the resulting laser pulse width is approximately 3㎳(FWHM). This is a relatively long pulse width, compared with other repetitively pulsed $CO_2$ lasers.

F형 다중펄스 로켓모타 적용 펄스분리장치 특성 분석 (Performance Analysis of a Pulse Separation Device for a F-type Multi-Pulse Rocket Motor)

  • 이동원;이원복;김인식;이방업
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.24-27
    • /
    • 2012
  • 본 연구에서는 격벽형 펄스분리장치의 성능을 검증하기 위하여 실물형 Flight-type의 이중펄스 로켓모타 추진기관을 설계, 제작하여 지상연소시험을 수행하였다. 지상연소시험 시 계측한 추진기관의 압력, 추력, 진동 결과를 바탕으로 펄스분리장치의 파열특성인 파열시간과 파열압력 분석을 실시하였고 연소시험 후 3차원 측정기를 이용한 삭마량 측정을 실시하였다. 그 결과, 펄스분리장치가 파열조건 및 열적 안전성을 만족하는 것을 확인할 수 있었다.

  • PDF

맥동관 냉동기 열교환기에 관한 실험적 연구 (An Experimental Study on the Heat Exchangers in the Pulse Tube Refrigerator)

  • 남관우;정상권;정은수
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.284-291
    • /
    • 2000
  • A basic pulse tube refrigerator has been constructed with extensive instrumentation to study the characteristics of the heat exchanger experimentally under the oscillating pressure and the oscillating flow. This paper describes the sequential experiments with the basic pulse tube refrigerator. The experiments were performed for various cycle frequencies under the square pressure wave forms. First, the heat flux was measured through the cycle at the both cold and warm end heat exchangers without the regenerator. In order to enhance the thermal communication capability of the heat exchanger with the gas at low operating frequencies, a unique design of the triangular shape radial fin concept was applied to the heat exchangers. For the fin heat exchanger, the measured heat flux and the calculated heat flux from the two well-known oscillating heat transfer correlations were compared and discussed. Second, the regenerator was added to the pulse tube to make a basic pulse tube refrigerator configuration. The experiment showed the great impact of the regenerator on the temperature and the heat flux profiles. At the warm-end, the cyclic averaged heat flux had its maximum value at the specific operating frequency. The paper presents the explanation of the surface heat pumping effect as well as the experimental data.

  • PDF

펄스 UV 램프를 이용한 미생물 소독 및 2-MIB 제거 특성 (Characteristics of Disinfection and Removal of 2-MIB Using Pulse UV Lamp)

  • 안영석;양동진;채선하;임재림;이경혁
    • 상하수도학회지
    • /
    • 제23권1호
    • /
    • pp.69-75
    • /
    • 2009
  • The characteristics of disinfection and organic removal were investigated with pulse UV lamp in this study. The intensity and emission wavelength of pulse UV Lamp were compared with low pressure UV lamp. The emission spectrum range of pulse UV lamp was between 200 and 400 nm while the emission spectrum of low pressure UV lamp was only single wavelength of 254nm. 3 Log inactivation rate of B. subtilis spore by pulse UV and low pressure UV irradiation was determined as $44.71mJ/cm^2$ and $57.7mJ/cm^2$, respectively. This results implied that wide range of emission spectrum is more effective compared to single wavelength emission at 254nm. 500ng/L of initial 2-MIB concentration was investigated on the removal efficiency by UV only and $UV/H_2O_2$ process. The removal efficiency of UV only process achieved approximately 80% at $8,600mJ/cm^2$ dose. 2-MIB removal rate of $UV/H_2O_2$ (5 mg/L $H_2O_2$) process was 25 times increased compared to UV only process. DOC removal efficiency for the water treatment plant effluent was examined. The removal efficiency of DOC by UV and $UV/H_2O_2$ was no more than 20%. Removal efficiency of THMFP(Trihalomethane Formation Potential), one of the chlorination disinfection by-products, is determined on the UV irradiation and $UV/H_2O_2$ process. Maximum removal efficiency of THMFP was approximately 23%. This result indicates that more stable chemical structures of NOM(Natural Organic Matter) than low molecule compounds such as 2-MIB, hydrogen peroxide and other pollutants affect low removal efficiency for UV photolysis. Consequently, pulse UV lamp is more efficient compared to low pressure lamp in terms of disinfection due to it's broad wavelength emission of UV. Additional effect of pulse UV is to take place the reactions of both direct photolysis to remove micro organics and disinfection simultaneously. It is also expected that hydrogen peroxide enable to enhance the oxidation efficiency on the pulse UV irradiation due to formation of OH radical.

다정보(多情報) 획득(獲得)을 위한 맥진기 개발과 임상적 의의 (The Development of pulse Diagnostic Apparatus enable to gain multi-information and it's Clinical Significance)

  • 박영배;이호재;허웅
    • 대한한의학회지
    • /
    • 제16권1호통권29호
    • /
    • pp.499-504
    • /
    • 1995
  • Recently, there are deep and much concerns about the objective assessment of diagnosis in Oriental Medicine. Among them, pulse diagnostics is used for the quantitative device of diagnosis. The objective research of pulse diagnosis were mainly conducted by pulse wave. So it is important to gain multi-information for the quantification of pulse diagnosis. We report the development of pulse diagnostic apparatus enable to gain the multi-information, detect the pressure pulse wave in conku(寸口) area and obtain the gradient curve and original pulse wave simultaneously, and consider the pulse wave with the traditional pulse diagnosis at the same time.

  • PDF

Infrared Multiphoton Dissociation of $CHCl_2F$: Reaction Mechanisms and Product Ratio Dependence on Pressure and Laser Pulse Energy

  • Song, Nam-Woong;Lee, Won-Chul;Kim, Hyong-Ha
    • Journal of Photoscience
    • /
    • 제12권2호
    • /
    • pp.101-107
    • /
    • 2005
  • Infrared multiphoton dissociation of $CHCl_2F$ was studied using $CO_2$ laser excitation. Three products, $C_2Cl_2F_2$, $C_2ClF_3$, and $C_2HClF_2$, were identified by the analysis of the gas mixture from the photoreaction of $CHCl_2F$. The dependence of the reaction probability on added Ar gas pressure and excitation laser pulse energy was investigated. At low pressure (< 10 torr), the reaction probability increased as Ar pressure increased due to the rotational hole-filling effect, while it diminished with the increase of Ar pressure at high pressure (> > 20 torr) due to the collisional deactivation. The ratio of two products $(C_2ClF_3/C_2Cl_2F_2)$ decreased at low pressure (< 10 torr) and increased at high pressure (> 20 torr) with the increase of Ar pressure. The log-log plot of the reaction probability vs. laser pulse energy (${\\phi}$) was found to have a linear relationship, and its slope decreased as the added Ar pressure was increased. The reaction mechanisms for product formation have been suggested and validated by experimental evidences and considering the energetics. Fluorine-chlorine exchange reaction in the intermediate complex has been suggested to explain the formation of $C_2ClF_3$.

  • PDF

심장 치료 전후의 혈압 측정 인자의 변화에 관한 연구 (A Study on the Changes of Blood Pressure Measurement Factors Before and After Heart Treatment)

  • 최원석
    • 융합신호처리학회논문지
    • /
    • 제22권2호
    • /
    • pp.51-56
    • /
    • 2021
  • 상완 수축기 혈압과 맥압은 50세 이상의 개인에서 심혈관 질환의 예측 인자이다. 강성이 증가함에 따라 수축기 후기의 반사 진폭과 압력이 증가하여 좌심실 부하와 심근 산소 요구량이 증가한다. 따라서 강성이 혈압에 미치는 영향을 연구 할 필요가 있다. 본 연구에서는 약물 복용 전후에 혈압 맥파를 측정하고, 심부전 환자에서 심근 심장 이식 전후에 혈압 맥파를 측정하였다. Windkessel 모델의 R, L 및 C 구성 요소 간의 상관관계는 혈압을 높임으로써 추정되었다. 커브 피팅 방법을 사용하여 Windkessel 모델의 매개 변수를 모델링 한 결과 혈압의 증가와 수축기 상승 시간의 감소는 RLC Windkessel 모델의 L 성분이 증가했기 때문이다. 혈관의 다양한 기계적 특성 중에 높은 BP 파형에 영향을 미치는 가장 중요한 매개 변수는 실험결과로 이너턴스인 것을 증명하였다.

단일액체추진제 하이드라진 추력기의 펄스모드 추력 거동 연구 (A Study on the Pulse-mode Thrust Behavior of Liquid-monopropellant Hydrazine Thruster)

  • 김정수;박정;최종욱;김성초;장기원
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제24회 춘계학술대회논문집
    • /
    • pp.194-197
    • /
    • 2005
  • 추진제 주입압력 350 psia 에서 0.95 lbf 의 정상상태 공칭추력을 내는 단일액체추진제 하이드라진 추력기의 펄스모드 성능평가 결과를 제시한다. 연소시험 절차에 대한 간략한 기술과 함께 펄스모드 작동으로부터 얻어지는 추진제 공급압력, 추력기 작동환경 진공도, 그리고 추력 등의 변이거동에 대한 전형적인 결과를 추력기의 열적 반응과 더불어 검토한다. 제시된 성능은 1-lbf급 표준형 단일추진제 로켓엔진의 펄스모드 기준성능과 성공적으로 비교된다.

  • PDF

광센서와 압력센서를 이용한 맥박측정시스템 개발 (Development of Blood Pressure Measuring System using piezoelectric and photo sensor)

  • 최영숙;김경재;홍우헌;류정탁
    • 한국산업정보학회논문지
    • /
    • 제14권5호
    • /
    • pp.149-154
    • /
    • 2009
  • 사람들의 평균 수명이 늘어남으로써 건강에 대한 관심도가 매우 높아지고 있다. 그에 따라 사람들은 자신의 몸 상태를 체크하며 주기적으로 자신의 건강상태를 확인하기 위해 정기검진을 받는다. 그러나 평소 자신의 맥박이나 혈압의 체크를 통하여 건강관리 및 질병예방이 가능하다. 따라서 본 논문에서는 간편하게 얻을 수 있으면서도 기본적이고 유용한 정보를 많이 가지고 있는 맥박신호를 혈액량에 따라 투과율의 변화를 측정할 수 있는 광센서를 이용한 방법과 압전 센서를 사용하여 손목의 요골동맥의 압력을 측정하여 맥박을 측정할 수 있는 휴대용 맥박측정 시스템을 구현하였으며 두 방법으로 제작된 시스템을 비교연구 하였다.