• Title/Summary/Keyword: pressure pulse

Search Result 1,215, Processing Time 0.031 seconds

Numerical and Experimental Verification of Stress Wave Control Effect in SHPB Experiment using Pulse Shaper (Pulse Shaper를 이용한 SHPB 실험 응력파 제어 효과의 해석 및 실험적 검증)

  • Kim, Y.H.;Woo, M.A.;Kang, B.S.;Kim, J.
    • Transactions of Materials Processing
    • /
    • v.26 no.5
    • /
    • pp.314-322
    • /
    • 2017
  • In the high-speed forming analysis, dynamic material properties considering a high strain rate are required. The split Hopkinson pressure bar (SHPB) experiment was performed for measuring dynamic material properties under high strain rate. The pulse shaping method was used to improve the accuracy of the SHPB experiment. A pulse shaper attached to the front of the incident bar was used for specimen dynamic stress equilibrium through stress wave control. Numerical analysis and SHPB test were performed to verify whether the pulse shaper affects the dynamic stress equilibrium in copper and Al6061 specimens. The results of SHPB test and numerical analysis show that the pulse shaper contributes to the dynamic stress equilibrium. Based on the improved stress equilibrium using a pulse shaper, the flow stress curves for copper and Al6061 materials were obtained at strain rates of 1344.4/sec and 1291.6/sec, respectively.

The Relationship between the Serum Aspartate Aminotransferase/Alanine Aminotransferase Ratio and Pulse Pressure in Korean Adults with Hypertension (대한민국 고혈압 성인에서 아스파르트산 아미노전이효소/알라닌 아미노전이효소 비율과 맥압의 관련성)

  • Yoon, Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.3
    • /
    • pp.241-248
    • /
    • 2021
  • The present study was conducted to assess the relationship between aspartate aminotransferase/alanine aminotransferase (AST/ALT) ratio and pulse pressure in Korean adults with hypertension. Data from 1,515 adults from the sixth Korean National Health and Nutrition Examination Survey (KNHANES VI-3, 2015) were analyzed. There were several key findings in the present study. First, aspartate aminotransferase (odds ratio [OR], 1.018; 95% confidence interval [CI], 1.002 to 1.033), alanine aminotransferase (OR, 0.982; 95% CI, 0.969 to 0.996), and aspartate aminotransferase/alanine aminotransferase ratio (OR, 1.367; 95% CI, 1.027 to 1.819) were the independent factors determining high pulse pressure. Second, after adjusting for related variables [age, gender, smoking, alcohol consumption, regular exercise, total cholesterol (TC), triglycerides (TGs), high-density lipoprotein-cholesterol (HDL-C), fasting plasma glucose (FPG), body mass index (BMI), and waist circumference (WC)], the ORs of high pulse pressure with the 1st quartile as a reference were significantly higher in the 4th quartile of aspartate aminotransferase/alanine aminotransferase ratio [1.632 (95% CI, 1.113~2.393)]. The high pulse pressure was positively associated with aspartate aminotransferase and alanine aminotransferase/alanine aminotransferase ratio in Korean adults with hypertension, but was inversely associated with alanine aminotransferase.

Analysis of Fourier Amplitude of Pulse Wave with Varying Contact Pressure (압력에 따른 맥파의 푸리에 분석)

  • Yoon Young-Jun;Lee Myeong-Hwa;Shin Hak-Soo;Johng Hyun-Min;Cho Johng-Hyun;Soh Kwang-Sup
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.3 no.1
    • /
    • pp.173-179
    • /
    • 1999
  • We investigate how the frequency and the Fourier amplitude of the pulse wave behave as the contact pressure of the sensor on the skin increases. The results are that the fundamental frequency of the pulse wave hardly changes and the Fourier amplitude has several different patterns depending on the personal constitution, and its patterns are classified. We also show that the classified patterns can be related to the different pulse types by the magnitude of the pressure required to reach the maximum Fourier amplitude and the range of the pressure at which the maximum Fourier amplitude is maintained.

  • PDF

The Correlation of Pulse Wave Velocity and Atherosclerotic Risk Factor in Stroke Patients

  • Jin, Bok Hee;Han, Min Ho
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.1
    • /
    • pp.28-34
    • /
    • 2015
  • Pulse wave velocity (PWV) is used to non-invasively estimate the severity of arteriosclerosis by measuring arterial stiffness. Increased arterial stiffness measured by PWV stands for progressive arteriosclerosis and is caused by atherosclerotic risk factors. This study is focused on how brachial-ankle pulse wave velocity (baPWV) is related to the leading risk factors for arteriosclerosis or atherosclerosis. Subjects were 114, 69 males and 45 females who are in 60's and had baPWV test for acute stroke. The results are as follows: the group with increased arterial stiffness showed significant increase in HbA1c, total cholesterol, BSBP (brachial artery systolic blood pressure), BDBP (brachial artery diastolic blood pressure), CSBP (central artery systolic blood pressure), CDBP (central artery diastolic blood pressure), augmentation index (AIx) and diabetes mellitus. Correlation analysis between baPWV and atherosclerotic risk factor showed significant relationship in age, HbA1c, LDL cholesterol, BSBP, BDBP, CSBP, CDBP and augmentation index. baPWV was independently related to age and BSBP in multiple linear regression analysis. The group with increased arterial stiffness was independently related to BDBP in multiple logistic regression analysis. This study might be meaningful in evaluating the relationship between arterial stiffness and atherosclerotic risk factor in a new way, and be helped to make various studies for cardiovascular disease.

The Effects of Heat Therapy on Low Back Pain, Blood Pressure and Pulse Rate after Percutaneous Coronary Intervention (경피적 관상동맥 중재술 후 온요법이 요통, 혈압 및 맥박에 미치는 효과)

  • Yun, So-Young;Cho, Bok-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.18 no.3
    • /
    • pp.348-355
    • /
    • 2011
  • Purpose: This study was done to examine the effects of heat therapy on low back pain, blood pressure and pulse rate after percutaneous coronary intervention. Method: The participants in this study were 40 patients who were admitted after having percutaneous coronary intervention. The experimental group, 20 patients, had heat therapy and the control group, 20 patients, maintained a supine position for 12 hours after the intervention. Back pain (VAS), blood pressure and pulse rate were measured just after removal of the sheath, and at 2-hour intervals up to 6 hours. Data were analyzed using SPSS 15.0. Results: The experimental group had significantly lower VAS for low back pain (F=23.44, p=.001). However no significant differences were found between two groups for blood pressure and pulse rate. Conclusion: The findings indicate that heat therapy is effective in reducing low back pain in patients who have had percutaneous coronary intervention. Therefore, heat therapy could be used as nursing intervention percutaneous coronary intervention.

A Study on the Radial Pulse Detection System for the Total Macjin( I ) (총안 맥진을 위한 맥동검출기 개발에 관한 연구( I ))

  • Kim, K.S.;Yang, S.Y.;Han, S.C.;Park, Y.B.;Kim, J.K.;Huh, W.
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.551-554
    • /
    • 1999
  • In this paper, we developed a radial pulse transducer that has strain-gauge cantilever type load cell for total pulse detection on chongu arterial. The transducer consist of load cell and driving electronic circuits. Load cell consist of cantilever and two metal film strain gauge. The Pressure signal from chongu artery is delivered to load cell using artery rider that attached to cantilever Therefore the pressure signal convert to voltage signals by the developed transducer As the results of experiment, the developed transducer has very good linearity at pressure to voltage conversion. The total pulse detection transducer can detected three kinds of chongu artery pulse with conveniently.

  • PDF

A study on the in-line type inertance tube pulse tube cryocooler for cooling Superconductor filter

  • Park, Seong-Je;Hong, Yong-Ju;Kim, Hyo-Bong;Kim, Seon-Young;Jung, Woo-Seok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.46-50
    • /
    • 2004
  • The Experimental results of the in-line type inertance tube pulse tube cryocooler for cooling superconductor RF filter are presented in this paper. The pulse tube refrigerator, which has no moving parts at its cold section, is attractive in obtaining higher reliability, simpler construction, and lower vibration than any other small refrigerators. The purpose of this study is to analyze the characteristics of in-line type inertance tube pulse tube refrigerator (IPTR), and to get main factor to improve the performance of the in-line type IPTR. Firstly, design parameters of the in-line IPTR are discussed by ARCOPTR program, and then to find optimal conditions of in-line type IPTR, cool down characteristics according to the variations of the charging pressure, inertance tube volume, regenerator volume and pulse tube volume are measured by the experiment. The lowest temperature of the cold end was about 50 K. Cooling capacity was the highest in the charging pressure of 32 atm. and 5W at 72K. On the other hand, COP of the in-line type IPTR was the highest in the charging pressure of 21 atm. and 0.018 at 77K.

Development of a Cardiovascular Simulator with Cardiovascular Characteristics (혈관계의 특성이 반영된 심혈관계 시뮬레이터의 개발)

  • Lee, Ju-Yeon;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.16 no.3
    • /
    • pp.33-40
    • /
    • 2012
  • Objectives: Existing cardiovascular simulators are used to evaluate artificial organs such as artificial hearts, prosthetic valves, and artificial blood vessels, and pulses are typically triggered using artificial hearts. However, the forms of pulse waves vary according to the location of arteries, and for precise assessment of artificial blood vessels, the development of simulators that generate diverse pressure pulse waves is necessary. This study developed a novel cardiovascular simulator that generates different forms of pulse waves. Methods: This simulator consists of a stepping motor, a slider-crank mechanism that transforms the rotation movement of a motor into the straight-line motion of a piston, a piston that generates pulsatile flows, a water tank that supplies fluids, an elastic tube made of silicon, and a device that adjusts the terminal resistance of fluids. Results & Conclusion: This study examined motor rotation and its operation under conditions similar to the physiological conditions of the heart. The simulator developed in this study produced diverse forms of waves, and the generated pressure waves well satisfied physiological conditions.

Comparative Study on the Pulse Wave Variables and Sasang Constitution in Diabetes Mellitus Patients and Healthy Subjects (당뇨병 환자와 건강인의 맥상과 사상체질에 관한 연구)

  • Park, Su-Jeong;Kim, Kyung-Yo;Lee, Si-Woo;Kwon, Young-Mi;Kil, Eun-Young;Joo, Jong-Cheon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.6
    • /
    • pp.1601-1610
    • /
    • 2007
  • The purpose of this study was to determine whether a pulse analyzer was useful 1) to characterize the variables of pulse wave of diabetes mellitus group, compared with those of healthy subjects, and 2) to determine Sasang Constitution in diabetes mellitus group and healthy subjects. 1. The sum of pulse pressure (energy) and the ratio of systolic period area (As%), called pulse pressure-related variables, were higher in diabetes mellitus group than healthy group, while the height of dicrotic wave (h5) and the ratio of height of dicrotic wave to height of percussion wave (h5/h1), correlated with arterial compliance, were lower in diabetes mellitus group than healthy group. 2. Taeumin of diabetes mellitus group showed higher pressure-related variables than that of healthy group. 3. Soumin of diabetes mellitus group had shorter the time to dicrotic wave (t5) than that of healthy group. 4. Soyangin of diabetes mellitus group showed higher heart rates and lower values in pulse wave time-related variables, including time to dicrotic wave(t5), time to incisura (t4), total time minus time to incisura (t-t4), total time (t), width of percussion wave (w), and the ratio of width of percussion wave to total time (w/t), than that of healthy group. 5. Contact pressure (CP), sum of pulse pressure (energy), height of pre-incisura (h2), height of incisura (h4), width of percussion wave (w), time to incisura (t4), time to percussion wave (t1), variance of total time (Vt), variance of height of percussion wave(Vp) and the ratio of height of incisura to height of percussion wave (h4/h1) were used to develop the rules of Sasang Constitution Classification with about seventy five percents accuracy. These suggested that the pulse analyzer was useful to evaluate the risk degree of diabetes mellitus and to determine Sasang Constitution among either diabetes mellitus group or healthy group.

The Change of Children's Blood Pressure and Factors Affecting the Level of Blood Pressure In Children (아동혈압의 시계열 변화 양상 및 평균혈압에 관련된 요인 분석)

  • Suh, Il;Kim, Il-Soon;Nam, Chung-Mo;Lee, Soon-Young;Oh, Hee-Chul;Kim, Chun-Bae;Park, Eun-Cheol
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.3 s.27
    • /
    • pp.303-312
    • /
    • 1989
  • To show the distribution and change of blood pressure according to age and to find factors affecting the level of blood pressure in primary school children, a follow-up study was conducted from 1986 to 1989 on 401 first grade children attending primary school in Kangwha County in 1986 and their parents. The blood pressure of the children was significantly increased according to age. The average annual increase was 1.8mmHg in systolic blood pressure and 2.5mmHg in diastolic blood pressure. The level of blood pressure did not show any significant difference in both sexes. Among children who were at or above the 80th percentile of blood pressure in the first grade, 35 and 30% of them have remained at the same level of systolic and diastolic blood pressure respectively in the fourth grade. But we could not find any significance in the tracking of blood pressure of children who were at or above the 90th percentile of blood pressure in the first grade. Weight and pulse rate were shown to be significant factors affecting systolic blood pressure in children of both sexes and mother's blood pressure and skinfold thickness were also affected systolic blood pressure in girls. The variables significantly affecting diastolic blood pressure were arm circumference and pulse rate for boys and height and pulse rate for girls.

  • PDF