• Title/Summary/Keyword: pressure piping

Search Result 668, Processing Time 0.029 seconds

Evaluation of Crack Growth Estimation Parameters of Thick-Walled Cylinder with Non-Idealized Circumferential Through-Wall Cracks (비 이상화된 원주방향 관통균열이 존재하는 두꺼운 배관의 균열 성장 매개변수 계산)

  • Han, Tae-Song;Huh, Nam-Su;Park, Chi-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.138-146
    • /
    • 2013
  • The present paper provides the elastic stress intensity factors(SIFs) of thick-walled cylinder with non-idealized circumferential through-wall cracks. For estimating these elastic SIFs, the systematic three-dimensional(3D) elastic finite element(FE) analyses were performed. In order to consider practical shape of thick-walled cylinder and non-idealized circumferential through-wall crack, the values of thickness of cylinder, reference crack length and crack length ratio were systematically varied. As for loading conditions, axial tension, global bending and internal pressure were considered. In particular, in order to calculate the SIFs of thick-walled cylinder with non-idealized circumferential through-wall crack from those of thick-walled cylinder with idealized circumferential through-wall crack, the correction factor representing the effect of non-idealized crack on the SIFs were proposed in this paper. The present results can be applied to accurately evaluate the rupture probabilities of nuclear piping considering actual crack growth behaviors.

[ $C^{\ast}$ ]-integral Based Life Assessment of High Temperature Pipes ($C^{\ast}$-적분에 기초한 고온배관 수명평가)

  • Lee Hyungyil
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.4 s.12
    • /
    • pp.25-33
    • /
    • 2000
  • In recent years, the subject of remaining life assessment has drawn considerable attention in power plants, where various structural components typically operate at high temperature and pressure. Thus a life prediction methodology accounting for high temperature creep fracture is increasingly needed for the components. Critical defects in such structures are generally found in the form of semi-elliptical surface crack, and the analysis of which is consequently an important problem in engineering fracture mechanics. On this background, we first develop an auto mesh generation program for detailed 3-D finite element analyses of axial and circumferential semi-elliptical surface cracks in a piping system. A high temperature creep fracture parameter $C^{\ast}$-integral is obtained from the finite element analyses of generated 3-D models. Post crack growth module is further appended here to calculate the amount of crack growth. Finally the remaining lives of surface cracked pipes for various analytical parameters are assessed using the developed life assessment program.

  • PDF

Behavior of Elastic and Plastic Limit Loads of Thinned Elbows Observed During Real-Scale Failure Test Under Combined Load (감육엘보 실증실험에서의 탄성 및 소성 한계하중 거동 고찰)

  • Lee, Sung-Ho;Lee, Jeong-Keun;Park, Chi-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1293-1298
    • /
    • 2010
  • In most power plants, wall thinning in carbon-steel pipes due to flow-accelerated corrosion is one of the major aging phenomena, and it reduces the load-carrying capacity of the piping system. Various types of wall-thinning defects were manufactured in real-scale elbows, and monotonic in-plane bending tests were performed under internal pressure to evaluate the failure behavior of the elbows. In this paper, the behavior of elastic and plastic limit leads of locally thinned elbows in a real-scale failure test is presented. The loads determined on the basis of TES (twice elastic slope) were considered to be the limit loads of locally thinned elbows so that the integrity of the thinned elbows could be maintained, even when a small amount of plastic deformation might have occurred.

One Dimensional Analysis on Alcohol Burner Flow for Turbopump Operation (터보펌프 구동용 알코올버너 유동 일차원 해석)

  • Kim, Seong-Lyong;Wang, Seung-Won;Han, Young-Min
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.4
    • /
    • pp.1-11
    • /
    • 2017
  • TPTF (Turbopump Real Propellant Test Facility) at Naro Space Center has used alcohol burner system to simulate the gas flow of gas generator of liquid rocket engine. During the test at TPTF, the temperature and pressure at turbine inlet were smoothly increased while those of the gas generator of engine were constant. Present research developed a simulation code for the burner and the piping system and applied to the system. The calculation results were in good agreement with the test, and confirmed quantitatively that the non-steadiness is due to the heat transfer of the pipe. While the insulation of the pipe is ineffective, the length has a large impact on the turbine inlet condition. The present research clarified the empirically estimation of test condition, and can be applied to determination of the following test conditions.

An experimental study on the operating performance of facade installed natural circulation type solar thermal system (수직벽면형 무동력 태양열 시스템 작동성능에 관한 실험적 연구)

  • Baek, Nam-Choon;Lee, Wang-Je;Lee, Jin-Kook;Lee, Soon-Myung
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.4
    • /
    • pp.1-7
    • /
    • 2015
  • The operation of the natural circulation type solar heating systems with facade integrated collector was analyzed by experiment. Two different types of flat plate solar collectors were used for these experiments. One was for the normal flat plate solar collector with the size of 1m*2m and the other was for the large size solar collector with $4m^2$(1m*4m). The experiments were carried out to investigate the effect of the series or parallel connection method on the performance of the collectors. As a result, the solar thermal system which is installed on the wall or facade would be applicable for the natural circulation type if the system design reflects various parameters, including collector connecting method(series or parallel), to provide enough vertical height between collector and storage tank, and to reduce pressure loss due to collector and piping network, etc. The natural circulation type of solar thermal system as proposed in this study can increase the system reliability by removing or minimizing the use of the components such as pump, controller, sensors which may cause serious troubles of the system for a long-time operation

Tensile and impact toughness properties of various regions of dissimilar joints of nuclear grade steels

  • Karthick, K.;Malarvizhi, S.;Balasubramanian, V.;Krishnan, S.A.;Sasikala, G.;Albert, Shaju K.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.1
    • /
    • pp.116-125
    • /
    • 2018
  • Modified 9Cr-1Mo ferritic steel is a preferred material for steam generators in nuclear power plants for their creep strength and good corrosion resistance. Austenitic stainless steels, such as type 316LN, are used in the high temperature segments such as reactor pressure vessels and primary piping systems. So, the dissimilar joints between these materials are inevitable. In this investigation, dissimilar joints were fabricated by the Shielded Metal Arc Welding (SMAW) process with Inconel 82/182 filler metals. The notch tensile properties and Charpy V-notch impact toughness properties of various regions of dissimilar metal weld joints (DMWJs) were evaluated as per the standards. The microhardness distribution across the DMWJs was recorded. Microstructural features of different regions were characterized by optical and scanning electron microscopy. Inhomogeneous notch tensile properties were observed across the DMWJs. Impact toughness values of various regions of the DMWJs were slightly higher than the prescribed value. Formation of a carbon-enriched hard zone at the interface between the ferritic steel and the buttering material enhanced the notch tensile properties of the heat-affected-zone (HAZ) of P91. The complex microstructure developed at the interfaces of the DMWJs was the reason for inhomogeneous mechanical properties.

Identification between Local Wall Thinning and Turbulent Velocity Components by Flow Acceleration Corrosion inside Tee of Pipe System (배관계 티에서 유동가속부식으로 인한 난류속도성분과 국부감육의 관계 규명)

  • Kim, Kyung-Hoon;Lee, Sang-Kyu;Cho, Yun-Su;Hwang, Kyung-Mo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.7
    • /
    • pp.483-491
    • /
    • 2011
  • When pipe components made of carbon steel in nuclear, fossil, and industry are exposed to flowing fluid, wall thinning caused by FAC(flow accelerated corrosion) can be generated and eventually ruptured at the portion of pressure boundary. A study to identify the locations generating local wall thinning and to disclose turbulence coefficient related to the local wall thinning was performed. Experiment and numerical analyses for tee of down scaled piping components were performed and the results were compared. In particular, flow visualization experiment which was used alkali metallic salt was performed to find actual location of local wall thinning inside tee components. To disclose the relationship between turbulence coefficients and local wall thinning, numerical analyses were performed for tee components. The turbulence coefficients based on the numerical analyses were compared with the local wall thinning based on the measured data. From the comparison of the results, the vertical flow velocity component(Vr) flowing to the wall after separating in the wall due to the geometrical configuration and colliding with the wall directly at an angle of some degree was analogous to the configuration of local wall thinning.

Experimental Research on Effects of Water Sprayed Curtain On Anti-diffusion of Fire Gases in Case of Tunnel Fire (터널 화재시 물분무노즐에 의해 형성되는 제연수막의 연기층 확산방지성능에 관한 실험적 연구)

  • Park, Hyung-Joo;Choi, Young-Sang;Jee, Nam-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.97-103
    • /
    • 2004
  • In case of a fire in road or railway tunnel it is always necessary to keep the escape condition as good as possible. Most of the victims of major fires in tunnels are because they couldn't leave the tunnel in time and were trapped by smoke, or rescue teams couldn't reach the place of the accident due to low visibility and high temperature. In spring 2003 a comprehensive field experiment was undertaken in a large scaled tunnel in Youngin City to test the effectiveness of a new water spray curtain system, designed to the air qualify inside of a tunnel in case of fire during passenger's escape to safe routes, In order to control the smoke propagation, fixed water sprayed nozzles were used to make water curtain system, which can be installed or hanging water piping line below ceiling. The experiment was accompanied by an extensive measurement campaign in order to measure temperature dropping effect and flow conditions as well as CO concentration for various water sprayed curtains produced by sprinkler heads or water spray nozzle. Eventually comparison analysis were undertaken to investigate the performance of water curtains under fixed water pressure. Therefore most effective water curtain system was presented on the basis of water droplet size in long tunnel.

A Study on the cleansing of water data using LSTM algorithm (LSTM 알고리즘을 이용한 수도데이터 정제기법)

  • Yoo, Gi Hyun;Kim, Jong Rib;Shin, Gang Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.501-503
    • /
    • 2017
  • In the water sector, various data such as flow rate, pressure, water quality and water level are collected during the whole process of water purification plant and piping system. The collected data is stored in each water treatment plant's DB, and the collected data are combined in the regional DB and finally stored in the database server of the head office of the Korea Water Resources Corporation. Various abnormal data can be generated when a measuring instrument measures data or data is communicated over various processes, and it can be classified into missing data and wrong data. The cause of each abnormal data is different. Therefore, there is a difference in the method of detecting the wrong side and the missing side data, but the method of cleansing the data is the same. In this study, a program that can automatically refine missing or wrong data by applying deep learning LSTM (Long Short Term Memory) algorithm will be studied.

  • PDF

Pressure fluctuation and characteristics of hydraulic jump downstream of a transversal structure for various Froude numbers (다양한 흐름조건에 따른 하천횡단구조물 하부의 도수특성 및 압력변동성 검토)

  • Yoo, Hyung Ju;Jeong, Seok il;Lee, Seung Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.63-63
    • /
    • 2018
  • 최근 이상기후로 인한 국지성 호우의 발생빈도 및 강우강도의 증가는 하천횡단구조물의 안정성에 문제가 되고 있다. 하천 횡단구조물(보, 물받이공 등)의 파괴는 국부 세굴(bed scour), 파이핑(piping), 구조물 본체의 불안정성 등의 원인으로 발생되고 있으며, 이 중에서 구조물 본체의 불안정성은 도수(hydraulic jump)로 인한 압력변이도 주요 원인이 될 수 있다 (Bower and Toso, 1988; Kazemi, F. et al., 2016). 그러나, 현재 직접적인 파괴 원인인 세굴 등에 대한 연구에 비해 압력변이로 인한 구조물의 파괴원인을 분석하는 연구는 미비한 실정이다. 본 연구에서는 다양한 흐름조건을 발생시켜, 하천횡단구조물 주변의 도수특성 및 도수로 인한 압력변이에 대하여 수리실험 및 수치모의를 통하여 검토하고자 한다. 수리실험에 사용하는 수로는 길이 10 m, 폭 0.3 m, 높이 0.4 m이며 상류로부터 2.5 m 떨어진 곳에 보(weir)를 설치하였다. 실험조건은 다양한 흐름조건에 따른 도수 발생을 검토하고자 상하류 수위를 조절을 통해 Froude 수의 범위를 1 < Fr < 10로 설정하였다. 압력변이는 전압형 압력계(Model : UNIK 5000, 압력 측정 변위 : -2 ~ 5 kPa)를 사용하였으며, 보(weir) 하류단에서 2.5 cm 간격으로 천공하여 측정하였다. 또한 3차원 모형인 FLOW-3D 모형을 이용하여 실험수로를 재현하였으며, 도수 발생 위치, 도수 길이, 도수 발생 시 압력변이에 대하여 실험결과와 수치모의 결과를 비교하여 수치모형을 검증하였다. 최종적으로 Froude 수에 따른 도수특성(도수 발생위치, 도수 길이 등) 및 최대 압력변이를 무차원화 하여 나타내었다. 본 연구는 도수 발생 시 압력변이로 인한 구조물 파괴분석에 대한 기초가 되는 기본적인 연구이나, 향후에는 물받이공 길이, 두께 등 하천횡단 구조물 설계인자 도출에 선행연구로 발전할 수 있다고 판단된다.

  • PDF