• 제목/요약/키워드: pressure piping

검색결과 668건 처리시간 0.034초

급수배관시스템의 수충격 진동제어를 위한 실험적 연구 (An Experimental Study on Vibration Control of Water Hammering in Water Pipe System)

  • 이장현;이효행;권병하;오진우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.453-458
    • /
    • 2008
  • Pump of high lift use to development of a technological level according as a building grow big. Water-Hammer to increase by valve of fast to closing agreeably to pipe laying to accept electronic valve, because by a damage of piping-system and the devil knows injury of vibration. Water-Hammer take a low effect to various method for solve. A New type manufacture develop and testing of pipe line to same to axis use to accumulator for water-Hammer to low effect and liner control of pressure. Impact-pressure of absorption ability and confirmation to decrease of vibration level through to preexistence manufactures and comparative test. Water-hammer and pipe vibration make low of piping system.

  • PDF

원전 증기발생기 감육 급수링 응력해석 (A Stress Analysis of Wall-Thinned Feedwater Ring in Nuclear Power Plant)

  • 조민기;조기현
    • 한국압력기기공학회 논문집
    • /
    • 제17권1호
    • /
    • pp.56-63
    • /
    • 2021
  • The feedwater ring is an assembly in steam generator internal piping, which distributes feedwater into the secondary side of the steam generator. It consists of an assembly of carbon steel piping, pipe fittings and J-nozzles which are inserted into the top of the feedwater ring and welded to the diameter of the ring. The feedwater ring at the attachment region of the J-nozzle may be susceptible to flow accelerated corrosion (FAC) due to flow turbulence which increases local fluid velocities. If a J-nozzle becomes a loose part, it can cause damage to tubing near the tube sheet. In this paper, the structural stress analysis for a wall thinned feedwater ring and integrity evaluations under assumed loading conditions are carried out in compliance with ASME B&PV SecIII, NB-3200.

감육 배관의 다양한 보강 형태에 따른 이론적 등가 강성 검증 (Analytical Equivalent Stiffness Analysis for Various Reinforcements of Wall-thinned Pipe)

  • 장제훈;김지수;김윤재
    • 한국압력기기공학회 논문집
    • /
    • 제18권1호
    • /
    • pp.11-18
    • /
    • 2022
  • When wall-thinning in a pipe occurs during operation of nuclear power plant, reinforcement of the pipe needs to be performed. Accordingly, the structural response of the piping system due to introduction of the reinforcement may be re-evaluated. For elastic structural analysis of the piping system with the reinforced pipe using finite element (FE) analysis, the stiffness of the reinforced pipe is needed. In this study, the stiffness matrix of wall-thinned pipe with pad reinforcement or composite reinforcement is analytically derived. The validity of the proposed equations is checked by comparing with systematic finite element (FE) analysis results.

전달행렬법을 이용한 3차원 파이프 계의 진동해석 (Vibration Analysis of Three-Dimensional Piping System by Transfer Matrix Method)

  • 이동명
    • 한국생산제조학회지
    • /
    • 제7권6호
    • /
    • pp.110-116
    • /
    • 1998
  • For the vibration analysis of 3-dimensional piping system containing fluid flow, a transfer matrix method is presented. The fluid velocity and pressure were considered, that coupled to longitudinal and flexural vibrations. Transfer matrices and point matrices were derived from direct solutions of the differential equations of motion of pipe conveying fluids, and the variations of natural frequency with flow velocity for 3-dimensional piping system were investigated.

  • PDF

전산유체해석(CFD)을 이용한 밸브의 급폐쇄에 따른 다중 배관 수격 현상에 관한 연구 (Study on a Multi-pipe Water Hammer Phenomenon by using CFD of Rapid Valve Closing)

  • 박노석;김성수;강문선;최종웅
    • 상하수도학회지
    • /
    • 제27권4호
    • /
    • pp.479-487
    • /
    • 2013
  • This study was to investigate characteristics for the pressure wave propagation and the maximum pressure near a rapid closure valve which was installed the end of multi piping network. The multi piping network consists of one inlet and three outlet with straight pipes. The diameter of the pipes including the valve was 100 mm, 80 mm, 80 mm respectively. The valve was rapidly closed with the instantaneous time which was 0.023s in the level for the water hammer. For the simulation, the influence of the pipe thickness and deformation due to pressure-wave-propagation was not considered. CFD was conducted under the following condition : the initial pressure was 1bar in the inlet and the mass flow rate was 7.83 kg/s in the outlet(the velocity in the pipe with 100 mm diameter was 1 m/s). As the valve have conditions that were status with and without fluid flow in the pipe after valve closing, the maximum pressure change and the frequency analysis were examined. As the results, the case that was status with fluid flow appeared the higher maximum pressure than another's, the maximum frequency band was about 10 ~ 11 Hz.

PB 배관에서의 유체압력에 관한 연구 (The Analysis of Fluid Pressure in Polybutylene Piping System)

  • 이용화
    • 설비공학논문집
    • /
    • 제18권1호
    • /
    • pp.17-23
    • /
    • 2006
  • This study is to investigate the pressure wave characteristics and the maximum pressure rise generated by instantaneous valve closure at the end of the straightening polybutylene piping system. Experiments were conducted under the following conditions: initial pressure $1\~5$ bar, flow velocity $\~0.5-3.0m/s$ and water temperature $25^{\circ}C$. Results indicated that the peak pressure generated by quick valve closure reached Joukowsky's value. We also found that the maximum pressure rise and the pressure history depended on not only initial steady pressure but also flow velocity.

감육이 존재하고 내압과 굽힘하중의 복합하중을 받는 T 분기관의 한계하중 (Limit Loads for Piping Branch Junctions with Local Wall-thinning under Internal Pressure and In-plane Bending)

  • 한재준;이국희;김윤재;이성호;박치용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.299-304
    • /
    • 2008
  • This paper presents plastic limit loads of piping branch junctions with local wall thinning under combined pressure and in-plane bending, based on systematic three-dimensional finite element limit analyses using elastic-perfectly plastic materials. An ideal branch junction without weld or reinforcement around the intersection is considered with two locations of wall thinning; one in the run pipe, and the other in the branch pipe. Based on FE results, effects of thinning geometries on plastic limit moments are quantified and simple approximations of plastic limit loads are proposed.

  • PDF

밀폐배관계에 있어서의 열팽창에 대한 안전설계 및 시스템 최적 설정에 관한 고찰 (A Study on Safety Engineering & System Optimization in the Closed Piping System)

  • 차순철;황순용;강경식
    • 대한안전경영과학회지
    • /
    • 제9권1호
    • /
    • pp.1-8
    • /
    • 2007
  • To improve the practical application of the thermal expansion of closed long pipeline exposing to external heating sources such as solar energy, safety engineering and system optimization for relief valve in the closed piping system are suggested through theoretical approach, correlation in view of temperature and pressure increase caused by external solar energy in the closed piping system. The profile for thermal relief valve including relieving capacity, influx heat energy, sizing criteria, set pressure, selection against back pressure is also presented. It is noted that following topic on solar relief valve should be applied to engineering, installation and commissioning.

보 구조물의 파이핑 안정성 모니터링 방안 기초 연구 (A Basic Study on the Piping Stability Monitoring Method of Weir Structure)

  • 하익수
    • 한국지반공학회논문집
    • /
    • 제39권9호
    • /
    • pp.51-61
    • /
    • 2023
  • 본 연구의 목적은 보 구조물 기초지반의 파이핑 안정성을 모니터링할 수 있는 지표를 선정하고, 선정 지표를 활용한 파이핑 안정성 모니터링 방법을 제시하는 데에 있다. 기존 연구 결과에 대한 검토와 침투모사 수치해석 결과로부터 보 기초지반에서의 간극수압 변화를 파이핑 모니터링 지표로 선정하였다. 운영 중인 보에서 간극수압계의 설치 상황을 감안하여, 간극수압계가 보 기초 하부에 1개 또는 2개 설치된 경우 각각에 대해, 다양한 상류 저수위 조건에 따른 침투해석을 수행하였다. 침투해석 결과로부터 파이핑 모니터링 방안을 이러한 각각의 경우에 대하여 제안하였다. 아울러, 제안된 모니터링 방안을 운영 중인 보에 시범 적용하였고 이를 통해 그 실효성을 확인하였다.

증기발생기 축방향 부분관통균열 전열관의 파열 압력 시험 (Burst pressure tests of axial part-through-wall steam generator tubes)

  • 이국희;김홍덕;강용석;남민우;조남철
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.56-63
    • /
    • 2014
  • In this research, burst tests for axial notched steam generator tubes were conducted. To measure the burst pressure of notched tubes, a burst testing system was manufactured. The tests were conducted under internal pressure at room temperature. Part-through-wall and through-wall notches which have various geometries with different depths and lengths were machined by electro-discharged-machined(EDM) method. The burst pressure decreased exponentially with increasing notch length and decreased almost linearly with increasing notch depth. A comparison of the burst pressure with existing burst pressure solutions for cracked tube show that the existing solution agree well with the test results.