• 제목/요약/키워드: pressure effects

검색결과 7,994건 처리시간 0.033초

추마요법이 본태성 고혈압 환자의 혈압하강에 미치는 효과 (The Effects of Chu-ma Therapy on Decreasing Blood Pressure in Essential Hypertension)

  • 김남선
    • 대한간호학회지
    • /
    • 제30권4호
    • /
    • pp.967-981
    • /
    • 2000
  • The purpose of this study is to evaluate the effects of Chu-ma therapy and to suggest that the therapy is an effective nursing intervention tool to reduce blood pressure. The research design employed was the non-synchronized research method with non- equivalent control group. A total of 30 people with essential hypertension, who were from forty to sixty five years old, participated in the study. The Chu-ma therapy was administered by every day for ten or fifteen minutes for eight weeks from 19, April to 13, June in 1999. In order to evaluate the effects of Chu-ma therapy, blood pressure of the two groups were measured once a week, and physiological parameters (epinephrine, norepinephrine, total cholesterol, HDL-cholesterol, triglycerides) were measured before and after the treatment. Collected data was analyzed by SAS package. The results of this study can be summarized as follows : 1) There were significant decrease in systolic blood pressure and diastolic blood pressure in the experimental group. 2) There were no significant changes in epinephrine, norepinephrine of the two groups. 3) There were significant decrease in total cholesterol and triglycerides, and HDL- cholesterol increased significantly in the experimental group. 4) The effect of Chu-ma therapy on the measured time on the blood pressure in experimental group was as follows: Both of systolic and diastolic blood pressures were significantly decreased after 5weeks. The result proved that Chu-ma therapy is an effective nursing intervention tool for clients with essential hypertenion. However further research is still necessary to compare the effect with the different periods and number of times for Chu-ma therapy.

  • PDF

열응력과 수압이 화강암의 변형 거동에 미치는 영향 (Effects of the Thermal Stress and Water Pressure on the Deformation Behavior of Granite)

  • 윤용균
    • 화약ㆍ발파
    • /
    • 제29권1호
    • /
    • pp.34-40
    • /
    • 2011
  • 본 연구에서는 가곡광산 화강암의 변형거동에 열응력과 수압이 미치는 영향을 평가하였다. 열응력과 수압이 미치는 영향을 해석하기 위하여 화강암 시험편에 열을 가하여 200, 300, 400, 500, 600, $700^{\circ}C$ 예열시험편을 제작하였고, 500, 600, $700^{\circ}C$ 예열시험편에 7.5MPa의 수압을 가하였다. 예열시험편에 대한 일축압축시험 결과 예열온도가 증가함에 따라 시험편의 축변형률 및 횡변형률이 증가하는 것으로 나타났으며 특히 $600^{\circ}C$ 이상 시험편에서 변형률의 증가가 현저한 것으로 나타났다. 온도에 따라 시험편의 일축압축강도와 탄성계수는 지수적으로 감소하는 것으로 측정되었다. 수압을 받은 시험편은 그렇지 않은 시험편에 비해 비탄성적인 변형거동이 큰 것으로 나타났으며 이는 수압이 예열시험편 내에 존재하는 균열의 확장과 개구에 영향을 미친다는 것을 뜻한다.

Haloperidol 이 심혈관계에 미치는 영향 (Experimental Studies on the Cardiovascular Effects of Haloperidol in Cat and Rabbit)

  • 안영수
    • 대한약리학회지
    • /
    • 제11권2호
    • /
    • pp.19-27
    • /
    • 1975
  • Haloperidol, a butyrophenone, was synthetized by Janssen and introduced for the treatment of psychosis. Although structurally different from the phenothiazines, the butyrophenones share many of their pharmacological properties, such as inhibition of conditioned avoidance response, blocking effect of amphetamine reaction, producing catalepsy, antishock effect and protection against the lethal effects of catecholalmines. Chlorpromazine can lower the arterial blood pressure through its adrenergic blocking activity, its direct effect in relaxing vascular smooth muscle, its direct effect in depressing the myocardium and its action in a complex manner on the central nervous system. In the case of haloperidol, however, was not clarified the mechanism of lowering the blood pressure. The present paper describes the effects of haloperidol on cardiovascular system to investigate the mechanisms of its actions on the arterial blood pressure. The results are followings; 1. In anesthetized cats, intravenous administration of haloperidol and chlorpromazine in the dose of 0.1mg/kg produced a slight decrease in the blood pressure, which followed by complete recovery within $30{\sim}60$ minutes. In the dose of 3mg/kg, however, both produced an abrupt and marked decrease of the blood pressure, which followed by delayed recovery. 2. Haloperidol in the dose ranges of 0.1mg to 3.0mg/kg tended to produce the heart rate slowing in the cats, while chlorpromazine has no effect on the rate. 3. Following administration of haloperidol or chlorpromazine, epinephrine reversal in the arterial blood pressure was observed in the cat, however the responses of norepinephrine and acetylcholine were little affected. 4. In the isolated rabbit atrium the contractility was depressed by haloperidol in the doses over 0.5mg per 100ml, but the rate was not affected. In contrast, the epinephrine-induced contractility was not depressed after haloperidol treatment. However, the increased rate of atrium by epinephrine was partially blocked after haloperidol. 5. In the isolated rabbit aortic strip, epinephrine-induced contraction was blocked by haloperidol. With the above results, it may be concluded that the hypotensive effect of haloperidol was largely due to ${\alpha}$-adrenergic blocking properties and the direct effect in depressing the myocardium as well as its action on central nervous system.

  • PDF

세라밴드를 이용한 운동프로그램이 여성 노인의 신체구성, 혈압 및 체력에 미치는 효과 (Effects of Exercise using Thera Band on Body Compositions, Blood Pressure and Physical Fitness in the Elderly Women)

  • 김창숙;박인혜;김미원;장숙희;김영재;박명희;김옥;선향송
    • 근관절건강학회지
    • /
    • 제14권2호
    • /
    • pp.158-168
    • /
    • 2007
  • Purpose: The purpose of this study was to determine the effects of exercise using Thera Band on body compositions, blood pressure and physical fitness in the elderly women. Method: The study was designed as a nonequivalent control group pretest-posttest quasi-experimental study. Twenty four subjects were assigned for experimental group and twenty one subjects were assigned for control group. The experimental group participated in Thera Band exercise program consisting of 60 minutes per session, 3 times a week during the period of 12 weeks. The effects of the program were assessed using the instruments measuring the body compositions, blood pressure and physical fitness before and after applying the program. Data were collected between April and June in 2006, and analyzed by $x^2$-test, t-test, ANCOVA using a SPSS 11.5 program. Results: There were statistically significant in percent of body fat, muscle strength, muscle endurance, flexibility, and balance ability, but no significant differences were found in body weight, systolic pressure and diastolic pressure. Conclusion: Exercise using Thera Band can be an effective nursing intervention to improve percent of body fat, muscle strength, muscle endurance, flexibility and balance ability in the elderly women.

  • PDF

Association between ambient particulate matter levels and hypertension: results from the Korean Genome and Epidemiology Study

  • Sewhan Na;Jong-Tae Park;Seungbeom Kim;Jinwoo Han;Saemi Jung;Kyeongmin Kwak
    • Annals of Occupational and Environmental Medicine
    • /
    • 제35권
    • /
    • pp.51.1-51.15
    • /
    • 2023
  • Background: Recently, there has been increasing worldwide concern about outdoor air pollution, especially particulate matter (PM), which has been extensively researched for its harmful effects on the respiratory system. However, sufficient research on its effects on cardiovascular diseases, such as hypertension, remains lacking. In this study, we examine the associations between PM levels and hypertension and hypothesize that higher PM concentrations are associated with elevated blood pressure. Methods: A total of 133,935 adults aged ≥ 40 years who participated in the Korean Genome and Epidemiology Study were analyzed. Multiple linear regression analyses were conducted to investigate the short- (1-14 days), medium- (1 and 3 months), and long-term (1 and 2 years) impacts of PM on blood pressure. Logistic regression analyses were conducted to evaluate the medium- and long-term effects of PM on blood pressure elevation after adjusting for sex, age, body mass index, health-related lifestyle behaviors, and geographic areas. Results: Using multiple linear regression analyses, both crude and adjusted models generated positive estimates, indicating an association with increased blood pressure, with all results being statistically significant, with the exception of PM levels over the long-term period (1 and 2 years) in non-hypertensive participants. In the logistic regression analyses on non-hypertensive participants, moderate PM10 (particulate matter with diameters < 10 ㎛) and PM2.5 (particulate matter with diameters < 2.5 ㎛) levels over the long-term period and all high PM10 and PM2.5 levels were statistically significant after adjusting for various covariates. Notably, high PM2.5 levels of the 1 year exhibited the highest odds ratio of 1.23 (95% confidence interval: 1.19-1.28) after adjustment. Conclusions: These findings suggest that both short- and long-term exposure to PM is associated with blood pressure elevation.

과량수혈이 혈역학에 미치는 영향 (Hemodynamic effects of induced overtransfusion of blood in dogs)

  • 기노석
    • Journal of Chest Surgery
    • /
    • 제17권3호
    • /
    • pp.418-423
    • /
    • 1984
  • Appreciation of the large volume deficits which may occur in surgical or trauma patients due to blood loss has led to vigorous transfusion techniques designed to overt hypovolemic shock and ischemic damage to vital organs which may develop in minutes during the hypovolemic state. In a significant proportion of patients treated with massive rapid blood or fluid transfusion, hypervolemia occurs and life threatening pulmonary edema may develop. Especially, hypervolemia may occur during transfusion for preventing development of the so-called low output syndrome following cardiac surgery. However, the most effective indicator which reveals the adequate level of transfusion is not settled yet. The present study was aimed to compare the effectiveness of the indicators suggested thus far and to determine the most sensitive one. Eight dogs were experimentally studied in terms of left atrial pressure, pulmonary arterial systolic pressure, central venous pressure, mean systemic arterial pressure and heart rate before and after induced hypervolemia with infusion of 600ml heparinized homologous blood. Immediately after induced overtransfusion of the blood, pulmonary arterial systolic pressure increased 75.0%, in omparison with the control before transfusion, left atrial pressure 58.8%, central venous pressure 44.6%, and mean systemic arterial pressure 10.1%, one hour after transfusion, pulmonary arterial systolic pressure 40.0%, left atrial pressure 21.2%, central venous pressure 14.5%, and mean systemic arterial pressure 3.2%, central venous pressure 14.5%, and mean systemic arterial pressure 3.2%, respectively. Heart rate showed no significant change throughout the experiment. These result suggested that the changes of the pulmonary arterial systolic pressure is the most sensitive indicator for detection of hypervolemia during blood transfusion.

  • PDF

동력형 욕창예방제품의 교대부양 압력 프로파 특성 (Alternating Pressure Profile Characteristics of Powered Pressure Ulcer Preventing Devices)

  • 원병희;송창섭
    • 대한인간공학회지
    • /
    • 제29권4호
    • /
    • pp.639-646
    • /
    • 2010
  • The APAM's quantitative effectiveness and comparative study in preventing and treating pressure ulcer has not been sufficiently evaluated mainly because of uncertainty of pressure load input and lack of interpretation of dynamic perfusion recovery characteristics of soft tissue. The purpose of this paper was to quantify and analyze the alternating pressure characteristics of APAM as a preventive measure for pressure ulcers. To quantify the alternating load to human body, we introduced alternating pressure profile concept and developed parametric model of the profile. Regarding pressure level and cycle time, 3 global and 7 local periodic parameters were used to define the profile such as light, standard, typical and heavy duty profile shape. Pressure impulse ratio of light duty is the lowest but pressure fluctuation is significantly high. For the same duty shape, contact conditions are changed with alternating cycle time and more dramatically in shorter alternating cycle time conditions. We can conclude that if we use shorter alternating cycle time on APAM's operation we can get more positive effects regarding to inflated contact time condition. We proposed the quantitative methods on tissue viability study of external loading by simultaneous measurement of interface pressure and tissue perfusion with proper alternating pressure profile conditions.

Volume-Controlled Mode의 기계환기시 동일환 I:E Ratio하에서 Inspiratory Pause가 기도압 몇 가스교환에 미치는 영향 (The Effects of Inspiratory Pause on Airway Pressure and Gas Exchange under Same I:E ratio in Volume-controlled Ventilation)

  • 최원준;정성한;이정아;최강현
    • Tuberculosis and Respiratory Diseases
    • /
    • 제45권5호
    • /
    • pp.1022-1030
    • /
    • 1998
  • 연구배경: Volume controlled ventilation(VCV)시 inspiratory pause의 사용은 흡기시간을 연장하여 평균기도압을 상승시키고 가스교환을 호전시키는 것으로 알려져 있다. 그러나 같은 흡기시간을 유지하더라도 inspiratory pause를 사용하였을 경우 평균기도압과 가스교환의 변화에 대하여는 잘 알려지지 않았다. 방 법: 저자들은 VCV으로 기계호흡을 받는 12명의 환자를 대상으로 흡기산소농도, 상시호흡량, 호흡수 및 I : E ratio(1 : 3)는 변화시키지 않고 5%의 pause를 사용한 경우와 사용하지 않은 경우의 기도압 및 가스교환의 변화를 관찰하여 비교하였다. 결 과: 동맥혈 이산화탄소분압은 pause를 사용한 경우 $38.6{\pm}7.4$ mmHg로 시용하지 않은 경우의 $41.0{\pm}7.7$ mmHg보다 유의하게 낮았다 (p<0.01). 동맥혈 산소분압은 pause를 사용한 경우 $94.4{\pm}23.2$ mmHg로 사용하지 않은 경우의 $91.8{\pm}19.7$ mmHg보다 높은 경향이 있었으나 (p=0.054), 폐포-동맥혈 산소분압차$(P(A-a)O_2)$는 pause 유무에 따른 차이가 없었다 ($185.3{\pm}86.5$ mmHg vs. $184.9{\pm}84.9$ mmHg, P=0.766). 평균기도압은 pause를 사용한 경우 $9.7{\pm}4.0\;cmH_2O$로 사용하지 않은 경우의 $8.8{\pm}4.0\;cmH_2O$보다 유의하게 높았다 (p<0.01). Pause를 사용했을 때의 pause pressure와 pause를 사용하지 않을 때의 최고흡기압의 차이는 호흡기계의 저항과 역상관관계를 보였으나 (r=-0.777, p<0.01), pause가 없을 때의 최고흡기압에서 pause를 사용했을 때의 최고흡기압으로의 증가는 호흡기계의 저항과 정상관관계를 보여 (r=0.811, p<0.01), 평균기도압의 차이는 호흡기계의 저항과 유의한 정상관관계를 보였다(r=0.681, p<0.05). 평균기도압의 변화는 $PaCO_2$의 변화와 상관관계를 보이지 않았다. 결 론: Volume control ventilation시 동일한 1:3 의 I:E ratio하에서라도 5%의 inspiratory pause를 사용하는 것이 평균기도압을 더 높게 유지할 수 있으며 폐환기를 호전시킬 수 있는 것으로 사료되었다. 또한 호흡기계의 저항이 증가되어 있을수록 평균기도압의 상승이 많았으나 평균기도압의 상승 정도는 폐환기의 변화와 상관관계를 보이지 않았다.

  • PDF

수소 흡수-방출에 의한 Pd 박막의 광투과도 특성변화 (Optical Transmittance Change of Pd Thin Film by Hydrogen Absorption and Desorption)

  • 조영신
    • 한국수소및신에너지학회논문집
    • /
    • 제12권4호
    • /
    • pp.287-292
    • /
    • 2001
  • The optical transmittance change of Pd thin film due to hydrogen absorption and desorption was examined at room temperature. Hydrogen absorption and desorption cycling effects on optical transmittance were measured 6 times in the pressure range between 0 and 640 torr. Optical transmittance of Pd film was increasing with increasing hydrogen pressure. Ratio of optical transmittance to the change of pressure at $\beta$ phase is bigger than that of low hydrogen pressure range.

  • PDF

침엽수종 유래 정유가 진통 및 순환기계에 미치는 영향 (The Effects of Essential Oils from Softwood on Pain and Cardiovascular System)

  • 나기정;정의배
    • 한국임상수의학회지
    • /
    • 제16권2호
    • /
    • pp.253-256
    • /
    • 1999
  • The influence of essential oils from aboriginal softwoods as Pinus densiflora, Pinus koraiensis, Chamaecyparis obtusa and Chamaecyparis pisifera on the motor coordination, pulse, mean blood artery pressure and pain reducing test was investigated in mice and rats. The motor coordination of mouse was not induced by the inhalation of each oil. Furthermore, these oils did not alter the changes of the mean blood pressure and pulse rate. Chamaecyparis pisifera trand to reduce the mean blood pressure. The abdominal pain induced by acetic acid was reduced only by an essential oil from Pinus koraiensis in mouse.

  • PDF