• 제목/요약/키워드: pressure differential system

검색결과 250건 처리시간 0.029초

화재시 제연 및 피난을 위한 기능성 차압 조절장치 개발에 관한 연구 (The Development of a Functional Pressure Controller in Smoke Management Systems for the Fire Safety of Buildings)

  • 정기창;김정훈;이정윤
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.44-48
    • /
    • 2004
  • The smoke and toxic gases generated from the building fires are proved to cause human death. Therefore, the necessity and significance of smoke control have been emphasized, and lots of studies for developing improved smoke management system have been carried out. In this study, the experiments were conducted to evaluated a function and performance in newly developed smoke management system using mechanical pressurization. As a result of this experiment, the differential pressure was 40Pa${\sim}$60Pa and the air velocity through the door was 0.7m/s between safety zone and fire zone. The functional pressure control equipment which could make proper pressure and maintain differential pressure between safety zone and fire zone was developed. And it will give a lot of helps to evacuation activity for peoples in building and fire fighting.

기계식 부압발생장치를 이용한 매연여과장치의 성능비교 (Performance Comparison of Soot Filtration Apparatus Using a Mechanical Negative Pressure Generating Device)

  • 이한성;김경현;정석호;고대권
    • 동력기계공학회지
    • /
    • 제19권1호
    • /
    • pp.13-18
    • /
    • 2015
  • Over the past years, many research works have been carried out to investigate the factors which govern the performance of diesel engines. The air pollutant emissions from the diesel engines are still significant concerns environmentally in many countries. In the present study, a novel smoke filtration system of diesel engine is proposed. This novel system is composed of filtering elements and vacuum pump driven by exhaust gases emitted from engine cylinders for capturing smoke. In order to verify the excellency of the novel filtration system, the differential pressure across the filtration system is investigated experimentally comparing with other systems which are used commercially in diesel vehicles. As a result it is founded that the differential pressure of the novel system is the smallest among them.

Numerical prediction of transient hydraulic loads acting on PWR steam generator tubes and supports during blowdown following a feedwater line break

  • Jo, Jong Chull;Jeong, Jae Jun;Yun, Byong Jo;Kim, Jongkap
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.322-336
    • /
    • 2021
  • This paper presents a numerical prediction of the transient hydraulic loads acting on the tubes and external supports of a pressurized water reactor (PWR) steam generator (SG) during blowdown following a sudden feedwater line break (FWLB). A simplified SG model was used to easily demonstrate the prediction. The blowdown discharge flow was treated as a flashing flow to realistically simulate the transient flow fields inside the SG and the connected broken feedwater pipe. The effects of the SG initial pressure or the broken feedwater pipe length on the intensities or magnitudes of transient hydraulic loads were investigated. Then predictions of the decompression pressure wave-induced impulsive pressure differential loads on SG tubes and the transient blowdown loads on SG external supports were demonstrated and the general aspects of transient responses of such transient hydraulic loads to the FWLB were discussed.

생물 안전 실험실의 자동제어 시스템 적용 사례 분석 (A Case Study on Biosafety Laboratory HVAC Control System)

  • 주영덕;김진;함호석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.84-89
    • /
    • 2008
  • The biosafety laboratory HVAC control technology may be applied in order to protect contamination of the researcher, supervisor and to prevent diffusion of biological pollution. In this study, a biosafety level, general configuration of control system, differential pressure control, distributed control system and network structure were discussed. These systems able to increase laboratory safety and efficiency of HVAC system.

  • PDF

고압 아아크 방전시스템의 각종 특성 해석에 관한 연구 (A Study on the Analysis of Various Characteristics for the High Pressure are Discharge System)

  • 지철근;박왕열;이진우
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제5권4호
    • /
    • pp.35-42
    • /
    • 1991
  • Recently, HID lamps have been considered as important in regard to the trend of energy saving, and increasingly and diversely used in various ways. This paper will show the simulating models concerning high-pressure arc discharge system directly applicable for its design and manufacture, and analyze its various characteristics. For warm-up characteristics, the evaporating process of inner atoms is described in terms of second-order differential equation: for the thermal conduction from are axis to discharge wall and outer bulb, its transfer process is introduced according to five first-order differential equations. Under the steady state satisfying LTE, the time-variant characteristics are suggested by means of time-dependent energy balance equation derived from fluid equations, approximation of radiation energy and material functions in the discharge tube. The simulating models concerning these equations are then applied for high-pressure mercury lamp.

  • PDF

병렬구조의 압력측정 시스템 개발 (Development of a Pressure Measurement System with the Parallel Structure)

  • 윤의중;김좌연;이강원;이석태
    • 한국전기전자재료학회논문지
    • /
    • 제19권4호
    • /
    • pp.328-333
    • /
    • 2006
  • In this paper, we developed a pressure measurement apparatus with the parallel structure to improve the measurement efficiency of pressure sensors by reducing the measurement time of pressure. The developed system has two parallel positions for loading Silicon pressure sensor and has a dual valve structure. The semiconductor pressure sensors prepared by Copal Electronics were used to confirm the performance of the developed measurement system. Two stage differential amplifier circuit was employed to amplify the weak output signal and the amplified output signal was improved utilizing a low-pass filter. New apparatus shows the measurement time of pressure two times shorter than that of conventional one with the serial structure, while both structures show the similar linear output versus pressure characteristics.

PCV 밸브 내부 유동특성에 관한 수치해석적 연구 (Numerical Analytic Study on Internal Flow Characteristics of a PCV valve)

  • 이종훈;이연원;김재환
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2005년도 추계학술대회 논문집
    • /
    • pp.111-116
    • /
    • 2005
  • An automobile engine has the Positive Crankcase Ventilation system (PCV system) for preventing air pollution as the environmental problem is important In this system, a PCV valve is the most important component to control the flow rate of Blowby gas which is generated by various engine powers. But, in the working place, the design of a PCV valve is very difficult because of interaction between fluid and solid motions. In this study, we investigated fluid flow characteristics using re-meshing method of a CFD technique to simulate spool behavior. As the results, a spool is periodically oscillated with time and is largely oscillated in proportion to the differential pressure between inlet and outlet. And, although the velocity at the orifice increases with the differential pressure, the flow rate of the outlet decreases. This research may give PCV designers visual flow information to help them

  • PDF

저장공간에 채워진 부피 모니터링 시스템 개발 (Development of Volume Monitoring System Filled in Storage Space)

  • 이영태;권익현
    • 반도체디스플레이기술학회지
    • /
    • 제18권4호
    • /
    • pp.129-133
    • /
    • 2019
  • In this paper, we developed a system to monitor the storage capacity of suction-type device such as vacuum cleaner or crop harvesters. The monitoring system consists of load cells and a differential pressure sensor which simultaneously monitor the weight and volume of the stock. Since weighing objects stored in storage containers alone cannot fully monitor the level of filling, more accurate monitoring can be achieved by monitoring volume and fusion with weight information. The volume was monitored using a phenomenon in which the flow rate of the inhaled air varies depending on the volume of the object filled in the storage container. In this paper, we developed a system to monitor the storage in three stages: low, medium and high.

Evaluation of Liquid Pressure Amplifier Technology

  • Reindl Douglas T.;Hong Hiki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권3호
    • /
    • pp.119-127
    • /
    • 2005
  • Liquid pressure amplifiers have been proposed as an energy saving technology for vapor compression refrigeration systems configured with direct-expansion evaporators. The technology utilizes a refrigerant pump in the high pressure liquid line as a means of maintaining a suitable pressure differential across the expansion valve while lowering condensing pressure to achieve the reduction of compressor energy consumption. Applications have been proposed on systems ranging from small unitary air-conditioning to large supermarket and commercial refrigeration systems. This paper clarifies the role of such a device in a vapor compression refrigeration system. Limitations are presented and discussed. Finally, results of detailed analyses are presented to quantify the energy consumption both with and without a liquid pressure amplifier in a unitary air conditioning system. The estimated energy savings associated with the installation of a liquid pressure amplifier are minimal.