• Title/Summary/Keyword: pressure differential system

Search Result 252, Processing Time 0.026 seconds

A Numerical Study on the Basic Design of Scrubber for Marine Diesel Engines (선박 디젤기관 스크러버의 기초설계에 관한 수치적 연구)

  • Lee, Won-Ju;Kim, In-Su;Choi, Yong-Seok;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.5
    • /
    • pp.549-557
    • /
    • 2017
  • Numerical studies have been carried out on scrubbers, which are after-treatment devices to satisfy strengthened emission regulations for sulfur dioxide and particulate matter. We investigated the problems with existing scrubbers through numerical analysis and designed and analyzed a new swirl-type scrubber that could solve these problems. As a result, with the swirl-type scrubber, exhaust gas formed a vortex in the lower part of the device, and some of this gas was released along the guide vane through the bottom surface. In this case, the pressure gradient in the vertical direction was not large, but a pressure difference between the inside and outside of the baffle was generated. The shape of the exhaust gas stream was investigated, and when water was not sprayed, the exhaust gas flowed constantly to the outlet along the guide vane, in contrast to when water was sprayed. It was confirmed that the shape of the flow was influenced by the guide vane, nozzle arrangement and water pressure. In the case of the swirl-type scrubber, impact on engine back-pressure was minimal, because differential pressure at the inlet and outlet was less than half of that with a conventional scrubber.

Analysis of High-Resolution Manometry Results in LPRD Patients Who Do Not Response to PPI Medication (양자펌프 억제제에 반응을 보이지 않은 인후두 역류질환 환자에서 고해상도 식도 내압검사의 분석)

  • Lee, Chang-Hee;Lee, Hyun-Sub;Jin, Sung-Min;Lee, Sang-Hyuk
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.23 no.1
    • /
    • pp.43-47
    • /
    • 2012
  • Background and Objectives : Laryngopharyngeal reflux disease (LPRD) originates from regurgitation of gastric contents to the laryngopharynx, and it is relatively common disease in otolaryngology. Proton-pump inhibitor (PPI) medication is frequently using treatment method in present time, but controversies exist regarding treatment for it. High-resolution manometry (HRM) system is a newly developed device that using 36 channels and pressure topography plotting program, checking the function and status of esophagus. The aim of this study was to evaluate clinical usefulness of HRM in LPRD patients who do not response to PPI medication. Materials and Method : From July 2009 to July 2010, a total of 99 patients who were suspected LPRD according to symptoms (Reflux Symptom Index >13) and laryngoscopic findings (Reflux Finding Score >7) were retrospectively enrolled in this study. Patients were consisted of 31 men and 68 women, the mean age was 51.8 years, the mean BMI was 22.46. Patients have taken PPI medication for 2 months, after medication, they performed HRM. Comparative analysis was performed with results of the difference in symptoms. Results : In 99 patients, 37 patients (37.4%) show not improvement of LPRD symptoms after PPI medication. Among them, 18 patients (48.6%) showed abnormal findings that were classified as Peristaltic dysfunction (38.9%), Diffuse esophageal spasm (11.1%), Relaxation impairment of LES (11.1%), Achalasia (5.6%), Hypotensive LES (11.1%), Relaxation impairment of UES (11.1%), Nutcracker esophagus (5.6%), Decreased resting pressure (5.6%). Other 62 patients (62.6%) show improvement of LPRD symptoms, 23 patients (37.1%) showed abnormal findings. Most common finding was Peristaltic dysfunction (43.4%) More prevalent abnormal findings of HRM were found in patients who revealed no response to PPI medication (48.6% vs. 37.1%), but it does not reach the statistical significance. Conclusion : Although statistical significances is not showed, the difference observed in the frequency of HRM abnormal finding between response and no response for PPI medication. It has been estimated that HRM may be used to determine differential diagnosis in patients with LPRD. Further studies in lager population containing normal controls will be needed to prove clinical usefulness.

  • PDF

Analysis of High-Resolution Manometry Results in LPRD Patients who do not Response to PPI Medication (양자펌프 억제제에 반응을 보이지 않은 인후두 역류질환 환자에서 고해상도 식도 내압검사의 분석)

  • Lee, Chang-Hee;Lee, Hyun-Sub;Jin, Sung-Min;Lee, Sang-Hyuk
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.22 no.2
    • /
    • pp.151-155
    • /
    • 2011
  • Background and Objectives : Laryngopharyngeal reflux disease (LPRD) originates from regurgitation of gastric contents to the laryngopharynx, and it is relatively common disease in otolaryngology. Proton-pump inhibitor (PPI) medication is frequently using treatment method in present time, but controversies exist regarding treatment for it. High-resolution manometry (HRM) system is a newly developed device that using 36 channels and pressure topography plotting program, checking the function and status of esophagus. The aim of this study was to evaluate clinical usefulness of HRM in LPRD patients who do not response to PPI medication. Subjects and Method : From July 2009 to July 2010, a total of 99 patients who were suspected LPRD according to symptoms (Reflux Symptom Index >13) and laryngoscopic findings (Reflux Finding Score >7) were retrospectively enrolled in this study. Patients were consisted of 31 men and 68 women, the mean age was 51.8 years, the mean BMI was 22.46. Patients have taken PPI medication for 2 months, after medication, they performed HRM. Comparative analysis was performed with results of the difference in symptoms. Results : In 99 patients, 37 patients (37.4%) show not improvement of LPRD symptoms after PPI medication. Among them, 18 patients (48.6%) showed abnormal findings that were classified as Peristaltic dysfunction (38.9%), Diffuse esophageal spasm (11.1%), Relaxation impairment of LES (11.1%), Achalasia (5.6%), Hypotensive LES (11.1%), Relaxation impairment of UES (11.1%), Nutcracker esophagus (5.6%), Decreased resting pressure (5.6%). Other 62 patients (62.6%) show improvement of LPRD symptoms, 23 patients (37.1%) showed abnormal findings. Most common finding was Peristaltic dysfunction (43.4%) More prevalent abnormal findings of HRM were found in patients who revealed no response to PPI medication (48.6% vs. 37.1%), but it does not reach the statistical significance. Conclusion : Although statistical significances is not showed, the difference observed in the frequency of HRM abnormal finding between response and no response for PPI medication. It has been estimated that HRM may be used to determine differential diagnosis in patients with LPRD. Further studies in lager population containing normal controls will be needed to prove clinical usefulness.

  • PDF

Rheological characterization of thermoplasticized injectable gutta percha and resilon (열연화주입형 gutta percha와 resilon의 유변학적 특성)

  • Chang, Ju-Hea;Baek, Seung-Ho;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.5
    • /
    • pp.377-384
    • /
    • 2011
  • Objectives: The purpose of this study was to observe the change in the viscoelastic properties of thermoplasticized injectable root canal filling materials as a function of temperature and to compare the handling characteristics of these materials. Materials and Methods: Three commercial gutta perchas and Resilon (Pentron Clinical Technologies) in a pellet form were heated in the Obtura-II system (Obtura Spartan) at $140^{\circ}C$ and $200^{\circ}C$, and the extrusion temperature of the thermoplasticized materials was measured. The viscoelastic properties of the materials as a function of temperature were evaluated using a rheometer. The elastic modulus G', viscous modulus G", loss tangent tan${\delta}$, and complex viscosity ${\eta}^*$ were determined. The phase transition temperature was determined by both the rheometer and a differential scanning calorimeter (DSC). The consistency of the materials was compared under compacting pressure at $60^{\circ}C$ and $40^{\circ}C$ by a squeeze test. Results: The three gutta perchas had dissimilar profiles in viscoelastic properties with varying temperature. The phase transition of softened materials into solidification occurred at $40^{\circ}C$ to $50^{\circ}C$, and the onset temperatures obtained by a rheometer and a DSC were similar to each other. The onset temperature of phase transition and the consistency upon compaction pressure were different among the materials (p < 0.05). Resilon had a rheologically similar pattern to the gutta perchas, and was featured between high and low-flow gutta perchas. Conclusions: The rheological characteristics of the thermoplasticized root canal filling materials changed under a cooling process. The dissimilar viscoelastic properties among the materials require different handling characteristics during an injecting and compacting procedure.

Evaporation Theory for Reclaimed Clay (준설 점토 지반에서의 증발 이론 개발)

  • 이형주;이인모;이영남;성상규
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.55-64
    • /
    • 2003
  • Desiccation of a soil is basically the removal of water by evaporation, which is controlled by evaporativity and evaporability. Surface evaporation improves the trafficability which is essential for the access of construction equipment in the area reclaimed with soft clay. The existing traditional methods for evaluating evaporation can not account for the deformation of reclaimed soft soils during evaporation. Therefore, a theoretical model for predicting the rate of evaporation from the surface of a deformable material is proposed. The model is based on a system of equations for coupled heat and mass transfer in unsaturated soils. The modified pressure plate extractor test and glass desiccator test were carried out to obtain the soil-water characteristic curve for a deformable soil. The column drying test was conducted to investigate one dimensional water flow, heat flow and evaporation in the surface. A finite difference program was developed to solve the coupled nonlinear partial differential equations, which permit the study of water, vapor and heat flows in the deformable soil. Comparison between measured and simulated values shows a reasonably good matching between the two.

Development of a Remote Dust Collector Bag Control System using Power Line Communication (전력선 통신을 이용한 원격 집진기 bag 제어 시스템 개발)

  • Kim, Jung-Sook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.4
    • /
    • pp.91-98
    • /
    • 2010
  • Advances in communications and control technology, the strengthening of the Internet, and the growing recognition of the urgency to reduce the risk and production cost are motivating the development of improvements in the traditional manufacturing industry. In this paper, we developed a remote dust collector bag control system which is a combination of advanced IT and traditional dust collector based on the event. At first, we made the A/D(Analog/Digital) converter using a micro processor because the differential pressure transmission, which is a sensor of the dust collector, produces analog volt data. A/D converter can provide RS-232 communication to connect with Power Line Communication(PLC) modem. And, n-bytes message format was defined for the efficient dust collector bag information transmission from a dust collector to a user. Also, we designed the data types to model the dust collector and the dust collector bag, and they were logically modeled using XML and object-oriented modeling method. In addition to that, we implemented the system for showing the dust collector bag exchange time exactly to users at real-time using various visual user interfaces.

Numerical Study on Air Egress Velocity in Vestibule Pressurization System : Characteristics of Air Flow in the Vestibule with Multiple Fire Doors in an Apartment Building (부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구: 공동주택 부속실내에 다수 출입문의 존재시 기류특성)

  • Seo, Chanwon;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.30-36
    • /
    • 2014
  • The pressurized smoke control system in the vestibule is important for fire safety in buildings because it is concerned with egress time of people and the safety of fire fighters. The vestibule pressurization system can prevent smoke from entering the vestibule using differential pressure when fire doors are closed and using the egress velocity when fire doors are open. Air supplying units in the vestibule need to be arranged by taking account of the location of doors and the volume of the vestibule in order to assure the uniform air egress velocity through a fire door when it is open. In this study, computational fluid dynamics (CFD) simulations were conducted for the vestibule where multiple doors are installed and it was found that the reverse flow occurs when the damper position in vestibule is not appropriate.

Performance Evaluation of Measuring Instrument for Infra-Red Signature Suppression System Model Test (적외선 신호저감 장치 모형시험을 위한 계측기의 성능평가)

  • SeokTae Yoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.28 no.6
    • /
    • pp.21-27
    • /
    • 2023
  • Modern naval ships install an Infra-Red Signature Suppression system (IRSS) in their exhaust pipe to reduce infrared signature emitted to the outside. In addition, naval ships are strategic assets with a very long life cycle, so high reliability of the performance of the equipment on board must be guaranteed. Therefore, equipment such as IRSS is evaluated for performance through model testing at the design stage. A variety of measuring instruments are used in IRSS model testing, and the reliability of these instruments must also be guaranteed. In this paper, a study was conducted to evaluate the reliability of measurement equipment used in IRSS model testing. The test equipment and instruments used were a hot gas wind tunnel, pitot tube, digital differential pressure gauge, thermocouple sensor, and digital recorder. As the fan speed of the hot gas wind tunnel increased, the measurement deviation of the flow decreased, and the temperature output of the thermocouple sensor showed differences in response time and stability depending on the method used.

Unsteady Analysis of the Conduction-Dominated Three-Dimensional Close-Contact Melting (열전도가 주도적인 삼차원 접촉융해에 대한 비정상 해석)

  • Yoo, Hoseon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.8
    • /
    • pp.945-956
    • /
    • 1999
  • This work reports a set of approximate analytical solutions describing the initial transient process of close-contact melting between a rectangular parallelepiped solid and a flat plate on which either constant temperature or constant heat flux is imposed. Not only relative motion of the solid block tangential to the heating plate, but also the density difference between the solid and liquid phase is incorporated in the model. The thin film approximation reduces the force balance between the solid weight and liquid pressure, and the energy balance at the melting front into a simultaneous ordinary differential equation system. The normalized model equations admit compactly expressed analytical solutions which include the already approved two-dimensional solutions as a subset. In particular, the normalized liquid film thickness is independent of all pertinent parameters, thereby facilitating to define the transition period of close-contact melting. A unique behavior of the solid descending velocity due to the density difference is also resolved by the present solution. A new geometric function which alone represents the three-dimensional effect is introduced, and its properties are clarified. One of the representative results is that heat transfer is at least enhanced at the expense of the increase in friction as the cross-sectional shape deviates from the square under the same contact area.

Hydrodynamic Characteristics of Fine Powders in the Conical Powder-Particle Fluidized Beds (원추형 분립유동층에서 미세 분체의 수력학적 특성)

  • Lee Dong Hyun;Shin Moon Kwon;Kim Eun Mi;Son Seong Yong;Park Byung Sub;Han Gui Young;Yoon Ki June
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.310-313
    • /
    • 2005
  • The conical fluidizing system of a binary mixture of Geldart C powders and Geldart A particles was defined as the conical powder-particle fluidized bed. We used a cold conical powder-particle fluidized bed model having a 0.104m-I.D. and 0.6m-high with an apex angle of $10^{\circ}$ for fluidization of a binary powder-particle mixture of 50 $vol\%$ fine carbon black powders (HI-900L, Korea Carbon Black Co.) and coarse alumina particles $(90{\mu}m)$ under different superficial gas velocities (0-0.1 m/s). The differential bed pressure drop increases with increasing gas velocity, and it goes from zero to a maximum value with increasing or decreasing gas velocity. In the conical fluidized beds of fine powders, demarcation velocities of the partial fluidization, full fluidization, partial defluidization was not observed.

  • PDF