• Title/Summary/Keyword: predicted deviation

Search Result 294, Processing Time 0.025 seconds

Prediction of Hydraulic Conductivity from Gran-size Distribution Parameters (입도분포를 이용한 투수계수의 예측)

  • Song, Young-Woo;Lee, In-Koo
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.3
    • /
    • pp.5-12
    • /
    • 2002
  • Hydraulic conductivity k is one of the most important engineering properties of soil. However, both field and laboratory procedures fur the determination of k are often tedious and expensive. This paper presents new models to predict k using statistical parameters from grain size distribution. A number of permeability tests far 36 types of sands mixed based on statistics were conducted to develop the regression-based models. Parameters used to estimate k are both the geometric mean and geometric standard deviation of the soil samples, or the particle-size distribution curve parameters such as D_{10},D_{50},D_{60}. Hydraulic conductivity predicted by this model is in good agreement with the laboratory measurements fir the soil samples obtained at 20 locations within the Korean Peninsula. The performances of the proposed models were also compared with those of existing models including Hazen's.

Flow Condensation Heat Transfer Coefficients of R22 Alternative refrigerants in Aluminum Multi-Channel Tube (알루미늄 다채널 평판관내 R22 대체냉매의 흐름 응축 열전달 성능 비교)

  • Lee, Ki-Young;Lee, Min-Hang;Jung, Dong-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.249-255
    • /
    • 2005
  • Flow condensation heat transfer coefficients(HTCs) of R22, R4IO, Propane(R290) were measured inside a horizontal 9 hole aluminum multi-channel flat tube. The main test section in the refrigerant loop was made of a 0.53 m long multi-channel flat tube of hydraulic diameter of 1.4 mm. Refrigerant was cooled by passing cold water through an annulus surrounding the test section. Data were obtained in qualities of 0.1 ${\sim}$ 0.9 at mass flux of $200{\sim}400$ $kg/m^2s$ and heat flux of $7.3{\sim}7.7$ $kW/m^2$ at the saturation temperature of $4^{\circ}C$. All popular heat transfer correlations in single-phase subcooled liquid flow and flow condensation originally developed for large single tubes predicted the present data of the multi channel flat tube within 25% deviation when effective heat transfer area was used in determining experimental data. This suggests that there is little change in flow characteristics and patterns when the tube diameter is reduced down to 1.4 mm diameter range. Hence, a modified correlation based on the present data was proposed which could be applied to small diameter tubes with effective heat transfer area. The correlation showed a mean deviation of less than 20% for all data.

  • PDF

Pool Boiling Heat Transfer Coefficients of Mixtures Containing Propane, Isobutane and HFC134a on a Plain Tube (수평관에서 프로판, 이소부탄, BFC134a를 포함한 혼합냉매의 풀비등 열전달계수)

  • Park, Ki-Jung;Baek, In-Cheol;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.955-963
    • /
    • 2006
  • Nucleate pool boiling heat transfer coefficients (HTCs) were measured with one nonazeotropic mixture of Propane/Isobutane and two azeotropic mixtures of HFC134a/Isobutane and Propane/HFC134a. All data were taken at the liquid pool temperature of $7^{\circ}C$ on a horizontal plain tube with heat fluxes of $10kW/m^2\;to\;80kW/m^2$ with an interval of $10kW/m^2$ in the decreasing order of heat flux. The measurements were made through electrical heating by a cartridge heater. The nonazeotropic mixture of Propane/Isobutane showed a reduction of HTCs as much as 41% from the ideal values. The azeotropic mixtures of HFC134a/Isobutane and Propane/HFC134a showed a reduction of HTCs as much as 44% from the ideal values at compositions other than azeotropic compositions. At azeotropic compositions, however, the HTCs were even higher than the ideal values due to the increase in the vapor pressure. For all mixtures, the reduction in heat transfer was greater with a larger gliding temperature difference. Stephan and $K{\ddot{o}}rner's$ and Jung et al's correlations predicted the HTCs of mixtures with a mean deviation of 11%. The largest mean deviation occurred at the azeotropic compositions of HFC134a/Isobutane and Propane/HFC134a.

Industrial Safety Risk Analysis Using Spatial Analytics and Data Mining (공간분석·데이터마이닝 융합방법론을 통한 산업안전 취약지 등급화 방안)

  • Ko, Kyeongseok;Yang, Jaekyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.4
    • /
    • pp.147-153
    • /
    • 2017
  • The mortality rate in industrial accidents in South Korea was 11 per 100,000 workers in 2015. It's five times higher than the OECD average. Economic losses due to industrial accidents continue to grow, reaching 19 trillion won much more than natural disaster losses equivalent to 1.1 trillion won. It requires fundamental changes according to industrial safety management. In this study, We classified the risk of accidents in industrial complex of Ulju-gun using spatial analytics and data mining. We collected 119 data on accident data, factory characteristics data, company information such as sales amount, capital stock, building information, weather information, official land price, etc. Through the pre-processing and data convergence process, the analysis dataset was constructed. Then we conducted geographically weighted regression with spatial factors affecting fire incidents and calculated the risk of fire accidents with analytical model for combining Boosting and CART (Classification and Regression Tree). We drew the main factors that affect the fire accident. The drawn main factors are deterioration of buildings, capital stock, employee number, officially assessed land price and height of building. Finally the predicted accident rates were divided into four class (risk category-alert, hazard, caution, and attention) with Jenks Natural Breaks Classification. It is divided by seeking to minimize each class's average deviation from the class mean, while maximizing each class's deviation from the means of the other groups. As the analysis results were also visualized on maps, the danger zone can be intuitively checked. It is judged to be available in different policy decisions for different types, such as those used by different types of risk ratings.

Isothermal Vapor-Liquid Equilibria at 333.15K and Thermodynamic Excess Properties for the Binary System of Methanol+Dimethyl Carbonate (Methanol+Dimethyl Carbonate 혼합계의 333.15 K 등온 기-액 평형과 열역학 과잉 물성)

  • Han, Kyu-Jin;Park, So-Jin
    • Korean Chemical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.387-392
    • /
    • 2005
  • Recently, dimethyl carbonate (DMC) is considered as an alternative of MTBE (methyl tert-butyl ether), additive for non-leaded gasoline with their fast biodegradation rate and low toxicity. DMC is usually synthesized so far by oxidative carbonylation of methanol, and recently developed synthetic process is also started with methanol. Since the phase equilibria of the system, consisted of DMC and methanol or other reaction products on different temperature and pressure is necessary for the optimum separation process design and operation. However the reported phase equilibria and physical properties for DMC mixtures in the Dortmund Data Bank (DDB; thermodynamic property data bank) are quite rare. Besides, infinitely dilute properties are not found. In this work, isothermal vapor-liquid equilibria at 333.15 K for methanol+DMC binary system and mixing properties, excess molar volume and viscosity deviation at 298.15 K are directly measured and correlated. Additionally, infinitely dilute activity coefficient of methanol in the DMC solvent at three different temperatures are measured and compared with predicted values using modified UNIFAC (Dortmund).

Boiling Heat Transfer Characteristics of R-290 in Horizontal Smooth Minichannel (수평미세관내 R-290의 비등열전달 특성)

  • Choi, Kwang-Il;Pamitran, A.S.;Oh, Jong-Taek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.11
    • /
    • pp.906-914
    • /
    • 2006
  • The present paper dealt with an experimental study of boiling heat transfer characteristics of R-290. Pressure gradient and heat transfer coefficient of the refrigerant flow inside horizontal smooth minichannel were obtained with inner tube diameter of 3.0 mm and length of 2,000 mm. The direct electric heating method was applied for supplying a heat to the refrigerant uniformly. The experiments were conducted with R-290 purity of 99.99%, at saturation temperature of 0 to $10^{\circ}C$, a mass flux range of $50{\sim}250kg/m^2s$, and a heat flux range of $5{\sim}20kW/m^2$. The heat transfer coefficients of R-290 increased with increasing mass flux and saturation temperature, wherein the effect of mass flux was higher than that of the saturation temperature. Heat flux has a low effect on the increasing of heat transfer coefficient. The heat transfer coefficient was compared with six existing heat transfer coefficient correlations. The Zhang et al.'s correlation (2004) gave the best prediction of heat transfer coefficient. A new correlation to predict the two-phase flow heat transfer coefficient was developed based on the Chen correlation. The new correlation predicted the experimental data well with a mean deviation of 11.78% and average deviation of -0.07%.

A Study on Estimating Earthquake Magnitudes Based on the Observed S-Wave Seismograms at the Near-Source Region (근거리 지진관측자료의 S파를 이용한 지진규모 평가 연구)

  • Yun, Kwan-Hee;Choi, Shin-Kyu;Lee, Kang-Ryel
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.121-128
    • /
    • 2024
  • There are growing concerns that the recently implemented Earthquake Early Warning service is overestimating the rapidly provided earthquake magnitudes (M). As a result, the predicted damages unnecessarily activate earthquake protection systems for critical facilities and lifeline infrastructures that are far away. This study is conducted to improve the estimation accuracy of M by incorporating the observed S-wave seismograms in the near source region after removing the site effects of the seismograms in real time by filtering in the time domain. The ensemble of horizontal S-wave spectra from at least five seismograms without site effects is calculated and normalized to a hypocentric target distance (21.54 km) by using the distance attenuation model of Q(f)=348f0.52 and a cross-over distance of 50 km. The natural logarithmic mean of the S-wave ensemble spectra is then fitted to Brune's source spectrum to obtain the best estimates for M and stress drop (SD) with the fitting weight of 1/standard deviation. The proposed methodology was tested on the 18 recent inland earthquakes in South Korea, and the condition of at least five records for the near-source region is sufficiently fulfilled at an epicentral distance of 30 km. The natural logarithmic standard deviation of the observed S-wave spectra of the ensemble was calculated to be 0.53 using records near the source for 1~10 Hz, compared to 0.42 using whole records. The result shows that the root-mean-square error of M and ln(SD) is approximately 0.17 and 0.6, respectively. This accuracy can provide a confidence interval of 0.4~2.3 of Peak Ground Acceleration values in the distant range.

Assessing reproductive performance and predictive models for litter size in Landrace sows under tropical conditions

  • Praew Thiengpimol;Skorn Koonawootrittriron;Thanathip Suwanasopee
    • Animal Bioscience
    • /
    • v.37 no.8
    • /
    • pp.1333-1344
    • /
    • 2024
  • Objective: Litter size and piglet loss at birth significantly impact piglet production and are closely associated with sow parity. Understanding how these traits vary across different parities is crucial for effective herd management. This study investigates the patterns of the number of born alive piglets (NBA), number of piglet losses (NPL), and the proportion of piglet losses (PPL) at birth in Landrace sows under tropical conditions. Additionally, it aims to identify the most suitable model for describing these patterns. Methods: A dataset comprising 2,322 consecutive reproductive records from 258 Landrace sows, spanning parities from 1 to 9, was analyzed. Modeling approaches including 2nd and 3rd degree polynomial models, the Wood gamma function, and a longitudinal model were applied at the individual level to predict NBA, NPL, and PPL. The choice of the best-fitting model was determined based on the lowest mean and standard deviation of the difference between predicted and actual values, Akaike information criterion (AIC), and Bayesian information criterion (BIC). Results: Sow parity significantly influenced NBA, NPL, and PPL (p<0.0001). NBA increased until the 4th parity and then declined. In contrast, NPL and PPL decreased until the 2nd parity and then steadily increased until the 8th parity. The 2nd and 3rd degree polynomials, and longitudinal models showed no significant differences in predicting NBA, NPL, and PPL (p>0.05). The 3rd degree polynomial model had the lowest prediction standard deviation and yielded the smallest AIC and BIC. Conclusion: The 3rd degree polynomial model offers the most suitable description of NBA, NPL, and PPL patterns. It holds promise for applications in genetic evaluations to enhance litter size and reduce piglet loss at birth in sows. These findings highlight the importance of accounting for sow parity effects in swine breeding programs, particularly in tropical conditions, to optimize piglet production and sow performance.

Demographics, Social Media Use and Perceived Academic Stress of Secondary School Students in St. Thomas Aquinas College, Akure, Nigeria

  • Igbinovia, Magnus Osahon;Idhalama, Ogagaoghene Uzezi;Alex-Nmecha, Juliet C.
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.9 no.4
    • /
    • pp.7-29
    • /
    • 2019
  • The study was carried out to investigate the influence of demographics and social media use on perceived academic stress of secondary school students in St. Thomas Aquinas College, Akure, Nigeria. This was achieved using five research questions and four null hypotheses. The population of the study consisted of 1,107 students at ISCED level 3, out of which 286 were selected based on the Israel (2003) model for determining sample size. The Ex-Post Facto (EPT) research design of the correlational type was employed to investigate the study while questionnaire was used for data elicitation. Out of the 286 copies distributed, 192 (67% response rate) were retrieved and analyzed using descriptive statistics (frequency, percentage, mean and standard deviation) and inferential statistics (correlation and multiple regression). The findings revealed that there is high frequency of social media use among secondary school students, majorly for meeting new friends and chatting. The perceived academic stress (PAS) of the students was found to be moderate. Of the three demographics considered, only class had significant influence on PAS. Use of social media did not have significantly influence on PAS of the students. When combined, demographics and social media use predicted PAS; and when considered relatively, of the independent variables, only class as an aspect of demographics predicted PAS. Therefore, the authors concluded that PAS of secondary school students is not directly influenced by demographics (except for class) and social media use. Based on the study's conclusion, recommendations were made.

Experiment on Collection Characteristics of Sub micron Particles in Two-Stage Parallel-Plate Electrostatic Precipitators (2단 평행판 전기집진기의 서브마이크론 입자 포집특성 실험)

  • Oh, M.D.;Yoo, K.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.237-246
    • /
    • 1994
  • Experimental data are reported for charging and collection of NaCl aerosols in the 0.03- to $0.2{\mu}m$-geometric-mean-diameter range in 2-stage parallel-plate electrostatic precipitators. The NaCl aerosols are generated with geometric standard deviation of about 1.74 and particle generation rate of about 10^9 particles/see by the constant output atomizer and injected into the air flow in the clean wind-tunnel. The 2-stage parallel-plate electrostatic precipitator installed in the test section of the wind-tunnel is operated with a positive corona discharge. The NaCl aerosols in the channel flow are sampled and transported to the aerosol particle number concentration measurement system by using the isoaxial sampling and transport system constructed based on the Okazaki and Willeke design. The aerosol particle number concentration measurement system measures the size distribution of submicrometer aerosols by an electrical mobility detection technique. It is confirmed from comparing the measured collection efficiencies in this study and the predicted ones by our previous theoretical analysis that the predicted collection efficiencies agree well with the experimental ones. It is also found from the comparison that below about $0.02{\mu}m$ all particles are not charged and the uncharged particles are not collected, and consequently 2-stage parallel-plate electrostatic precipitators are not suitable for that particle size range.

  • PDF