• 제목/요약/키워드: precision chemistry industry

검색결과 15건 처리시간 0.025초

미소용량형 토크변환기에 의한 점도측정에 관한 연구 (A Study on the Measurement of Viscosity by the Small Capacity Torque Transducer)

  • 김갑용
    • 한국정밀공학회지
    • /
    • 제16권11호
    • /
    • pp.16-21
    • /
    • 1999
  • Recently, the rheology on the fluidity of materials has been progressed remarkably. Viscosity measurement for precision-accuracy has needed very important to measure the rheological properties of materials in the field of chemistry-fiber, paint, printing-ink, plastics, rubber, foodstuff-industry, etc. And many methods of measurement have been developed lately. So in this experimental study, small capacity torque transducer with type of strain gage, different method against other existing viscometers, measured viscosity about a liquid that has flowing characteristics of newtonian liquid. Using the assumed computational equation of viscosity, it has same value of viscosity in each different radius of rotating cylinder. In the result, this equipment will be used in the viscosity measurement of a liquid taking flowing characteristics of newtonian liquid.

  • PDF

UPCU의 안정성 검토 및 초정밀 위치결정 (Stability Analysis and Ultra-Precision Positioning for UPCU)

  • 김우진;김재열;윤성운;장종훈;김유홍;최철준
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.48-53
    • /
    • 2005
  • The world, coming into the 21st century, is preparing a new revolution called a knowledge-based society after the industrial society. The interest of the world is concentrated on information technology, nano-technology and biotechnology. In particular, the nano-technology of which study was originally started from an alternative for overcoming semiconductor micro-technology. It can be applied to most industry subject such as electronics, information and communication, machinery, chemistry, bioengineering, energy, etc. They are emerging into the technology that can change civilization of human beings. Specially, ultra precision machining is quickly applied to nano-technology in the field of machinery. Lately, with rapid development of electronics industry and optic industry, there are needs for super precision finishing of various core parts required in such related apparatuses. This paper handles stability of a super precision micro cutting machine that is a core unit of such a super precision finisher, and analyzes the results depending on the hinge type and material change, using FEM analysis. By reviewing the stability, it is possible to achieve the effect of basic data collection for unit control and to reduce trials and errors in unit design and manufacturing.

  • PDF

산업구조 전환기 충북지역 산업의 발전방향 (A Study on Industrial Development Direction at Transitional Periods of Industrial Structure in Chungcheongbuk-do Region)

  • 한주성
    • 한국경제지리학회지
    • /
    • 제6권2호
    • /
    • pp.293-306
    • /
    • 2003
  • 충북지역은 지역 내 총생산의 이윤부문이 외부로 유출되고 있으므로 기반산업의 육성이 필요한데 이를 위해 주력 제조업은 주 업종으로 석유화학, 반도체 업종을, 부차적인 업종은 자동차 산업으로 하고 이들 업종에 디지털 산업을 결합시켜 고부가가치의 차세대 산업동력으로 발전시켜 나가야 할 것이다. 그리고 충북지역의 지식기반 서비스업인 교육 서비스와 보건복지 및 연구개발 서비스업은 정밀화학, 생물산업의 주 업종과 부차적인 정밀기기 업종의 지원사업으로 이들 기업간의 네트워크를 형성하고 교육기관과 연계하여 지역혁신체제를 구축하여야 할 것이다.

  • PDF

방적기계용 스핀들 인서트의 최적설계 관한 연구 (The Study for Optimal Design of Spindle Insert used in Cotton Spinning Machine)

  • 이동우;허선철;이상석;심재준
    • 한국정밀공학회지
    • /
    • 제27권4호
    • /
    • pp.72-78
    • /
    • 2010
  • Textile machinery affects various industry, such as sport leisure industry, metal and chemistry material, electric electron, mechanical energy, packing and printing industry. In case of design of textile machine, the very important fact is absorbing the minute vibration induced by spinning thread and insert which is the part of spindle plays a role of reduction of impact caused by oscillation of thread bobbin. Therefore, Optimal design was executed by design of experiments and kriging optimal design methods to prevent fracture of spindle insert under the fatigue condition and deduced the best value of design parameter to improve the stability of the products. The highest sensitivity is showed at the design parameter A and D. As the spiral number of insert is increase, tension force applied its edge is distributed at whole model and the stress concentration is reduced.

1,3-부타디엔 제조 및 취급 근로자의 노출특성에 관한 연구 (Exposure Characteristics of 1,3-Butadiene Exposed Workers)

  • 최호춘;안선희;이현석;박영욱;김경순
    • 한국산업보건학회지
    • /
    • 제19권4호
    • /
    • pp.321-327
    • /
    • 2009
  • 1,3-butadiene is classified as suspected human carcinogen, group A2(American Conference of Governmental Industrial Hygienists, ACGIH). In Korea, 1,3-butadiene has been used as a raw material; monomer, homopolymer, polybutadiene latex, acrylonitrile-butadiene-styrene(ABS) and styrene-butadiene rubber(SBR), in the petrochemistry and precision chemistry industry. As petrochemistry industry in Korea has been developed, the potential exposure possibility of 1,3-butadiene to workers can be increased. Therefore the purpose of this study is to evaluate airborne 1,3-butadiene concentration and workers' exposure levels in the workplace using 1,3-butadiene. Air samples were collected with 4-tert-butyl catechol(TBC) charcoal tube(100 mg/50 mg) and were analyzed by gas chromatograph/flame ionization detector(GC/FID) according to the Choi's method(2002). Geometric mean (GM) and arithmetic mean (AM) of total 59 workers' exposure concentrations to airborne 1.3-butadiene were 0.042 ppm and 1.51 ppm, respectively. Although most samples were lower than 1ppm, 2 samples(21.5ppm and 33.1ppm as 8hr-TWA) were exceeded the Korean standard(2ppm) over 10 times at the repair process in synthetic rubber and resin manufacture industry. 14 samples(41%) of total 34 short-term air samples were exceeded the Korean standard(10ppm as STEL) of Ministry Labor. 1,3-butadiene concentration(GM) in the synthetic rubber and resin manufacture industry(7.87ppm) was significantly higher than that in the monomer manufacure industry (0.35ppm)(p<0.05). Also in the sampling and repair process, each GM(range) was 1.39ppm(N.D.-469.6ppm) and 7.85ppm(N.D.-410.2ppm). In conclusion, it depends on the industry and process, 1,3-butadiene can be exposed to workers as high concentration for short-term.

지방산과 폴리에틸렌글리콜의 혼합에 따른 수용성 절삭유제의 절삭특성 (Drilling Properties of Water-Based Metal Working Fluid Containing Fatty Acid and Polyethylene Glycol)

  • 김영운;정근우;윤유정;김세훈;강석춘
    • 한국정밀공학회지
    • /
    • 제18권2호
    • /
    • pp.161-170
    • /
    • 2001
  • Synthetic water-based metal-cutting fluids are increasingly popular in the metal-working industry because of its environmental friendliness. The propose of this study is to investigate the synergistic effect of combining polyethylene glycol and common fatty acid in formulating a metal-cutting fluid. The tested metals were aluminum, copper and steel, and the test was performed with a modified drilling machine. From the study, it was found that there existed some synergistic effects on the drilling efficiency of the metals to decrease of cutting time, cutting energy, torque as well as the smoothness of surface depended on the formulation ratio of the two fluids.

  • PDF

Biosorption and Elution of Lead by Undaria pinnatifida

  • Suh, Jung-Ho;Suh, Myung-Gyo;Lee, Yong-Hee;Lee, Kook-Eui;Kim, Bong-Seob
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2003년도 Challenges and Achievements in Environmental Health
    • /
    • pp.111-115
    • /
    • 2003
  • Biosorption of lead by marine algae, Undaria pinnatifida, was examined. The biosorption capacity of lead by U. pinnatifida was above 30% of its own weight and proportional to the initial lead concentration. However, the opposite result was shown in different initial weight of biomass. The mechanism of biosorption was accorded to the ion exchange process.

  • PDF

Determination of Trace Impurities in Gold by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry

  • Lee, Gae-Ho;Yang, Suk-Ran;Park, Chang-Jun;Lee, Kwang-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • 제14권6호
    • /
    • pp.696-700
    • /
    • 1993
  • Gold bonding wire of 0.076 mm in diameter used in semiconductor industry, is dissoved in aqua regia. The solution is then evaporated to near dryness several times with a few drops of HCl added to prepare the final sample solution in 5% HCl. The gold matrix is separated from trace impurities by controlled potential deposition. The whole electrolysis has been carried out inside a clean bench. An optimum potential is found to be +0.25 V to give more than 99.9% Au matrix removal with better than 90 analytes remaining in the electrolyte solution. Isotope dilution calibration is employed to get the best accuracy and precision. Analytical results are presented with determination limits of the analytical method.

Determination of Heterocyclic Amines and Acrylamide in Agricultural Products with Liquid Chromatography-Tandem Mass Spectrometry

  • Lee, Kyung-Jun;Lee, Gae-Ho;Kim, HaeSol;Oh, Min-Seok;Chu, Seok;Hwang, In Ju;Lee, Jee-yeon;Choi, Ari;Kim, Cho-il;Park, Hyun-Mee
    • Toxicological Research
    • /
    • 제31권3호
    • /
    • pp.255-264
    • /
    • 2015
  • Heterocyclic amines (HCAs) and acrylamide are unintended hazardous substances generated by heating or processing of foods and are known as carcinogenic and mutagenic agents by the animal experiments. A simple method was established for a rapid and accurate determination of 12 types of HCAs (IQ, MeIQ, Glu-P-1, Glu-P-2, MeIQx, Trp-P-1, Trp-P-2, PhIP, $A{\alpha}C$, $MeA{\alpha}C$, Harman and Norharman) and acrylamide in three food matrices (non-fat liquid, non-fat solid and fat solid) by isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS). In every sample, a mixture of internal standards including $IQ-d_3$, $MeIQx-d_3$, $PhIP-d_3$, $Trp-P-2-^{13}C_2-^{15}N$ and $MeA{\alpha}C-d_3$ was spiked for quantification of HCAs and $^{13}C_3$-acrylamide was also spiked for the analysis of acrylamide. HCAs and acrylamide in sample were extracted with acetonitrile and water, respectively, and then two solid-phase extraction cartridges, ChemElut: HLB for HCAs and Accucat: HLB for acrylamide, were used for efficiently removing interferences such as pigment, lipid, polar, nonpolar and ionic compounds. Established method was validated in terms of recovery, accuracy, precision, limit of detection, limit of quantitation, and linearity. This method showed good precision (RSD < 20%), accuracy (71.8~119.1%) and recovery (66.0~118.9%). The detection limits were < 3.1 ng/g for all analytes. The correlation coefficients for all the HCAs and acrylamide were > 0.995, showing excellent linearity. These methods for the detection of HCAs and acrylamide by LC-MS/MS were applied to real samples and were successfully used for quantitative monitoring in the total diet study and this can be applied to risk assessment in various food matrices.

영위법을 이용한 미소중량 측정 장치의 기구설계 (Mechanism Design of the Micro Weighing Device by Using Null Balance Method)

  • 최인묵;우삼용;김부식;김수현
    • 대한기계학회논문집A
    • /
    • 제27권1호
    • /
    • pp.183-193
    • /
    • 2003
  • Micro-weighing device by using null balance method is being essential part in fields of high-technology industries such as precision semiconductor industry, precision chemistry, biotechnology and genetics etc. Also, requirements for high resolution and for large measurement range increase more and more. The performance of the micro-weighing device can be determined by the mechanism design and analysis. The analytical design method has been proposed for the performance improvement such as resolution, measurement range and fast response. The 2-stage displacement amplification is designed to overcome the limit of conventional force transmitting lever. The parallel spring is designed for the measurement result independent of the input force position variation. Also, the natural frequency of mechanism is analyzed for the fast response. After each analysis, optimal design has been carried out. To verify the analysis and design result, characteristics experiments had been carried out after construction. Finally, the system had been controlled.