• 제목/요약/키워드: precipitation efficiency

검색결과 407건 처리시간 0.027초

제품폐기물 중 폴리브롬화에테르류 (PBDEs) 분석방법 비교 연구 (Evaluation of analytical method for polybrominated diphenyl ethers (PBDEs) in manufactured products waste)

  • 신선경;김형섭;전태완;김태승;김종하;이정아
    • 분석과학
    • /
    • 제20권2호
    • /
    • pp.109-114
    • /
    • 2007
  • 본 연구에서는 폴리머 재질로부터 시료를 분리하기 위하여 속실렛 추출방법과 용해-침전법이 적용되어졌다. 속실렛 추출의 경우 DCM, Toluene, THF, Acetone/Hexane (1:4, v/v)의 용매가 높은 효율을 나타내는 반면, ethyl ether, acetone/ethyl ether (1:4, v/v), acetone/hexane (1:1, v/v), DCM/hexane (1:1, v/v) 용매는 낮은 효율을 보였다. 용해-침전 방법의 경우 용해를 위해 사용된 용매에 따른 차이는 없었다. 다층실리카겔 컬럼과 플로리실 컬럼의 분획실험 결과 각각 hexane 250 mL와 70 mL로 최적 용래량이 결정되었다. 실제 폐 플라스틱 분석 결과 N.D.~1028 ppm인 것으로 조사되었다.

중금속으로 오염된 점성토에서 동전기프로세스에 의한 탈착 특성 (Electrokinetic Extraction of Heavy Metal from Clayey Soil : Desorption Characteristics During Electrical Treatment)

  • 이명호;장연수
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제12권3호
    • /
    • pp.23-28
    • /
    • 2007
  • 동전기적 처리에 의한 무기 오염 물질의 이동 및 제거율을 조사하기 위해 일련의 흡착/탈착 실험 및 동전기 정화 실험을 실시하였다. 동전기적 효과로 인해 발생된 양극 부근에서의 탈착 현상 및 음극 부근에서의 침전 현상을 중금속으로 오염된 점토 시료의 흡착 및 탈착 특성과 비교하여 분석하였다. 제거 효율은 300 V/m의 전압구배로 약 4시간의 동전기적 처리 결과 80% 정도의 높은 제거 효율을 확인할 수 있었다.

광촉매와 조합된 코로나 방전 플라즈마 필터의 유해 가스 및 입자 제거 특성 (A Compact Pulse Corona Plasma System with Photocatalyst for an Air Conditioner)

  • 신수연;문재덕
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.151-155
    • /
    • 2007
  • A compact discharge plasma system with a photocatalyst has been proposed and investigated experimentally for application to air conditioners. It was found that there was intense ultra violet radiation with high energy of 3.2 eV from the corona discharge due to the DC-biased pulse voltage applied on a wire. An electrophotochemical reaction took place apparently on the surfaces of the photocatalyst of $TiO_2$ irradiated ultra violet front the discharge plasma in the proposed plasma system. The proposed discharge plasma system with the photocatalyst of $TiO_2$ showed very high removal efficiency of VOCs by tile additional electrophotochemical reactions on the photocatalyst. The proposed discharge plasma system also showed very high removal efficiency of particles such as smokes, suspended bacteria, and pollen and mite allergens by the electrostatic precipitation part. This type of corona discharge plasma system with a photocatalyst can be used as an effective means of removing both indoor pollutant gases and particles including suspended allergens.

활성탄 또는 촉매가 장착된 배리어 유전체 방전 하이브리드. 공기청정 시스템의 나노입자 및 잔류 오존 제거 특성 (Nano Particle Precipitation and Residual Ozone Decomposition of a Hybrid Air Cleaning System Comprising Dielectric Barrier Discharge Plasma and MnO2 Catalyst or Activated Carbon)

  • 변정훈;황정호;지준호;강석훈
    • 대한기계학회논문집B
    • /
    • 제27권4호
    • /
    • pp.524-533
    • /
    • 2003
  • DBD(Dielectric Barrier Discharge) plasma in air is well established for the production of large quantities of ozone and is more recently being applied to aftertreatment processes for HAPs(Hazardous Air Pollutants). Aim of this work is to determine design and operating parameters of a hybrid air cleaning system. DBD and ESP(Electrostatic Precipitator) are used as nano particle charger and collector, respectively. Pelletized MnO$_2$ catalyst or activated carbon is used fer ozone decomposition or adsorption material. AC voltage of 7~10 KV(rms) and 60 Hz is used as DBD plasma source. DC - 8 KV is applied to the ESP for particle collection. The overall particle collection efficiency for the hybrid system is over 85 % under 0.64 m/s face velocity. Ozone decomposition efficiency with pelletized MnO$_2$ catalyst or activated carbon packed bed is over 90 % when the face velocity is under 0.4 m/s in dry air.

기후변화에 따른 유통산업의 핵심 기상요인과 기업의 경제적 효율성 (Firm's Economic Efficiency and Critical Weather Information in Distribution Industry by Climate Change)

  • 이중우;고광근;전진환
    • 한국환경과학회지
    • /
    • 제19권6호
    • /
    • pp.787-797
    • /
    • 2010
  • Nowadays meteorological information is systemized as a useful knowledge which has a significant effect on the overall industrial domains over the simple data. The distribution industry, which has the short life cycle, depends on the meteorological information at the strategic level. However, it is necessary to pay attention to the continuous investment in meteorological information because there is a hostility to paying for a service, particularly it does not provide accurate and reliable information. Therefore, the purpose of this study is to increase the usefulness of meteorological information in the distribution industry for its economic effectiveness from the core meteorological factors. We found significant meteorological factors (temperature, precipitation, disaster) that have a critical influence on the distribution industry through the hierarchical analysis process, and their importance according to the type of distribution channels, such as department store, large-scale discount store, convenience store, and home shopping. We performed the AHP analysis with 103 survey samples by middle managers from the various distribution channels. We found that precipitation is the critical meteorological factor across the distribution industry. Based on this result, we stress the difference in the level of the meteorological information in order for the effectiveness of each type of distribution channels.

복합응집제를 이용한 염색가공 폐수의 처리 (Treatment of Dye-Processing Wastewater with Complex Chemical Coagulants)

  • 서명포;김병소
    • 한국산업융합학회 논문집
    • /
    • 제9권2호
    • /
    • pp.111-116
    • /
    • 2006
  • This study provides the optimal conditions treating with the coagulation process and the other chemical treatment processes for dyeing wastewater, especially various dyeing complex wastewater. The results are shown as follows: 1. Optimum reaction condition of pH for ferrous sulfate was the range of 9 to 12. And when 3,000ppm(mg/l) of ferrous sulfate was dosed, the maximum $COD_{Mn}$ removal rate was approximately 40%. 2. In case of ferrous chloride and Bittern as coagulants, optimum pH range was 10 to 11. And maximum $COD_{Mn}$ removal rate was approximately 46% to 50% for dose of 2,000ppm(mg/l) to 6,000 ppm. 3. It is confirmed that the activated sludge process following coagulation precipitation method provides better treatment efficiency than the coagulation precipitation method following the activated sludge process. 4. The purpose of this study was to produce CGF (Cyanoguanidineformaldehyde resin) by organic compounds. 5. The complex coagulation agent by this study is the most economical coagulant with Alum(aluminum sulfate) and the removal efficiency is approximately 54% with 1,000ppm(mg/l) of pH range 6 to 7.

  • PDF

중규모수치예보자료의 정량적 강수추정량 개선을 위한 인공신경망기법 (Application of Artificial Neural Network to Improve Quantitative Precipitation Forecasts of Meso-scale Numerical Weather Prediction)

  • 강부식;이봉기
    • 한국수자원학회논문집
    • /
    • 제44권2호
    • /
    • pp.97-107
    • /
    • 2011
  • 수문학적 예측에 있어서 강우수치예보의 활용성을 제고하기 위하여 인공신경망을 이용한 정량강수예측기법을 제시하였다. 본 연구에서는 2001년 6월과 7월, 2002년 8월의 중규모수치예보자료와 AWS의 3시간 누적강수, 상층기상관측소에서의 가강수량과 상대습도, 각 선행시간별 강수발생확률을 이용하여 각 선행시간에 따른 강수량을 예측하였다. 강수는 대기변수의 물리적 비선형조합으로 발생하기 때문에 강수에 영향을 미치는 대기변수와 관측강수사이의 비선형관계를 고려하는데 유용한 인공신경망기법을 이용하였다. 인공신경망의 구조는 전방향 다층퍼셉트론(feedforward multi-layer perceptron)을선택하였으며, 신경망의 학습 시 음의 강수모의값을 고려하여 무강수로전환하기 위하여 비선형 양극활성화함수를 사용하였다. 중규모수치예보모형과 인공신경망에서 예측된 강수량은 Nash-Sutcliffe Coefficient of Efficiency (NS-COE)와 Coefficient of Correlation (CORR)로 선행시간별로 통계분석을 실시하였다. 3시간 누적강수를 기준으로 NS는 한반도영역에서 평균적으로 선행시간이 12 hr인 경우 -0.04에서 0.31로, 선행시간이 24 hr인 경우 -0.04에서 0.38로, 선행시간이 36 hr인 경우 -0.03에서 0.33으로, 선행시간이 48 hr인 경우 -0.05에서 0.27로 증가하여, 강수예측의 정확도가 향상됨을 확인할 수 있었다.

경기도 지역에 대한 MODIS 위성영상 및 지점자료기반 가뭄지수의 비교·분석 (Comparison and Analysis of Drought Index based on MODIS Satellite Images and ASOS Data for Gyeonggi-Do)

  • 강유진;김형수;김동현;왕원준;이하늘;서민호;정윤재
    • 한국지리정보학회지
    • /
    • 제25권4호
    • /
    • pp.1-18
    • /
    • 2022
  • 현재 우리나라 기상청에서는 6개월 누적강수량 기준인 SPI6(standardized precipitation index 6)을 이용하여 기상가뭄을 지역별로 평가하고 있다. 하지만, SPI는 69개 기상관측소의 강수량만을 고려하여 산정되는 지수로 복합적인 이유로 나타나는 가뭄사상은 정확하게 판단하지 못하고 있는 실정이다. 따라서, 본 연구의 목적은 강수량만을 고려한 SPI와 강수량, 식생지수 및 기온을 복합적으로 고려하는 SDCI(Scaled Drought Condition Index)를 경기도 지역을 대상으로 산정 및 비교하고자 하였다. 또한, SPI와 SDCI의 비교를 통해 산정된 결과를 활용하여 지점자료기반 가뭄지수와 위성영상기반 가뭄지수의 장단점을 파악하고자 하였다. SDCI를 산정하기 위해 MODIS(MODerate resolution Imaging Spectroradiometer) 위성영상자료, 종관기상관측(ASOS) 자료 및 크리깅 기법을 사용하였다. 강수량의 지속기간은 2014년의 8개 시점에 대해 1개월, 3개월, 6개월을 각각 적용하여 SDCI1, SDCI3, SDCI6을 산정하였다. SDCI 산정 결과, SPI와 달리 약 두달 전부터 가뭄양상을 나타내기 시작하여 경기도 시군별 가뭄에 대해서 잘 드러냈다. 이를 통해, 위성영상자료와 지점자료의 결합이 가뭄지수 변화 양상에 있어서 효율성을 높였으며, 기존의 건조 지역과 더불어 습윤 지역에 대해 가뭄예측 가능성을 증대시켰음을 파악할 수 있었다.

중금속폐수에서 구리의 전기화학적 침전처리 (Electrochemical Precipitation Treatment of Copper from an Heavymetal Wastewater)

  • 김재우;이재동;이우식;지은상
    • 한국환경보건학회지
    • /
    • 제23권3호
    • /
    • pp.1-6
    • /
    • 1997
  • This research was conducted in the laboratory to investigate an alternative of Copper(Cu) removal from an heavymetal wastewater using the electrochemical precipitation(ECP) process. The ECP unit consisted of an electrolytic cell made of Titanium plate and Steel plate representing anode and cathode. The DC power source applied to the ECP unit had electrical potential(E) of 50$\pm$ 1V, respectively. The synthetic wastewater used in the experiments contained Cu in the 10 mg/l concentration and the electrode separation were 2, 3, 4 cm and the initial pH were 3, 6, 9, 12, and electrolytic concentration were 0.005, 0.0125, 0.025, 0.0375 mole, and the real heavymetal wastewater used in the experiments. From the experiment for removal efficiency according to pH variation, the low pH area doesn't give the coagulation effect by Ti(OH)$_4$ because process interfere with the coagulation and oxidation reaction, therefore the optimum pH was 4-7. The removal rate was 97.75% after the lapse of 30 minutes when copper concentration and electrolytic concentration were respectively 10 mg/l and 0.025 mole. The removal rate was 96.41% after the lapse of 30minutes when the real heavymetal wastewater used. The optimum consumption of power showed 27KWh/m$^3$ when copper concentration, electrolyte concentration and cell potential were respectively 10 mg/l, 0.025 mole and 50$\pm$ 1 Volt.

  • PDF

비용매 첨가법을 이용한 Dextran 분별침전에 관한 연구 (Studies on the Fractional Precipitation of Dextran by Nonsolvent Addition Method)

  • 최성우;구윤모
    • KSBB Journal
    • /
    • 제10권3호
    • /
    • pp.257-263
    • /
    • 1995
  • 본 연구는 비용매첨가법에 의한 "native" dextran 의 분별침전에 관한 내용으로, 첫째, 유전상수값이 다른 비용매들에 의한 dextran의 침전 특성을 조사 하였다. 둘째. dextran생산에셔 분별침전 과정의 방 법적 인 개선을 시도하였다. 침전특성을 조샤한 결과, 침전된 dextran은 비용매 함량과 일차함수관계를 보였고, 그 일차식의 가울기는 비용매의 유전상수값 과 상관관계를 보이므로서. dextran의 침전을 유도 하는 주요특성이 비용매의 유전상수임을 알았다. 그 리고 재분별에 의한 침전방법을 원용하여 dextran 의 분별침전 과정을 구성하였으며, dextran의 침전 특성 결과와 조합하여 일정한 분자량 빛 분자량 분 포를 갖는 dextran을 효율적으로 생산할 수 였는 근거를 마련하였다.

  • PDF