• Title/Summary/Keyword: pre-heater

Search Result 75, Processing Time 0.023 seconds

Effect of Processing Condition of Texturing M/C on the Physical Properties of Textured Polyester Filament (폴리에스테르 필라멘트의 텍스쳐링 공정조건이 사물성에 미치는 영향)

  • 김승진;안병훈;이민수
    • Textile Coloration and Finishing
    • /
    • v.11 no.6
    • /
    • pp.18-23
    • /
    • 1999
  • PET POY(pre-oriented-yam) were treated by false twister to high bulky. False twister have many processing parameters velocity ratio(VR), belt cross angle$(\theta)$, 1st heater temp. and K(twisting tension/untwisting tension). we analyzed the effect of properties of textured polyester yam on processing condition. Initial modulus, thermal stress, No. of snarl is decreased by 1st heater. In VR=1.97, Dry and wet shrinkage is increased but is decreased by 1st heater in VR=1.564. K/S and cristallinity tend to increase by decreasing VR.

  • PDF

Fuzzy Controller design of fuel fired heater for vehicle to control temperature (자동차용 연소식 프리히터의 온도제어를 위한 퍼지 제어기 설계)

  • Jeong, W.G.;Lee, H.W.;Lee, J.S.;Kim, J.H.;Kim, G.Y.;Jo, W.R.;Lee, G.K.
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.4
    • /
    • pp.29-36
    • /
    • 2009
  • The fuzzy controller of the FFH(Fuel Fired Heater) used for vehicle is designed in this study. Two of the most important things of the pre-heater are how fast it can be at the set temperature and how to reduce the temperature deviation in the space to a minimum. The temperature deviation of the existed FFH with PI controller for temperature controller was reduced. Also, the fuzzy controller improved the response characteristics, and then the performance was inspected. When setting the temperature in this designed fuzzy controller, it took 12 minutes in the existed PI control method to reach $25^{\circ}C$. However, it took 9 minutes and 20 seconds in the fuzzy control method. Therefore, it is proved that the fuzzy controller is better than the existed one with fast response performance as 2 minutes 40 seconds. The temperature deviation was $2.4^{\circ}C$ in the existed control method but $1.6^{\circ}C$ in the designed fuzzy controller. Accordingly, the temperature deviation was improved too.

  • PDF

Beam stability improvement of liquid metal ion source (액체 금속 이온원의 빔 안정도 향상)

  • Hyun J. W.;Yim Youn Chan;Kim Seuong Soo;Oh Hyun Joo;Park Cheol Woo;Lee Jong Hang;Choi Eun Ha;Seo Yunho;Kang Seung Oun
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.4
    • /
    • pp.182-188
    • /
    • 2004
  • Previous studies on the liquid Gallium ion sources used an electro-chemically etched tungsten wire with a coil-type heater. Such a structure requires excessive power consumption in the course of heating the liquid metal. In this work, a new structure is proposed that replaces the coil-type heater. It uses a Gallium reservoir made of six pre-etched 250$\mu\textrm{m}$ tungsten wires that surround the needle electrode. Gallium trading at the reservoir is observed to be much more stable, resulting in an improved beam stability.

Study on the Flow Characteristics of R-22, R-l34a in Small Diameter Tubes (R-22 및 R-134a의 세관 내 유동 특성에 관한 연구)

  • 홍진우;정재천;장승환;권옥배;오후규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.9
    • /
    • pp.756-765
    • /
    • 2002
  • Experimental work was performed on the flow characteristics of R-22 and R-l34a in small diameter tubes. The experimental apparatus was made up of liquid pump, pre-heater, sight-glass, condenser and measurement instruments. The sight-glass for flow pattern observations was located at the outlet of the pre-heater. The experiment was carried out to show the flow characteristics of R-22 and R-l34a. Data were taken with test conditions in the following ranges; the mass flux was ranged from 100 to 1,000 kg/$m^2s$, the saturation temperature was $30^{\circ}C$ and the vapor quality was ranged from 0.1 to 0.9. The main results were summarized as follows; In the flow patterns during evaporation, the annular flow in a 2 mm inner diameter tube occurred at a relatively lower quality and mass velocity, compared to the flow in a 8mm inner diameter tube. The evaporation flow in small diameter tubes has been shown major deviations with the Mandhane, Taitel-Dukler's and Wambs-ganss' flow pattern maps but it was similar to the Dobson's flow pattern map.

Finite Element Analysis of Heat Transfer Effects on Asphalt Pavement Heated by Pre-Heater Unit Used in Hot In-Place Recycling (유한요소해석을 통한 현장 가열 재활용 시공 장비의 가열판 용량에 따른 아스팔트 포장의 열전도성 평가)

  • Lee, Kang Hun;Lim, Jin Sun;Jeong, Kyu Dong;Im, Jeong Hyuk;Kwon, Soo Ahn;Kim, Yong Joo
    • International Journal of Highway Engineering
    • /
    • v.18 no.2
    • /
    • pp.73-82
    • /
    • 2016
  • PURPOSES: The national highways and expressways in Korea constitute a total length of 17,951 km. Of this total length of pavement, the asphalt pavement has significantly deteriorated, having been in service for over 10 years. Currently, hot in-place recycling (HIR) is used as the rehabilitation method for the distressed asphalt pavement. The deteriorated pavement becomes over-heated, however, owing to uncontrolled heating capacity during the pre-heating process of HIR in the field. METHODS: In order to determine the appropriate heating method and capacity of the pre-heater at the HIR process, the heating temperature of asphalt pavement is numerically simulated with the finite element software ABAQUS. Furthermore, the heating transfer effects are simulated in order to determine the inner temperature as a function of the heating system (IR and wire). This temperature is ascertained at $300^{\circ}C$, $400^{\circ}C$, $500^{\circ}C$, $600^{\circ}C$, $700^{\circ}C$, and $800^{\circ}C$ from a slab asphalt specimen prepared in the laboratory. The inner temperature of this specimen is measured at the surface and five different depths (1 cm, 2 cm, 3 cm, 4 cm, and 5 cm) by using a data logger. RESULTS: The numerical simulation results of the asphalt pavement heating temperature indicate that this temperature is extremely sensitive to increases in the heating temperature. Moreover, after 10 min of heating, the pavement temperature is 36%~38% and 8%~10% of the target temperature at depths of 25 mm and 50 mm, respectively, from the surface. Therefore, in order to achieve the target temperature at a depth of 50 mm in the slab asphalt specimen, greater heating is required of the IR system compared to that of the gas. CONCLUSIONS : Numerical simulation, via the finite element method, can be readily used to analyze the appropriate heating method and theoretical basis of the HIR method. The IR system would provide the best heating method and capacity of HIR heating processes in the field.

Beam stability improvement of a liquid metal ion source (액체 금속 이온원의 빔 안정도 향상)

  • 현정우;임연찬;김성수;박철우;이종항;강승언
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.504-507
    • /
    • 2004
  • Previous studies on the liquid Gallium ion sources used an electro-chemically etched tungsten wire with a coil-type heater. Such a structure requires excessive power consumption in the course of heating the liquid metal. In this work, a new structure is proposed that replaces the coil-type heater. It uses a Gallium reservoir made of six pre-etched 250 $\mu\textrm{m}$ tungsten wires that surround the needle electrode. Gallium loading at the reservoir is observed to be much more stable, resulting in an improved beam stability.

  • PDF

Analysis of combined cycle for desalination process and $CO_2$ refrigeration system (담수화 공정과 이산화탄소 냉동 시스템의 복합사이클 해석)

  • 신지영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.41-48
    • /
    • 2000
  • The characteristics of a combined cycle for the production of fresh water and air-conditioning was analyzed. The combined cycle consisted of an open water cycle and a $CO_2$ refrigeration cycle interlinked in the pre-heater of the water cycle, which is the condenser of the refrigeration cycle. The oprating conditions and criteria for the fresh water production and air-conditioning was described and their effects on the total system were evaluated. The results indicated an increase of desalinated water with the increase of hot water temperature, which resulted in the decrease of cooling capacity of the refrigeration system in this study. However, the energy saving correspond to the pre-heating of the water cycle by the condensing of the refrigeration system shows the avilable advantage of the proposed cycle as compared to other single purpose plants for desalination.

  • PDF

Performance Evaluation of a Multistage-Cyclone Pre-heating Calciner and a Rotary Kiln Calciner: Case of a Cement Process (다단사이클론 예열소성로와 로터리킬른 소성로의 성능 모형평가: 시멘트공정사례)

  • Eom, Taegyu;Choi, Sangmin
    • Journal of the Korean Society of Combustion
    • /
    • v.20 no.2
    • /
    • pp.14-27
    • /
    • 2015
  • Calcination, which represents thermal decomposition of $CaCO_3$, is the key reaction in a cement process. Some reactions including heating-up also take place simultaneously in the calcination reactors. Basic thermal performance and dimensions of the reactors in two cases, which are a rotary kiln wih a four-stage cyclone pre-heater and a simple single rotary kiln, were compared. To employ the heat transfer, mass transfer and reaction rate as well as calcination, one-dimensional modeling was conducted in each case. Some simplification about the reactors was described, however, the reliable Nusselt number and heat transfer coefficients on the reactors were used to make results reliable.

Thermo-mechanical simulations of pillar spalling for in-situ heater test by FRACOD

  • Lee Hee-Suk;Shen Baotang;Mikael Rinne
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.244-251
    • /
    • 2003
  • A two-dimensional BEM code, $FRACOD^{2D}$, was applied to simulate fracture initiation and propagation processes in a rock pillar during an in situ heater test of a rock pillar planned at the $\"{A}sp\"{o}$ Underground Rock laboratory of SKB, in Southern Sweden. To take the advantage of conventional BEM for simulating fracturing processes, but without efforts for domain integral transformation, a hybrid approach is developed to simulate the fracturing processes in rock pillar under coupled thermo-mechanical loading. The code FRACOD was used for simulating the fracture initiation and propagation processes with its boundary tractions reflecting the effects of the initial and redistributed thermomechanical stresses in the domain of interest at multiple excavation and heating steps were produced by a special algorithm of stress inversion, based on resultant thermo-mechanical stress fields at each excavation and heat loading step by a FEM code without considering fracturing processes. This hybrid approach can take the advantages of both types of numerical methods and avoids their shortcomings for fracturing process simulation and domain effects, respectively. In this paper, we present the hybrid approach for the stress, displacements, and fracturing processes at sequential excavation and heating steps of the in situ heater test as a predictive modelling, the formulation of the fracturing models and the predictive results. Two sections of borehole depth, 0.5 m and 1.5 m below the tunnel floor are considered. The pillar area is modelled with the FRACOD and the stress field produced by excavation and heating is transferred with corresponding boundary stresses. From the modelling results, the degree of fracturing and damage are evaluated for 120 days of heating. Dominated shear fracturing in the vicinity of the central pillar was observed from the models at both sections, but spalled area appears to be limited. Based on the modelling results, a sensitivity study for the effect of pre-existing fractures in the vicinity of the holes is also conducted, and the initiation and evolution of EDZ around the deposition holes are investigated using this particular numerical technique.

  • PDF